ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗

Experimental Design for the LATOR Mission

This paper discusses experimental design for the Laser Astrometric Test Of Relativity (LATOR) mission. LATOR is designed to reach unprecedented accuracy of 1 part in 10(exp 8) in measuring the curvature of the solar gravitational field as given by the value of the key Eddington post-Newtonian parameter gamma. This mission will demonstrate the accuracy needed to measure effects of the next post-Newtonian order (near infinity G2) of light deflection resulting from gravity s intrinsic non-linearity. LATOR will provide the first precise measurement of the solar quadrupole moment parameter, J(sub 2), and will improve determination of a variety of relativistic effects including Lense-Thirring precession. The mission will benefit from the recent progress in the optical communication technologies the immediate and natural step above the standard radio-metric techniques. The key element of LATOR is a geometric redundancy provided by the laser ranging and long-baseline optical interferometry. We discuss the mission and optical designs, as well as the expected performance of this proposed mission. LATOR will lead to very robust advances in the tests of Fundamental physics: this mission could discover a violation or extension of general relativity, or reveal the presence of an additional long range interaction in the physical law. There are no analogs to the LATOR experiment; it is unique and is a natural culmination of solar system gravity experiments.

Turyshev, Slava G.↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

The objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the crystals grown by vapor transport as results of buoyance-driven convection and growth interface fluctuations caused by irregular fluid-flows. ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, were grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals were characterized extensively to correlate the grown crystal properties with the growth conditions. The following are the research progress in the past two years. In-situ monitoring of partial pressure by optical absorption technique and visual observation of the growing crystal were performed during vapor growth of ZnSe. Low-temperature photoluminescence (PL) spectra and glow discharge mass spectroscopy (GDMS) were measured on ZnSe starting materials provided by various vendors and on bulk crystals grown from these starting materials by physical vapor transport (PVT) to study the effects of purification and contamination during crystal growth process. Optical characterization was performed on wafers sliced from the grown crystals of ZnSe, ZnTe and ZnSe(1-x),Te(x), (0<x<0.4). Energy band gaps at room temperature were determined from optical transmission measurements and a best fit curve to the band gap vs. composition, x, data gives a bowing parameter of 1.45. Low-temperature photoluminescence (PL) spectra of ZnSe and ZnTe were dominated by near band edge emissions and no deep donor-acceptor pairs were observed. The PL spectrum exhibited a broad emission for the ZnSe(1-x),Te(x), samples, 0.09<x<0.39. The single broad PL emission spectra and the spectra measured as a function of temperature were interpreted as being associated with the exciton bound to Te clusters because of the high Te content in these samples. To validate numerical codes, in-situ monitoring during the PVT of HgI2 was designed. Optical absorption spectra of the vapor phase over HgI2 were measured for wavelengths between 200 and 600nm at sample temperatures between 349 and 610K. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were determined. From these constants the vapor pressure of HgI2 was established as a function of temperature for the liquid and the solid Beta-phases To characterize the growth conditions during the PVT growth of In-doped ZnSe the optical absorbance of the vapor phase over the In-Se system were measured and were used to obtain the partial pressures of Se2(g) and In2Se(g).

Su, Ching-Hua↗

Evaluation of the interfacial bonding strength between hafnia and silica layers deposited by electron-beam evaporation

Factors contributing to the mechanical strength of multilayer optical coatings involving alternating layers of electron-beam evaporated hafnia and silica is investigated. It is observed that upon rupture resulting from nanosecond laser damage, fragments consisting of layer pairs are produced. These pairs are formed as a result of a strong asymmetry in adhesion strength between interfaces, leading to preferential delamination at interfaces where silica is deposited on hafnia, and not the reverse, despite the fact that both interface types consist of the same pair of materials. The observed disparity in adhesion strength was further studied using nanomechanical scratch tests, revealing loads at which fracture occurs, and fracture morphology, both of which are highly dependent on deposition order. Based on these measurements, along with the morphological analysis of the nanostructure of the coatings, we conclude that the surface microstructure in each coating layer affects its adhesion strength with the succeeding layer. The findings outlined here are particularly relevant to the production of large aperture, high-performance optics designed for use in next-generation lasers.

adhesion strength↗

Lunar Payloads to Constrain Exospheric Water through the NASA M-STAR program

Our understanding of water cycles on the Moon has significantly enhanced recent observations by Chang E-5, Lunar Prospector, and Chandrayaan-1 missions indicating the existence of an active water cycle on the Moon. In a new partnership between Delaware State University (DSU) and NASA Goddard Space Flight Center, enabled through the NASA’s M-STAR (MUREP Space Technology Artemis Research) program, we are developing low mass and power lunar rover payloads to enable long-duration human exploration missions. Payload technologies include wavelength modulation absorption spectroscopy to simultaneously detect water (H16OH) and isotopes (H16OD) in the (6700 nm) mid-infrared region using a closed path in compact Herriot cell optical design and wavelength modulation spectroscopy, and (2) Laser-induced breakdown spectroscopy (LIBS) to simultaneously detect and correlate water isotopes with characteristics elemental composition of lunar regolith. Due to the airless atmosphere of the Moon, we will utilize Artificial intelligence (AI) and Machine learning (ML) approaches to discriminate spectral interference with instrument drifts and correlate mid-IR trace gas profile with LIBS spectral information. This partnership will initiate a STEM engagement space program, e.g., Lander and CubeSat payload technology development for students and the next-generation NASA workforce for future lunar and Mars missions. DSU, a Historically Black University, prides itself in its proven excellence in teaching and research. It enrolls a diverse population of students (~5000) traditionally underrepresented in STEM disciplines. DSU has established itself at the forefront of optics and photonics research that transcends multidisciplinary fields of earth sciences, environmental, defense, and biomedical sensing applications.

water cycles↗

A Dispersive Backend Design for the 'Double-Fourier' Interferometer BETTII

BETTII (Balloon Experimental Twin Telescope for Infra-red Interferometry) is designed to provide high angular resolution spectroscopic data in the far-infrared (FIR) wavelengths. The most significant limitation for BETTII is its sensitivity; obtaining spectral signal-to-noise ratio greater than 5 in less than 10 minutes requires sources greater than 13 Janskys (Jy). One possible way to improve the signal-to-noise ratio (SNR) for future BETTII flights is by reducing the spectral bandwidth post beam-combination. This involves using a dispersive element to spread out a polychromatic point source PSF (Point Spread Function) on the detector array, such that each pixel corresponds to a small fraction of the bandwidth. This results in a broader envelope of the interferometric fringe pattern allowing more fringes to be detected, and thereby improving the spectral SNR. Here we present the analysis and optical design of the dispersive backend, discussing the tradeoffs and how it can be combined with the existing design.

Dhabal, Arnab↗

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

Controlled structures technology and the design of an optical interferometer spacecraft

The impact of extremely stringent structural control requirements and controlled structures techniques on the overall design of a spacecraft system is examined. A space-based optical interferometer presents a design case that necessitates the application of controlled structures technology. In order for interferometry to succeed, differential pathlengths between the optical components need to be identical within a fraction of a wavelength of the light (about 25 nm for visible light). This high level of precision must be maintained on a large, flexible structure in the face of common spacecraft vibrational disturbances. Aspects of spacecraft design are examined to determine the impact of structural control on the 'normal' design process. Structural control objectives can drive several choices in subsystem component selection and sizing that minimize the vibrational environment.

Nisbet, Andrew M.↗

13-kV Ion-Extraction System Being Developed for Inert Gas Ion Engines

A high-voltage ion optics design was chosen for an assumed outer planet or interstellar precursor mission that would require a long-life, high-power, high-specific-impulse krypton ion engine. Such an engine could support energetic space missions to the outer planets or beyond. Detailed performance and lifetime analyses and several inexpensive subscale grid tests were conducted at the NASA Glenn Research Center and at the Colorado State University under a NASA Glenn grant. A subscale grid set of the selected geometry shown was tested at voltages up to 13,000 V. This yielded a krypton ion beam current that would, when scaled to a full-size 50-cm diameter, produce an ion beam with a power of 30 kW at a specific impulse over 14,000 sec. The operational ion beam focusing limits, as a function of ion current per hole, were found to impose requirements of high uniformity on the discharge chamber plasma density. A full-size set of two-grid, 50-cm-diameter titanium ion optics has been fabricated and awaits testing.

Rawlin, Vincent K.↗

James Webb Space Telescope: Large Deployable Cryogenic Telescope in Space

The James Webb Space Telescope (JWST) is an infrared space telescope designed to explore four major science themes: first light and reionization, the assembly of galaxies, the birth of stars and protoplanetary systems, and planetary systems and origins of life. JWST is a segmented architecture telescope with an aperture of 6.6 m. It will operate at cryogenic temperature (40 K), achieved via passive cooling, in an orbit about the Earth-Sun second Lagrange point (L2). Passive cooling is facilitated by means of a large sunshield that provides thermal isolation and protection from direct illumination from the Sun. The large size of the telescope and spacecraft systems require that they are stowed for launch in a configuration that fits the Ariane 5 fairing, and then deployed after launch. Routine wavefront sensing and control measurements are used to achieve phasing of the segmented primary mirror and initial alignment of the telescope. A suite of instruments will provide the capability to observe over a spectral range from 0.6- to 27-micron wavelengths with imaging and spectroscopic configurations. An overview is presented of the architecture and selected optical design features of JWST are described

Lightsey, Paul A.↗

Beam optics ramping in underconstrained lattice design: Application to Electron-Ion Collider hadron storage ring cooling section

This paper presents the lattice design and optics ramping strategy for the cooling section of the hadron storage ring at the electron-ion collider. The main challenge is that available tuning knobs exceed beam-optics constraints. Independently optimized injection and top-energy optics often yield disconnected solutions, making interpolation impossible. To address this, we propose two new methods. The first is an intermediate-penalty scheme that ensures ramping path continuity by penalizing constraint violations at intermediate states. The second is a continuation-based approach that adapts high-energy optics to low energy, guided by an adaptive weighting scheme to balance injection and ramping constraints. The solutions meet all beam dynamics and hardware limits. The two methods offer a general strategy for ramping in systems where the solution space is under-constrained and the starting and target configurations are far apart.

43 PARTICLE ACCELERATORS↗

First-principles investigation of near-field energy transfer between localized quantum emitters in solids

We present a predictive and general approach to investigate near-field energy transfer processes between localized defects in semiconductors, which couples first-principles electronic structure calculations and a nonrelativistic quantum electrodynamics description of photons in the weak-coupling regime. The approach is general and can be readily applied to investigate broad classes of defects in solids. We apply our approach to investigate an exemplar point defect in an oxide, the F center in MgO, and we show that the energy transfer from a magnetic source, e.g., a rare-earth impurity, to the vacancy can lead to spin nonconserving long-lived excitations that are dominant processes in the near field, at distances relevant to the design of photonic devices and ultrahigh dense memories. We also define a descriptor for coherent energy transfer to predict geometrical configurations of emitters to enable long-lived excitations, that are useful to design optical memories in semiconductor and insulators. Published by the American Physical Society 2024

Chattaraj, Swarnabha (ORCID:0000000329333581)↗

OptiMX

OptiMX is a GUI-oriented program with principal aim to be an easy to use, yet comprehensive, interactive accelerator optics design and analysis tool. It was originally developed starting in the 1990s as an MS Windows centric application using the commercial Borland OWL framework. In the spring of 2014, a decision was made to port OptiM to Qt, a modern, portable and open framework. As much as possible, the original interface was preserved.While a significant amount of refactoring was required, the underlying physics has been for the most, left unchanged. The custom plots of the original application have been replaced with functional equivalents based on a stable and well-established library (qwt). With very few minor exceptions the new refactored OptiMX should be a drop-in replacement for the original OWL version.

Lebedev, ValeriA. [Joint Inst. for Nuclear Researc↗

Three-beam hybrid fs/ps coherent anti-Stokes Raman scattering of rotation–vibration non-equilibrium

In this work, we demonstrate time-resolved rotational and vibrational temperature measurements to probe plasma non-equilibrium through a simple three-beam hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system. A single pump/Stokes pair is employed to generate both the pure-rotational and ro-vibrational Raman coherence. A novel phase-matching scheme, to our knowledge, is employed to spatially overlap the two CARS signals, simplifying the optical design and allowing signal selection by tuning a single spectrometer grating. Measurements were performed near the electrodes in a N 2 DC glow discharge. Both the rotational temperature and the vibrational populations up to $v$ = 8 were calculated from the separately measured single-shot pure-rotational and ro-vibrational CARS spectra. Strong rotation–vibration non-equilibrium was observed at both electrodes, with the cathode showing higher vibrational and rotational temperatures. In addition, non-Boltzmann behaviors were observed at both electrodes. This simplified approach enables measurements of rotational and vibrational temperatures with high spatial resolution in non-equilibrium flows.

42 ENGINEERING↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response - CRADA 653 (Abstract)

Light Emitting Diode (LED) adoption is critical for widespread energy savings from commercial outdoor lighting systems. A complaint from the public, concerns glare from LED light fixtures especially those with exposed LED arrays. This human factor study will examine luminance uniformity of the fixture aperture to identify parameters related to this response. The outcome will inform optical design by lighting manufacturers, retaining LED energy efficiency while mitigating glare. The results may also lead to improved industry standard glare metrics for lighting. Pacific Northwest National Laboratory’s (PNNL) Lighting Science and Technology Lab in Portland OR has a purpose-built apparatus with exposed LED arrays that have been used for prior work. It can easily be adapted for use in this experiment. Interchangeable templates will allow changing patterns for the stimulus. Glare ratings from the recruited subjects will be analyzed and reported in a peer-reviewed journal for application by luminaire manufacturers for improved products. The McClung Foundation’s interest is to better understand human perception of lighting, leading to more comfortable and effective visual environments. Members of the Foundation’s Technical Review Committee will be instrumental in reviewing the experimental design, analysis, and the final report. They will also help disseminate information about the results within the lighting community.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗