Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Navigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Optical automatic gain channel

Automatic Gain Control /AGC/ channel automatically compensates for gain changes in the azimuth error channel due to time varying optical sight degrading effects. This system is useful in remote television monitors, automatic navigation systems, and surveying and mapping instrumentation.

Mrus, G.↗

Linear Covariance Analysis for a Lunar Lander

A next-generation lunar lander Guidance, Navigation, and Control (GNC) system, which includes a state-of-the-art optical sensor suite, is proposed in a concept design cycle. The design goal is to allow the lander to softly land within the prescribed landing precision. The achievement of this precision landing requirement depends on proper selection of the sensor suite. In this paper, a robust sensor selection procedure is demonstrated using a Linear Covariance (LinCov) analysis tool developed by Draper.

Jang, Jiann-Woei↗

Augmenting the SCaN Link Budget Tool with Validated Atmospheric Propagation

In any Earth-Space or Space-Earth communications link, atmospheric effects cause significant signal attenuation. In order to develop a communications system that is cost effective while meeting appropriate performance requirements, it is important to accurately predict these effects for the given link parameters. This project aimed to develop a Matlab(TradeMark) (The MathWorks, Inc.) program that could augment the existing Space Communications and Navigation (SCaN) Link Budget Tool with accurate predictions of atmospheric attenuation of both optical and radio-frequency signals according to the SCaN Optical Link Assessment Model Version 5 and the International Telecommunications Union, Radiocommunications Sector (ITU-R) atmospheric propagation loss model, respectively. When compared to data collected from the Advance Communications Technology Satellite (ACTS), the radio-frequency model predicted attenuation to within 1.3 dB of loss for 95 of measurements. Ultimately, this tool will be integrated into the SCaN Center for Engineering, Networks, Integration, and Communications (SCENIC) user interface in order to support analysis of existing SCaN systems and planning capabilities for future NASA missions.

radio frequency communication↗

Addressing the High-Rate Deep Space Communications Shortfall in NASA’s Space Technology Mission Directorate's Envisioned Future

NASA’s Space Technology Mission Directorate (STMD) has identified key technologies needed for future crewed and robotic exploration and science missions. STMD is helping to build the civilian technology base by working with other NASA Mission Directorates, other United States government agencies, commercial industry, and academia to identify technology shortfalls and to develop plans to address them. One critical area of shortfalls lies with deep space communications and navigation. While NASA had huge success to date with the Deep Space Network (DSN), recent studies have shown that without enhancements to current systems, the DSN will be unable to support the anticipated increases in the pace of space exploration or the expected higher data rates from deep space needed soon without severely impacting other missions. High-rate communications from the Moon and beyond is needed to enable future exploration and science missions currently being developed or under consideration. For example, a robust communications infrastructure will be needed to support a sustained human presence on the Moon and its eventual industrialization. High data rate trunk lines between the Earth and the Moon are needed to reduce the number of individual links. The human exploration of Mars will also require high-rate communications between Earth and Mars. Return data rates to Earth from Mars for a single link, for example, are anticipated to be greater than 100 Mb/s; forward data rates to Mars, based on experience from the International Space Station, are anticipated to be greater than 20 Mb/s. Future deep space science missions will also require higher data rates than possible with today’s technology and the current capabilities of the DSN. To support future exploration and science needs, it will be necessary to upgrade the DSN to enhance its radio frequency (RF) capabilities. In addition, it is envisioned that NASA will gradually introduce optical communications to augment its RF systems. Optical communications will enable new science and exploration missions by providing high data rates and better navigation over long distances. This paper will briefly describe STMD’s envisioned future for deep space communications in the 2030+ timeframe and the technology roadmaps being developed for both radio frequency and optical systems.

Bernard Edwards↗

Autonomous navigation preparations for future unmanned space missions

In order to prepare for the era of autonomous navigation, this paper first examines existing techniques for spacecraft navigation by describing the basic elements of the Mark-I and II navigation technologies. The remainder of the paper deals with identification of criteria which necessitate onboard navigation, and with promising solutions now under consideration. An attractive solution possibility is proposed which utilizes narrow-angle optics, a charge-coupled device area-array image sensor, a small advanced onboard flight computer, and a simplified set of software algorithms. Onboard commands would be derived and sent to the appropriate spacecraft attitude control, propulsion, and science platform pointing subsystems. The proposed autonomous navigation system does not address all mission options, but focuses primarily on precision approach trajectory control and adaptive science instrument pointing for asteroid, cometary, and outer planet satellite missions.

Kohlhase, C. E.↗

Contributed Review: The feasibility of a fully miniaturized magneto-optical trap for portable ultracold quantum technology

Experiments using laser cooled atoms and ions show real promise for practical applications in quantum-enhanced metrology, timing, navigation, and sensing as well as exotic roles in quantum computing, networking, and simulation. The heart of many of these experiments has been translated to microfabricated platforms known as atom chips whose construction readily lend themselves to integration with larger systems and future mass production. To truly make the jump from laboratory demonstrations to practical, rugged devices, the complex surrounding infrastructure (including vacuum systems, optics, and lasers) also needs to be miniaturized and integrated. In this paper we explore the feasibility of applying this approach to the Magneto-Optical Trap; incorporating the vacuum system, atom source and optical geometry into a permanently sealed micro-litre system capable of maintaining 10{sup −10} mbar for more than 1000 days of operation with passive pumping alone. We demonstrate such an engineering challenge is achievable using recent advances in semiconductor microfabrication techniques and materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-201-06: Evaluation of Electromagnetically Guided High- Dose Rate Brachytherapy for Ablative Treatment of Lung Metastases

Purpose: The advent of electromagnetic navigation bronchoscopy has enabled minimally invasive access to peripheral lung tumors previously inaccessible by optical bronchoscopes. As an adjunct to Stereotactic Ablative Radiosurgery (SABR), implantation of HDR catheters can provide focal treatments for multiple metastases and sites of retreatments. The authors evaluate a procedure to deliver ablative doses via Electromagnetically-Guided HDR (EMG-HDR) to lung metastases, quantify the resulting dosimetry, and assess its role in the comprehensive treatment of lung cancer. Methods: A retrospective study was conducted on ten patients, who, from 2009 to 2011, received a hypo-fractionated SABR regimen with 6MV VMAT to lesions in various lobes ranging from 1.5 to 20 cc in volume. A CT visible pathway was delineated for EM guided placement of an HDR applicator (catheter) and dwell times were optimized to ensure at least 98% prescription dose coverage of the GTV. Normal tissue doses were calculated using inhomogeneity corrections via a grid-based Boltzmann solver (Acuros-BV-1.5.0). Results: With EMG-HDR, an average of 83% (+/−9% standard deviation) of each patient’s GTV received over 200% of the prescription dose, as compared to SABR where the patients received an average maximum dose of 125% (+/−5%). EMG-HDR enabled a 59% (+/−12%) decrease in the aorta maximum dose, a 63% (+/−26%) decrease in the spinal cord max dose, and 57% (+/−23%) and 70% (+/−17%) decreases in the volume of the body receiving over 50% and 25% of the prescription dose, respectively. Conclusion: EMG-HDR enables delivery of higher ablative doses to the GTV, while concurrently reducing surrounding normal tissue doses. The single catheter approach shown here is limited to targets smaller than 20 cc. As such, the technique enables ablation of small lesions and a potentially safe and effective retreatment option in situations where external beam utility is limited by normal tissue constraints.

60 APPLIED LIFE SCIENCES↗

The Nature of the Effect of Precession-Frequency Mismatch between {sup 129}Xe and {sup 131}Xe Nuclei under Spin-Exchange Pumping by Alkali-Metal Atoms

The effect of precession-frequency mismatch between {sup 129}Xe and {sup 131}Xe xenon-isotope nuclei, which arises under spin-exchange pumping by optically oriented alkali-metal (Cs) atoms and affects the characteristics of measuring and navigation devices based on balanced Schemes with spin-exchange pumping of xenon isotopes, has been investigated. An attempt to explain this effect has been made, and methods for its minimization and elimination have been proposed and experimentally verified.

74 ATOMIC AND MOLECULAR PHYSICS↗

Monitoring stratospheric ozone and aerosols using orbiting photoelectric detectors

Application of slightly modified off-the-shelf automatic celestial navigation systems ('star trackers') is considered for the purposes of monitoring variations in the optical depth of the stratospheric aerosol and ozone layers. The basic principle of the technique is to observe stars from an orbiting station as they are occulted by the stratospheric aerosol layer. Since molecular and refraction extinction are directly calculable, total extinction measurements using a dual-sensor (S4 and S20) approach allows us to directly solve for ozone and aerosol extinction and look for correlations between these two parameters. The technique appears promising for remotely monitoring aerosol and ozone optical depth in the 15-25 km region over selected locations and is independently accurate if aerosol composition and relative size distribution are invariant.

Matloff, G. L.↗

Spacecraft Line-of-Sight Jitter Management and Mitigation Lessons Learned and Engineering Best Practices

Predicting, managing, controlling, and testing spacecraft line-of-sight (LoS) jitter caused by micro-vibrations due to on-board internal disturbance sources is a formidable multidisciplinary engineering task. It is especially challenging for those missions hosting high-performance (e.g., nano-radian/milli-arcsecond class), vibration-sensitive optical sensor payloads with stringent pointing stability requirements. The Nation Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are planning technically aggressive spaceflight missions that include ultra-high-performance optical payloads with delicate, highly vibration-sensitive scientific and observational instruments. The guidance, navigation, and control community of practice will need to leverage collective experiences and document their best practices and lessons learned to address future micro-vibration challenges. To identify lessons learned and best practices the NASA Engineering & Safety Center sponsored a 2-day Spacecraft LoS Jitter Workshop in late 2019. The workshop’s goal was to provide a multidisciplinary forum to elicit deeper understanding of the issues related to addressing the spacecraft LoS jitter/micro-vibration problem. The primary objective was to identify, document, and share lessons learned, best practices, and preferred options for jitter-related analysis and test activities. Representatives from NASA, ESA, along with NASA’s industrial partners, independent consultant subject matter experts, and members of academia participated in the workshop. This paper describes the motivation for the workshop and summarize the identified findings and recommendations.

Lessons Learned↗

NESC GN&C TDT Workshop on 2D Image Motion Optical Transfer Functions, Pointing Performance Analysis, and Requirements

This course was prepared by the author in support of the NASA GN&C Technical Discipline Team (TDT). The purpose of this two-day course is to inform practicing GN&C engineers, and other system and subsystem engineers, including payload engineers and mission analysts, of methodologies to analyze the pointing performance of spacecraft and to write unambiguous pointing requirements that are relevant to optical payload performance. It is hoped that the seminar will contribute to a best-practices manual and contribute to accepted and uniform means of requirements definition, validation, and verification. The course material is designed to address the needs of not only practicing GN&C engineers, but also system and subsystem engineers of other disciplines, payload engineers, mission analysts, and even astronomers who need to understand how they interface to a GN&C subsystem. Much revision is the direct result of active student participation during the presentations and from feedback obtained through course evaluation forms.

2D Image↗

Spacecraft Line-Of-Sight Jitter Management and Mitigation Lessons Learned And Engineering Best Practices

Predicting, managing, controlling, and testing spacecraft line-of-sight (LoS) jitter caused by micro-vibrations due to on-board internal disturbance sources is a formidable multidisciplinary engineering task. It is especially challenging for those missions hosting high-performance (e.g., nano-radian/milli-arcsecond class), vibration-sensitive optical sensor payloads with stringent pointing stability requirements. The Nation Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are planning technically aggressive spaceflight missions that include ultra-high-performance optical payloads with delicate, highly vibration-sensitive scientific and observational instruments. The guidance, navigation, and control community of practice will need to leverage collective experiences and document their best practices and lessons learned to address future micro-vibration challenges. To identify lessons learned and best practices the NASA Engineering & Safety Center sponsored a 2-day Spacecraft LoS Jitter Workshop in late 2019. The workshop’s goal was to provide a multidisciplinary forum to elicit deeper understanding of the issues related to addressing the spacecraft LoS jitter/micro-vibration problem. The primary objective was to identify, document, and share lessons learned, best practices, and preferred options for jitter-related analysis and test activities. Representatives from NASA, ESA, along with NASA’s industrial partners, independent consultant subject matter experts, and members of academia participated in the workshop. This paper will describe the motivation for the workshop and summarize the identified findings and recommendations.

Swanson, Davin K.↗

TICTOC: Compact Atomic Clock with Integrated Photonics.

Atomic clocks are precision timekeeping devices that form the basis for modern communication and navigation. While many atomic clocks are room-sized systems requiring bulky free space optics and detectors, the Trapped-lon Clock using Technology-On-Chip (TICTOC) project integrates these components into Sandia's existing surface trap technology via waveguides for beam delivery and avalanche photodiodes for light detection. Taking advantage of a multi-ensemble clock interrogation approach, we expect to achieve record time stability (< 1 ns error per year) in a compact (< /1 2 L) clock. Here, we present progress on the development of the integrated devices and recent trapped ion demonstrations.

Ivory, Megan Kathleen↗

An analysis of outer planet navigation systems.

Various components of outer planet navigation systems are examined using the Saturn portion of a MJS77 Mission as an example. Special emphasis is placed upon the planet relative and satellite relative orbit determination performance. The effects of constant and stochastic error sources are investigated by means of covariance studies, simulations, and worst case analyses. Preliminary requirements for both the quality of the radiometric and optical data, and for the a priori knowledge of satellite and planetary ephemerides are given for various levels of navigational accuracy. Mission benefits resulting from improved navigational capabilities are discussed.

Ondrasik, V. J.↗

Low-frequency, self-sustained oscillations in inductively coupled plasmas used for optical pumping

We have investigated very low frequency, on the order of one hertz, self-pulsing in alkali-metal inductively-coupled plasmas (i.e., rf-discharge lamps). This self-pulsing has the potential to significantly vary signal-to-noise ratios and (via the ac-Stark shift) resonant frequencies in optically pumped atomic clocks and magnetometers (e.g., the atomic clocks now flying on GPS and Galileo global navigation system satellites). The phenomenon arises from a nonlinear interaction between the atomic physics of radiation trapping and the plasma's electrical nature. To explain the effect, we have developed an evaporation/condensation theory (EC theory) of the self-pulsing phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary error budget for an optical ranging system: Range, range rate, and differenced range observables

Future missions to the outer solar system or human exploration of Mars may use telemetry systems based on optical rather than radio transmitters. Pulsed laser transmission can be used to deliver telemetry rates of about 100 kbits/sec with an efficiency of several bits for each detected photon. Navigational observables that can be derived from timing pulsed laser signals are discussed. Error budgets are presented based on nominal ground stations and spacecraft-transceiver designs. Assuming a pulsed optical uplink signal, two-way range accuracy may approach the few centimeter level imposed by the troposphere uncertainty. Angular information can be achieved from differenced one-way range using two ground stations with the accuracy limited by the length of the available baseline and by clock synchronization and troposphere errors. A method of synchronizing the ground station clocks using optical ranging measurements is presented. This could allow differenced range accuracy to reach the few centimeter troposphere limit.

Folkner, W. M.↗