Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evaluation of the First Transport Rotorcraft Airframe Crash Testbed (TRACT 1) Full-Scale Crash Test

In 2012, the NASA Rotary Wing Crashworthiness Program initiated the Transport Rotorcraft Airframe Crash Testbed (TRACT) research program by obtaining two CH-46E helicopters from the Navy CH-46E Program Office (PMA-226) at the Navy Flight Readiness Center in Cherry Point, North Carolina. Full-scale crash tests were planned to assess dynamic responses of transport-category rotorcraft under combined horizontal and vertical impact loading. The first crash test (TRACT 1) was performed at NASA Langley Research Center's Landing and Impact Research Facility (LandIR), which enables the study of critical interactions between the airframe, seat, and occupant during a controlled crash environment. The CH-46E fuselage is categorized as a medium-lift rotorcraft with fuselage dimensions comparable to a regional jet or business jet. The first TRACT test (TRACT 1) was conducted in August 2013. The primary objectives for TRACT 1 were to: (1) assess improvements to occupant loads and displacement with the use of crashworthy features such as pre-tensioning active restraints and energy absorbing seats, (2) develop novel techniques for photogrammetric data acquisition to measure occupant and airframe kinematics, and (3) provide baseline data for future comparison with a retrofitted airframe configuration. Crash test conditions for TRACT 1 were 33-ft/s forward and 25-ft/s vertical combined velocity onto soft soil, which represent a severe, but potentially survivable impact scenario. The extraordinary value of the TRACT 1 test was reflected by the breadth of meaningful experiments. A total of 8 unique experiments were conducted to evaluate ATD responses, seat and restraint performance, cargo restraint effectiveness, patient litter behavior, and photogrammetric techniques. A combination of Hybrid II, Hybrid III, and ES-2 Anthropomorphic Test Devices (ATDs) were placed in forward and side facing seats and occupant results were compared against injury criteria. Loads from ATDs in energy absorbing seats and restraints were within injury limits. Severe injury was likely for ATDs in forward facing passenger seats, legacy troop bench seats, and a three-tiered patient litter. In addition, two standing ATDs were used to evaluate the benefit of Mobile Aircrew Restraint Systems (MARS) versus a standard gunner's belt. The ATD with the MARS survived the impact, while fatal head blunt trauma occurred for the standing ATD held by the legacy gunner's belt. In addition to occupant loading, the structural response of the airframe was assessed based on accelerometers located throughout the airframe and using three-dimensional photogrammetric techniques. Analysis of the photogrammetric data indicated regions of maximum deflection and permanent deformation.

Annett, Martin S.↗

Evaluation of Impact Energy Attenuators and Composite Material Designs of a UAM VTOL Concept Vehicle

The development of Vertical Take-off and Landing (VTOL) vehicles for the Urban Air Mobility (UAM) markets presents a need for light weight vehicle structures with effective occupant protection capabilities. The National Aeronautics and Space Administration (NASA) has been working to fill that need, recently developing a cadre of concept vehicles to help characterize UAM design feasibility. This paper describes a study, using these concept vehicles, to evaluate the use of advanced composite structure and energy attenuating designs in the UAM vehicle design space. A finite element model (FEM) of a single passenger quadrotor concept vehicle was developed in LS-Dyna® and simulated under nominal and off-nominal vertical impact conditions. A variety of energy attenuating design mechanisms were implemented within this model to quantify their effectiveness in improving occupant safety. The use of carbon composites in both the energy attenuation mechanisms and vehicle structure was evaluated. The results of this study found significant reduction in occupant injury risk with the implementation of energy absorbing composite crush tubes and landing gear within the vehicle design. Additionally the use of a carbon fiber as a structural material was found to provide significant weight reduction while maintaining similar occupant loads to that predicted with an aluminum structure. This work provides a preliminary evaluation of design mechanisms and materials that may be used to optimize occupant protection capabilities within the UAM market.

Putnam, Jacob↗

Safe2Ditch Steer-To-Clear Development and Flight Testing

This paper describes a series of small unmanned aerial system (sUAS) flights performed at NASA Langley Research Center in April and May of 2019 to test a newly added Steer-to-Clear feature for the Safe2Ditch (S2D) prototype system. S2D is an autonomous crash management system for sUAS. Its function is to detect the onset of an emergency for an autonomous vehicle, and to enable that vehicle in distress to execute safe landings to avoid injuring people on the ground or damaging property. Flight tests were conducted at the City Environment Range for Testing Autonomous Integrated Navigation (CERTAIN) range at NASA Langley. Prior testing of S2D focused on rerouting to an alternate ditch site when an occupant was detected in the primary ditch site. For Steer-to-Clear testing, S2D was limited to a single ditch site option to force engagement of the Steer-to-Clear mode. The implementation of Steer-to-Clear for the flight prototype used a simple method to divide the target ditch site into four quadrants. An RC car was driven in circles in one quadrant to simulate an occupant in that ditch site. A simple implementation of Steer-to- Clear was programmed to land in the opposite quadrant to maximize distance to the occupant’s quadrant. A successful mission was tallied when this occurred. Out of nineteen flights, thirteen resulted in successful missions. Data logs from the flight vehicle and the RC car indicated that unsuccessful missions were due to geolocation error between the actual location of the RC car and the derived location of it by the Vision Assisted Landing component of S2D on the flight vehicle. Video data indicated that while the Vision Assisted Landing component reliably identified the location of the ditch site occupant in the image frame, the conversion of the occupant’s location to earth coordinates was sometimes adversely impacted by errors in sensor data needed to perform the transformation. Logged sensor data was analyzed to attempt to identify the primary error sources and their impact on the geolocation accuracy. Three trends were observed in the data evaluation phase. In one trend, errors in geolocation were relatively large at the flight vehicle’s cruise altitude, but reduced as the vehicle descended. This was the expected behavior and was attributed to sensor errors of the inertial measurement unit (IMU). The second trend showed distinct sinusoidal error for the entire descent that did not always reduce with altitude. The third trend showed high scatter in the data, which did not correlate well with altitude. Possible sources of observed error and compensation techniques are discussed.

Petty, Bryan J.↗

Linking human-building interactions in shared offices with personality traits

Occupant behavior influences office building energy performance. The level of human-building interactions (HBIs) in shared offices strongly influences building energy use and occupant well-being. This study explored the link between occupant personality types and their behaviors of sharing energy and environment control systems and interactions with their colleagues. Inspired by the Five-Factor Model (FFM), we classified HBI behaviors into four dimensions: willingness to share control, knowledge of control, group decision behavior, and adaptive strategies. These four variables can be mapped to the four personality traits proposed by the FFM: agreeableness, openness, extraversion, and conscientiousness. Our cluster analysis identified six behavioral patterns: average (17.7%), reserved (15.3%), environmentally friendly (16.6%), role model (24.2%), self-centered (17.2%), and mechanist (9.0%). We further applied association rules, a widely utilized machine learning technique, to discover how demographics, building-related contextual factors, and perception-attitudinal factors influence HBI behaviors. Country, control feature accessibility, and group dynamics were found to be the three most influential factors that determine occupants’ HBI behaviors. Finally, the study provides insights about building design and operation, as well as policy to promote socially and environmentally desirable HBI behaviors in a shared office environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic modeling of the Pd–Zn system with uncertainty quantification and its implication to tailor catalysts

Pd–Zn intermetallic catalysts show encouraging combinations of activity and selectivity on well-defined active site ensembles. Thermodynamic description of the Pd–Zn system, delineating phase boundaries and enumerating site occupancies within intermediate alloy phases, is essential to determining the ensembles of Pd–Zn atoms as a function of composition and temperature. Combining the present extensive first-principles calculations based on density functional theory (DFT) and available experimental data, the Pd–Zn system was remodeled using the CALculation of PHAse Diagrams (CALPHAD) approach. High throughput modeling tools with uncertainty quantification, i.e., ESPEI and PyCalphad, were incorporated in the phase analysis. Here, the site occupancies across the γ phase composition region were given special attention. A four-sublattice model was used for the γ phase owing to its four Wyckoff positions, i.e., the outer tetrahedral (OT) site 8c, the inner tetrahedral (IT) site 8c, the octahedral (OH) site 12e, and the cuboctahedral (CO) site 24g. The site fractions of Pd and Zn calculated from the present thermodynamic model show the occupancy preference of Pd in the OT and OH sublattices in agreement with experimental observations. The force constants obtained from DFT-based phonon calculations further supports the tendency of Pd occupying the OH sublattice compared with the IT and CO sublattice. The catalytic ensembles changing from Pd monomers (Pd 1 ) to trimers (Pd 3 ) on the surface of γ phase are attributed to the increase of Pd occupancy in the OH sublattice.

36 MATERIALS SCIENCE↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Influence of lure choice and survey duration on scent stations for carnivore surveys

Abstract Noninvasive, camera‐based, scent station surveys have become a common approach to estimate population parameters for mammalian carnivores. Many carnivores are particularly sensitive to olfactory cues; and, as such, the quality and quantity of odor attractant used during surveys can significantly affect the accuracy and precision of the survey. Additionally, survey length is also an important consideration because many mammalian predators are highly mobile and elusive in nature. Using scent station surveys in autumn 2013 and 2014 on the Savannah River Site, Aiken, South Carolina, USA, we tested the effects of 5 lures: fatty acid, fish oil, synthetic fermented egg, beaver castor, and skunk essence on visitation rates, visitation probability, and latency to visitation of multiple predator species. We also estimated occupancy probability for 2 carnivore species using different survey lengths to determine the effect of survey period on the precision of occupancy estimates. We found that skunk essence had greater visitation probability and visits than other lures evaluated. Species‐specific bait‐preference models revealed that raccoons ( Procyon lotor ) were more likely to visit skunk essence, and coyotes ( Canis latrans ) were less likely to visit fish oil as compared with fatty acid. Latency to visitation ranged from 104.7 to 112.1 hours and did not vary among scents. Longer survey durations resulted in more precise estimates of occupancy and detection probability. Our results suggest a wide range of scents commonly used for carnivore capture may perform as well as, or better than, fatty acid for noninvasive carnivore surveys. Further, study designs should carefully consider the duration of scent‐station surveys depending on the level of precision desired in estimates of occupancy and detection probability. © 2019 The Wildlife Society.

Webster, Sarah C.↗

A review of smart building sensing system for better indoor environment control

Here this paper aims to provide a systemic review of how indoor sensors influence in managing optimal energy saving, thermal comfort, visual comfort, and indoor air quality in the built environment. The optimal management of energy saving and occupant comfort plays a vital role in the built environment because the occupant's productivity and health are highly influenced by indoor environmental quality. In order to do this, there must be a functional sensing system that connects the environment variables (e.g., temperature) with building environmental control systems such as the heating, ventilation, and air-conditioning system. This paper starts with an overview of the importance of energy saving and occupant comfort in the built environment. It then discusses sensors and their importance in the built environment and reviews the different types of sensors, which explains them in terms of how they influence the indoor built environment and occupant productivity. The paper further explores the application of sensors in the built environment and analyzes this in terms of energy saving, thermal comfort, visual comfort, and indoor air quality. Following this, the data analysis is discussed in terms of data, information, and knowledge accrued from the sensors. Lastly, the paper discusses the future challenges for the improvement of building indoor environmental quality and energy saving by the application of sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface triggered stabilization of metastable charge-ordered phase in SrTiO 3

Charge ordering (CO), characterized by a periodic modulation of electron density and lattice distortion, has been a fundamental topic in condensed matter physics, serving as a potential platform for inducing novel functional properties. The charge-ordered phase is known to occur in a doped system with high d-electron occupancy, rather than low occupancy. Here, we report the realization of the charge-ordered phase in electron-doped (100) SrTiO 3 epitaxial thin films that have the lowest d-electron occupancy i.e., d 1 -d 0 . Theoretical calculation predicts the presence of a metastable CO state in the bulk state of electron-doped SrTiO 3 . Atomic scale analysis reveals that (100) surface distortion favors electron-lattice coupling for the charge-ordered state, and triggering the stabilization of the CO phase from a correlated metal state. This stabilization extends up to six unit cells from the top surface to the interior. Our approach offers an insight into the means of stabilizing a new phase of matter, extending CO phase to the lowest electron occupancy and encompassing a wide range of 3d transition metal oxides.

36 MATERIALS SCIENCE↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The cosmic web of X-ray active galactic nuclei seen through the eROSITA Final Equatorial Depth Survey (eFEDS)

Which galaxies in the general population turn into active galactic nuclei (AGNs) is a keystone of galaxy formation and evolution. Thanks to SRG/eROSITA’s contiguous 140 square degree pilot survey field, we constructed a large, complete, and unbiased soft X-ray flux-limited (FX > 6.5 × 10 -15 erg s -1 cm -2 ) AGN sample at low redshift, 0.05 < z < 0.55. Two summary statistics, the clustering using spectra from SDSS-V and galaxy-galaxy lensing with imaging from HSC, are measured and interpreted with halo occupation distribution and abundance matching models. Both models successfully account for the observations. We obtain an exceptionally complete view of the AGN halo occupation distribution. The population of AGNs is broadly distributed among halos with a mean mass of 3.9 -2.4 +2.0 × 10 12 M ⊙ . This corresponds to a large-scale halo bias of b(z = 0.34) = 0.99 -0.10 +0.08 . The central occupation has a large transition parameter, σ log 10 (M) = 1.28 ± 0.2. The satellite occupation distribution is characterized by a shallow slope, α sat = 0.73 ± 0.38. We find that AGNs in satellites are rare, with f sat < 20%. Most soft X-ray-selected AGNs are hosted by central galaxies in their dark matter halo. A weak correlation between soft X-ray luminosity and large-scale halo bias is confirmed (3.3σ). We discuss the implications of environmental-dependent AGN triggering. This study paves the way toward fully charting, in the coming decade, the coevolution of X-ray AGNs, their host galaxies, and dark matter halos by combining eROSITA with SDSS-V, 4MOST, DESI, LSST, and Euclid data.

79 ASTRONOMY AND ASTROPHYSICS↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

How to optimally constrain galaxy assembly bias: supplement projected correlation functions with count-in-cells statistics

Most models for the statistical connection between galaxies and their haloes ignore the possibility that galaxy properties may be correlated with halo properties other than halo mass, a phenomenon known as galaxy assembly bias. And yet, it is known that such correlations can lead to systematic errors in the interpretation of survey data that are analysed using traditional halo occupation models. At present, the degree to which galaxy assembly bias may be present in the real Universe, and the best strategies for constraining it remain uncertain. We study the ability of several observables to constrain galaxy assembly bias from redshift survey data using the decorated halo occupation distribution (dHOD), an empirical model of the galaxy-halo connection that incorporates assembly bias. We cover an expansive set of observables, including the projected two-point correlation function w p ( r p ), the galaxy-galaxy lensing signal &Delta;Σ( r p ), the void probability function VPF( r ), the distributions of counts-in-cylinders P(NCIC), and counts-in-annuli P(NCIA), and the distribution of the ratio of counts in cylinders of different sizes P ( N 2 /N 5 ). We find that despite the frequent use of the combination w p ( r p ) + &Delta;Σ( r p ) in interpreting galaxy data, the count statistics, P ( N CIC ) and P ( N CIA ), are generally more efficient in constraining galaxy assembly bias when combined with w p ( r p ). Constraints based upon w p ( r p ) and &Delta;Σ(rp) share common degeneracy directions in the parameter space, while combinations of r p w p ( r p ) with the count statistics are more complementary. Therefore, we strongly suggest that count statistics should be used to complement the canonical observables in future studies of the galaxy-halo connection.

galaxies: evolution↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗