Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERIPHERAL MODELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Spectra and radial flow in relativistic heavy ion collisions with Tsallis statistics in a blast-wave description

We have implemented the Tsallis statistics in a Blast-Wave model (TBW) and applied it to midrapidity transverse-momentum spectra of identified particles measured at BNL Relativistic Heavy Ion Collider (RHIC). This new TBW function fits the RHIC data very well for p{sub T}<3 GeV/c. We observed that the collective flow velocity starts from zero in p+p and peripheral Au+Au collisions and grows to 0.470{+-}0.009c in central Au+Au collisions. The resulting (q-1) parameter, which characterizes the degree of nonequilibrium in a system, indicates an evolution from a highly nonequilibrated system in p+p collisions toward an almost thermalized system in central Au+Au collisions. The temperature and collective velocity are well described by a quadratic dependence on (q-1). Two sets of parameters in our TBW are required to describe the meson and baryon groups separately in p+p collisions while one set appears to fit all spectra in central Au+Au collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-D-16A-06: Modeling Biological Effects of Residual Uncertainties For Stereotactic Radiosurgery

Purpose: Residual uncertainties on the order of 1-2 mm are frequently observed when delivering stereotactic radiosurgery via on-line imaging guidance with a relocatable frame. In this study, a predictive model was developed to evalute potentiral late radiation effects associated with such uncertainties. Methods: A mathematical model was first developed to correlate the peripherial isodose volume with the internal and/or setup margins for a radiosurgical target. Such a model was then integrated with a previoulsy published logistic regression normal tissue complication model for determining the symptomatic radiation necrosis rate at various target sizes and prescription dose levels. The model was tested on a cohort of 15 brain tumor and tumor resection cavity patient cases and model predicted results were compared with the clinical results reported in the literature. Results: A normalized target diameter (D{sub 0}) in term of D{sub 0} = 6V/S, where V is the volume of a radiosurgical target and S is the surface of the target, was found to correlate excellently with the peripheral isodose volume for a radiosurgical delivery (logarithmic regression R{sup 2} > 0.99). The peripheral isodose volumes were found increase rapidly with increasing uncertainties levels. In general, a 1-mm residual uncertainties as calculated to result in approximately 0.5%, 1%, and 3% increases in the symptomatic radiation necrosis rate for D{sub 0} = 1 cm, 2 cm, and 3 cm based on the prescription guideline of RTOG 9005, i.e., 21 Gy to a lesion of 1 cm in diameter, 18 Gy to a lesion 2 cm in diameter, and 15 Gy to a lesion 3 cm in diameter respectively. Conclusion: The results of study suggest more stringent criteria on residual uncertainties are needed when treating a large target such as D{sub 0}≤ 3 cm with stereotactic radiosurgery. Dr. Ma and Dr. Sahgal are currently serving on the board of international society of stereotactic radiosurgery (ISRS)

60 APPLIED LIFE SCIENCES↗

Geochemical Enhancement Of Enhanced Geothermal System Reservoirs: An Integrated Field And Geochemical Approach

The geochemical effects of injecting fluids into geothermal reservoirs are poorly understood and may be significantly underestimated. Decreased performance of injection wells has been observed in several geothermal fields after only a few years of service, but the reasons for these declines has not been established. This study had three primary objectives: 1) determine the cause(s) of the loss of injectivity; 2) utilize these observations to constrain numerical models of water-rock interactions; and 3) develop injection strategies for mitigating and reversing the potential effects of these interactions. In this study rock samples from original and redrilled injection wells at Coso and the Salton Sea geothermal fields, CA, were used to characterize the mineral and geochemical changes that occurred as a result of injection. The study documented the presence of mineral scales and at both fields in the reservoir rocks adjacent to the injection wells. At the Salton Sea, the scales consist of alternating layers of fluorite and barite, accompanied by minor anhydrite, amorphous silica and copper arsenic sulfides. Amorphous silica and traces of calcite were deposited at Coso. The formation of silica scale at Coso provides an example of the effects of untreated (unacidified) injectate on the reservoir rocks. Scanning electron microscopy and X-ray diffractometry were used to characterize the scale deposits. The silica scale in the reservoir rocks at Coso was initially deposited as spheres of opal-A 1-2 micrometers in diameter. As the deposits matured, the spheres coalesced to form larger spheres up to 10 micrometer in diameter. Further maturation and infilling of the spaces between spheres resulted in the formation of plates and sheets that substantially reduce the original porosity and permeability of the fractures. Peripheral to the silica deposits, fluid inclusions with high water/gas ratios provide a subtle record of interactions between the injectate and reservoir rocks. In contrast, fluid inclusions trapped prior to injection are relatively gas rich. These results suggest that the rocks undergo extensive microfracturing during injection and that the composition of the fluid inclusions will be biased toward the youngest event. Interactions between the reservoir rocks and injectate were modeled using the non-isothermal reactive geochemical transport code TOUGHREACT. Changes in fluid pH, fracture porosity, fracture permeability, fluid temperature, and mineral abundances were monitored. The simulations predict that amorphous silica will precipitate primarily within a few meters of the injection well and that mineral deposition will lead to rapid declines in fracture porosity and permeability, consistent with field observations. In support of Enhanced Geothermal System development, petrologic studies of Coso well 46A-19RD were conducted to determine the regions that are most likely to fail when stimulated. These studies indicate that the most intensely brecciated and altered rocks in the zone targeted for stimulation (below 10,000 ft (3048 m)) occur between 11,200 and 11,350 ft (3414 and 3459 m). This zone is interpreted as a shear zone that initially juxtaposed quartz diorite against granodiorite. Strong pervasive alteration and veining within the brecciated quartz diorite and granodiorite suggest this shear zone was permeable in the past. This zone of weakness was subsequently exploited by a granophyre dike whose top occurs at 11,350 ft (3459 m). The dike is unaltered. We anticipate, based on analysis of the well samples that failure during stimulation will most likely occur on this shear zone.

15 GEOTHERMAL ENERGY↗

MAGIC GAMMA-RAY TELESCOPE OBSERVATION OF THE PERSEUS CLUSTER OF GALAXIES: IMPLICATIONS FOR COSMIC RAYS, DARK MATTER, AND NGC 1275

The Perseus galaxy cluster was observed by the MAGIC Cherenkov telescope for a total effective time of 24.4 hr during 2008 November and December. The resulting upper limits on the gamma-ray emission above 100 GeV are in the range of 4.6-7.5 x 10{sup -12} cm{sup -2} s{sup -1} for spectral indices from -1.5 to -2.5, thereby constraining the emission produced by cosmic rays, dark matter annihilations, and the central radio galaxy NGC 1275. Results are compatible with cosmological cluster simulations for the cosmic-ray-induced gamma-ray emission, constraining the average cosmic ray-to-thermal pressure to <4% for the cluster core region (<8% for the entire cluster). Using simplified assumptions adopted in earlier work (a power-law spectrum with an index of -2.1, constant cosmic ray-to-thermal pressure for the peripheral cluster regions while accounting for the adiabatic contraction during the cooling flow formation), we would limit the ratio of cosmic ray-to-thermal energy to E{sub CR}/E{sub th} < 3%. Improving the sensitivity of this observation by a factor of about 7 will enable us to scrutinize the hadronic model for the Perseus radio mini-halo: a non-detection of gamma-ray emission at this level implies cosmic ray fluxes that are too small to produce enough electrons through hadronic interactions with the ambient gas protons to explain the observed synchrotron emission. The upper limit also translates into a level of gamma-ray emission from possible annihilations of the cluster dark matter (the dominant mass component) that is consistent with boost factors of {approx}10{sup 4} for the typically expected dark matter annihilation-induced emission. Finally, the upper limits obtained for the gamma-ray emission of the central radio galaxy NGC 1275 are consistent with the recent detection by the Fermi-LAT satellite. Due to the extremely large Doppler factors required for the jet, a one-zone synchrotron self-Compton model is implausible in this case. We reproduce the observed spectral energy density by using the structured jet (spine-layer) model which has previously been adopted to explain the high-energy emission of radio galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Cutaneous exposure to vesicant phosgene oxime: Acute effects on the skin and systemic toxicity

Phosgene Oxime (CX), an urticant or nettle agent categorized as a vesicant, is a potential chemical warfare and terrorist weapon. Its exposure can result in widespread and devastating effects including high mortality due to its fast penetration and ability to cause immediate severe cutaneous injury. It is one of the least studied chemical warfare agents with no effective therapy available. Thus, our goal was to examine the acute effects of CX following its cutaneous exposure in SKH-1 hairless mice to help establish a relevant injury model. Results from our study show that topical cutaneous exposure to CX vapor causes blanching of exposed skin with an erythematous ring, necrosis, edema, mild urticaria and erythema within minutes after exposure out to 8 h post-exposure. These clinical skin manifestations were accompanied with increases in skin thickness, apoptotic cell death, mast cell degranulation, myeloperoxidase activity indicating neutrophil infiltration, p53 phosphorylation and accumulation, and an increase in COX-2 and TNFα levels. Topical CX-exposure also resulted in the dilatation of the peripheral vessels with a robust increase in RBCs in vessels of the liver, spleen, kidney, lungs and heart tissues. These events could cause a drop in blood pressure leading to shock, hypoxia and death. Together, this is the first report on effects of CX cutaneous exposure, which could help design further comprehensive studies evaluating the acute and chronic skin injuries from CX topical exposure and elucidate the related mechanism of action to aid in the identification of therapeutic targets and mitigation of injury. - Highlights: • Phosgene oxime cutaneous exposure causes skin blanching, edema and urticaria. • Penetration of phosgene oxime causes dilation of vasculature in internal organs. • Mast cells could play an important role in phosgene oxime-induced skin injury. • Phosgene oxime could induce low blood pressure and hypoxia leading to mortality. • Data is significant for developing a phosgene oxime-induced skin injury model.

60 APPLIED LIFE SCIENCES↗

An Isoprene Lipid-Binding Protein Promotes Eukaryotic Coenzyme Q Biosynthesis

The biosynthesis of coenzyme Q presents a paradigm for how cells surmount hydrophobic barriers in lipid biology. In eukaryotes, CoQ precursors—among nature’s most hydrophobic molecules—must somehow be presented to a series of enzymes peripherally associated with the mitochondrial inner membrane. Here in this paper, we reveal that this process relies on custom lipid-binding properties of COQ9. We show that COQ9 repurposes the bacterial TetR fold to bind aromatic isoprenes with high specificity, including CoQ intermediates that likely reside entirely within the bilayer. We reveal a process by which COQ9 associates with cardiolipin-rich membranes and warps the membrane surface to access this cargo. Finally, we identify a molecular interface between COQ9 and the hydroxylase COQ7, motivating a model whereby COQ9 presents intermediates directly to CoQ enzymes. Overall, our results provide a mechanism for how a lipid-binding protein might access, select, and deliver specific cargo from a membrane to promote biosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Chiral phase transition in peripheral heavy-ion collisions

It has been recently realized that in peripheral heavy-ion collisions at high energies, a sizable magnetic field is produced in the interaction region. Although this field becomes weak at the proper times when the chiral phase transition is believed to occur, it is still significant so as to ask whether it influences such transition. We use the linear sigma model to study the chiral phase transition in the presence of weak magnetic fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Fractionation in Stereotactic Body Radiation Therapy Using the Linear Quadratic Model

Purpose: To examine the fractionation effect of stereotactic body radiation therapy with a heterogeneous dose distribution. Methods: Derived from the linear quadratic formula with measurements from a hypothetical 2-cm radiosurgical tumor, the threshold percentage was defined as (α/β{sub tissue}/α/β{sub tumor}), the balance α/β ratio was defined as (prescription dose/tissue tolerance*α/β{sub tumor}), and the balance dose was defined as (tissue tolerance/threshold percentage). Results: With increasing fractions and equivalent peripheral dose to the target, the biological equivalent dose of “hot spots” in a target decreases. The relative biological equivalent doses of serial organs decrease only when the relative percentage of its dose to the prescription dose is above the threshold percentage. The volume of parallel organs at risk decreases only when the tumor's α/β ratio is above the balance α/β ratio and the prescription dose is lower than balance dose. Conclusions: The potential benefits of fractionation in stereotactic body radiation therapy depend on the complex interplay between the total dose, α/β ratios, and dose differences between the target and the surrounding normal tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship Between Radiation-Induced Apoptosis of T Lymphocytes and Chronic Toxicity in Patients With Prostate Cancer Treated by Radiation Therapy: A Prospective Study

Purpose: To assess the correlation of radiation-induced apoptosis in vitro of CD4 and CD8 T lymphocytes with late toxicity of prostate cancer patients treated with radiation therapy. Methods and Materials: 214 patients were prospectively included in the study. Peripheral blood was drawn from patients before treatment and irradiated with 8 Gy. The percentage of CD4+ and CD8+ T lymphocytes that underwent radiation-induced apoptosis was assessed by flow cytometry. Toxicity and mortality were correlated in 198 cases with pretreatment apoptosis and clinical and biological variables by use of a Cox proportional hazards model. Results: The mean percentage of CD4+ and CD8+ T lymphocyte radiation-induced apoptosis was 28.58% (±14.23) and 50.76% (±18.9), respectively. Genitourinary (GU) toxicity was experienced by 39.9% of patients, while gastrointestinal (GI) toxicity was experienced by 19.7%. The probability of development of GU toxicity was nearly doubled (hazard ratio [HR] 1.99, P=.014) in those patients in whom the percentage of in vitro radiation-induced apoptosis of CD4+ T-lymphocytes was ≤28.58%. It was also almost double in patients who received doses ≥50 Gy in 65% of the bladder volume (V65 ≥50) (HR 1.92, P=.048). No correlation was found between GI toxicity and any of the variables studied. The probability of death during follow-up, after adjustment for different variables, was 2.7 times higher in patients with a percentage of CD8+ T lymphocyte apoptosis ≤50.76% (P=.022). Conclusions: In conclusion, our study shows, in the largest prospective cohort of prostate cancer patients undergoing radiation therapy, that in vitro radiation-induced apoptosis of CD4+ T lymphocytes assessed before radiation therapy was associated with the probability of developing chronic GU toxicity. In addition, the radiation dose received in the urinary bladder (V65 ≥50) affected the occurrence of GU toxicity. Finally, we also demonstrate that radiation-induced apoptosis of CD8+ T lymphocytes was associated with overall survival, although larger series are needed to confirm this finding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Event-by-event mean p T fluctuations in pp and Pb–Pb collisions at the LHC

Event-by-event fluctuations of the mean transverse momentum of charged particles produced in pp collisions at √s = 0.9, 2.76 and 7 TeV, and Pb–Pb collisions at √ s NN = 2.76 TeV are studied as a function of the charged-particle multiplicity using the ALICE detector at the LHC. Dynamical fluctuations indicative of correlated particle emission are observed in all systems. The results in pp collisions show little dependence on collision energy. The Monte Carlo event generators PYTHIA and PHOJET are in qualitative agreement with the data. Peripheral Pb–Pb data exhibit a similar multiplicity dependence as that observed in pp. In central Pb–Pb, the results deviate from this trend, featuring a significant reduction of the fluctuation strength. The results in Pb–Pb are in qualitative agreement with previous measurements in Au–Au at lower collision energies and with expectations from models that incorporate collective phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryo-EM structures provide insight into how E. coli F 1 F o ATP synthase accommodates symmetry mismatch

F 1 F o ATP synthase functions as a biological rotary generator that makes a major contribution to cellular energy production. It comprises two molecular motors coupled together by a central and a peripheral stalk. Proton flow through the F o motor generates rotation of the central stalk, inducing conformational changes in the F 1 motor that catalyzes ATP production. Here we present nine cryo-EM structures of E. coli ATP synthase to 3.1–3.4 Å resolution, in four discrete rotational sub-states, which provide a comprehensive structural model for this widely studied bacterial molecular machine. We observe torsional flexing of the entire complex and a rotational sub-step of F o associated with long-range conformational changes that indicates how this flexibility accommodates the mismatch between the 3- and 10-fold symmetries of the F 1 and F o motors. We also identify density likely corresponding to lipid molecules that may contribute to the rotor/stator interaction within the F o motor.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Report: Evaluation of peripheral dose for flattening filter free photon beams

Purpose: To develop a comprehensive peripheral dose (PD) dataset for the two unflattened beams of nominal energy 6 and 10 MV for use in clinical care. Methods: Measurements were made in a 40 × 120 × 20 cm{sup 3} (width × length × depth) stack of solid water using an ionization chamber at varying depths (dmax, 5, and 10 cm), field sizes (3 × 3 to 30 × 30 cm{sup 2}), and distances from the field edge (5–40 cm). The effects of the multileaf collimator (MLC) and collimator rotation were also evaluated for a 10 × 10 cm{sup 2} field. Using the same phantom geometry, the accuracy of the analytic anisotropic algorithm (AAA) and Acuros dose calculation algorithm was assessed and compared to the measured values. Results: The PDs for both the 6 flattening filter free (FFF) and 10 FFF photon beams were found to decrease with increasing distance from the radiation field edge and the decreasing field size. The measured PD was observed to be higher for the 6 FFF than for the 10 FFF for all field sizes and depths. The impact of collimator rotation was not found to be clinically significant when used in conjunction with MLCs. AAA and Acuros algorithms both underestimated the PD with average errors of −13.6% and −7.8%, respectively, for all field sizes and depths at distances of 5 and 10 cm from the field edge, but the average error was found to increase to nearly −69% at greater distances. Conclusions: Given the known inaccuracies of peripheral dose calculations, this comprehensive dataset can be used to estimate the out-of-field dose to regions of interest such as organs at risk, electronic implantable devices, and a fetus. While the impact of collimator rotation was not found to significantly decrease PD when used in conjunction with MLCs, results are expected to be machine model and beam energy dependent. It is not recommended to use a treatment planning system to estimate PD due to the underestimation of the out-of-field dose and the inability to calculate dose at extended distances due to the limits of the dose calculation matrix.

60 APPLIED LIFE SCIENCES↗

Beam losses from ultra-peripheral nuclear collisions between Pb ions in the Large Hadron Collider and their alleviation

Electromagnetic interactions between colliding heavy ions at the Large Hadron Collider (LHC) at CERN will give rise to localized beam losses that may quench superconducting magnets, apart from contributing significantly to the luminosity decay. To quantify their impact on the operation of the collider, we have used a three-step simulation approach, which consists of optical tracking, a Monte-Carlo shower simulation and a thermal network model of the heat flow inside a magnet. We present simulation results for the case of {sup 208}Pb{sup 82+} ion operation in the LHC, with focus on the alice interaction region, and show that the expected heat load during nominal {sup 208}Pb{sup 82+} operation is 40% above the quench level. This limits the maximum achievable luminosity. Furthermore, we discuss methods of monitoring the losses and possible ways to alleviate their effect.

43 PARTICLE ACCELERATORS↗

Changes in Distal Tibial Microarchitecture During Eight Weeks of U.S. Army Basic Combat Training Differ by Sex and Race

ABSTRACT Basic combat training (BCT) is a physically rigorous period at the beginning of a soldier's career that induces bone formation in the tibia. Race and sex are determinants of bone properties in young adults but their influences on changes in bone microarchitecture during BCT are unknown. The purpose of this work was to determine the influence of sex and race on changes in bone microarchitecture during BCT. Bone microarchitecture was assessed at the distal tibia via high‐resolution peripheral quantitative computed tomography at the beginning and end of 8 weeks of BCT in a multiracial cohort of trainees (552 female, 1053 male; mean ± standard deviation [SD] age = 20.7 ± 3.7 years) of which 25.4% self‐identified as black, 19.5% as race other than black or white (other races combined), and 55.1% as white. We used linear regression models to determine whether changes in bone microarchitecture due to BCT differed by race or sex, after adjusting for age, height, weight, physical activity, and tobacco use. We found that trabecular bone density (Tb.BMD), thickness (Tb.Th), and volume (Tb.BV/TV), as well as cortical BMD (Ct.BMD) and thickness (Ct.Th) increased following BCT in both sexes and across racial groups (+0.32% to +1.87%, all p < 0.01). Compared to males, females had greater increases in Tb.BMD (+1.87% versus +1.40%; p = 0.01) and Tb.Th (+0.87% versus +0.58%; p = 0.02), but smaller increases in Ct.BMD (+0.35% versus +0.61%; p < 0.01). Compared to black trainees, white trainees had greater increases in Tb.Th (+0.82% versus +0.61%; p = 0.03). Other races combined and white trainees had greater increases in Ct.BMD than black trainees (+0.56% and + 0.55% versus +0.32%; both p ≤ 0.01). Changes in distal tibial microarchitecture, consistent with adaptive bone formation, occur in trainees of all races and sexes, with modest differences by sex and race. Published 2023. This article is a U.S. Government work and is in the public domain in the USA. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

Hughes, Julie M.↗

Dose Specification and Quality Assurance of Radiation Therapy Oncology Group Protocol 95-17; a Cooperative Group Study of Iridium-192 Breast Implants as Sole Therapy

Purpose: The Radiation Therapy Oncology Group (RTOG) protocol 95-17 was a Phase I/II trial to evaluate multicatheter brachytherapy as the sole method of adjuvant breast radiotherapy for Stage I/II breast carcinoma after breast-conserving surgery. Low- or high-dose-rate sources were allowed. Dose prescription and treatment evaluation were based on recommendations in the International Commission on Radiation Units and Measurements (ICRU), Report 58 and included the parameters mean central dose (MCD), average peripheral dose, dose homogeneity index (DHI), and the dimensions of the low- and high-dose regions. Methods and Materials: Three levels of quality assurance were implemented: (1) credentialing of institutions was required before entering patients into the study; (2) rapid review of each treatment plan was conducted before treatment; and (3) retrospective review was performed by the Radiological Physics Center in conjunction with the study chairman and RTOG dosimetry staff. Results: Credentialing focused on the accuracy of dose calculation algorithm and compliance with protocol guidelines. Rapid review was designed to identify and correct deviations from the protocol before treatment. The retrospective review involved recalculation of dosimetry parameters and review of dose distributions to evaluate the treatment. Specifying both central and peripheral doses resulted in uniform dose distributions, with a mean dose homogeneity index of 0.83 {+-} 0.06. Conclusions: Vigorous quality assurance resulted in a high-quality study with few deviations; only 4 of 100 patients were judged as representing minor variations from protocol, and no patient was judged as representing major deviation. This study should be considered a model for quality assurance of future trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of Medium-Induced Modifications of Jet Fragmentation in Pb-Pb Collisions at $\sqrt{s_{NN}}=$ 5.02 TeV Using Isolated Photon-Tagged Jets

Measurements of fragmentation functions for jets associated with an isolated photon are presented for the first time in pp and Pb-Pb collisions. The analysis uses data collected with the CMS detector at the CERN LHC at a nucleon-nucleon center-of-mass energy of 5.02 TeV. Fragmentation functions are obtained for jets with pTjet>30 GeV/c in events containing an isolated photon with pTγ>60 GeV/c, using charged tracks with transverse momentum pTtrk>1 GeV/c in a cone around the jet axis. The association with an isolated photon constrains the initial pT and azimuthal angle of the parton whose shower produced the jet. For central Pb-Pb collisions, modifications of the jet fragmentation functions are observed when compared to those measured in pp collisions, while no significant differences are found in the 50% most peripheral collisions. Jets in central Pb-Pb events show an excess (depletion) of low (high) pT particles, with a transition around 3 GeV/c. This measurement shows for the first time the in-medium shower modifications of partons (quark dominated) with well-defined initial kinematics. It constitutes a new well-controlled reference for testing theoretical models of the parton passage through the quark-gluon plasma.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-18C-08: A Validation Study of a Commercially Available Software Package's Absorbed Dose Estimates in a Physical Phantom

Purpose: This study assesses the accuracy of the absorbed dose estimates from CT scans generated by Monte Carlo (MC) simulation using a commercially available radiation dose monitoring software program. Methods: Axial CT studies of an anthropomorphic abdomen phantom with dose bores at a central location and 4 peripheral locations were conducted using a fixed tube current at 120 kV. A 100 mm ion chamber and a 0.6 cc ion chamber calibrated at diagnostic energy levels were used to measure dose in the phantom at each of the 5 dose bore locations. Simulations using the software program's Monte Carlo engine were run using a mathematical model of the anthropomorphic phantom to determine conversion coefficients between the CTDIvol used for the study and the dose at the location of the dose bores. Simulations were conducted using both the software's generic CT beam model and a refined model generated using HVL and bow tie filter profile measurements made on the scanner used for the study. Results: Monte Carlo simulations completed using the generalized beam model differed from the measured conversion factors by an absolute value average of 13.0% and 13.8% for the 100 mm and 0.6 cc ion chamber studies, respectively. The MC simulations using the scanner specific beam model generated conversion coefficients that differed from the CTDIvol to measured dose conversion coefficients by an absolute value average of 7.3% and 7.8% for the 100 mm and 0.6 cc ion chamber cases, respectively. Conclusion: A scanner specific beam model used in MC simulations generates more accurate dose conversion coefficients in an anthropomorphic phantom than those generated with a generalized beam model. Agreement between measured conversion coefficients and simulated values were less than 20% for all positions using the universal beam model.

07 ISOTOPE AND RADIATION SOURCES↗