EPCAPE-PT-LANL Measurements: Soot Particle Aerosol Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

A new approach to mass spectrometer measurements of thermospheric density

The gas sampling problem in satellite and high velocity probes was investigated by applying the theory of a drifting Maxwellian gas. A lens system using a free stream ion source was developed and experimentally evaluated over the pressure range of 0.00001 to 0.01 N/m sq (approx. 10 to the minus 7th power to 0.0001 torr). The source has high beam transparency, which minimizes gas-surface collisions within, or near, the ionization volume. It is shown that for high ion energy (60 eV), the extracted ion beam has an on-axis energy spread of less than 4 eV, and that 90 percent of the ions are within 2.5 deg of the beam axis. It is concluded that the molecular beam mass spectrometer concept, developed for gas density measurements in the upper atmosphere, substantially reduces gas-surface scattering and gas-surface reactions in the sample, and preserves the integrity of the gas sample during the analysis process. Studies show that both the Scout and Delta launch vehicles have adequate volume, control, velocity, and data acquisition capability necessary to obtain thermospheric number density in real time.

Melfi, L. T., Jr.↗

Calibration of the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite

The SAM suite of instruments on the "Curiosity" Rover of the Mars Science Laboratory (MSL) is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The mission of the MSL investigations is to advance beyond the successful search for aqueous transformation in surface environments at Mars toward a quantitative assessment of habitability and preservation through a series of chemical and geological measurements. The SAM suite was delivered in December 2010 (Figure 1) to the Jet Propulsion Laboratory for integration into the Curiosity Rover. We previously outlined the range of SAM solid and gas calibrations implemented or planned and here we discuss a specific set of calibration experiments to establish the response of the SAM Quadrupole Mass Spectrometer (QMS) to the four most abundant gases in the Martian atmosphere CO2, N2, Ar, and O2, A full SAM instrument description and calibration report is presently in preparation.

Mahaffy, P. R.↗

A revised thermospheric model based on mass spectrometer and incoherent scatter data - MSIS-83

It is noted that the model presented here extends the previous description of neutral parameters to the base of the thermosphere in a continuous manner while maintaining the basic structure of the MSIS model at higher altitudes. As the altitude decreases, the composition approaches lower atmosphere values, whereas yearly, and to a lesser extent daily, variations in temperature and density are in reasonable agreement with earlier results for the lower thermosphere. An alternate description is given of magnetic storm variations on the basis of the three hour ap indices and an 8- to 10-hour exponential decay in thermospheric density and temperature response after a heating event. Additional coefficients are included for the time independent and magnetic activity terms, among them a longitudinally dependent seasonal magnetic activity effect. The description of molecular oxygen derives from mass spectrometer and EUV absorption measurements rather than ion chemistry.

Hedin, A. E.↗

Mass spectrometer use in a large chamber

The early satellites were somewhat insensitive to contamination produced during the construction and testing phases. The On-Orbit lifetime was such that contamination effects went either unnoticed or unrecognized. With today's On-Orbit lifetimes approaching 10+ years, contamination has become a paramount concern. The scientific payloads have increased in complexity and sensitivity. The ability to clean a contaminated sensor has greatly diminished. This requires better pumping systems and methods for improved monitoring. The conversion from diffusion pumped thermal vacuum chambers to cryo pumped chambers with the use of Misner traps and selective cold traps has reduced contamination. Witness samples supply a record of the condensates that remain after a testing cycle, but impart no knowledge of the contaminant migration during the cycle that may be a month in duration. Due to a customer's request that mass spectrometry be used during the testing of their spacecraft, a consultant was contracted to install a mass spectrometer to determine the feasibility of the instrument. The equipment and methodology described will start with the original system and its evolution to GE's present system.

Chuvala, Tom↗

Carbon and Sulfur Isotopic Composition of Rocknest Soil as Determined with the Sample Analysis at Mars(SAM) Quadrupole Mass Spectrometer

The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity rover got its first taste of solid Mars in the form of loose, unconsolidated materials (soil) acquired from an aeolian bedform designated Rocknest. Evolved gas analysis (EGA) revealed the presence of H2O as well as O-, C- and S-bearing phases in these samples. CheMin did not detect crystalline phases containing these gaseous species but did detect the presence of X-ray amorphous materials. In the absence of definitive mineralogical identification by CheMin, SAM EGA data can provide clues to the nature and/or mineralogy of volatile-bearing phases through examination of temperatures at which gases are evolved from solid samples. In addition, the isotopic composition of these gases, particularly when multiple sources contribute to a given EGA curve, may be used to identify possible formation scenarios and relationships between phases. Here we report C and S isotope ratios for CO2 and SO2 evolved from Rocknest soil samples as measured with SAM's quadrupole mass spectrometer (QMS).

Franz, H. B.↗

Isotopic Composition of Carbon Dioxide Released from Confidence Hills Sediment as Measured by the Sample Analysis at Mars (SAM) Quadrupole Mass Spectrometer

In October 2014, the Mars Science Laboratory (MSL) "Curiosity" rover drilled into the sediment at the base of Mount Sharp in a location namsed Cionfidence Hills (CH). CH marked the fifth sample pocessed by the Sample Analysis at Mars (SAM) instrument suite since Curiosity arrived in Gale Crater, with previous analyses performed at Rocknest (RN), John Klein (JK), Cumberland (CB), and Windjana (WJ). Evolved gas analysis (EGA) of all samples has indicated H2O as well as O-, C- and S-bearing phases in the samples, often at abundances that would be below the detection limit of the CheMin instrument. By examining the temperatures at which gases are evolved from samples, SAM EGA data can help provide clues to the mineralogy of volatile-bearing phases when their identities are unclear to CheMin. SAM may also detect gases evolved from amorphous material in solid samples, which is not suitable for analysis by CheMin. Finally, the isotopic composition of these gases may suggest possible formation scenarios and relationships between phases. We will discuss C isotope ratios of CO2 evolved from the CH sample as measured with SAM's quadrupole mass spectrometer (QMS) and draw comparisons to samples previously analyzed by SAM.

Franz, H. B.↗

Carbon and Sulfur Isotopic Composition of Yellowknife Bay Sediments: Measurements by the Sample Analysis at Mars (SAM) Quadrupole Mass Spectrometer

Since landing at Gale Crater in Au-gust 2012, the Sample Analysis at Mars (SAM) instru-ment suite on the Mars Science Laboratory (MSL) “Curiosity” rover has analyzed solid samples from the martian regolith in three locations, beginning with a scoop of aeolian deposits from the Rocknest (RN) sand shadow. Curiosity subsequently traveled to Yellowknife Bay, where SAM analyzed samples from two separate holes drilled into the Sheepbed Mudstone, designated John Klein (JK) and Cumberland (CB). Evolved gas analysis (EGA) of all samples revealed the presence of H2O as well as O-, C- and S-bearing phas-es, in most cases at abundances below the detection limit of the CheMin instrument. In the absence of definitive mineralogical identification by CheMin, SAM EGA data can help provide clues to the mineralogy of volatile-bearing phases through examination of tem-peratures at which gases are evolved from solid sam-ples. In addition, the isotopic composition of these gas-es may be used to identify possible formation scenarios and relationships between phases. Here we report C and S isotope ratios for CO2 and SO2 evolved from the JK and CB mudstone samples as measured with SAM’s quadrupole mass spectrometer (QMS) and draw com-parisons to RN.

Franz, H. B.↗

The charge-energy-mass spectrometer for 0.3-300 keV/e ions on the AMPTE CCE

The charge-energy-mass (CHEM) spectrometer on the Charge Composition Explorer (CCE) has the function to measure the energy spectra, pitch-angle distributions, and ionization states of ions in the earth's magnetosphere and magnetosheath in the energy range from 0.3 to 300 keV/charge with a time resolution of less than 1 min. The obtained data will provide essential information on outstanding problems related to ion sources and dynamical processes of space plasmas and of suprathermal ions. A description of the CHEM experiment is given, taking into account the principle of operation, the sensor, the electronics, instrument characteristics, specifications, and requirements. Questions of postlaunch performance are also discussed.

Gloeckler, G.↗

A Comparison of Quartz Crystal Microbalance Measurements with Mass Spectrometer Determinations

An experimental program was undertaken in which mass accretion rates, as determined by a liquid nitrogen cooled quartz crystal microbalance, were compared with the mass flux rates, as determined by both a cycloidal type and a quadrupole type residual gas analyzer for five simple materials. The data indicate a high degree of correlation between these instruments insofar as the shape of the curves. There are large variations however among the absolute values.

Kruger, R.↗