Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mixer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Effect of inlet temperature and pressure on emissions from a premixing gas turbine primary zone combustor

Experiments were conducted to determine the performance of a premixing prevaporizing gas turbine primary zone combustor design over a range of combustor inlet temperatures from 700 to 1000 K and a range of inlet pressures from 40 to 240 N/sq cm. The 1 meter long combustor could be operated at pressures up to and including 120 N/sq cm without autoignition in the premixing duct or flashback from the stabilized combustion zone. Autoignition occurred in the mixer tube at the 240 N/sq cm pressure level with an entrance temperature of 830 K and a mixer residence time of 4 msec. Measured NOx level, combustion inefficiency, and hydrocarbon emission index correlated well with adiabatic flame temperature. The NOx levels varied from approximately 0.2 to 2.0 g NO2/kg fuel at combustion inefficiencies from 4 to 0.04 percent, depending upon adiabatic flame temperature and pressure. Measured NOx levels were sensitive to pressure. Tests were made at equivalence ratios ranging from 0.35 to 0.65. The overall total pressure drop for the configuration varied slightly with reference velocity and equivalence ratio, but never exceeded 3 percent.

Roffe, G.↗

Sensitivity limits of an infrared heterodyne spectrometer for astrophysical applications

A discussion and an evaluation of the degradation in sensitivity are given for a heterodyne spectrometer employing a HgCdTe photodiode mixer and tunable diode lasers. The minimum detectable source brightness is considered as a function of the mixer parameters, transmission coefficient of the beam splitter, and local oscillator emission powers. The degradation in the minimum detectable line source brightness that results from the bandwidth being a fraction of the line width is evaluated and plotted as a function of the wavelength and bandwidth for various temperature to mass ratios. It is shown that the minimum achievable degradation in the sensitivity of a practical astronomical heterodyne spectrometer is about 30. Estimates of SNRs with which IR line emission from astronomical sources of interest may be detected are given.

Abbas, M. M.↗

Operation of the SUPARAMP at 33 GHz

A 9-mm degenerate parametric amplifier has been constructed using a linear series array of unbiased Josephson junctions as the active nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable net gain of 15 dB in an instantaneous bandwidth (FWHM) of 3.4 GHz has been achieved. A system noise temperature of 220 plus or minus 5 K (DSB) was measured with a SUPARAMP contribution of only 20 plus or minus 10 K. Output saturation has been observed. This complicates the interpretation of noise-temperature measurements and may render them upper limits. Comparison is made with the results of an earlier 3-cm SUPARAMP.

Chiao, R. Y.↗

Flight effects on JT8D engine jet noise as measured in the NASA Ames 40-by 80-foot wind tunnel

A JT8D-17 turbofan engine was tested in a 40 x 80 ft wind tunnel to determine flight effects on jet noise. The engine was configured as a baseline with conical nozzle, a quiet nacelle 20-lobe ejector/suppressor, and an internal mixer with conical nozzle. Tunnel-off and tunnel-on noise tests were conducted over a range of nozzle pressure ratios (1.2 to 2.1), primary jet velocities (275 to 550 m/s), and tunnel velocities up to 100 m/s. Aft quadrant noise data were measured by a pair of traversing microphones located on a 3-m sideline relative to the engine centerline. Unique correlations and analysis procedures were developed in order to define far-field flight effects from the relatively near-field noise measurements. The ejector/suppressor experienced a significant loss of suppression relative to static measurements during flight while the internal mixer indicated a slight gain in suppression. It is concluded that the wind tunnel is a viable method for studying flight effects on engine jet noise.

Strout, F. G.↗

Femtosecond time-domain phase comparator

Phase shift in test device is measured by summing output of mixer with ramp voltage and comparing time interval between zero crossings of summed signal and ramp reference frequency. Circuit can be used to test devices at other frequencies by changing only signal source, phase splitter, and mixer; divider and time-interval counter need not be driven by oscillator.

Donahoe, T.↗

Altitude test of several afterburner configurations on a turbofan engine with a hydrogen heater to simulate an elevated turbine discharge temperature

A performance test of several experimental afterburner configurations was conducted with a mixed-flow turbofan engine in an altitude facility. The simulated flight conditions were for Mach 1.4 at two altitudes, 12,190 and 14,630 meters. Turbine discharge temperatures of 889 and 1056 K were used. A production afterburner was tested for comparison. The research afterburners included partial forced mixers with V-gutter flameholders, a carburetted V-gutter flameholder, and a triple ring V-gutter flameholder with four swirl-can fuel mixers. Fuel injection variations were included. Performance data shown include augmented thrust ratio, thrust specific fuel consumption, combustion efficiency, and total pressure drop across the afterburner.

Johnsen, R. L.↗

Three-channel integrating analog-to-digital converter

A three-channel integrating analog-to-digital converter was added to the complex mixer system to accept the baseband, complex signals generated by the complex mixers and output binary data to the digital demodulator for further processing and recording. The converter was first used for processing multistation data in radar experiments in the spring of 1977.

Stevens, G. L.↗

Dayem bridge Josephson junctions

The Josephson junction shows great promise as a millimeter wave mixer element. This paper discusses the physical mixing process from a first-order mathematical approach. Design and fabrication of such structures tailored for use in a 80-120 GHz mixer application is presented. Testing of the structures and a discussion of their interpretation is presented.

Barr, D. W.↗

Time domain phase measuring apparatus

The phase and/or period stability of a device is determined by connecting the device in one orthogonal arm of a phase detector having a mixer. In the other arm is an adjustable, variable phase shift device. The output of the mixer is fed through an active low pass filter to derive a DC voltage indicative of the phase shift. The variable phase device is adjusted so that the DC voltage will nullify the phase shift of the tested device under normal conditions. The DC voltage level is converted into a time interval indicative of the phase change of the tested device by determining when the level equals the amplitude of a low frequency ramp voltage. The interval between adjacent equality points can be measured or the period between a reference point on the ramp voltage and the quality be measured.

Reinhardt, V. S.↗

A modular multiple use system for precise time and frequency measurement and distribution

A modular CAMAC based system is described which was developed to meet a variety of precise time and frequency measurement and distribution needs. The system was based on a generalization of the dual mixer concept. By using a 16 channel 100 ns event clock, the system can intercompare the phase of 16 frequency standards with subpicosecond resolution. The system has a noise floor of 26 fs and a long term stability on the order of 1 ps or better. The system also used a digitally controlled crystal oscillator in a control loop to provide an offsettable 5 MHz output with subpicosecond phase tracking capability. A detailed description of the system is given including theory of operation and performance. A method to improve the performance of the dual mixer technique is discussed when phase balancing of the two input ports cannot be accomplished.

Reinhardt, V. S.↗

The low-noise 115-GHz receiver on the Columbia-GISS 4-ft radio telescope

The superheterodyne millimeter-wave radiometer on the Columbia-GISS 4-ft telescope is described. This receiver uses a room-temperature Schottky diode mixer, with a resonant-ring filter as LO diplexer. The diplexer has low signal loss, efficient LO power coupling, and suppresses most of the LO noise at both sidebands. The receiver IF section has a parametric amplifier as its first stage with sufficient gain to overcome the second-stage amplifier noise. A broad-banded quarter-wave impedance transformer minimizes the mismatch between mixer and paramp. At 115 GHz, the SSB receiver noise temperature is 860 K, which is believed to be the lowest figure so far reported for a room-temperature receiver at this frequency.

Cong, H.-I.↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗

Boundary-fitted coordinate systems for arbitrary computational regions

The method of Smith and Wiegel was used to generate meshes for mixer lobes and subsonic inlets that are compatible with flow analysis codes requiring a boundary fitted coordinate system. Successful application of this mesh generator required development of procedures to distribute the mesh points along the boundaries, to regulate the dependence of the connecting function to the local boundary slope, to concentrate the mesh into regions of special interest, and to modify the mesh grid so that it possessed a smooth progression of cell metrics and cell volumes in all directions. The method of Smith and Wiegel when coupled with the extensions mentioned above has proven to be easy to use and control for the inlet and mixer lobe geometries investigated.

Kowalski, E. J.↗

Self-calibrating threshold detector

A self calibrating threshold detector comprises a single demodulating channel which includes a mixer having one input receiving the incoming signal and another input receiving a local replica code. During a short time interval, an incorrect local code is applied to the mixer to incorrectly demodulate the incoming signal and to provide a reference level that calibrates the noise propagating through the channel. A sample and hold circuit is coupled to the channel for storing a sample of the reference level. During a relatively long time interval, the correct replica code provides an output level which ranges between the reference level and a maximum level that represents incoming signal presence and synchronism with the replica code. A summer substracts the stored sample reference from the output level to provide a resultant difference signal indicative of the acquisition of the expected signal.

Barnes, J. R.↗

Trimming epitaxial GaAs Schottky-diode parameters via anodic oxidation

Present day receivers operating at millimeter and sub-millimeter wavelengths most often rely, for their first mixers, on Schottky-barrier diodes formed on epitaxial GaAs. Crucial parameters for these diodes are breakdown voltage, series resistance, junction capacitance and forward conduction mechanism. Some of these are improved, others impaired, by change of epitaxy thickness. This paper describes experience with optimizing GaAs Schottky-diode parameters by anodic oxidation thinning of GaAs epitaxial layers. Monitoring of breakdown voltage of epitaxial GaAs in anodic oxidation solution provides indication of when thinning should be stopped in subjection to the breakdown voltage specification of diodes to be made from the material. Mixer and frequency-multiplier performance superior to any previously reported have been achieved by this technique.

Siegel, C. M.↗

Microwave limb sounder

Trace gases in the upper atmosphere can be measured by comparing spectral noise content of limb soundings with the spectral noise content of cold space. An offset Cassegrain antenna system and tiltable input mirror alternately look out at the limb and up at cold space at an elevation angle of about 22. The mirror can also be tilted to look at a black body calibration target. Reflection from the mirror is directed into a radiometer whose head functions as a diplexer to combine the input radiation and a local ocillator (klystron) beam. The radiometer head is comprised of a Fabry-Perot resonator consisting of two Fabry-Perot cavities spaced a number of half wavelengths apart. Incoming radiation received on one side is reflected and rotated 90 deg in polarization by the resonator so that it will be reflected by an input grid into a mixer, while the klystron beam received on the other side is also reflected and rotated 90 deg, but not without passing some energy to be reflected by the input grid into the mixer.

Gustincic, J. J.↗

Interim review of the Energy Efficient Engine /E3/ Program

The NASA-sponsored Energy Efficient Engine (E3) Program, which is now in its fourth year, is assessed from the viewpoint of one of its research contractors. Attention is given to the development status of the shroudless fan, segmented combustor and exhaust mixer components which are encompassed by the program. The shroudless fan blades are two-thirds hollow for lightness, and are fabricated by means of plies and cores subjected to hot isostatic pressing diffusion bonding. The combustor's segmented liner is cast from turbine blade materials. Exhaust mixer flow visualization tests are described. Consideration is given to the effects of integrating the technology described with the low and high pressure advanced turbines whose development is also part of the E3 program.

Gardner, W. B.↗

Solar driven liquid metal MHD power generator

A solar energy collector focuses solar energy onto a solar oven which is attached to a mixer which in turn is attached to the channel of a MHD generator. Gas enters the oven and a liquid metal enters the mixer. The gas/liquid metal mixture is heated by the collected solar energy and moves through the MHD generator thereby generating electrical power. The mixture is then separated and recycled.

Lee, J. H.↗