Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Survival analysis of localized prostate cancer with deep learning

In recent years, data-driven, deep-learning-based models have shown great promise in medical risk prediction. By utilizing the large-scale Electronic Health Record data found in the U.S. Department of Veterans Affairs, the largest integrated healthcare system in the United States, we have developed an automated, personalized risk prediction model to support the clinical decision-making process for localized prostate cancer patients. This method combines the representative power of deep learning and the analytical interpretability of parametric regression models and can implement both time-dependent and static input data. To collect a comprehensive evaluation of model performances, we calculate time-dependent C-statistics C td over 2-, 5-, and 10-year time horizons using either a composite outcome or prostate cancer mortality as the target event. The composite outcome combines the Prostate-Specific Antigen (PSA) test, metastasis, and prostate cancer mortality. Our longitudinal model Recurrent Deep Survival Machine (RDSM) achieved C td 0.85 (0.83), 0.80 (0.83), and 0.76 (0.81), while the cross-sectional model Deep Survival Machine (DSM) attained C td 0.85 (0.82), 0.80 (0.82), and 0.76 (0.79) for the 2-, 5-, and 10-year composite (mortality) outcomes, respectively. In addition to estimating the survival probability, our method can quantify the uncertainty associated with the prediction. The uncertainty scores show a consistent correlation with the prediction accuracy. We find PSA and prostate cancer stage information are the most important indicators in risk prediction. Our work demonstrates the utility of the data-driven machine learning model in prostate cancer risk prediction, which can play a critical role in the clinical decision system.

60 APPLIED LIFE SCIENCES↗

Treatment of Prostate Cancer with CD46-targeted 225 Ac Alpha Particle Radioimmunotherapy

Radiopharmaceutical therapy is changing the standard of care in prostate cancer and other malignancies. We previously reported high CD46 expression in prostate cancer and developed an antibody–drug conjugate and immunoPET agent based on the YS5 antibody, which targets a tumor-selective CD46 epitope. Here, we present the preparation, preclinical efficacy, and toxicity evaluation of [ 225 Ac]DOTA-YS5, a radioimmunotherapy agent based on the YS5 antibody. [ 225 Ac]DOTA-YS5 was developed, and its therapeutic efficiency was tested on cell-derived (22Rv1, DU145), and patient-derived (LTL-545, LTL484) prostate cancer xenograft models. Biodistribution studies were carried out on 22Rv1 tumor xenograft models to confirm the targeting efficacy. Toxicity analysis of the [ 225 Ac]DOTA-YS5 was carried out on nu/nu mice to study short-term (acute) and long-term (chronic) toxicity. Biodistribution study shows that [ 225 Ac]DOTA-YS5 agent delivers high levels of radiation to the tumor tissue (11.64% ± 1.37%ID/g, 28.58% ± 10.88%ID/g, 29.35% ± 7.76%ID/g, and 31.78% ± 5.89%ID/g at 24, 96, 168, and 408 hours, respectively), compared with the healthy organs. [ 225 Ac]DOTA-YS5 suppressed tumor size and prolonged survival in cell line–derived and patient-derived xenograft models. Toxicity analysis revealed that the 0.5 μCi activity levels showed toxicity to the kidneys, likely due to redistribution of daughter isotope 213 Bi. [ 225 Ac]DOTA-YS5 suppressed the growth of cell-derived and patient-derived xenografts, including prostate-specific membrane antigen–positive and prostate-specific membrane antigen–deficient models. Overall, this preclinical study confirms that [ 225 Ac]DOTA-YS5 is a highly effective treatment and suggests feasibility for clinical translation of CD46-targeted radioligand therapy in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of atlas-based auto-segmentation software in prostate cancer patients

The performance and limitations of an atlas-based auto-segmentation software package (ABAS; Elekta Inc.) was evaluated using male pelvic anatomy as the area of interest. Contours from 10 prostate patients were selected to create atlases in ABAS. The contoured regions of interest were created manually to align with published guidelines and included the prostate, bladder, rectum, femoral heads and external patient contour. Twenty-four clinically treated prostate patients were auto-contoured using a randomised selection of two, four, six, eight or ten atlases. The concordance between the manually drawn and computer-generated contours were evaluated statistically using Pearson's product–moment correlation coefficient (r) and clinically in a validated qualitative evaluation. In the latter evaluation, six radiation therapists classified the degree of agreement for each structure using seven clinically appropriate categories. The ABAS software generated clinically acceptable contours for the bladder, rectum, femoral heads and external patient contour. For these structures, ABAS-generated volumes were highly correlated with ‘as treated’ volumes, manually drawn; for four atlases, for example, bladder r = 0.988 (P < 0.001), rectum r = 0.739 (P < 0.001) and left femoral head r = 0.560 (P < 0.001). Poorest results were seen for the prostate (r = 0.401, P < 0.05) (four atlases); however this was attributed to the comparison prostate volume being contoured on magnetic resonance imaging (MRI) rather than computed tomography (CT) data. For all structures, increasing the number of atlases did not consistently improve accuracy. ABAS-generated contours are clinically useful for a range of structures in the male pelvis. Clinically appropriate volumes were created, but editing of some contours was inevitably required. The ideal number of atlases to improve generated automatic contours is yet to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rationale for a 'Male Lumpectomy,' a Prostate Cancer Targeted Approach Using Cryoablation: Results in 21 Patients with at Least 2 Years of Follow-Up

Background. Prostate cancer in men raises many of the same issues that breast cancer does in women. Complications of prostate cancer treatment, including impotence and incontinence, affect the self-image and psyche of a man no less than does the loss of a breast in a woman. We present a pilot study in which 21 patients were treated with a focal cryoablation procedure. Methods. Focal cryoablation was performed using biplane transrectal ultrasound if the tumor was confined to only one prostate lobe. Preoperative PSA values were recorded. Cryoablation was planned to encompass the area of known tumor. PSA values were obtained every 3 months for 2 years and every 6 months thereafter. Potency and continence status was obtained at the same intervals. Routine biopsy was obtained at 1 year. Results. Twenty-one patients had focal cryoablation. Follow-up ranged from 24 to 105 months with a mean of 50 months. Twenty of 21 (95%) patients have stable PSA values with no evidence for cancer, despite 10 patients being at medium to high risk for recurrence. All patients biopsied (n = 19) were negative for tumor. Potency was maintained in 17 of 21 patients (80%). No other complications, including incontinence or fistula formation, were noted. Conclusion. These preliminary results indicate a 'male lumpectomy,' in which the prostate tumor region itself is destroyed, appears to preserve potency in a majority of patients and limits other complications, without compromising cancer control. If these results are confirmed by further studies and long-term follow-up, this treatment approach could have a profound effect on prostate cancer management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anti-Prostate Cancer Activity of 8-Hydroxyquinoline-2-Carboxaldehyde–Thiosemicarbazide Copper Complexes by Fluorescent Microscopic Imaging

Copper 8-hydroxyquinoline-2-carboxaldehyde–thiosemicarbazide (CuHQTS) and copper 8-hydroxyquinoline-2-carboxaldehyde–4,4-dimethyl-3-thiosemicarbazide (CuHQDMTS) are two copper thiosemicarbazone complexes with potent anticancer activity on cisplatin-resistant neuroblastoma cells. This study aimed to evaluate anti-prostate cancer activity of these two copper complexes in vitro. Both CuHQTS and CuHQDMTS inhibited proliferation of prostate cancer cells and showed cytotoxicity on prostate cancer cells carrying green fluorescent protein (GFP) by fluorescent microscopic imaging. The findings of this study demonstrated anti-prostate cancer activity of CuHQTS and CuHQDMTS and suggested that GFP-carrying prostate cancer cells might be used for testing anticancer activity of copper complexes by fluorescent microscopic imaging.

60 APPLIED LIFE SCIENCES↗

A combination of desmopressin and docetaxel inhibit cell proliferation and invasion mediated by urokinase-type plasminogen activator (uPA) in human prostate cancer cells

Background: This study was designed to assess the effectiveness of a combination treatment using both desmopressin and docetaxel in prostate cancer treatment. Desmopressin is a well-known synthetic analogue of the antidiuretic hormone vasopressin. It has recently been demonstrated to inhibit tumor progression and metastasis in in vivo models. Docetaxel is widely used for the treatment of castration resistant prostate cancer (CRPC) patients. However, durable responses have been uncommon to date. In this study, we investigated the anti-tumor effect of desmopressin in combination with docetaxel in vitro and in vivo. Methods: Two prostate cancer cells (PC3, LNCaP) were treated with different concentrations of desmopressin alone, docetaxel alone, and a combination of desmopressin and docetaxel. Cell proliferation was determined by MTS assay. The anti-invasive and anti-migration potential of desmopressin and in combination with docetaxel were examined by wound healing assay, migration chamber assay, and matrigel invasion assay. Results: The combination of desmopressin and docetaxel resulted in a significant inhibition of PC3 and LNCaP cell proliferation (p < 0.01). Additionally, cell migration and invasion were also inhibited by the combination when compared to that of either treatment alone in PC3 cells (p < 0.01). The anti-tumor effect of this combination treatment was associated with down-regulation of both urokinase-type plasminogen activator (uPA) and matrix metalloproteinase (MMP-2 and MMP-9) in PC3 cells. Conclusions: We are the first to elucidate the anti-tumor and anti-metastatic potential of desmopressin in combination with docetaxel in a prostate cancer model via the uPA-MMP pathway. Our finding could potentially contribute to the therapeutic profile of desmopressin and enhance the efficacy of docetaxel based treatment for CRPC. - Highlights: • Desmopressin inhibits cell proliferation in prostate cancer cells. • The expression of cyclin A and CDK2 were reduced in the cells treated with desmopressin and docetaxel. • uPA-MMP pathway mediates the desmopressin-induced migration and invasion of PC3 cells. • Desmopressin in combination with docetaxel inhibits PC-3 cell growth in a xenograft model.

60 APPLIED LIFE SCIENCES↗

An Update of the Phase III Trial Comparing Whole Pelvic to Prostate Only Radiotherapy and Neoadjuvant to Adjuvant Total Androgen Suppression: Updated Analysis of RTOG 94-13, With Emphasis on Unexpected Hormone/Radiation Interactions

Purpose: This trial was designed to test the hypothesis that total androgen suppression and whole pelvic radiotherapy (WPRT) followed by a prostate boost improves progression-free survival (PFS) by {>=}10% compared with total androgen suppression and prostate only RT (PORT). This trial was also designed to test the hypothesis that neoadjuvant hormonal therapy (NHT) followed by concurrent total androgen suppression and RT improves PFS compared with RT followed by adjuvant hormonal therapy (AHT) by {>=}10%. Methods and Materials: Patients eligible for the study included those with clinically localized adenocarcinoma of the prostate and an elevated prostate-specific antigen level of <100 ng/mL. Patients were stratified by T stage, prostate-specific antigen level, and Gleason score and were required to have an estimated risk of lymph node involvement of >15%. Results: The difference in overall survival for the four arms was statistically significant (p = 0.027). However, no statistically significant differences were found in PFS or overall survival between NHT vs. AHT and WPRT compared with PORT. A trend towards a difference was found in PFS (p = 0.065) in favor of the WPRT + NHT arm compared with the PORT + NHT and WPRT + AHT arms. Conclusions: Unexpected interactions appear to exist between the timing of hormonal therapy and radiation field size for this patient population. Four Phase III trials have demonstrated better outcomes when NHT was combined with RT compared with RT alone. The Radiation Therapy Oncology Group 9413 trial results have demonstrated that when NHT is used in conjunction with RT, WPRT yields a better PFS than does PORT. It also showed that when NHT + WPRT results in better overall survival than does WPRT + short-term AHT. Additional studies are warranted to determine whether the failure to demonstrate an advantage for NHT + WPRT compared with PORT + AHT is chance or, more likely, reflects a previously unrecognized biologic phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic Boundaries of the Clinical Target Volume (Prostate Bed) After Radical Prostatectomy

Purpose: We sought to derive and validate an interdisciplinary consensus definition for the anatomic boundaries of the postoperative clinical target volume (CTV, prostate bed). Methods and Materials: Thirty one patients who had planned for radiotherapy after radical prostatectomy were enrolled and underwent computed tomography and magnetic resonance imaging (MRI) simulation prior to radiotherapy. Through an iterative process of consultation and discussion, an interdisciplinary consensus definition was derived based on a review of published data, patterns of local failure, surgical practice, and radiologic anatomy. In validation, we analyzed the distribution of surgical clips in reference to the consensus CTV and measured spatial uncertainties in delineating the CTV and vesicourethral anastomosis. Clinical radiotherapy plans were retrospectively evaluated against the consensus CTV (prostate bed). Results: Anatomic boundaries of the consensus CTV (prostate bed) are described. Surgical clips (n = 339) were well distributed throughout the CTV. The vesicourethral anastomosis was accurately localized using central sagittal computed tomography reconstruction, with a mean {+-} standard deviation uncertainty of 1.8 {+-} 2.5 mm. Delineation uncertainties were small for both MRI and computed tomography (mean reproducibility, 0-3.8 mm; standard deviation, 1.0-2.3); they were most pronounced in the anteroposterior and superoinferior dimensions and at the superior/posterior-most aspect of the CTV. Retrospectively, the mean {+-} standard deviation CTV (prostate bed) percentage of volume receiving 100% of prescribed dose was only 77% {+-} 26%. Conclusions: We propose anatomic boundaries for the CTV (prostate bed) and present evidence supporting its validity. In the absence of gross recurrence, the role of MRI in delineating the CTV remains to be confirmed. The CTV is larger than historically practiced at our institution and should be encompassed by a microscopic tumoricidal dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Prostate Cancer Using Kilovoltage Cone-Beam Computed Tomography: First Clinical Results

Purpose: To evaluate the first clinical results of an off-line adaptive radiotherapy (ART) protocol for prostate cancer using kilovoltage cone-beam computed tomography (CBCT) in combination with a diet and mild laxatives. Methods and Materials: Twenty-three patients began treatment with a planning target volume (PTV) margin of 10 mm. The CBCT scans acquired during the first six fractions were used to generate an average prostate clinical target volume (AV-CTV), and average rectum (AV-Rect). Using these structures, a new treatment plan was generated with a 7-mm PTV margin. Weekly CBCT scans were used to monitor the CTV coverage. A diet and mild laxatives were introduced to improve image quality and reduce prostate motion. Results: Twenty patients were treated with conform ART protocol. For these patients, 91% of the CBCT scans could be used to calculate the AV-CTV and AV-Rect. In 96% of the follow-up CBCT scans, the CTV was located within the average PTV. In the remaining 4%, the prostate extended the PTV by a maximum of 1 mm. Systematic and random errors for organ motion were reduced by a factor of two compared with historical data without diet and laxatives. An average PTV reduction of 29% was achieved. The volume of the AV-Rect that received >65 Gy was reduced by 19%. The mean dose to the anal wall was reduced on average by 4.8 Gy. Conclusions: We safely reduced the high-dose region by 29%. The reduction in irradiated volume led to a significant reduction in the dose to the rectum. The diet and laxatives improved the image quality and tended to reduce prostate motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salvage Hypofractionated Radiotherapy for Biochemically Recurrent Prostate Cancer After Radical Prostatectomy

Purpose: To evaluate whether hypofractionation is well tolerated and to preliminarily assess biochemical control of this regimen in a postprostatectomy, salvage setting. Methods and Materials: A retrospective analysis was performed in 50 patients treated between May 2003 and December 2005 with hypofractionated radiotherapy for biochemical recurrence after radical prostatectomy. Radiotherapy was prescribed to the prostatic fossa to 65-70 Gy in 26-28 fractions of 2.5 Gy each, using intensity-modulated radiotherapy with daily image localization. Toxicities were scored using a modified Radiation Therapy Oncology Group scale and the Fox Chase modification of Late Effects Normal Tissue scale. The median follow-up was 18.9 months (range, 5.3-35.9). Results: No Grade 3 or greater acute or late toxicities were observed. Grade 2 toxicities included four acute genitourinary, one acute gastrointestinal, two late genitourinary, and two late gastrointestinal toxicities. Of the 50 patients, 39 demonstrated a continuous biochemical response after salvage therapy, 3 had an initial response before prostate-specific antigen failure, and 7 had prostate-specific antigen progression, 1 of whom died of progressive metastatic disease. Finally, 1 patient discontinued therapy because of the diagnosis of a metachronous pancreatic cancer and died without additional prostate cancer follow-up. All remaining patients were alive at the last follow-up visit. A lower presalvage prostate-specific antigen level was the only significant prognostic factor for improved biochemical control. The estimated actuarial biochemical control rate at 2 years was 72.9%. Conclusions: The toxicity and early biochemical response rates were consistent with expectations from conventional fractionation. Additional follow-up is required to better document the biochemical control, but these results suggest that hypofractionation is a well-tolerated approach for salvage radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of the M. D. Anderson Randomized Dose-Escalation Trial for Prostate Cancer

Purpose: To report the long-term results of a randomized radiotherapy dose escalation trial for prostate cancer. Methods and Materials: From 1993 to 1998, a total of 301 patients with stage T1b to T3 prostate cancer were accrued to a randomized external beam dose escalation trial using 70 Gy versus 78 Gy. The median follow-up is now 8.7 years. Kaplan-Meier analysis was used to compute rates of prostate-specific antigen (PSA) failure (nadir + 2), clinical failure, distant metastasis, disease-specific, and overall survival as well as complication rates at 8 years post-treatment. Results: For all patients, freedom from biochemical or clinical failure (FFF) was superior for the 78-Gy arm, 78%, as compared with 59% for the 70-Gy arm (p = 0.004, and an even greater benefit was seen in patients with initial PSA >10 ng/ml (78% vs. 39%, p = 0.001). The clinical failure rate was significantly reduced in the 78-Gy arm as well (7% vs. 15%, p = 0.014). Twice as many patients either died of prostate cancer or are currently alive with cancer in the 70-Gy arm. Gastrointestinal toxicity of grade 2 or greater occurred twice as often in the high dose patients (26% vs. 13%), although genitourinary toxicity of grade 2 or greater was less (13% vs. 8%) and not statistically significantly different. Dose-volume histogram analysis showed that the complication rate could be significantly decreased by reducing the amount of treated rectum. Conclusions: Modest escalation in radiotherapy dose improved freedom from biochemical and clinical progression with the largest benefit in prostate cancer patients with PSA >10 ng/ml.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Newer Imaging Modalities to Assist With Target Localization in the Radiation Treatment of Prostate Cancer and Possible Lymph Node Metastases

Precise localization of prostate cancer and the drainage lymph nodes is mandatory to define an accurate clinical target volume for conformal radiotherapy. Better target definition and delineation on a daily basis is surely important in quality assurance for fractionated radiation therapy. This article reviews the evidence for major emerging techniques that show promise in better identifying the clinical target volume. Partial prostate boost by brachytherapy, intensity-modulated radiation therapy, or protons has become possible not only with standard imaging techniques but also with the availability of metabolic images obtained by magnetic resonance spectroscopy. Even though fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography has not been found to be useful, novel radiolabeled tracers may eventually prove of value in the diagnosis and treatment planning of prostate cancer. For the metastatic lymph nodes, lymphotropic nanoparticle-enhanced magnetic resonance imaging using ultra-small superparamagnetic iron oxide particles has greater accuracy as compared with conventional techniques and has been instrumental in delineating the lymphatic drainage of the prostate gland. These novel investigational techniques could further help in optimizing conformal radiotherapy for patients with prostate cancer. The concepts of biologic target volume, real target volume, and multidimensional conformal radiotherapy are being explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Target Margin Calculations for Prostate Radiotherapy Based on Intrafraction and Interfraction Motion Using Four Localization Methods

Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the four daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strategy for Online Correction of Rotational Organ Motion for Intensity-Modulated Radiotherapy of Prostate Cancer

Purpose: To develop and evaluate a correction strategy for prostate rotation using gantry and collimator angle adjustments. Methods and Materials: Gantry and collimator angle adjustments were used to correct for prostate rotation without rotating the table. A formula to partially correct for left-right (LR) rotations was derived through geometric analysis of rotation-induced clinical target volume (CTV) beam's-eye-view shape changes. For 10 prostate patients, intensity-modulated radiotherapy (IMRT) plans with different margins were created. Simulating CTV LR rotation and correcting each beam by a collimator rotation, the corrected CTV dose was compared with the original and uncorrected dose. Effects of residual geometric uncertainties were assessed using a Monte Carlo technique. A large number of treatments representative for prostate patients were simulated. Dose probability histograms of the minimum CTV dose (D{sub min}) were derived, with and without online correction, resulting in a more realistic margin estimate. Results: Dosimetric analysis of all IMRT plans showed that, with rotational correction and a 2-mm margin, D{sub min} was constant to within 3% for LR rotations up to {+-}15{sup o}. The Monte Carlo dose probability histograms showed that, with correction, a margin of 4 mm ensured that 90% of patients received a D{sub min} {>=}95% of the prescribed dose. Without correction a margin of 6 mm was required. Conclusions: We developed and tested a practical method for (online) correction of prostate rotation, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Gastrointestinal Morbidity After Three-Dimensional Conformal Radiation Therapy for Prostate Cancer Fades With Time in Contrast to Genitourinary Morbidity

Purpose: To investigate the incidence, time course, and relation to irradiated volumes of late morbidity after three-dimensional conformal radiation therapy (RT) for prostate cancer. Methods and Materials: From January 2000 to December 2001, a total of 247 patients with prostate cancer received a target dose of 70 Gy using conformal RT. Forty-eight patients (20%) received irradiation to the prostate only (Group P), 154 patients (62%) received irradiation to the prostate and seminal vesicles (Group PSV), and 45 patients (18%) received modified pelvic fields (Group MPF). Androgen deprivation was given to 86% of patients. Median follow-up was 62 months. Late gastrointestinal (GI) and genitourinary (GU) morbidity were recorded according to the Radiation Therapy Oncology Group scoring system. Results: We observed 9%, 7%, and 25% Grade 2 or higher GI morbidity and 36%, 30%, and 21% Grade 2 or higher GU morbidity in Groups P, PSV, and MPF, respectively. In multivariate analyses, age and treatment group were independent predictors for the incidence of late Grade 2 or higher GI morbidity, whereas age and urinary symptoms before treatment were independent predictors for late Grade 2 or higher GU morbidity. Acute side effects predicted for late effects. The rectum dose-volume histogram parameters correlated with the incidence of late Grade 2 or higher GI morbidity, especially the fractional volume receiving more than 40-43 Gy. At 5 years of follow-up, the rate of Grade 2 late GI morbidity was only 1.4%, and Grade 2 or higher GU morbidity was 10.6%. Conclusions: The data presented here show that late GI morbidity after prostate RT is low and subsides with time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Need to Compensate for Edema-Induced Dose Reductions in Preplanned {sup 131}Cs Prostate Brachytherapy

Purpose: Surgical trauma-induced edema and its protracted resolution can lead to significant dose reductions in preplanned {sup 131}Cs prostate brachytherapy. The purpose of this work was to examine whether these dose reductions should be actively compensated for and to estimate the magnitude of the additional irradiation needed for dose compensation. Methods and Materials: The quantitative edema resolution characteristics observed by Waterman et al. were used to examine the physical and radiobiologic effects of prostate edema in preplanned {sup 131}Cs implants. The need for dose compensation was assessed using the dose responses observed in {sup 125}I and {sup 103}Pd prostate implants. The biologically effective dose, calculated with full consideration of edema evolution, was used to estimate the additional irradiation needed for dose compensation. Results: We found that the edema-induced dose reduction in preplanned {sup 131}Cs implants could easily exceed 10% of the prescription dose for implants with moderate or large edema. These dose reductions could lead to a >10% reduction in the biochemical recurrence-free survival for individual patients if the effect of edema was ignored. For a prescribed dose of 120 Gy, the number of 2-Gy external beam fractions needed to compensate for a 5%, 10%, 15%, 20%, and 25% edema-induced dose reduction would be one, four, six, seven, and nine, respectively, for prostate cancer with a median potential doubling time of 42 days. The required additional irradiation increased for fast-growing tumors and/or those less efficient in sublethal damage repair. Conclusion: Compensation of edema-induced dose reductions in preplanned {sup 131}Cs prostate brachytherapy should be actively considered for those implants with moderate or large edema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is the Use of a Surrogate Urethra an Option in Prostate High-Dose-Rate Brachytherapy?

Purpose: To investigate the accuracy and the dosimetric consequences of substituting a surrogate urethra assumed to be at the geometric center of the prostate, in place of the true urethra when using high-dose-rate (HDR) brachytherapy for the treatment of prostate cancer. Methods and Materials: One hundred prostate cancer patients treated with HDR brachytherapy constituted the study group. A pre-plan was made with the urethra visualized. The true urethra was defined, and a surrogate urethra was placed at the geometric center of the prostate. The distance between the two urethras was measured. The deviation was evaluated at the base, middle, and apex. To evaluate the dosimetric consequences for the true urethra when using a surrogate urethra, two different dose plans were made: one based on the true urethra and one based on the surrogate urethra. The dose-volume histograms for the true urethra were analyzed. Results: The deviation between the true urethra and the surrogate urethra was greatest at the base of the prostate. A statistically significant difference was seen between the dosimetric parameters for the true and the surrogate urethra when the dose plan was made using the surrogate urethra. In this situation the dose to the true urethra was increased above our defined maximum tolerance limit. Conclusions: When using dose plans made according to a surrogate urethra the dose to the true urethra might be too high to be acceptable. If the true urethra is not visualized, severe damage could easily develop in a significant number of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination External Beam Radiation and Brachytherapy Boost With Androgen Suppression for Treatment of Intermediate-Risk Prostate Cancer: An Initial Report of CALGB 99809

Purpose: Transperineal prostate brachytherapy (TPPB) can be used with external beam radiation therapy (EBRT) to provide a high-dose conformal boost to the prostate. The results of a multicenter Phase II trial assessing safety of combination of EBRT and TPPB boost with androgen suppression (AST) in treatment of intermediate-risk prostate cancer are present here. Materials and Methods: Patients had intermediate-risk prostate cancer. Six months of AST was administered. EBRT to the prostate and seminal vesicles was administered to 45Gy followed by TPPB using either {sup 125}I or {sup 103}Pd to deliver an additional 100Gy or 90Gy. Toxicity was graded using the National Cancer Institute CTC version 2 and the Radiation Therapy Oncology Group late radiation morbidity scoring systems. Results: Sixty-three patients were enrolled. Median follow-up was 38 months. Side effects of AST including sexual dysfunction and vasomotor symptoms were commonly observed. Apart from erectile dysfunction, short-term Grade 2 and 3 toxicity was noted in 21% and 7%, primarily genitourinary related. Long-term Grade 2 and 3 toxicities were noted in 13% and 3%. Two patients had Grade 3 dysuria that resolved with longer follow-up. The most common Grade 2 long-term toxicity was urinary frequency (5%). No biochemical or clinical evidence of progression was noted for the entire cohort. Conclusions: In a cooperative group setting, combination EBRT and TPPB boost with 6 months of AST was generally well tolerated with expected genitourinary and gastrointestinal toxicities. Further follow-up will be required to fully assess long-term toxicity and cancer control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗