Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiple Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

On the Error Covariance Correction Step of an ESKF Attitude Update

The attitude states of an error-state Kalman filter (ESKF) behave differently than most other states in the system due to their multiplicative (rather than additive) nature. One way in which they differ is an error covariance correction step after an ESKF error reset, which is not required for, for example, position and velocity states. This covariance correction step is not intuitive, and it has only been recently derived for coordinate transform matrices. The author of this memo, however, found the provided derivation in [1] confusing due to a lack of clarity surrounding the invoked reference frames, and clarity is required as there are at least 4 different ways to parameterize small-angle attitude errors in an ESKF. Furthermore, while reproducing the work, the author of this memo found a more straightforward derivation that provides additional insight into the correction step. This memo offers a derivation of the attitude error covariance correction step of an ESKF, which pays specific attention to the coordinate reference frames.

97 MATHEMATICS AND COMPUTING↗

Measurement and analysis of operating system fault tolerance

This paper demonstrates a methodology to model and evaluate the fault tolerance characteristics of operational software. The methodology is illustrated through case studies on three different operating systems: the Tandem GUARDIAN fault-tolerant system, the VAX/VMS distributed system, and the IBM/MVS system. Measurements are made on these systems for substantial periods to collect software error and recovery data. In addition to investigating basic dependability characteristics such as major software problems and error distributions, we develop two levels of models to describe error and recovery processes inside an operating system and on multiple instances of an operating system running in a distributed environment. Based on the models, reward analysis is conducted to evaluate the loss of service due to software errors and the effect of the fault-tolerance techniques implemented in the systems. Software error correlation in multicomputer systems is also investigated.

Lee, I.↗

UCAC3: ASTROMETRIC REDUCTIONS

Presented here are the details of the astrometric reductions from the x, y data to mean right ascension (R.A.), declination (decl.) coordinates of the third U.S. Naval Observatory CCD Astrograph Catalog (UCAC3). For these new reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey (2MASS) data are used extensively to probe for coordinate and coma-like systematic errors in UCAC data mainly caused by the poor charge transfer efficiency of the 4K CCD. Errors up to about 200 mas have been corrected using complex look-up tables handling multiple dependences derived from the residuals. Similarly, field distortions and sub-pixel phase errors have also been evaluated using the residuals with respect to 2MASS. The overall magnitude equation is derived from UCAC calibration field observations alone, independent of external catalogs. Systematic errors of positions at the UCAC observing epoch as presented in UCAC3 are better corrected than in the previous catalogs for most stars. The Tycho-2 catalog is used to obtain final positions on the International Celestial Reference Frame. Residuals of the Tycho-2 reference stars show a small magnitude equation (depending on declination zone) that might be inherent in the Tycho-2 catalog.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Analysis of Direct-Sequence Code-Division Multiple-Access Communications with Asymmetric Quadrature Phase-Shift-Keying Modulation

This article considers a quaternary direct-sequence code-division multiple-access (DS-CDMA) communication system with asymmetric quadrature phase-shift-keying (AQPSK) modulation for unequal error protection (UEP) capability. Both time synchronous and asynchronous cases are investigated. An expression for the probability distribution of the multiple-access interference is derived. The exact bit-error performance and the approximate performance using a Gaussian approximation and random signature sequences are evaluated by extending the techniques used for uniform quadrature phase-shift-keying (QPSK) and binary phase-shift-keying (BPSK) DS-CDMA systems. Finally, a general system model with unequal user power and the near-far problem is considered and analyzed. The results show that, for a system with UEP capability, the less protected data bits are more sensitive to the near-far effect that occurs in a multiple-access environment than are the more protected bits.

Wang, C.-W.↗

Dynamically accumulated dose and 4D accumulated dose for moving tumors

Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove the principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a 'pulsed beam'; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a 'continuous beam.' A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose difference between the dynamic dose and 4D dose as a function of number of deliveries and/or total deliver time was also established.

60 APPLIED LIFE SCIENCES↗

Self‐Potential Tomography Preconditioned by Particle Swarm Optimization—Application to Monitoring Hyporheic Exchange in a Bedrock River

Abstract A self‐potential (SP) data‐inversion algorithm was developed and tested on an analytical model of electrical‐potential profile data attributed to single and multiple polarized electrical sources. The developed algorithm was then validated by an application to SP‐monitoring field data measured on the floodplain of East Fork Poplar Creek, Oak Ridge, Tennessee, to image electrical sources in areas conducive to preferential flow into the flood plain from the bedrock‐lined riverbed. The algorithm combined stochastic source‐localization by particle‐swarm‐optimization (PSO) of electrical sources characterized by simplified geometries with source tomography by regularized weighted least‐squares minimization of a quadratic objective function. Prior information was incorporated by preconditioning the tomography algorithm by PSO results. Variable percentages of random noise were added to analytical‐model data to evaluate the algorithm performance. Results indicated that true parameters of single‐source models were inverted and approximated with small residual error, whereas inversion of analytical‐model data representing multiple electrical sources accurately approximated the locations of the sources but miscalculated some parameters because of the non‐uniqueness of the inverse‐model solution. Source tomography applied to analytical model data during testing produced a spatially continuous parameter field that identified the locations of point‐scale synthetic dipole sources of electrical current flow with varying degrees of accuracy depending on the prior information incorporated into the tomography. When applied to SP‐monitoring field data, the algorithm imaged electrical sources within a known fault that intersects the bedrock riverbed and flood plain of East Fork Poplar Creek and depicted dynamic electrical conditions attributed to hyporheic exchange.

54 ENVIRONMENTAL SCIENCES↗

Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

42 ENGINEERING↗

A FLUX SCALE FOR SOUTHERN HEMISPHERE 21 cm EPOCH OF REIONIZATION EXPERIMENTS

We present a catalog of spectral measurements covering a 100-200 MHz band for 32 sources, derived from observations with a 64 antenna deployment of the Donald C. Backer Precision Array for Probing the Epoch of Reionization (PAPER) in South Africa. For transit telescopes such as PAPER, calibration of the primary beam is a difficult endeavor and errors in this calibration are a major source of error in the determination of source spectra. In order to decrease our reliance on an accurate beam calibration, we focus on calibrating sources in a narrow declination range from –46° to –40°. Since sources at similar declinations follow nearly identical paths through the primary beam, this restriction greatly reduces errors associated with beam calibration, yielding a dramatic improvement in the accuracy of derived source spectra. Extrapolating from higher frequency catalogs, we derive the flux scale using a Monte Carlo fit across multiple sources that includes uncertainty from both catalog and measurement errors. Fitting spectral models to catalog data and these new PAPER measurements, we derive new flux models for Pictor A and 31 other sources at nearby declinations; 90% are found to confirm and refine a power-law model for flux density. Of particular importance is the new Pictor A flux model, which is accurate to 1.4% and shows that between 100 MHz and 2 GHz, in contrast with previous models, the spectrum of Pictor A is consistent with a single power law given by a flux at 150 MHz of 382 ± 5.4 Jy and a spectral index of –0.76 ± 0.01. This accuracy represents an order of magnitude improvement over previous measurements in this band and is limited by the uncertainty in the catalog measurements used to estimate the absolute flux scale. The simplicity and improved accuracy of Pictor A's spectrum make it an excellent calibrator in a band important for experiments seeking to measure 21 cm emission from the epoch of reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-383: Robustness for Patient Setup Error in Total Body Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

Purpose: Total body irradiation (TBI) and total marrow irradiation (TMI) using Tomotherapy have been reported. A gantry-based linear accelerator uses one isocenter during one rotational irradiation. Thus, 3–5 isocenter points should be used for a whole plan of TBI-VMAT during smoothing out the junctional dose distribution. IGRT provides accurate and precise patient setup for the multiple junctions, however it is evident that some setup errors should occur and affect accuracy of dose distribution in the area. In this study, we evaluated the robustness for patient’s setup error in VMAT-TBI. Methods: VMAT-TBI Planning was performed in an adult whole-body human phantom using Eclipse. Eight full arcs with four isocenter points using 6MV-X were used to cover the entire whole body. Dose distribution was optimized using two structures of patient’s body as PTV and lung. The two arcs were shared with one isocenter and the two arcs were 5 cm-overlapped with the other two arcs. Point absolute dose using ionization-chamber and planer relative dose distribution using film in the junctional regions were performed using water-equivalent slab phantom. In the measurements, several setup errors of (+5∼−5mm) were added. Results: The result of the chamber measurement shows the deviations were within ±3% when the setup errors were within ±3 mm. In the planer evaluation, the pass ratio of gamma evaluation (3%/2mm) shows more than 90% if the errors within ±3 mm. However, there were hot/cold areas in the edge of the junction even with acceptable gamma pass ratio. 5 mm setup error caused larger hot and cold areas and the dosimetric acceptable areas were decreased in the overlapped areas. Conclusion: It can be clinically acceptable for VMAT-TBI when patient setup error is within ±3mm. Averaging effects from patient random error would be helpful to blur the hot/cold area in the junction.

60 APPLIED LIFE SCIENCES↗

Three Decades of Precision Orbit Determination Progress, Achievements, Future Challenges and its Vital Contribution to Oceanography and Climate Research

Although satellite altimetry has been around for thirty years, the last fifteen beginning with the launch of TOPEX/Poseidon (TP) have yielded an abundance of significant results including: monitoring of ENS0 events, detection of internal tides, determination of accurate global tides, unambiguous delineation of Rossby waves and their propagation characteristics, accurate determination of geostrophic currents, and a multi-decadal time series of mean sea level trend and dynamic ocean topography variability. While the high level of accuracy being achieved is a result of both instrument maturity and the quality of models and correction algorithms applied to the data, improving the quality of the Climate Data Records produced from altimetry is highly dependent on concurrent progress being made in fields such as orbit determination. The precision orbits form the reference frame from which the radar altimeter observations are made. Therefore, the accuracy of the altimetric mapping is limited to a great extent by the accuracy to which a satellite orbit can be computed. The TP mission represents the first time that the radial component of an altimeter orbit was routinely computed with an accuracy of 2-cm. Recently it has been demonstrated that it is possible to compute the radial component of Jason orbits with an accuracy of better than 1-cm. Additionally, still further improvements in TP orbits are being achieved with new techniques and algorithms largely developed from combined Jason and TP data analysis. While these recent POD achievements are impressive, the new accuracies are now revealing subtle systematic orbit error that manifest as both intra and inter annual ocean topography errors. Additionally the construction of inter-decadal time series of climate data records requires the removal of systematic differences across multiple missions. Current and future efforts must focus on the understanding and reduction of these errors in order to generate a complete and consistent time series of improved orbits across multiple missions and decades required for the most stringent climate-related research. This presentation discusses the POD progress and achievements made over nearly three decades, and presents the future challenges, goals and their impact on altimetric derived ocean sciences.

Luthcke, Scott↗

Investigating Fission Reaction Rate Ratio Sensitivities [Slides]

One EUCLID project goal is to create a NEW capability in the MCNP6 code. This is being tested on reaction rate sensitivities and compared with SENSMG results. Reaction rate ratio sensitivities were added to EUCLID sensitivity library and investigated to determine value toward designing optimized experiments aimed at reducing compensating errors in nuclear data. The use of adjustment using multiple responses (and underlying/required capabilities) may benefit many applications. These include a tool for adjustment using multiple integral responses (ND adjustment and validation community); sensitivities of additional responses (ND adjustment and validation community); sensitivity capabilities (users in many application areas including safeguards/nonproliferation, criticality safety, etc.); and experiment optimization capability (applications which can benefit from integral experiments). Team is working to build and test future tools and to understand compensating errors

235U↗

RHIC spin flipper AC dipole controller

The RHIC Spin Flipper's five high-Q AC dipoles which are driven by a swept frequency waveform require precise control of phase and amplitude during the sweep. This control is achieved using FPGA based feedback controllers. Multiple feedback loops are used to and dynamically tune the magnets. The current implementation and results will be presented. Work on a new spin flipper for RHIC (Relativistic Heavy Ion Collider) incorporating multiple dynamically tuned high-Q AC-dipoles has been developed for RHIC spin-physics experiments. A spin flipper is needed to cancel systematic errors by reversing the spin direction of the two colliding beams multiple times during a store. The spin flipper system consists of four DC-dipole magnets (spin rotators) and five AC-dipole magnets. Multiple AC-dipoles are needed to localize the driven coherent betatron oscillation inside the spin flipper. Operationally the AC-dipoles form two swept frequency bumps that minimize the effect of the AC-dipole dipoles outside of the spin flipper. Both AC bumps operate at the same frequency, but are phase shifted from each other. The AC-dipoles therefore require precise control over amplitude and phase making the implementation of the AC-dipole controller the central challenge.

43 PARTICLE ACCELERATORS↗

Single-event upset (SEU) in a DRAM with on-chip error correction

Results are given of SEU measurements on 256K dynamic RAMs with on-chip error correction. They are claimed to be the first ever reported. A (12/8) Hamming error-correcting code was incorporated in the layout. Physical separation of the bits in each code word was used to guard against multiple bits being disrupted in any given word. Significant reduction in observed errors is reported.

Zoutendyk, J. A.↗

Adaptive mesh refinement for steady flows in Nek5000

Adaptive mesh refinement is performed in the framework of the spectral element method augmented by approaches to error estimation and control. The h-refinement technique is used for adapting the mesh, where selected grid elements are split by a quadtree (2D) or octree (3D) structure. Continuity between parent-child elements is enforced by high-order interpolation of the solution across the common faces. Parallel mesh partitioning and grid management respectively, are taken care of by the external libraries ParMETIS and p4est. Two methods are considered for estimating and controlling the error of the solution. The first error estimate is local and based on the spectral properties of the solution on each element. This method gives a local measure of the L-2-norm of the solution over the entire computational domain. The second error estimate uses the dual-weighted residuals method - it is based on and takes into account both the local properties of the solution and the global dependence of the error in the solution via an adjoint problem. The objective of this second approach is to optimize the computation of a given functional of physical interest. The simulations are performed by using the code Nek5000 and three steady-state test cases are studied: a two-dimensional lid-driven cavity at Re = 7, 500, a two-dimensional flow past a cylinder at Re = 40, and a three-dimensional lid-driven cavity at Re = 2,000 with a moving lid tilted by an angle of 30 degrees. Finally, the efficiency of both error estimators is compared in terms of refinement patterns and accuracy on the functional of interest. In the case of the adjoint error estimators, the trend on the error of the functional is shown to be correctly represented up to a multiplicative constant.

42 ENGINEERING↗

Modern Palliative Radiation Treatment: Do Complexity and Workload Contribute to Medical Errors?

Purpose: To examine whether treatment workload and complexity associated with palliative radiation therapy contribute to medical errors. Methods and Materials: In the setting of a large academic health sciences center, patient scheduling and record and verification systems were used to identify patients starting radiation therapy. All records of radiation treatment courses delivered during a 3-month period were retrieved and divided into radical and palliative intent. 'Same day consultation, planning and treatment' was used as a proxy for workload and 'previous treatment' and 'multiple sites' as surrogates for complexity. In addition, all planning and treatment discrepancies (errors and 'near-misses') recorded during the same time frame were reviewed and analyzed. Results: There were 365 new patients treated with 485 courses of palliative radiation therapy. Of those patients, 128 (35%) were same-day consultation, simulation, and treatment patients; 166 (45%) patients had previous treatment; and 94 (26%) patients had treatment to multiple sites. Four near-misses and 4 errors occurred during the audit period, giving an error per course rate of 0.82%. In comparison, there were 10 near-misses and 5 errors associated with 1100 courses of radical treatment during the audit period. This translated into an error rate of 0.45% per course. An association was found between workload and complexity and increased palliative therapy error rates. Conclusions: Increased complexity and workload may have an impact on palliative radiation treatment discrepancies. This information may help guide the necessary recommendations for process improvement for patients who require palliative radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of CDMA system capacity for mobile satellite system applications

A specific Direct-Sequence/Pseudo-Noise (DS/PN) Code-Division Multiple-Access (CDMA) mobile satellite system (MSAT) architecture is discussed. The performance of this system is evaluated in terms of the maximum number of active MSAT subscribers that can be supported at a given uncoded bit-error probability. The evaluation decouples the analysis of the multiple-access capability (i.e., the number of instantaneous user signals) from the analysis of the multiple-access mutliplier effect allowed by the use of CDMA with burst-modem operation. We combine the results of these two analyses and present numerical results for scenarios of interest to the mobile satellite system community.

Smith, Partrick O.↗

Use of Existing CAD Models for Radiation Shielding Analysis

The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

Lee, K. T.↗