Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASTIC SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-C-304-03: Experimental Investigation On the Accuracy of Plastic Scintillation Dosimeters in Small Fields

Purpose: To investigate the accuracy of the Exradin W1 (SI) and of an “in-house” plastic scintillation dosimeter (CHUQ PSD) in small radiation fields. Methods: Output factor (OF) measurements with the W1 and CHUQ PSD were performed for field sizes of 0.5 x 0.5, 1 x 1 and 2 x 2 cm{sup 2}. Both detectors were placed parallel to the central axis (CAX) in water. The spectrum discrimination calibration method was performed in each set-up to account for the Cerenkov (CRV) signal created in the fiber. The OFs were compared to the expected field factors in water derived using i) Monte Carlo (MC) simulations of an accurate accelerator model and ii) microLion (PTW) and D1V diode (SI) OFs. MC-derived correction factors were applied to both the microLion and D1V OFs. For the CHUQ PSD the calibration was repeated in water (// CAX), solid water (perpendicular to CAX) and under a shielded configuration. The signal was collected using a spectrometer (wavelength range = 185–1100 nm). Spectral analysis was performed to evaluate potential changes of the spectral distributions under the various calibration set-up configurations. Results: The W1 OFs presented an over-response for the 0.5 x 0.5 cm{sup 2} in the range of 3 – 4.1% relative to the expected field factor. The CHUQ PSD presented an under-response in the range of 1.5 – 2.7%, without accounting for volume averaging. The CRV spectra under the various calibration procedures appeared similar to each other and only minor changes were observed to the respective OFs. Conclusion: The W1 and CHUQ PSD can be used in small fields down to a 1 x 1 cm{sup 2} field size. Discrepancies were encountered between the two detectors for the smallest field size of 0.5 x 0.5 cm{sup 2} with the CHUQ PSD exhibiting a closer agreement to the expected field factor. Funding sources: 1) Alexander S. Onassis Public Benefit Foundation in Greece and 2) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council, Grant number: 432290, RGPIN-2014-06475.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Final State Interaction Strength in Plastic Scintillator by Muon-Neutrino Charged Current Charged Pion Production

Precise knowledge of neutrino-nucleus interactions is increasingly important as neutrino oscillation measurements transition into the systematics-limited era. In addition to modifying the initial interaction, the nuclear medium can scatter and absorb the interaction by-products through final state interactions, changing the types and kinematic distributions of particles seen by the detector. Recent neutrino pion production data from MiniBooNE is inconsistent with the final state interaction strength predicted by models and theoretical calculations, and some models fit best to the MiniBooNE data only after removing final state interactions entirely. This thesis presents a measurement of dσ/dT π and dσ/dθ π for muon-neutrino charged current charged pion production in the MINER A scintillator tracker. MINER A is a neutrino-nucleus scattering experiment installed in the few-GeV NuMI beam line at Fermilab. The analysis is limited to neutrino energies between 1.5-10 GeV. Dependence on invariant hadronic mass W is studied through two versions of the analysis that impose the limits W < 1.4 GeV and W < 1.8 GeV. The lower limit on W increases compatibility with the MiniBooNE pion data. The shapes of the differential cross sections, which depend strongly on the nature of final state interactions, are compared to Monte Carlo and theoretical predictions. It is shown that the measurements presented in this thesis favor models that contain final state interactions. Additionally, a variety of neutrino-nucleus interaction models are shown to successfully reproduce the thesis measurements, while simultaneously failing to describe the shape of the MiniBooNE data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon Detection System Designs for the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE) will be a premier facility for exploring long-standing questions about the boundaries of the standard model. Acting in concert with the liquid argon time projection chambers underpinning the far detector design, the DUNE photon detection system will capture ultraviolet scintillation light in order to provide valuable timing information for event reconstruction. To maximize the active area while maintaining a small photocathode coverage, the experiment will utilize a design based on plastic light guides coated with a wavelength-shifting compound, along with silicon photomultipliers, to collect and record scintillation light from liquid argon. This report presents recent preliminary performance measurements of this baseline design and several alternative designs which promise significant improvements in sensitivity to low-energy interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron annihilation lifetime spectroscopy using fast scintillators and digital electronics

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron lifetime in a material sample under investigation. The positron trapping at vacancies in the material results in an increased positron lifetime. In this work, we have developed and optimized a PALS experimental setup using organic scintillators, fast digitizers, and advanced pulse processing algorithms. We tested three pairs of different organic scintillators: EJ-309 liquid, EJ-276 newly developed plastic, and BC- 418 plastic, and optimized the data processing parameters for each pair separately. Our high-throughput data analysis method is based on single-pulse interpolation and a constant fraction discrimination (CFD) algorithm. The setup based on the BC-418 detector achieved the best time resolution of 198.3 ± 0.8 ps. We used such optimized setup to analyze two single-crystal quartz samples and found lifetimes of 161 ± 4 ps, 343 ± 12 ps and 1.34 ± 0.05 ns, in good agreement with the characteristic time constants of this material. The proposed experimental set up achieves a time resolution comparable to the minimum positron lifetime in quartz, which makes it possible to accurately characterize material vacancies by discriminating between the lifetimes of either the spin singlet or triplet states of positronium. The optimized data processing algorithms are relevant to all the applications where fast timing is important, such as nuclear medicine and radiation imaging

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium and Zinc Sulfide Coated Plastic Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of 6Li/ZnS(Ag)-coated scintillator paddles. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Symetrica.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sci—Sat AM: Stereo — 07: Suitability of a plastic scintillator dosimeter for composite clinical fields delivered using the Cyberknife robotic radiosurgery system

Plastic scintillation dosimeters (PSDs) have favourable characteristics for small and composite field dosimetry in radiosurgery, however, imperfect corrections for the Cerenkov radiation contamination could limit their accuracy for complex deliveries. In this work, we characterize the dose and dose-rate linearity, directional dependence, and compare output factors with other stereotactic detectors for a new commercially available PSD (Exradin W1). We provide some preliminary comparisons of planned and measured dose for composite fields delivered clinically by a Cyberknife radiosurgery system. The W1 detector shows good linearity with dose (<0.5%) and dose rate (<0.8%) relative to the signal obtained using an ion chamber under the same conditions. A maximum difference of 2% was observed depending on the detector's angular orientation. Output factors for all detectors agree within a range of ±3.2% and ±1.5% for the 5 and 7.5 mm collimators, respectively, provided Monte-Carlo corrections for detector effects are applied to diode and ion chambers (without corrections the range is ±5.5% and ±3.1% for these two collimators). For clinical beam deliveries using 5 and 7.5 mm collimators, four of the six patients showed better agreement with planned dose for the PSD detector compared to a micro ion chamber. Two of the six patients investigated, however, showed 5% differences between PSD and planned dose, film measurements and the ratio of PSD and micro ion chamber signal suggest that further investigation is warranted for these plans. The W1 detector is a promising tool for stereotactic plan verification under the challenging dosimetric conditions of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

{eta}-meson production in proton-proton collisions at excess energies of 40 and 72 MeV

The production of {eta} mesons in proton-proton collisions has been studied using the WASA detector at the CELSIUS storage ring at excess energies of Q=40 MeV and Q=72 MeV. The {eta} was detected through its 2{gamma} decay in a near-4{pi} electromagnetic calorimeter, whereas the protons were measured by a combination of straw chambers and plastic scintillator planes in the forward hemisphere. About 6.9x10{sup 4} and 9.3x10{sup 4} events were found at Q=40 MeV and Q=72 MeV, respectively, with background contributions of less than 5%. A simple parametrization of the production cross section in terms of low partial waves was used to evaluate the acceptance corrections. Strong evidence was found for the influence of higher partial waves. The Dalitz plots show the presence of p waves in both the pp and the {eta}{l_brace}pp{r_brace} systems and the angular distributions of the {eta} in the center-of-mass frame suggest the influence of d-wave {eta} mesons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing the ATIC Charge Resolution

The Advanced Thin Ionization Calorimeter (ATIC) experiment measures the energy spectra of elements, from H to Fe, in the energy region from about 100 GeV to tens of TeV. The ATIC instrument was flown twice in long-duration balloon flights around the South Pole; the ATIC-1 test flight during Dec. 2000 - Jan. 2001 and the ATIC-2 science flight during Dec. 2002 - Jan. 2003. Analyses of both datasets have, to date, relied upon the highly segmented Silicon Matrix (SiM) detector to separate the incident cosmic ray from the calorimeter backscatter and to identify the charge. This method has worked well, enabling ATIC to separate protons from helium and to resolve all the major species up through iron. This charge resolution can be significantly improved by restricting the analysis to particle trajectories that pass through two SiM pixels at the cost of using only a fraction of the potential instrument geometry. However, immediately below the SiM is the two layer SI hodoscope (x, y) consisting of Bicron BC-408 plastic scintillator 2 cm wide, 1 cm thick, 88.2 cm long strips viewed by Hamamatsu R5611 photomultiplier tubes on each end of each strip. The primary purpose of the ATIC hodoscopes is to provide a fast trigger, and each hodoscope includes two crossed layers of strips (42 per layer in the case of Sl) providing supplemental particle trajectory information. The hodoscope readout electronics were designed to provide reasonable charge resolution over the dynamic range from protons through iron. This presentation discusses the S 1 hodoscope energy deposit calibrations, examines the charge resolution possible with this detector and investigates combining the S1 and SiM charge measurements to improve the overall ATIC charge resolution while minimizing degradation of the instrument geometry.

Guzik, T. G.↗

Cherenkov-dE/dx-range measurements on cosmic ray iron group nuclei

A balloon experiment which combined a large area plastic detector unit with electronic dE/dx-C data is presented. The correlation of the electronic data with the range data of the plastic detector stack was achieved by rotating plastic detector disks which provided in this way the passive plastic detector with an incorporated time determination. The constant flux of cosmic ray particles with charge Z greater than two was used to gauge the time resolving system. Stopping cosmic ray iron group nuclei in the energy range 400 to 700 MeV/nuc are identified using their electronic scintillator and Cherenkov signals and their etch conelengths and range data. The precise knowledge of the particle's trajectory proposes refined pathlength corrections to the electronic data.

Sermund, G.↗

Fermi Gamma-ray Space Telescope

The Fermi Gamma-ray Space Telescope, a key mission in multiwavelength and multimessenger studies, has been surveying the γ-ray sky from its low-Earth orbit since 2008. Its two scientific instruments, the Gamma-ray Burst Monitor (GBM) and the Large Area Telescope (LAT), cover 8 orders of magnitude in photon energy. The GBM consists of 12 Sodium Iodide detectors and 2 Bismuth Germinate detectors, covering the 10 keV - 40 MeV energy range, arrayed on two sides of the spacecraft so as to view the entire sky that is not occulted by the Earth. The LAT is a pair production telescope based on silicon strip trackers, a Cesium Iodide calorimeter, and a plastic scintillator anticoincidence system. It covers the energy range from about 20 MeV to more than 500 GeV, with a field of view of about 2.4 steradians. Thanks to their huge fields of view, the instruments can observe the entire sky with a cadence of about an hour for GBM and about three hours for LAT. All γ-ray data from Fermi become public immediately, enabling a broad range of multiwavelength and multimessenger research. Over 3000 γ-ray bursts (GRBs), including GRB 170817A associated with a neutron star merger detected in gravitational waves, and 5000 high-energy sources, including the blazar TXS 0506+056 associated with high-energy neutrinos, have been detected by the Fermi instruments. The Fermi Science Support Center provides a wide array of resources to enable scientific use of the data, including background models, source catalogs, analysis software, documentation, and a Help Desk.

gamma rays↗

MICE: The International Muon Ionization Cooling Experiment: Diagnostic Systems

The Muon Ionization Cooling Experiment will make detailed measurements of muon ionization cooling using a new constructed low-energy muon beam at the Rutherford Appleton Laboratory (RAL). The experiment is a single-particle experiment and utilizes many detector techniques from high energy physics experiments. To characterize and monitor the muon beamline, newly developed scintillating fiber profile monitors and scintillator paddle rate monitors are employed. In order to monitor the purity of the beam and tag the arrival time of individual muons, a dual aerogel Cherenkov system is used, and a plastic scintillator time-of-flight system will be used. The phase-space vectors of the muons will be measured by two identical spectrometer systems (one before and one after the cooling apparatus) which employ a fiber tracker system, and electron and muon calorimeters are used to tag outgoing muons. We will discuss the design of the MICE diagnostic systems, the operation, and give the first results from beam measurements in the MICE experimental hall.

43 PARTICLE ACCELERATORS↗

Characterization of a large-area iQID imager for safeguards applications

Environmental sampling and sample analyses by the International Atomic Energy Agency is a key method for verifying declarations in international safeguards agreements. Quantitative Digital Autoradiography for Environmental Samples is a system developed by Pacific Northwest National Laboratory to examine environmental swipe samples (ESS) prior to subsequent, destructive analysis. This approach is passive and noninvasive for imaging beta and gamma emissions, which transmit through the plastic bags containing the ESS. Alpha particle imaging is also possible with different ESS containers. This technology is based on a portable, real-time, event-counting, high spatial resolution system called iQID (ionizing-radiation Quantum Imaging Detector), which is made from commercial, off-the-shelf components. This includes a scintillator in direct contact with a micro-channel plate image intensifier and a lens for imaging the intensified scintillation events onto a CCD/CMOS camera. The QDARES large-area iQID includes a fiber-optic taper coupled to the image intensifier which increases the imaging area to a ~100 cm square with a 105 mm x 105 mm taper. In this study, we describe new characterization results, including spatial resolution, energy response, minimum detectable activity for several isotopes, detector uniformity, and count-rate capability.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Measurements of the muon flux produced by 10.6 GeV electrons in a beam dump

This paper proposes the results of an experiment to assess the muon flux produced by the interaction of a 10.6 GeV electron beam with the Hall-A beam dump at Jefferson Lab (JLab). The goal was to benchmark Monte Carlo simulations that are an essential tool for estimating beam-related backgrounds in beam-dump experiments aimed at searching for rare events, such as the Beam Dump eXperiment (BDX) planned at JLab. Beam-produced muons were measured with a CsI(Tl) crystal sandwiched between a set of segmented plastic scintillators placed at two different distances from the dump: 25.7 m and 28.8 m. At each location the muon flux was sampled at different vertical positions with respect to the beam height. Data have been compared with detailed Monte Carlo simulations using FLUKA for the muon production in the dump and propagation to the detector, and GEANT4 to simulate the detector response. The good agreement between data and simulations, within the uncertainties of the soil composition and density, exhibit the validity of our simulation tools to predict the beam-related muon background in electron beam-dump experiments at ~10 GeV.

47 OTHER INSTRUMENTATION↗

Design and construction of the MicroBooNE Cosmic Ray Tagger system

The MicroBooNE detector utilizes a liquid argon time projection chamber (LArTPC) with an 85 t active mass to study neutrino interactions along the Booster Neutrino Beam (BNB) at Fermilab. Additionally, with a deployment location near ground level, the detector records many cosmic muon tracks in each beam-related detector trigger that can be misidentified as signals of interest. To reduce these cosmogenic backgrounds, we have designed and constructed a TPC-external Cosmic Ray Tagger (CRT). This sub-system was developed by the Laboratory for High Energy Physics (LHEP), Albert Einstein center for fundamental physics, University of Bern. The system utilizes plastic scintillation modules to provide precise time and position information for TPC-traversing particles. Successful matching of TPC tracks and CRT data will allow us to reduce cosmogenic background and better characterize the light collection system and LArTPC data using cosmic muons. Here, we describe the design and installation of the MicroBooNE CRT system and provide an overview of a series of tests done to verify the proper operation of the system and its components during installation, commissioning, and physics data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, assembly and operation of a Cosmic Ray Tagger based on scintillators and SiPMs

The Mu2e experiment at Fermilab aims to search for the SM forbidden μ – → e – conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and a crystal calorimeter, made of two annular disks. Here, in order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5 x 1.5 x 160 cm 3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.

79 ASTRONOMY AND ASTROPHYSICS↗