THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

74 ATOMIC AND MOLECULAR PHYSICS↗

A cosmic ray isotope spectrometer

The paper describes a new instrument to be flown on ISEE-C which is optimized to measure the isotopic composition of solar and galactic cosmic rays in the 5-250 MeV/nucleon range. A mass resolution of not greater than 0.3 AMU should be achieved for all elements with charge Z not exceeding 30.

Althouse, W. E.↗

A maximum likelihood convolutional decoder model vs experimental data comparison

This article describes the comparison of a maximum likelihood convolutional decoder (MCD) prediction model and the actual performance of the MCD at the Madrid Deep Space Station. The MCD prediction model is used to develop a subroutine that has been utilized by the Telemetry Analysis Program (TAP) to compute the MCD bit error rate for a given signal-to-noise ratio. The results indicate that that the TAP can predict quite well compared to the experimental measurements. An optimal modulation index also can be found through TAP.

Chen, R. Y.↗

Design, development, and test of a laser velocimeter for a small 8:1 pressure ratio centrifugal compressor

The instrument was designed as a diagnostic tool for the basic fluid dynamics of the inducer, impeller, and diffuser regions of this type compressor. The LV instrumentation was optimized to measure instantaneous velocities up to approximately 500 m/s, measured in absolute coordinates, within the rotating compressor impeller and in the two dimensional radial plane of the diffuser. Some measurements were made within the diffuser and the impeller inlet flows; however, attempts to make detailed measurements of the velocity field were not successful. Difficulties in maintaining high seed particle rates within the probe volume and the improper operation of the blade gating optics may explain the lack of success. Recommendations are made to further pursue these problems. At 100% speed the stage attained a total static pressure ratio of 7.5:1 at 75% total-static efficiency. Flow range from choke-to-surge was 6.8% of choking mass flow rate. Performance was lower than the design intent of 8:1 pressure ratio at 77% efficiency and 12% flow range. Detailed measurements of the stage components are presented which show the reasons for the stage performance deficiencies.

Dolan, F. X.↗

Filter development for the extreme ultraviolet explorer

Thin film filters with extreme ultraviolet bandpasses unattainable with previously available filter materials were developed. Titanium and antimomy were identified as the most promising materials for providing the scientifically important 350-500 A bandpass heretofore unattainable with thin film filters. Titanium foils and titanium-antimony sandwich foils of the required uniformity and durability were fabricated. Transmission measurements and optimization studies indicate that the titanium-antimony combination provides an ideal bandpass for scientifically valuable, high-sensitivity observations with EUVE. Environmental testing of the mechanical strength, moisture sensitivity and aging characteristics of the newly developed filter materials demonstrate flightworthy performance.

Kimble, R.↗

Testing and optimizing MST coaxial collinear arrays, part 6.4A

Many clear-air VHF wind profiles use coaxial collinear (COCO) arrays for their antenna. A COCO array is composed of long lines of half-wave dipoles spaced one-half wavelength apart. An inexpensive method of checking a COCO array is described and its performance is optimized by measuring and then correcting the relative rf phase among its lines at their feed point. This method also gives an estimate of the rf current amplitude among the lines. The strength and location of the sidelobes in the H-plane of the array can be estimated.

Warnock, J. M.↗

Effects of simulator variations on the fidelity of a UH-60 Black Hawk simulation

The validity of the vertical motion simulator used to simulate the UH-60A Black Hawk helicopter is evaluated. Aircraft simulation of bob-up, hover turn, and dash/quick stop manuevers are compared to actual flight data. The effects of variations in the simulator's visual and motion characteristics on the simulation data are investigated. Data obtained with the nonintrusive parameter identification procedure and optimal control measures are applied to the helicopter math model used for real-time aircraft simulation. Analysis of the model reveals that the simulated aircraft is underdamped, and the changes in the visual reference have the greatest effect on the ability of the pilot to perform the maneuvers.

Cleveland, W. B.↗

CCD charge collection efficiency and the photon transfer technique

The charge-coupled device (CCD) has shown unprecendented performance as a photon detector in the areas of spectral response, charge transfer, and readout noise. Recent experience indicates, however, that the full potential for the CCD's charge collection efficiency (CCE) lies well beyond that which is realized in currently available devices. A definition of CCE performance is presented and a standard test tool (the photon transfer technique) for measuring and optimizing this important CCD parameter is introduced. CCE characteristics for different types of CCDs are compared; the primary limitations in achieving high CCE performance are discussed, and the prospects for future improvement are outlined.

Janesick, J.↗

Improvements in MDC and TWT overall efficiency through the application of carbon electrode surfaces

The effects of secondary electron emission losses on TWT efficiency are investigated and techniques for minimizing these losses are described. The TWT-multistage depressed collector performance was optimized and measured over a wide range of operating conditions using geometrically identical collectors that utilized copper, pyrolytic graphite, and isotropic graphite electrodes. The data reveal that carbon rather than copper electrodes improve the TWT efficiency, and the ion-textured graphite is most effective in minimizing the secondary electron emission losses. It is noted that degradation of the collector efficiency can be limited to a small percentage with the proper MDC design and the use of low secondary electron yield carbon electrode surfaces.

Ramins, Peter↗

The design of trellis codes for fading channels

The appropriate criterion for optimum trellis coded modulation design on the additive white Gaussian noise channel is maximization of the free Euclidean distance. When trellis coded modulation is used on a Rician fading channel with interleaving/deinterleaving, the design of the code for optimum performance is guided by other factors, in particular the length of the shortest error event path, and the product of branch distances (possibly normalized by the Euclidean distance of the path) along that path. Although maximum free distance (d sub free) is still an important consideration, it plays a less significant role the more severe the fading is on the channel. These considerations lead to the definition of a new distance measure for optimization of trellis codes transmitted over Rician fading channels. If no interleaving/deinterleaving is used, then once again the design of the trellis code is guided by maximizing d sub free. It is also shown that allowing for multiple symbols per trellis branch, i.e., multiple trellis coded modulation (MTCM), provides an additional degree of freedom for designing a code to meet the above optimization criteria on the fading channel. It is here where the MTCM technique exploits its full potential.

Divsalar, Dariush↗

The design of trellis coded MPSK for fading channels: Performance criteria

It has been well established that the appropriate criterion for optimum trellis-coded modulation design on the additive white Gaussian noise channel is maximization of the free Euclidean distance. It is shown that when the trellis-coded modulation is used on a Rician fading channel with interleaving/deinterleaving, the design of the code of optimum performance is guided by other factors, in particular, the length of the shortest error-event path, and the product of branch distances (possibly normalized by the Euclidean distance of the path) along the path. Athough maximum free distance (dfree) is still an important consideration, it plays a less significant role the more severe the fading is on the channel. These considerations lead to the definition of a new distance measure of optimization of trellis codes transmitted over Rician fading channels. If no interleaving/deinterleaving is used, then once again the design of the trellis code is guided by maximizing dfree.

Divsalar, Dariush↗

Secondary electron emission characteristics of molybdenum-masked, ion-textured OFHC copper

A method for producing a uniform, highly textured surface on oxygen-free, high conductivity (OFHC) copper by ion bombardment using sputtered molybdenum as a texture-inducing masking film was developed and used to provide samples for study. The purpose was to develop a basically OFHC copper surface having very low secondary electron emission characteristics. Surfaces having low secondary electron emission are a requirement for the electrodes of very high efficiency multistage depressed collectors (MDC's). Such MDC's are used in microwave amplifier traveling wave tubes for space communications and other applications. OFHC copper is the material most commonly used for MDC electrodes because it has high thermal conductivity, it is easy to machine, and its fabrication and brazing procedures are well established. However, its untreated surface displays relatively very high levels of secondary electron emissions. Textured OFHC copper samples were tested for true secondary electron emission and relative reflected primary electron yield at primary electron beam energy levels from 200 to 2000 eV and at direct (0 deg) to oblique (60 deg) beam impingement angles. The test results for three of the samples, each of which was processed in a slightly different way, are compared with each other and with test results for a machined OFHC copper sample. Although the textured samples are not represented here as having been processed optimally, their measured secondary electron emission characteristics are significantly lower than those of the untreated OFHC copper sample over the range of conditions studied. Importantly, the relative reflected primary electron yield of one of the textured samples is conspicuously lower than that of the others. Clearly, with further development, the molybdenum-masked ion-textured OFHC copper surface will be a promising material for high-efficiency MDC electrodes.

Curren, Arthur N.↗

Stochastic prediction techniques for wind shear hazard assessment

The threat of low-altitude wind shear has prompted development of aircraft-based sensors that measure winds directly on the aircraft's intended flight path. Measurements from these devices are subject to turbulence inputs and measurement error, as well as to the underlying wind profile. Stochastic estimators are developed to process on-board Doppler sensor measurements, producing optimal estimates of the winds along the path. A stochastic prediction technique is described to predict the hazard to the aircraft from the estimates as well as the level of uncertainty of the hazard prediction. The stochastic prediction technique is demonstrated in a simulated microburst wind shear environment. Use of the technique in a decision-making process is discussed.

Stratton, D. A.↗

Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

Blake, Donald R.↗

Application of Modern Design of Experiments to CARS Thermometry in a Model Scramjet Engine

We have applied formal experiment design and analysis to optimize the measurement of temperature in a supersonic combustor at NASA Langley Research Center. We used the coherent anti-Stokes Raman spectroscopy (CARS) technique to map the temperature distribution in the flowfield downstream of an 1160 K, Mach 2 freestream into which supersonic hydrogen fuel is injected at an angle of 30 degrees. CARS thermometry is inherently a single-point measurement technique; it was used to map thc flow by translating the measurement volume through the flowfield. The method known as "Modern Design of Experiments" (MDOE) was used to estimate the data volume required, design the test matrix, perform the experiment and analyze the resulting data. MDOE allowed us to match the volume of data acquired to the precision requirements of the customer. Furthermore, one aspect of MDOE, known as response surface methodology, allowed us to develop precise maps of the flowfield temperature, allowing interpolation between measurement points. An analytic function in two spatial variables was fit to the data from a single measurement plane. Fitting with a Cosine Series Bivariate Function allowed the mean temperature to be mapped with 95% confidence interval half-widths of +/- 30 Kelvin, comfortably meeting the confidence of +/- 50 Kelvin specified prior to performing the experiments. We estimate that applying MDOE to the present experiment saved a factor of 5 in data volume acquired, compared to experiments executed in the traditional manner. Furthermore, the precision requirements could have been met with less than half the data acquired.

Danehy, P. M.↗

Global Radius of Curvature Estimation and Control System for Segmented Mirrors

An apparatus controls positions of plural mirror segments in a segmented mirror with an edge sensor system and a controller. Current mirror segment edge sensor measurements and edge sensor reference measurements are compared with calculated edge sensor bias measurements representing a global radius of curvature. Accumulated prior actuator commands output from an edge sensor control unit are combined with an estimator matrix to form the edge sensor bias measurements. An optimal control matrix unit then accumulates the plurality of edge sensor error signals calculated by the summation unit and outputs the corresponding plurality of actuator commands. The plural mirror actuators respond to the actuator commands by moving respective positions of the mixor segments. A predetermined number of boundary conditions, corresponding to a plurality of hexagonal mirror locations, are removed to afford mathematical matrix calculation.

Rakoczy, John M.↗