Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIRROR RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Hot ion plasma heating experiments in SUMMA

Initial results are presented for the hot-ion plasma heating experiments conducted in the new SUMMA (superconducting magnetic mirror apparatus) at NASA Lewis Research Center. A discharge is formed by applying a radially inward dc electric field between cylindrical anodes and hallow cathodes located at the peak of the mirrors. Data were obtained at midplane magnetic field strengths from 1.0 to 3.5 tesla. Charge-exchange neutral particle energy analyzer data were reduced to ion temperatures using a plasma model that included a Maxwellian energy distribution superimposed on an azimuthal drift, finite ion orbits, and radial variations in density and electric field. The best ion temperatures in a helium plasma were 5 keV and in hydrogen the H2(+) and H(+) ions were 1.2 keV and 1 keV respectively. Optical spectroscopy line broadening measurements yielded ion temperatures about 50 percent higher than the charge-exchange neutral particle analyzer results. Spectroscopically obtained electron temperature ranged from 3 to 30 eV. Ion temperature was found to scale roughly linearly with the ratio of power input-to-magnetic field strength, P/B.

Reinmann, J. J.↗

The Extended Q-Range Small Angle Neutron Scattering Diffractometer at the SNS

The Extended Q-Range Small Angle Neutron Scattering Diffractometer (EQ-SANS) at the Spallation Neutron Source is designed to have wide neutron momentum transfer (Q) coverage, high neutron beam intensity, and good wavelength resolution. In addition, the design and construction of the instrument aim at achieving maximum signal to noise ratio by minimizing the background. The instrument is located on the 60Hz SNS target. It has a primary flight path of 14m. Its secondary flight path varies from ~1m to 10m. One of the key components in the primary flight path is the neutron optics, consisting of a true-curved multi channel beam bender and sections of neutron guides. The optics is optimized to reduce the neutron transport loss to a minimum, thereby maximizing the available flux on sample. It also enables the avoidance of the direct line of sight of the neutron moderator at downstream locations. The instrument has three bandwidth-limiting choppers. These choppers effectively eliminate higher frame neutrons up to ~38 from the beam. A frame overlap mirror further cleans up the beam by reflecting out neutrons whose wavelengths are longer than ~33 . The bandwidth choppers also allow a frame-skipping mode of operation, which enables the EQ-SANS diffractometer to achieve a dynamic Q-range equivalent to that of a similar machine on a 20Hz source. The two-dimensional low-angle detector, based on 3He tube technologies, offers very high counting rates and counting efficiency. Initial operations have shown that the instrument has achieved its best-in-class design requirement.

EQ-SANS↗

PHOTOIONIZATION MODELING OF THE LOW-LUMINOSITY SEYFERT 1 NUCLEUS IN NGC 3516

Spectroscopic observations of the low-luminosity Seyfert 1 nucleus in NGC 3516 obtained with the Hubble Space Telescope show that the visible spectrum is dominated by Balmer emission lines of hydrogen (H) and a continuum luminosity that rises into the UV. The anomalous Hα/Hβ emission line ratio, the Balmer emission line luminosity, and the distinctive shape observed for the Hα emission line profile serve as important constraints for any photoionization model aimed at explaining the visible emission line spectrum of NGC 3516. Photoionization modeling using Cloudy demonstrates that the central UV–X-ray source is able to completely ionize the H gas in between the Balmer and dust reverberation radii if the electron density is ⩽3 × 10{sup 7} cm{sup −3} throughout. Thus, according to this model the region responsible for producing the visible H lines is a dust-free shell of ionized H gas. Interestingly, the model predicts a rapid rise in the electron temperature as the central UV–X-ray source is approached, mirrored by an equally precipitous decrease in the Balmer line emissivity that coincides with the Balmer reverberation radius, providing a natural explanation for the finite width observed for H Balmer lines. Collectively, the merit of the model is that it explains the relative intensities of the three brightest Balmer lines and the shape of the Hα emission line profile. However, questions remain concerning the unusually weak forbidden lines that cannot be addressed using Cloudy due to limitations with the code.

79 ASTRONOMY AND ASTROPHYSICS↗

The motional Stark effect diagnostic for ITER using a line-shift approach

The United States has been tasked with the development and implementation of a motional Stark effect (MSE) system on ITER. In the harsh ITER environment, MSE is particularly susceptible to degradation, as it depends on polarimetry, and the polarization reflection properties of surfaces are highly sensitive to thin film effects due to plasma deposition and erosion of a first mirror. Here we present the results of a comprehensive study considering a new MSE-based approach to internal plasma magnetic field measurements for ITER. The proposed method uses the line shifts in the MSE spectrum (MSE-LS) to provide a radial profile of the magnetic field magnitude. To determine the utility of MSE-LS for equilibrium reconstruction, studies were performed using the ESC-ERV code system. A near-term opportunity to test the use of MSE-LS for equilibrium reconstruction is being pursued in the implementation of MSE with laser-induced fluorescence on NSTX. Though the field values and beam energies are very different from ITER, the use of a laser allows precision spectroscopy with a similar ratio of linewidth to line spacing on NSTX as would be achievable with a passive system on ITER. Simulation results for ITER and NSTX are presented, and the relative merits of the traditional line polarization approach and the new line-shift approach are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A mobile system for a comprehensive online-characterization of nanoparticle aggregates based on wide-angle light scattering and laser-induced incandescence

A mobile demonstrator for the comprehensive online-characterization of gas-borne nanoparticle aggregates is presented. Two optical measurement techniques are combined, both utilizing a pulsed Nd:YAG laser as light source. Aggregate size and fractal dimension are measured by Wide-Angle Light Scattering (WALS). An ellipsoidal mirror images elastically scattered light from scattering angles between 10° and 165° onto a CCD-camera chip resulting in an almost complete scattering diagram with high angular resolution. Primary particle size and volume fraction are measured by time-resolved Laser-Induced Incandescence (TiRe-LII). Here, particles are heated up to about 3000 K by the short laser pulse, the enhanced thermal radiation signal is detected with gated photomultiplier tubes. Analysis of the signal decay time and maximum LII-signal allows for the determination of primary particle diameter and volume fraction. The performance of the system is demonstrated by combined measurements on soot nanoparticle aggregates from a soot aerosol generator. Particle and aggregate sizes are varied by using different equivalence ratios of the combustion in the generator. Soot volume fraction can be adjusted by different levels of dilution with air. Online-measurements were carried out demonstrating the favorable performance of the system and the potential for industrial applications such as process control and product development. The particle properties obtained are confirmed through transmission electron microscopy analysis on representative samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing photovoltaic module mechanics using composite plate theories and finite element solutions

Deflection and stress calculated from an experimentally validated, high-fidelity finite element model (FEM) of a photovoltaic module experiencing mechanical load was compared to results from a simplified FEM treating the module laminate as a homogenized composite using a rule of mixtures approach, and further compared to analytical calculations treating the module as a Kirchoff-Love flat plate. The goal of this study was to determine the error incurred by analyzing module mechanics with varying levels of simplification, since resolving the aspect ratios of a module is computationally expensive. Homogenized FEMs were found to underpredict peak deflection under a 1.0 kPa load by between 13 and 19% for lower and upper bound application of the rule of mixtures. However, module shape was captured, implying that a useful replication of a resolved model could be achieved with a reduced, calibrated material stiffness. Homogenized stress results captured glass layer tensile stress components to within 46 to 52% at a sample location of interest, though agreement was poor through the remainder of the laminate due to the lack of material resolution. For plate theory, deflection was overpredicted by 45 to 67% for upper and lower bound homogenizations, and frame-adjacent module shapes were not adequately replicated. Stress results mirrored FEM trends but magnitudes were not well correlated to resolved model values. These results support the use of homogenized laminate models for module shape derivation, though resolved models remain necessary for stress analyses. The accuracy of plate theory was found to be inadequate for most applications.

14 SOLAR ENERGY↗

Design of QMF (Quadrature Mirror Filter) in spatial domain and edge encoding

Simoncelli and Adelson have extended the one dimensional Quadrature Mirror Filter (QMF) to two dimensions with hexagon symmetry and three dimensional spatio-temporal extensions with rhombic-duodecahedray symmetry. Jain and Crochiere presented an excellent QMF design technique in the time domain. It is proposed to extend the design of a two dimensional QMF over a rectangular lattice in the spatial domain based primarily on the extension of the idea of Jain and Crochiere. In addition, the design will investigate the use of two dimensional Z-transformations. Since this proposed QMF is intended for the applications in image processing, all the important and interesting engineering issues will be addressed throughout the development phase. The design of a two dimensional QMF is discussed. The motivation is to achieve an extremely high data compression ratio. It is entirely possible to achieve dramatic results when pattern recognition techniques are employed. The final goal is the demonstration of extremely high data compression ratios using NASA pictures.

Wang, Paul P.↗

COMBINED CO AND DUST SCALING RELATIONS OF DEPLETION TIME AND MOLECULAR GAS FRACTIONS WITH COSMIC TIME, SPECIFIC STAR-FORMATION RATE, AND STELLAR MASS

We combine molecular gas masses inferred from CO emission in 500 star-forming galaxies (SFGs) between z = 0 and 3, from the IRAM-COLDGASS, PHIBSS1/2, and other surveys, with gas masses derived from Herschel far-IR dust measurements in 512 galaxy stacks over the same stellar mass/redshift range. We constrain the scaling relations of molecular gas depletion timescale (t {sub depl}) and gas to stellar mass ratio (M {sub mol} {sub gas}/M{sub *} ) of SFGs near the star formation ''main-sequence'' with redshift, specific star-formation rate (sSFR), and stellar mass (M{sub *} ). The CO- and dust-based scaling relations agree remarkably well. This suggests that the CO → H{sub 2} mass conversion factor varies little within ±0.6 dex of the main sequence (sSFR(ms, z, M {sub *})), and less than 0.3 dex throughout this redshift range. This study builds on and strengthens the results of earlier work. We find that t {sub depl} scales as (1 + z){sup –0.3} × (sSFR/sSFR(ms, z, M {sub *})){sup –0.5}, with little dependence on M {sub *}. The resulting steep redshift dependence of M {sub mol} {sub gas}/M {sub *} ≈ (1 + z){sup 3} mirrors that of the sSFR and probably reflects the gas supply rate. The decreasing gas fractions at high M{sub *} are driven by the flattening of the SFR-M {sub *} relation. Throughout the probed redshift range a combination of an increasing gas fraction and a decreasing depletion timescale causes a larger sSFR at constant M {sub *}. As a result, galaxy integrated samples of the M {sub mol} {sub gas}-SFR rate relation exhibit a super-linear slope, which increases with the range of sSFR. With these new relations it is now possible to determine M {sub mol} {sub gas} with an accuracy of ±0.1 dex in relative terms, and ±0.2 dex including systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

Strange quark suppression and strange hadron production in pp collisions at energies available at the BNL Relativistic Heavy Ion Collider and the CERN Large Hadron Collider

The parton and hadron cascade model PACIAE based on PYTHIA is utilized to systematically investigate strange particle production in pp collisions at energies available at the BNL Relativistic Heavy Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC). Globally speaking, the PACIAE results of the strange particle rapidity density at midrapidity and the transverse momentum distribution are better than those of PYTHIA (default) in comparison with STAR and ALICE experimental data. This may represent the importance of the parton and hadron rescatterings, as well as the reduction mechanism of strange quark suppression, added in the PACIAE model. The K/{pi} ratios as a function of reaction energy in pp collisions from CERN Super Proton Synchrotron (SPS) to LHC energies are also analyzed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Segmented Mirror Image Degradation Due to Surface Dust, Alignment and Figure

In 1996 an algorithm was developed to include the effects of surface roughness in the calculation of the point spread function of a telescope mirror. This algorithm has been extended to include the effects of alignment errors and figure errors for the individual elements, and an overall contamination by surface dust. The final algorithm builds an array for a guard-banded pupil function of a mirror that may or may not have a central hole, a central reflecting segment, or an outer ring of segments. The central hole, central reflecting segment, and outer ring may be circular or polygonal, and the outer segments may have trimmed comers. The modeled point spread functions show that x-tilt and y-tilt, or the corresponding R-tilt and theta-tilt for a segment in an outer ring, is readily apparent for maximum wavefront errors of 0.1 lambda. A similar sized piston error is also apparent, but integral wavelength piston errors are not. Severe piston error introduces a focus error of the opposite sign, so piston could be adjusted to compensate for segments with varying focal lengths. Dust affects the image principally by decreasing the Strehl ratio, or peak intensity of the image. For an eight-meter telescope a 25% coverage by dust produced a scattered light intensity of 10(exp -9) of the peak intensity, a level well below detectability.

Schreur, Julian J.↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluctuation dynamo in a weakly collisional plasma

The turbulent amplification of cosmic magnetic fields depends upon the material properties of the host plasma. In many hot, dilute astrophysical systems, such as the intracluster medium (ICM) of galaxy clusters, the rarity of particle–particle collisions allows departures from local thermodynamic equilibrium. These departures – pressure anisotropies – exert anisotropic viscous stresses on the plasma motions that inhibit their ability to stretch magnetic-field lines. We present an extensive numerical study of the fluctuation dynamo in a weakly collisional plasma using magnetohydrodynamic (MHD) equations endowed with a field-parallel viscous (Braginskii) stress. When the stress is limited to values consistent with a pressure anisotropy regulated by firehose and mirror instabilities, the Braginskii-MHD dynamo largely resembles its MHD counterpart, particularly when the magnetic field is dynamically weak. If instead the parallel viscous stress is left unabated – a situation relevant to recent kinetic simulations of the fluctuation dynamo and, we argue, to the early stages of the dynamo in a magnetized ICM – the dynamo changes its character, amplifying the magnetic field while exhibiting many characteristics reminiscent of the saturated state of the large-Prandtl-number ( ${Pm}\gtrsim {1}$ ) MHD dynamo. We construct an analytic model for the Braginskii-MHD dynamo in this regime, which successfully matches simulated dynamo growth rates and magnetic-energy spectra. A prediction of this model, confirmed by our numerical simulations, is that a Braginskii-MHD plasma without pressure-anisotropy limiters will not support a dynamo if the ratio of perpendicular and parallel viscosities is too small. This ratio reflects the relative allowed rates of field-line stretching and mixing, the latter of which promotes resistive dissipation of the magnetic field. Finally, in all cases that do exhibit a viable dynamo, the generated magnetic field is organized into folds that persist into the saturated state and bias the chaotic flow to acquire a scale-dependent spectral anisotropy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System description

The VAS, carried onboard the GOES 4 and 5 satellites, is a radiometer with 8 visible channel detectors and 6 thermal detectors that detect infrared radiation in 12 spectral bands. A filter wheel in front of the detector is used to achieve the spectral selection. The spatial resolution is 0.9 kilometer in the visible and 7 or 14 kilometers in the infrared depending on the detector used. Full Earth disk coverage is accomplished by spinning in the west to east direction at 100 rpm and by stepping a scan mirror from north to south. Additional VAS instrument characteristics are summarized. The VAS has three operating modes: the operational VISSR mode, the multispectral imaging (MSI) mode, and the dwell sounding (DS) mode. The operational VISSR mode is used by NOAA/NESS for its operational products, which include a visible picture and an 11 micrometer infrared (channel 8) picture at half hour intervals. The other modes are VAS unique. The MSI mode combines the operational VISSR capability (visible plus infrared window) with two additional spectral channels to provide half hourly full Earth disk imagery of atmospheric water vapor, temperature, and cloud distribution. The DS mode is used primarily for sounding to obtain the temperature and moisture profiles. In this mode, multiple spins on the same scan line in a given band are averaged to obtain the required signal to noise ratio for sounding.

Montgomery, H.↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interatomic Coulombic decay following Ne 1s Auger decay in NeAr

Using momentum-resolved electron-ion multicoincidence spectroscopy, we have investigated interatomic Coulombic decay (ICD) in the heteronuclear NeAr dimer following Ne 1s Auger decay. The measured intensity ratio for the three ICD transitions Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 1}P)Ar to Ne{sup 2+}(2p{sup -2} {sup 1}S)-Ar{sup +}(3p{sup -1}), Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 1}P)Ar to Ne{sup 2+}(2p{sup -2} {sup 1}D)-Ar{sup +}(3p{sup -1}), and Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 3}P)Ar to Ne{sup 2+}(2p{sup -2} {sup 3}P)-Ar{sup +}(3p{sup -1}) reasonably agree with predictions. The kinetic energy release distribution for the fragmentation to Ne{sup 2+}(2p{sup -2} {sup 1}D)-Ar{sup +}(3p{sup -1}) after the ICD transition from singlet Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 1}P)Ar state, which is a mirror image of the kinetic energy distribution of the emitted ICD electrons, suggests that the corresponding ICD rate is roughly two times lower than predicted by ab initio calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗