Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

An improved physics-based approach for unfolding megavoltage bremsstrahlung spectra using transmission analysis

Purpose: To develop a physics-based approach to improve the accuracy and robustness of the ill-conditioned problem of unfolding megavoltage bremsstrahlung spectra from transmission data. Methods: Spectra are specified using a rigorously-benchmarked functional form. Since ion chambers are the typical detector used in transmission measurements, the energy response of a Farmer chamber is calculated using the EGSnrc Monte Carlo code, and the effect of approximating the energy response on the accuracy of the unfolded spectra is studied. A proposal is introduced to enhance spectral sensitivity by combining transmission data measured with multiple detectors of different energy response and by combining data from multiple attenuating materials. Monte Carlo methods are developed to correct for nonideal exponential attenuation (e.g., scatter effects and secondary attenuation). The performance of the proposed methods is evaluated for a diverse set of validated clinical spectra (3.5-25 MV) using analytical transmission data with simulated experimental noise. Results: The approximations commonly used in previous studies for the ion-chamber energy response lead to significant errors in the unfolded spectra. Of the configurations studied, the one with best spectral sensitivity is to measure four full transmission curves using separate low-Z and high-Z attenuators in conjunction with two detectors of different energy response (the authors propose a Farmer-type ion chamber, once with a low-Z, and once with a high-Z buildup cap material), then to feed the data simultaneously to the unfolding algorithm. Deviations from ideal exponential attenuation are as much as 1.5% for the smallest transmission signals, and the proposed methods properly correct for those deviations. The transmission data with enhanced spectral sensitivity, combined with the accurate and flexible spectral functional form, lead to robust unfolding without requiring a priori knowledge of the spectrum. Compared with the commonly-used methods, the accuracy is improved for the unfolded spectra and for the unfolded mean incident electron kinetic energy by at least factors of three and four, respectively. With simulated experimental noise and a lowest transmission of 1%, the unfolded energy fluence spectra agree with the original spectra with a normalized root-mean-square deviation, %{Delta}({psi}), of 2.3%. The unfolded mean incident electron kinetic energies agree, on average, with the original values within 1.4%. A lowest transmission of only 10% still allows unfolding with %{Delta}({psi}) of 3.3%. Conclusions: In the presence of realistic experimental noise, the proposed approach significantly improves the accuracy and robustness of the spectral unfolding problem for all therapy and MV imaging beams of clinical interest.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo Driven MDI Optimization at a Muon Collider

A Muon Collider represents a very interesting possibility for a future machine to explore the energy frontier in particle physics. However, to reach the needed luminosity, beam intensities of the order of 10⁹–10¹² muons per bunch are needed. In this context, the Beam-Induced Background must be taken into account for its effects on magnets and detector. Several mitigation strategies can however be conceived. In this view, it is of crucial importance to develop a flexible tool that allows to easily reconstruct the machine geometry in a Monte Carlo code, allowing to simulate in detail the interaction of muon decay products in the machine, while being able to change the machine optics itself to find the best configuration. In this contribution, a possible approach to such a purpose is presented, based on FLUKA for the Monte Carlo simulation and on LineBuilder for the geometry reconstruction. Results based on the 1.5 TeV machine optics developed by the MAP collaboration are discussed, as well as a first approach to possible mitigation strategies.

43 PARTICLE ACCELERATORS↗

Implementation of the D1S Methodology for Shutdown Dose Rate Calculations in the OpenMC Monte Carlo Particle Transport Code

We present an implementation of the direct one-step (D1S) methodology for shutdown dose rate (SDR) calculations in the OpenMC Monte Carlo particle transport code. In addition to being the first fully open-source D1S implementation, it is also the first to require no ad hoc source code or nuclear data library modifications. The code can seamlessly switch between production of prompt and decay photons based on a user input parameter, and the decay data needed for decay photon generation are made available through a depletion chain file, which is already used for OpenMC’s built-in depletion/activation solver. A set of Python functions significantly eases the burden of computing and applying time correction factors needed to properly account for the time dependence of radionuclide activity. To assess the accuracy of the D1S implementation, SDR calculations have been carried out for three problems: a prism of iron irradiated by 14-MeV neutrons, the ITER port plug computational benchmark, and the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For each of these problems, comparisons were made to calculations using the rigorous two-step (R2S) method. The results on the iron prism problem illustrate how the D1S method achieves superior spatial resolution compared to the R2S method without the need for spatial discretization of the activation regions. The D1S and R2S results for the ITER port plug benchmark agree well with previously reported results in the literature. While the D1S results are 10% to 15% lower than the R2S results, this may be due to stochastic uncertainty and/or spatial discretization in the R2S calculations. On the FNG dose rate benchmark problem, the D1S method produces dose rate estimates that are within 4% of the dose rates predicted using a cell-based R2S workflow. The D1S estimates of the SDR are also in reasonable agreement with the experimental measurements and show the same basic trends that have been observed in previous works. A qualitative analysis of the execution time and uncertainty for the R2S and D1S workflows suggests that the D1S method would attain a higher figure of merit.

D1S method↗

Fast Reactor Core Analysis Using AZNHEX Neutron Diffusion Code

The AZTLAN platform project emerged as an initiative to rank Mexico at a competitive level in software aspects for the analysis of nuclear reactors, in an effort to achieve autonomy in this area. The AZTLAN platform is conformed by a thermo-hydraulic code (AZTHECA), a neutron transport code (AZTRAN) and two neutron diffusion codes (AZKIND, AZNHEX). AZNHEX is a 3D diffusion code that solves numerically the time dependent neutron diffusion equations in hexagonal z-geometry using the RTN0 nodal finite element method. With this code, it is possible to simulate and analyze light water reactors, such as the Russian VVER, and variety of fast reactors. In this work, a sodium-cooled fast reactor core in steady state, with control rods fully withdrawn, is simulated. The comparison and validation of the values obtained with AZNHEX was done with the results obtained with MCNP6 Monte Carlo code.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PUFFIn – A user friendly fast interface for calculating and visualizing the dose distribution in materials

This article describes a new graphical user interface that uses the PENELOPE Monte Carlo code to calculate dose distributions in materials. It is named PUFFIn, for the Penelope User-Friendly Fast Interface and was developed as an educational and scoping analysis tool for non-experts in radiation modeling. PUFFIn enables the user to visualize and compare the dose distributions in objects (e.g., sterilized healthcare products) irradiated with cobalt-60 gamma-rays, electron beam (E-beam) or X-rays. From such comparisons, the user can determine the most efficient product and/or packaging designs for any given radiation field – whether for conceptual or existing products and packaging. PUFFIn is distributed in a complete, self-contained package of software, including the PENELOPE radiation transport code, a standard graphics package, and a set of simple exercises. The package is available to any user at no cost and requires a minimal amount of training compared to other similar software. PUFFIn's capabilities are described, as well as validation measurements performed at Texas A&M University E-beam facility and the Aerial E-beam Facility in France.

97 MATHEMATICS AND COMPUTING↗

Measurement of DT and DD components in neutron spectrum with a double-crystal time-of-flight spectrometer

To investigate the deuteron and triton density ratio in core plasmas, a new methodology with measurement of tritium (DT) and deuterium (DD) neutron count rate ratio using a double-crystal time-of-flight (TOF) spectrometer is proposed. Multi-discriminator electronic circuits for the first and second detectors are used in addition to the TOF technique. The optimum arrangement of the detectors and discrimination window were examined considering the relations between the geometrical arrangement and deposited energy using a Monte Carlo Code, PHITS (Particle and Heavy Ion Transport Code System). An experiment to verify the calculations was performed using DD neutrons from an accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of the SPERT Transients Using SERPENT2 with Time Dependent Capabilities

Over the last decade, multiphysics coupled calculations have become one of the most important research topics in the area of development and enhancement of reactor analysis and simulation tools. One of the main applications of these coupled simulations is transient analysis, which may involve modeling of experiments, normal plant operation or accident scenarios. Traditionally, the reactor physics side of coupled simulations has been represented by deterministic or hybrid Monte Carlo - deterministic methods. Monte Carlo techniques are limited by their high computational cost. However increased computing power makes their application to multiphysics modeling of transients feasible. Active research is underway to develop algorithms for time dependent calculations, implement them in Monte Carlo codes, and evaluate their performance. In this paper time dependent simulations of the SPERT experiments using the Serpent2 code are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of angularly dependent spectra of betatron gamma-rays from a laser plasma accelerator with quadrant-sectored range filters

Measurement of angularly dependent spectra of betatron gamma-rays radiated by GeV electron beams from laser wakefield accelerators (LWFAs) are presented. The angle-resolved spectrum of betatron radiation was deconvolved from the position dependent data measured for a single laser shot with a broadband gamma-ray spectrometer comprising four-quadrant sectored range filters and an unfolding algorithm, based on the Monte Carlo code GEANT4. The unfolded gamma-ray spectra in the photon energy range of 0.1–10 MeV revealed an approximately isotropic angular dependence of the peak photon energy and photon energy-integrated fluence. As expected by the analysis of betatron radiation from LWFAs, the results indicate that unpolarized gamma-rays are emitted by electrons undergoing betatron motion in isotropically distributed orbit planes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Kinetic Monte Carlo model for material aging: Simulations of second phase formation at Au/Bi{sub 2}Te{sub 3} junction in oxygen environments

Electronic properties of semiconductor devices are sensitive to defects such as second phase precipitates, grain sizes, and voids. These defects can evolve over time especially under oxidation environments and it is therefore important to understand the resulting aging behavior in order for the reliable applications of devices. In this paper, we propose a kinetic Monte Carlo framework capable of simultaneous simulation of the evolution of second phases, precipitates, grain sizes, and voids in complicated systems involving many species including oxygen. This kinetic Monte Carlo model calculates the energy barriers of various events based directly on the experimental data. As a first step of our model implementation, we incorporate the second phase formation module in the parallel kinetic Monte Carlo codes SPPARKS. Selected aging simulations are performed to examine the formation of second phase precipitates at the eletroplated Au/Bi{sub 2}Te{sub 3} interface under oxygen and oxygen-free environments, and the results are compared with the corresponding experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the scattering power of radiotherapy protons

Purpose: First, to show that accurate formulas for scattering power T must take into account the competition between the Gaussian core and the single scattering tail of the angular distribution, which affects the rate of change in the Gaussian width and leads to the single scattering correction (SSC). Second, to show that the SSC requires that T(x) be nonlocal: Besides material properties and energy at the point of interest, it must depend in some fashion on how much multiple scattering has already taken place. Third, after reviewing five previous formulas (three local and two nonlocal), to derive an improved ''differential Moliere'' formula T{sub dM}. Last, to investigate, by studying some practical cases, when an accurate formula for T is actually needed. Methods: We first take the numerical derivative of the Moliere/Fano/Hanson <{theta}{sup 2}> in order to find the true SSC. We simplify the formula for T{sub IC} (ICRU Report 35) for protons, introducing a new material dependent property, the ''scattering length''X{sub S}, analogous to radiation length X{sub 0}. We then use T{sub IC} as a basis for T{sub dM} by including a nonlocal correction factor f{sub dM} which, by virtue of the Oeveraas approximation, parametrizes the single scattering correction. Results: The improved scattering power is T{sub dM}{identical_to}f{sub dM}(pv,p{sub 1}v{sub 1})x(E{sub s}/pv){sup 2}1/X{sub S} where f{sub dM}{identical_to}0.5244+0.1975 lg(1-(pv/p{sub 1}v{sub 1}){sup 2})+0.2320 lg(pv)-0.0098 lg(pv)lg(1-(pv/p{sub 1}v{sub 1}){sup 2}), p{sub 1}v{sub 1} (MeV) is the initial product of proton momentum and speed, pv is the same at the point of interest, and E{sub s}=15.0 MeV. T{sub dM} is easily computed and generalizes readily to mixed slabs because f{sub dM} is not material dependent. Conclusions: Whether an accurate formula for T is required depends very much on the problem at hand. For beam spreading in water, five of the six formulas for T give almost identical results, suggesting that patient dose calculations are insensitive to T. That is not true, however, of beam spreading in Pb. At the opposite extreme, the projected rms beam width at the end of a Pb/Lexan/air stack, analogous to the upstream modulator in a passive beam spreading system, is sensitive to T. In this case a simple experiment would discriminate between all but two of the six formulas discussed. Scattering power applies as much to Monte Carlo as to deterministic transport calculations. Using T in any of its forms will avoid step size dependence. Using the best available T could be important in general purpose Monte Carlo codes, which are expected to give the correct answer to many different problems.

61 RADIATION PROTECTION AND DOSIMETRY↗

A study on the criticality safety for the direct disposal of used nuclear fuel in Japan: Application of burnup credit to the criticality safety evaluation for the disposal canister - 14049

Japan has recently started the technical development of the direct disposal of used nuclear fuel (UNF) to prepare various disposal options. Unlike the disposal of radioactive waste from UNF reprocessing, criticality safety is important here because of the presence of a certain amount of fissile nuclides in UNF. This paper provides an outline of the research to be addressed in this field and the relevant studies in Japan. It especially includes the first result of a criticality safety evaluation of a disposal canister model adopting burnup credit. In this evaluation, it was assumed that a steel disposal canister loaded with fuel assemblies was surrounded by a clay buffer material, and the fuel assemblies and the disposal canister were intact. Conditions representative of discharged pressurized-water reactor (PWR) fuel were applied in this study - initial U-235 enrichment of 4.5 wt% and burnup of 45 GWd/t. The isotopic composition of the burnt fuel was evaluated using SWAT3.1 code. In the depletion calculation, conservative parameters were applied within the typical PWR operation range. The effective neutron multiplication factor (k{sub eff}) was then calculated using a continuous-energy Monte Carlo code MVP-2.0, adopting the JENDL-4.0 nuclear data library. Uncertainty in k{sub eff} due to depletion calculation errors was evaluated using the correction factors of isotopic composition, which were obtained via multiple comparisons between the calculated and measured isotopic concentrations of irradiated fuels. In addition, the effects of axial burnup profile and horizontal burnup gradient on k{sub eff} were evaluated using the open burnup distribution database. The k{sub eff} including the uncertainties and conservatism was found to be below 0.95 for both actinide-only and actinide and fission product considerations when the fuel assemblies and the disposal canister were assumed to be intact. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Software Quality Metrics for Geant4: An Initial Assessment - Paper 122

In the context of critical applications, such as shielding and radiation protection, ensuring the quality of simulation software they depend on is of utmost importance. The assessment of simulation software quality is crucial both to determine its adoption in experimental applications and to guarantee reproducibility of outcome over time. Geant4 is a simulation system used in a wide range of experimental applications, some of which, such as radiation protection and biomedical studies, may involve critical use cases and would especially profit from an objective assessment of the software quality. In this study, we present the first results from an ongoing analysis of Geant4 code based on established software metrics from the perspective of software engineering. The analysis evaluates the current status of the code to quantify its characteristics with respect to documented quality standards; further appraisals concern evolutions over a series of release distributions. The quantitative assessment of the software is initially focused on a subset of Geant4 packages, which play a key role in scientific applications and are representative of different software development processes. We describe the chosen software metrics that map the entities of a software system to numeric values through mathematical definitions, quantifying software attributes ranging from functionality to maintainability. To measure such metrics, we exploited a set of software metrics tools, i.e. programs that implement a set of software metrics definitions. They allow software engineers to assess a software system by extracting the required attributes from the software and providing the corresponding metric values. To correlate software metrics values in a well-defined way, we used software quality standard models, such as the ISO/IEC 9126 standard, which aggregate numerical values to aid quality analysis and assessment. With this work we aim to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. Furthermore, we intend to highlight what metrics are most effective at evaluating radiation transport software quality. We are confident that the result will provide constructive guidance both to improve key software tools, such as Geant4, and to estimate their contribution in risk analysis concerning sensitive applications. The remainder of this paper is structured as follows. We first discuss the approach adopted to fulfil our assessment. Then, we present the setup of our experiments and the way we collected data. We provide an initial interpretation of a subset of data resulting from measurements made on the selected Geant4 packages. As the analysis is still ongoing at the time of submitting this abstract, some results will be documented in the final paper and in the conference presentation. With this work we aim to create a proper Geant4 data set for evaluating its software characteristics and identifying both strengths and weaknesses. In this initial study, we considered the geometry and processes packages, which play a major role in most simulation applications. The data analysis is in progress at the time of writing; its complexity is related to the differences among software metrics tools, to the large amount of data to be evaluated and to the pioneering character of this project. We are confident that the results will provide valuable indications for the Geant4 user community and constructive guidance to improve key Geant4 packages. Other Monte Carlo codes could profit from the methodology developed in this pilot project for similar assessments of their software quality. At the end of this study, we intend to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Back-and-forth approximation as a simple neutron transport model - 14607

The back-and-forth approximation is a very simple neutron transport model that helps get a number of exact solutions which qualitatively describe the actual characteristics of planar, cylindrical and spherical systems with fissile material. The model allows its absolutely accurate implementation in Monte Carlo codes and can be used to test the algorithms which do not treat geometry or interaction data. (author)

42 ENGINEERING↗

Monte Carlo electron-photon transport using GPUs as an accelerator: Results for a water-aluminum-water phantom

An electron-photon coupled Monte Carlo code ARCHER - Accelerated Radiation-transport Computations in Heterogeneous Environments - is being developed at Rensselaer Polytechnic Institute as a software test bed for emerging heterogeneous high performance computers that utilize accelerators such as GPUs. In this paper, the preliminary results of code development and testing are presented. The electron transport in media was modeled using the class-II condensed history method. The electron energy considered ranges from a few hundred keV to 30 MeV. Moller scattering and bremsstrahlung processes above a preset energy were explicitly modeled. Energy loss below that threshold was accounted for using the Continuously Slowing Down Approximation (CSDA). Photon transport was dealt with using the delta tracking method. Photoelectric effect, Compton scattering and pair production were modeled. Voxelised geometry was supported. A serial ARHCHER-CPU was first written in C++. The code was then ported to the GPU platform using CUDA C. The hardware involved a desktop PC with an Intel Xeon X5660 CPU and six NVIDIA Tesla M2090 GPUs. ARHCHER was tested for a case of 20 MeV electron beam incident perpendicularly on a water-aluminum-water phantom. The depth and lateral dose profiles were found to agree with results obtained from well tested MC codes. Using six GPU cards, 6x10{sup 6} histories of electrons were simulated within 2 seconds. In comparison, the same case running the EGSnrc and MCNPX codes required 1645 seconds and 9213 seconds, respectively, on a CPU with a single core used. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in Sensitivity Analysis with MCNP [Slides]

Monte Carlo codes such as MCNP are used extensively in preventing inadvertent nuclear criticalities in processes involving fissionable material. Their ability to do this relies on the accuracy of the simulation tools, the underlying nuclear data libraries, and their validation of relevant experiments. Recent development of an inline method for importance or adjoint weighting with continuous-energy Monte Carlo in MCNP has allowed for the calculation of sensitivity coefficients without the need of meshes or multigroup collapse, unlike previously available tools. These capabilities allow for quantitative comparisons of processes to benchmark experiments and uncertainty quantification for the calculation of biases and safety margins. The current state-of-the-art is discussed, as well as future research avenues.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Burnup calculations for KIPT accelerator driven subcritical facility using Monte Carlo computer codes-MCB and MCNPX.

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of an electron accelerator driven subcritical (ADS) facility, using the KIPT electron accelerator. The neutron source of the subcritical assembly is generated from the interaction of 100 KW electron beam with a natural uranium target. The electron beam has a uniform spatial distribution and electron energy in the range of 100 to 200 MeV. The main functions of the subcritical assembly are the production of medical isotopes and the support of the Ukraine nuclear power industry. Neutron physics experiments and material structure analyses are planned using this facility. With the 100 KW electron beam power, the total thermal power of the facility is {approx}375 kW including the fission power of {approx}260 kW. The burnup of the fissile materials and the buildup of fission products reduce continuously the reactivity during the operation, which reduces the neutron flux level and consequently the facility performance. To preserve the neutron flux level during the operation, fuel assemblies should be added after long operating periods to compensate for the lost reactivity. This process requires accurate prediction of the fuel burnup, the decay behavior of the fission produces, and the introduced reactivity from adding fresh fuel assemblies. The recent developments of the Monte Carlo computer codes, the high speed capability of the computer processors, and the parallel computation techniques made it possible to perform three-dimensional detailed burnup simulations. A full detailed three-dimensional geometrical model is used for the burnup simulations with continuous energy nuclear data libraries for the transport calculations and 63-multigroup or one group cross sections libraries for the depletion calculations. Monte Carlo Computer code MCNPX and MCB are utilized for this study. MCNPX transports the electrons and the produced neutrons and photons but the current version of MCNPX doesn't support depletion/burnup calculation of the subcritical system with the generated neutron source from the target. MCB can perform neutron transport and burnup calculation for subcritical system using external neutron source, however it cannot perform electron transport calculations. To solve this problem, a hybrid procedure is developed by coupling these two computer codes. The user tally subroutine of MCNPX is developed and utilized to record the information of the each generated neutron from the photonuclear reactions resulted from the electron beam interactions. MCB reads the recorded information of each generated neutron thorough the user source subroutine. In this way, the neutron source generated by electron reactions could be utilized in MCB calculations, without the need for MCB to transport the electrons. Using the source subroutines, MCB could get the external neutron source, which is prepared by MCNPX, and perform depletion calculation for the driven subcritical facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗