Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Geostationary Instrument Simulator for Aerosol Observing System Simulation Experiments

In the near future, there will be several new instruments measuring atmospheric composition from geostationary orbit over North America, East Asia, and Europe. This constellation of satellites will provide high resolution, time resolved measurements of trace gases and aerosols for monitoring air quality and tracking pollution sources. This paper describes a detailed, fast, and accurate (less than 1.0% uncertainty) method for calculating synthetic top of the atmosphere (TOA) radiances from a global simulation with a mesoscale free running model, the GEOS-5 Nature Run, for remote sensing instruments in geostationary orbit that measure in the ultraviolet-visible spectral range (UV-Vis). Generating these synthetic observations is the first step of an Observing System Simulation Experiment (OSSE), a framework for evaluating the impact of a new observation or algorithm. This paper provides details of the model sampling, aerosol and cloud optical properties, surface reflectance modeling, Rayleigh scattering calculations, and a discussion of the uncertainties of the simulated TOA radiance. An application for the simulated TOA radiance observations is demonstrated in the manuscript. Simulated TEMPO (Tropospheric Emissions: Monitoring of Pollution) and GOES-R (Geostationary Operational Environmental Satellites) observations were used to show how observations from the two instruments could be combined to facilitate aerosol type discrimination. The results demonstrate the viability of a detailed instrument simulator for radiance measurements in the UV-Vis that is capable of accurately simulating high resolution, time-resolved measurements with reasonable computational efficiency.

Castellanos, Patricia↗

Aeronautic Instruments. Section III : Aircraft Speed Instruments

Part 1 contains a discussion and description of the various types of air speed measuring instruments. The authors then give general specifications and performance requirements with the results of tests on air speed indicators at the Bureau of Standards. Part 2 reports methods and laboratory apparatus used at the Bureau of Standards to make static tests. Methods are also given of combining wind tunnel tests with static tests. Consideration is also given to free flight tests. Part 3 discusses the problem of finding suitable methods for the purpose of measuring the speed of aircraft relative to the ground.

Hunt, Franklin L↗

The Upper Atmosphere Research Satellite (UARS) - An overview

UARS is designed to provide the most extensive data base ever obtained on the coupled energy input, chemistry, and dynamics of the earth's upper atmosphere to increase enormously the current understanding of the upper atmosphere and to improve assessments of the depletion of stratospheric ozone caused by human activities. The UARS mission, observatory, and investigations are described. The UARS experimental investigations consist of energy input experiments, chemical species and temperature experiments, and dynamics experiments. Two instruments measure solar UV energy input while another measures energetic particle energy input and associated X-radiation emission from the atmosphere. Four instruments address chemical concentrations, and two make direct measurements of upper atmosphere winds.

Mcneal, Robert J.↗

Atmospheric monitoring using heterodyne detection techniques

Both passive and active remote-monitoring instruments using discretely tunable infrared gas lasers and heterodyne receivers have been used for measurements of ozone and other trace constituents in the atmosphere. A ground-based solar heterodyne radiometer has been used in discrete spectral regions near 9.5 microns to measure altitude profiles of ozone in both the troposphere and stratosphere. Results indicate that this technique shows promise in providing calibration points for earth-orbiting ozone-measurement instruments. An airborne laser absorption spectrometer has been used to measure tropospheric ozone in two series of flights during the winter and spring of 1977, and these operations are described. Plans are also in progress to fly a balloon-borne heterodyne radiometer during the fall of 1977 in order to measure stratospheric trace species.

Menzies, R. T.↗

SSBUV and NOAA-11 SBUV/2 Solar Variability Measurements

The Shuttle Solar Backscatter Ultraviolet (SSBUV) and NOAA-II Solar Backscatter Ultraviolet/2 (SBUV/2) instruments measured solar spectral Ultraviolet (UV) irradiance during the maximum and declining phase of solar cycle 22. The SSB UV data accurately represent the absolute solar UV irradiance between 200-405 nanometers, and also show the long-term variations during eight flights between October 1989 and January, 1996. These data have been used to correct long-term sensitivity changes in the NOAA-II SBUV/2 data, which provide a near-daily record of solar UV variations over the 170 to 400 nanometer region between December 1988 and October 1994. The NOAA-II data demonstrate the evolution of short-term solar UV activity during solar cycle 22.

Deland, Matthew T.↗

Study on Tribological Properties of CoCrMo Alloys against Metals and Ceramics as Bearing Materials for Artificial Cervical Disc

CoCrMo alloys are believed to be a kind of potential material for artificial cervical disc. However, the tribological properties of CoCrMo alloys against different metals and ceramics are not systematically studied. In this study, the tribological behaviors of CoCrMo alloys against metals (316L, Ti6Al4V) and ceramics (Si{sub 3}N{sub 4}, ZrO{sub 2}) were focused under dry friction and 25 wt.% newborn calf serum (NCS)-lubricated conditions using a ball-on-disc apparatus under reciprocating motion. The microstructure, composition and hardness of CoCrMo alloys were characterized using x-ray diffraction, scanning electron microscopy (SEM) and hardness testers, respectively. The contact angles of the CoCrMo alloys with deionized water and 25 wt.% NCS were measured by the OCA contact angle measuring instrument. The maximum wear width, wear depth and wear volume were measured by three-dimensional white light interference. The morphology and the EDX analysis of the wear marks on CoCrMo alloys were examined by SEM to determine the basic mechanism of friction and wear. The dominant wear mechanism in dry friction for CoCrMo alloys against all pairings was severe abrasive wear, accompanied with a lot of material transfer. Under 25 wt.% NCS-lubricated condition, the wear mechanism for CoCrMo alloys against ceramics (Si{sub 3}N{sub 4}, ZrO{sub 2}) was also mainly severe abrasive wear. However, severe abrasive wear and electrochemical corrosion occurred for the CoCrMo-316L pairing under lubrication. Severe abrasive wear, adhesive wear and electrochemical corrosion occurred for the CoCrMo-Ti6Al4V pairing under lubrication. According to the results, the tribological properties of CoCrMo alloys against ceramics were better than those against metals. The CoCrMo-ZrO{sub 2} pairing displayed the best tribological behaviors and could be taken as a potential candidate bearing material for artificial cervical disc.

36 MATERIALS SCIENCE↗

Binary pseudo-random array for calibration of interferometers with transmission spheres and cylinders

Binary pseudo-random array (BPRA) “white noise” artifacts are highly effective for characterizing the instrument transfer function (ITF) of surface topography metrology tools and wavefront measurement instruments. These BPRA artifacts feature all spatial frequencies within the instrument bandpass equally, resulting in a power spectral density with a white-noise-like character. This characteristic allows for direct ITF determination with uniform sensitivity across the entire spatial frequency range. We have developed a novel BPRA calibration standard that combines the diffractive pattern of a reflection computer-generated hologram (CGH) with the white noise generating BPRA pattern. By integrating these technologies using the same lithographic techniques, the resulting calibration sample enables ITF characterization of a Fizeau interferometer with a transmission sphere, or any nulling optic.

Munechika, K↗

Dynamic response characteristics of two transport models tested in the National Transonic Facility

This paper documents recent experiences with measuring the dynamic response characteristics of a commercial transport and a military transport model during full scale Reynolds number tests in the National Transonic Facility. Both models were limited in angle of attack while testing at full scale Reynolds number and cruise Mach number due to pitch or stall buffet response. Roll buffet (wing buzz) was observed for both models at certain Mach numbers while testing at high Reynolds number. Roll buffet was more severe and more repeatable for the military transport model at cruise Mach number. Miniature strain-gage type accelerometers were used for the first time for obtaining dynamic data as a part of the continuing development of miniature dynamic measurements instrumentation for cryogenic applications. This paper presents the results of vibration measurements obtained for both the commercial and military transport models and documents the experience gained in the use of miniature strain gage type accelerometers.

Young, Clarence P., Jr.↗

A measurement of the cosmic-ray antiproton flux and a search for antihelium

Balloon-borne instrument measurements are presented of the cosmic-ray antiproton flux between 130 and 320 MeV, as well as the results of a search for antihelium between 130 and 370 MeV per nuclear. The antiprotons are found to have a spectral shape similar to the protons, down to about 100 MeV. Calculations of the expected flux of these particles under the assumption that they were created by collisions of high-energy cosmic rays with the interstellar gas, using the standard leaky box model for propagation in the Galaxy, predict a flux two orders of magnitude smaller than that observed. The discrepancy between calculation and experiment may be evidence that cosmic-ray protons have passed through more than 5.0 g/sq cm of material during their lifetime. The search for cosmic-ray antihelium sets a 95% confidence level upper limit on the antihelium/helium ratio of 0.000022.

Buffington, A.↗

Uncertainty Analysis for the Miniaturized Laser Heterodyne Radiometer (mini-LHR)

Presented here is a sensitivity analysis for the miniaturized laser heterodyne radiometer (mini-LHR). This passive, ground-based instrument measures carbon dioxide (CO2) in the atmospheric column and has been under development at NASA/GSFC since 2009. The goal of this development is to produce a low-cost, easily-deployable instrument that can extend current ground measurement networks in order to (1) validate column satellite observations, (2) provide coverage in regions of limited satellite observations, (3) target regions of interest such as thawing permafrost, and (4) support the continuity of a long-term climate record. In this paper an uncertainty analysis of the instrument performance is presented and compared with results from three sets of field measurements. The signal-to-noise ratio (SNR) and corresponding uncertainty for a single scan are calculated to be 329.4+/-1.3 by deploying error propagation through the equation governing the SNR. Reported is an absorbance noise of 0.0024 for 6 averaged scans of field data, for an instrument precision of approximately 0.2 ppmv for CO2.

carbon dioxide (CO2)↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Ames Flight Instrument Group - MARS Exploration Efforts Overview

The NASA Ames Flight Instrument Group (FIG) MARS development activities include Aeolus, an integrated multi-probe mission to observe surface and atmospheric forcing and general circulation of Mars; the Mars Sonic Anemometer (MSA), a sonic-based, in-situ wind measuring instrument and the Saltation Sensor to detect the critical wind stress threshold for sand motion, which is believed to be a key aspect of dust lifting at Mars. These efforts are readying the instruments to fly, and their measurements are regarded as data of high scientific priority for future flight missions. Each of these efforts focuses on addressing a measurement or capability considered critical within the Agency and traceable to the decadal survey and MEPAG Goals. As we elevate the Technology Readiness Level (TRL) of these instruments to 6 through rigorous environmental testing, and participate in forming mission concepts, we make them viable for inclusion in flight mission proposals. Below, we outline FIG's highest priority advancements for Mars exploration.

Mars↗

Multiorder etalon sounder (MOES) development and test for balloon experiment

The Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution has been used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2), the High Resolution Doppler Imager (HRDI), and the Cryogenic Limb Array Etalon Spectrometer (CLAES) flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible and infrared spectral region. The successful space flight of DE-FPI, HRDI, and CLAES on UARS demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory. The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. The combination of FPI and CLIO allows the development of more sensitive Fabry-Perot interferometers in the infrared for the remote sensing of the lower atmospheres of Earth and possibly other planets. The Multiorder Etalon Sounder (MOES), a combination of the rugged etalon and the CLIO, compares very favorably to other space-borne optical instruments in terms of performance versus complexity. The new instrument is expected to be rugged, compact, and very suitable for an operational temperature and moisture sounder. With this technique, the contamination of radiance measurements by emissions of other gases is also minimized. At the Space Physics Research Laboratory (SPRL), the MOES concept and laboratory experiments were worked on for the past several years. Both theoretical studies and laboratory prototype experiments showed that MOES is very competitive compared with other high resolution sounders in terms of complexity and performance and has great potential as a compact and rugged high resolution atmospheric temperature and trace species sounder from the polar platform or the geostationary platform. The logical next step is to convert our laboratory prototype to a balloon instrument, so that field test of MOES can be carried out to prove the feasibility and capability of this new technology. Some of the activities related to the development of MOES for a possible balloon flight demonstration are described. Those research activities include the imaging quality study on the CLIO, the design and construction of a MOES laboratory prototype, the test and calibration of the MOES prototype, and the design of the balloon flight gondola.

Hays, Paul B.↗

Spiral spring/strain gage combination accurately measures shock induced deflection

Spiral springs equipped with strain gages which are hard-wired to readout instrumentation, measure deflection between two relatively inaccessible surfaces in a drop test that causes them to close to near flatness. This technique has been successfully used on Apollo drop tests to measure deflection between aft bulkhead and heatshield.

Berven, B. R.↗

Electron-proton spectrometer: Summary for critical design review

The electron-proton spectrometer (EPS) is mounted external to the Skylab module complex on the command service module. It is designed to make a 2 pi omni-directional measurement of electrons and protons which result from solar flares or enhancement of the radiation belts. The EPS data will provide accurate radiation dose information so that uncertain Relative biological effectiveness factors are eliminated by measuring the external particle spectra. Astronaut radiation safety, therefore, can be ensured, as the EPS data can be used to correct or qualify radiation dose measurements recorded by other radiation measuring instrumentation within the Skylab module complex. The EPS has the capability of measuring and extremely wide dynamic radiation dose rate range, approaching 10 to the 7th power. Simultaneously the EPS has the capability to process data from extremely high radiation fields such as might be encountered in the wake of an intense solar flare.

Source record↗

Parched elasto hydrodynamic lubrication film thickness measurement in an instrument ball bearing

Parched Elasto Hydrodynamic Lubricant (PEHL) film thickness in a large instrument ball bearing is measured by electrical capacitance across its ball set. Correlation is shown between changes in film thickness and changes in Basic Speed Ratio (BSR) measured at the same time. BSR is confirmed as a sensitive, non-intrusive measure of transients in film thickness in a real bearing.

Kingsbury, E.↗

ADEOS Total Ozone Mapping Spectrometer (TOMS) Data Products User's Guide

Two data products from the Total Ozone Mapping Spectrometer (ADEOS/TOMS) have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The ADEOS/ TOMS began taking measurements on September 11, 1996, and ended on June 29, 1997. The instrument measured backscattered Earth radiance and incoming solar irradiance; their ratio was used in ozone retrievals. Changes in the reflectivity of the solar diffuser used for the irradiance measurement were monitored using a carousel of three diffusers, each exposed to the degrading effects of solar irradiation at different rates. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and the drift is less than 0.5 percent over the 9-month data record. The Level 2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level 3 product contains daily total ozone and reflectivity in a 1-degree latitude by 1.25 degrees longitude grid. The Level 3 files containing estimates of UVB at the Earth surface and tropospheric aerosol information will also be available. Detailed descriptions of both HDF data files and the CDROM product are provided.

Krueger, A.↗