Search NASA⌕ Search

SEARCH · Search NASA

Results for “MHD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Results of duct area ratio changes in the NASA Lewis H2-O2 combustion MHD experiment

MHD power generation experiments utilizing a cesium-seeded H2-O2 working fluid have been carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments are conducted in a high-field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, generator loading, B-field strength, and electrode breakdown voltage have been investigated. In this paper the effect of area ratio, multiple loading of the duct, and duct location within the magnetic field are considered.

Smith, J. M.↗

Effect of off-design operation of MHD generators on NO/x/ chemical kinetics

The purpose of this study is to provide a capability for determining the chemical kinetic behavior of one family of pollutants, the nitrogen oxides, in the flow of a coal-fired MHD generator facility. The method used in the study allows the prediction of the nonequilibrium concentration of the minor NO(x) species in a flow otherwise assumed in equilibrium. Consideration is given to the effect of preheat, stoichiometry, and oxygen enrichment of the NO(x) concentration. The effect of preheat and stoichiometry is found to have a significant influence on the NO(x) concentration at the exit of the radiant boiler.

Simmons, G. A.↗

Results from study of potential early commercial MHD power plants and from recent ETF design work

The study deals with different 'moderate technology' entry-level commercial MHD power plants. Two of the reference plants are based on combustion of coal with air preheated in a high-temperature regenerative air heater separately fired with a low-BTU gas produced in a gasifier integrated with the power plant. The third reference plant design is based on the use of oxygen enriched combustion air. Performance calculations show that an overall power plant efficiency of the order of 44% can be reached with the use of oxygen enrichment.

Hals, F.↗

Experiments on H2-O2 MHD power generation

MHD power generation experiments utilizing a cesium-seeded H2-O2 working fluid have been carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments are conducted in a high-field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, axial duct location within the magnetic field, generator loading, B-field strength, and electrode breakdown voltage were investigated. For the operating conditions of these experiments it is found that the power output increases with the square of the B-field and can be limited by choking of the channel or interelectrode voltage breakdown which occurs at Hall fields greater than 50 volts/insulator.

Smith, J. M.↗

Solar-Driven Liquid-Metal MHD Generator

Liquid-metal magnetohydrodynamic (MHD) power generator with solar oven as its heat source has potential to produce electric power in space and on Earth at high efficiency. Generator focuses radiation from Sun to heat driving gas that pushes liquid metal past magnetic coil. Power is extracted directly from electric currents set up in conducting liquid. Using solar energy as fuel can save considerable costs and payload weight, compared to previous systems.

Hohl, F.↗

Assessment of disk MHD generators for a base load powerplant

Results from a study of the disk MHD generator are presented. Both open and closed cycle disk systems were investigated. Costing of the open cycle disk components (nozzle, channel, diffuser, radiant boiler, magnet and power management) was done. However, no detailed costing was done for the closed cycle systems. Preliminary plant design for the open cycle systems was also completed. Based on the system study results, an economic assessment of the open cycle systems is presented. Costs of the open cycle disk conponents are less than comparable linear generator components. Also, costs of electricity for the open cycle disk systems are competitive with comparable linear systems. Advantages of the disk design simplicity are considered. Improvements in the channel availability or a reduction in the channel lifetime requirement are possible as a result of the disk design.

Chubb, D. L.↗

High B-field, large area ratio MHD duct experiments

Studies of the effect of area ratio variation on the performance of a supersonic Hall MHD duct were extended up to area ratios of 6.25/1. It is shown that for a given area ratio there is a combustion pressure above which the power generating region of the duct is shock free and the power output increases linearly with the square of the magnetic field. Below this pressure a shock forms in the duct which moves upstream with increasing magnetic field strength and results in a less rapid rise in power output.

Smith, J. M.↗

Evolution of solar magnetic fields - A new approach to MHD initial-boundary value problems by the method of nearcharacteristics

A method of analysis for the MHD initial-boundary problem is presented in which the model's formulation is based on the method of nearcharacteristics developed by Werner (1968) and modified by Shin and Kot (1978). With this method, the physical causality relationship can be traced from the perturbation to the response as in the method of characteristics, while achieving the advantage of a considerable reduction in mathematical procedures. The method offers the advantage of examining not only the evolution of nonforce free fields, but also the changes of physical conditions in the atmosphere accompanying the evolution of magnetic fields. The physical validity of the method is demonstrated with examples, and their significance in interpreting observations is discussed.

Nakagawa, Y.↗

Dynamics of coronal transients - Two-dimensional non-plane MHD models

Numerical results are obtained for non-plane MHD responses to a sudden energy release in a stratified model atmosphere. In agreement with observations, it is shown that after the energy release, the magnetic field affected by the energy release relaxes toward the potential configuration while the outer atmospheric fields increase its shear. Additional results suggest a new way of interpreting the energy storage and release in repeated flares.

Nakagawa, Y.↗

A three dimensional MHD model of the earth's magnetosphere

The results of a global MHD calculation of the steady state solar wind interaction with a dipole magnetic field are presented. The computer code used, being much faster than previous codes, makes it possible to increase the number of grid points in the system by an order of magnitude. The resulting model qualitatively reproduces many of the observed features of the quiet time magnetosphere including the bow shock, magnetopause, and plasma sheet.

Wu, C. C.↗

Compression of Jupiter's magnetosphere by the solar wind - Reexamination via MHD simulation of evolving corotating interaction regions

Major changes in the solar wind before, during and after the Pioneer 10 and 11 missions' encounter with the Jovian magnetosphere are considered. A numerical simulation of the multiple corotating interaction region (CIR) evolutions from one spacecraft to its sister spacecraft is shown to have confirmed the suggestion by Smith et al (1978) that Jupiter's magnetosphere was compressed by interplanetary CIRs during three out of four of the observed events. The MHD simulation presented suggests that the Jupiter magnetosphere reacts to solar wind rarefactions by expanding. A pair of previously unexplained magnetopause crossings of the Pioneer 11 outbound pass may be due to a delayed reexpansion of the Jupiter magnetosphere from a compression that occurred during the inbound pass.

Smith, Z. K.↗

Magnetohydrodynamics MHD Engineering Test Facility ETF 200 MWe power plant. Conceptual Design Engineering Report CDER. Volume 3: Costs and schedules

The estimated plant capital cost for a coal fired 200 MWE electric generating plant with open cycle magnetohydrodynamics is divided into principal accounts based on Federal Energy Regulatory Commision account structure. Each principal account is defined and its estimated cost subdivided into identifiable and major equipment systems. The cost data sources for compiling the estimates, cost parameters, allotments, assumptions, and contingencies, are discussed. Uncertainties associated with developing the costs are quantified to show the confidence level acquired. Guidelines established in preparing the estimated costs are included. Based on an overall milestone schedule related to conventional power plant scheduling experience and starting procurement of MHD components during the preliminary design phase there is a 6 1/2-year construction period. The duration of the project from start to commercial operation is 79 months. The engineering phase of the project is 4 1/2 years; the construction duration following the start of the man power block is 37 months.

Source record↗

Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER). Volume 1: Executive summary

Main elements of the design are identified and explained, and the rationale behind them was reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates are presented, and the engineering issues that should be reexamined are identified. The latest (1980-1981) information from the MHD technology program is integrated with the elements of a conventional steam power electric generating plant.

Source record↗

End region and current consolidation effects upon the performance of an MHD channel for the ETF conceptual design

The effects of MHD channel end regions on the overall power generation were considered. The peak plant thermodynamic efficiency was found to be slightly lower than for the active region (41%). The channel operating point for the peak efficiency was shifted to the supersonic mode (Mach No., M sub c approx. 1.1) rather than the previous subsonic operation (M sub c approx. 0.9). The sensitivity of the channel performance to the B-field, diffuser recovery coefficient, channel load parameter, Mach number, and combustor pressure is also discussed. In addition, methods for operating the channel in a constant-current mode are investigated. This mode is highly desirable from the standpoint of simplifying the current and voltage consolidation for the inverter system. This simplification could result in significant savings in the cost of the equipment. The initial results indicate that this simplification is possible, even under a strict Hall field constraint, with resonable plant thermodynamic efficiency (40.5%).

Wang, S. Y.↗

Effect of vacuum exhaust pressure on the performance of MHD ducts at high B-field

The effect of area ratio variation on the performance of a supersonic Hall MHD duct is investigated. Results indicate that for a given combustion pressure there exists an area ratio below which the power generating region of the duct is shock free and the power output increases linearly with the square of the magnetic field. For area ratios greater than this, a shock forms in the power generating region which moves upstream with increasing magnetic field strength resulting in a less rapid raise in the power output. The shock can be moved downstream by either increasing the combustion pressure of decreasing the exhaust pressure. The influence of these effects upon duct performance is presented.

Smith, J. M.↗

MHD oxidant intermediate temperature ceramic heater study

The use of three types of directly fired ceramic heaters for preheating oxygen enriched air to an intermediate temperature of 1144K was investigated. The three types of ceramic heaters are: (1) a fixed bed, periodic flow ceramic brick regenerative heater; (2) a ceramic pebble regenerative heater. The heater design, performance and operating characteristics under conditions in which the particulate matter is not solidified are evaluated. A comparison and overall evaluation of the three types of ceramic heaters and temperature range determination at which the particulate matter in the MHD exhaust gas is estimated to be a dry powder are presented.

Carlson, A. W.↗

End region and current consolidation effects upon the performance of an MHD channel for the ETF conceptual design

It is noted that operating conditions which yielded a peak thermodynamic efficiency (41%) for an EFT-size MHD/steam power plant were previously (Wang et al., 1981; Staiger, 1981) identified by considering only the active region (the primary portion for power production) of an MHD channel. These previous efforts are extended here to include an investigation of the effects of the channel end regions on overall power generation. Considering these effects, the peak plant thermodynamic efficiency is found to be slightly lowered (40.7%); the channel operating point for peak efficiency is shifted to the supersonic mode (Mach number of approximately 1.1) rather than the previous subsonic operation (Mach number of approximately 0.9). Also discussed is the sensitivity of the channel performance to the B-field, diffuser recovery coefficient, channel load parameter, Mach number, and combustor pressure.

Wang, S. Y.↗

Effect of vacuum exhaust pressure on the performance of MHD ducts at high B-field

The effect of area ratio variation on the performance of a supersonic Hall MHD duct showed that for a given combustion pressure there exists an area ratio below which the power generating region of the duct is shock free and the power output increases linearly with the square of the magnetic field. For area ratios greater than this, a shock forms in the power generating region which moves upstream with increasing magnetic field strength resulting in a less rapid raise in the power output. The shock can be moved downstream by either increasing the combustion pressure or decreasing the exhaust pressure. The influence of these effects upon duct performance is presented in this paper.

Smith, J. M.↗