Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Explaining the Asymmetric Line Profile in Cepheus X-4 with Spectral Variation Across Pulse Phase

The high mass X-ray binary Cepheus X-4, during its 2014 outburst, showed evidence for an asymmetric cyclotron line in its hard X-ray spectrum. The 2014 spectrum provides one of the clearest cases of an asymmetric line profile among all studied sources with Cyclotron Resonance Scattering Features (CRSF). We present a phase-resolved analysis of NuSTAR and Suzaku data taken at the peak and during the decline phases of this outburst. We find that the pulse-phased resolved spectra are well-fit by a single, symmetric cyclotron feature. The fit parameters vary strongly with pulse phase: most notably the central energy and depth of the cyclotron feature, the slope of the power-law component, and the absorbing column density. We synthesise a ‘phase averaged’ spectrum using the best-fitting parameters for these individual pulse phases, and find that this combined model spectrum has a similar asymmetry in the cyclotron features as discovered in phase-averaged data. We conclude that the pulse phase resolved analysis with simple symmetric line profiles when combined can explain the asymmetry detected in the phase-averaged data.

Bhargave, Yash↗

Evaluation of 2-μm Pulsed Integrated Path Differential Absorption Lidar for Carbon Dioxide Measurement—Technology Developments, Measurements, and Path to Space

The societal benefits of understanding climate change through the identification of global carbon dioxide sources and sinks led to the recommendation for NASA's Active Sensing of Carbon Dioxide Emissions over Nights, Days, and Seasons space-based mission for global carbon dioxide measurements. For more than 15 years, the NASA Langley Research Center has developed several carbon dioxide active remote sensors using the differential absorption lidar technique operating at 2-μm wavelength. Recently, an airborne double-pulsed integrated path differential absorption lidar was developed, tested, and validated for atmospheric carbon dioxide measurement. Results indicated 1.02% column carbon dioxide measurement uncertainty and 0.28% bias over the ocean. Currently, this technology is progressing toward triple-pulse operation targeting both atmospheric carbon dioxide and water vapor-the dominant interfering molecule on carbon dioxide remote sensing. Measurements from the double-pulse lidar and the advancement of the triple-pulse lidar development are presented. In addition, measurement simulations with a space-based IPDA lidar, incorporating new technologies, are also presented to assess feasibility of carbon dioxide measurements from space.

Singh, Upendra N.↗

Impulse Measurements of Electric Solid Propellant in an Electrothermal Ablation-Fed Pulsed Plasma Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled and extinguished) through the application and removal of an electric current. These propellants are also being considered for use in the ablative pulsed plasma thruster. In this paper, the performance of an electric solid propellant operating in an electrothermal ablation-fed pulsed plasma thruster was investigated using an inverted pendulum micro-Newton thrust stand. The impulse bit and specific impulse of the device using the electric solid propellant were measured for short-duration test runs of 100 pulses and longer-duration runs to end-of-life, at energy levels of 5, 10, 15 and 20 J. Also, the device was operated using the current state-of-the-art ablation-fed pulsed plasma thruster propellant, polytetrafluoroethylene or PTFE. Impulse bit measurements for PTFE indicate 100±20 μN-s at an initial energy level of 5 J, which increases linearly by ~30 μN-s/J with increased initial energy. Measurements of the impulse bit for the electric solid propellant are on average lower than PTFE by 10% or less. Specific impulse for when operating on PTFE is calculated to be about 450 s compared to 225 s for the electric solid propellant. The 50% reduction in specific impulse is due to increased mass ablated during operation with the electric solid propellant relative to PTFE.

Glascock, Matthew S.↗

Laboratory characterization of silicon avalanche photodiodes (APD) for pulse position modulation (PPM) detection

Two commercially available large area silicon avalanche photodiodes (APD) were characterized in the laboratory. Specifically, the response of the APD’s to a sequence of 8-bit pulse position modulated (256-PPM) laser pulses, with and without background noise, was recorded and stored for post analysis. Empirical probability distribution functions (pdf) were constructed from the signal and noise slot data and compared to pdf’s predicted by an analytical model based on Webb/Gaussian statistics. The limited pulse sequence was also used to generate bit-error rate (BER) versus signal photons per pulse values, albeit with large error bars. These BER measurements were also compared to results predicted using the Gaussian and Webb/Gaussian models for APD channel statistics. While the measurements qualitatively reflect features predicted by theory, significant quantitative deviations are displayed between the measurements and theory. The source of these discrepancies is not currently well understood, but it is surmised that inaccurate knowledge of detector parameters such as gain and noise equivalent temperature models may explain the discrepancies.

Biswas, A.↗

Estimation of Timing Performance with Pulsed Laser Links for Small Satellite PNT

Satellite constellations are growing in size and in utility for applications as diverse as providing reliable, low-latency internet service to rural areas orEarth science missions.This expansion of satellite constellations brings attention to the need for responsive and reliable satellite communication.Current research in the PrecisionSpace Systems Laboratory at the University of Florida focuses on using pulsed laser communications as the method of relaying time signals instead of the radio frequency (RF)signals.The upcoming CLICK (CubeSat Laser Infrared CrosslinK) missions (Massachusetts Institute of Technology, University of Florida, NASA Ames Research Center) will demonstrate a spacecraft-to-spacecraft laser communication link and time-transfer.For pre-flight technology assessment of missions such as CLICK, a simulation of a spacecraft constellation in Earth orbit has been created to estimate clock synchronization and precision orbit determination based on measured instrumentation performance.We have developed a novel MATLAB-based numerical simulator to model spacecraft-to-spacecraft laser time-transfer and estimate the offset between the spacecraft clocks over time.This simulation includes timing errors associated with laser pulse generation and detection, as well as non-Gaussian clock drift models.The two on-board clocks modeled are a cesium-based Chip-Scale Atomic Clock (CSAC) and a rubidium-based Miniature Atomic Clock (MAC), both produced by Microchip.An example case of two spacecraft in a circular, low-Earth orbit receiving GPS position, GPS timing, and laser pulse time-of-flight measurements is simulated.The positions and velocities of the two spacecraft at a reference epoch and the constant clock model coefficients are estimated.Polynomial models of different orders were used as clock models. The effect of clock model order on the root-mean-square (RMS) of the clock error is apparent in the case using GPS and lasing measurements, showing that the clock model improves with increasing clock model order. Results compare the estimated clock model of a mission operation that only uses GPS measurements and a mission operation that uses both GPS and laser pulse time-of-flight measurements between spacecraft referenced to their on-board CSACs or on-board MACs. Including lasing measurements reduces the RMS clock model error by approximately 80% of the RMS of the cases with only GPS measurements.This simulation tool can be used to optimize the lasing operations schedule based on mission timing performance objectives. During this presentation, I will discuss the details of the simulation and clock model estimation, as well as discuss the results.I will compare the results of incorporating lasing timing measurements to using only GPS measurements and the outcomes of using different orders of polynomials.

Timing Performance↗

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color↗

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-fiber, discrete arbitrary picket-pulse shaping

Here, a novel all-fiber, hybrid pulse-shaping system based on the temporal stacking of discrete optical picket pulses combined with continuously shaped optical pulses provides 100-ps resolution with the high dynamic range and flexibility required for laser fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning of a modulated pulse-power magnetron sputtering system for depositing niobium thin films

A modulated pulse-power magnetron sputtering system (MPPMS) was commissioned and used to deposit niobium on copper. MPPMS utilizes a modulated pulse train with high peak-to-average energy ratios, thereby increasing the energy density leading to the production of the energetic ions. The MPPMS modulator was designed and constructed based on large voltage/current IGBT modules, which can be externally modulated, produce bi-polar waveforms, and are readily available. A high voltage power supply provides moderate current to the IGBT module to create the precise pulse structure. The MPPMS system was used to deposit ~1 mm thick, niobium film on a copper substrate held at ~77 K to minimize Nb atom surface diffusion and maximize intrinsic film energy. Finally, the Nb film had an average grain size of ~8 nm.

42 ENGINEERING↗

Suppression and enhancement of electromagnetic pulses from laser–target interactions by strong magnetic fields

Laser–target interactions generate intense electromagnetic pulses (EMPs) that can interfere with measurements and damage equipment. In this paper we show that applying a magnetic field to nanosecond pulse laser–target interactions decreases the magnitude of EMPs. We demonstrate this effect in two experiments with different geometries (spherical versus planar), laser intensities ( ∼10 13 versus ∼10 15 W/cm 2 ) and applied field strength (12 versus 0.1 T) that both observed suppression of EMPs in approximately the 1 GHz band (by factors of 0.65× and 0.32×, respectively). We then observe the opposite effect at high intensities with a picosecond pulse: for planar experiments with laser intensities of approximately 10 19 W/cm 2 and magnetic fields of 6–10 T, the magnitude of EMPs is increased by a factor of 1.75×. These results provide a benchmark for models of EMP generation, but suggest that magnetic fields are not a viable solution for mitigating EMPs in the high-intensity laser facilities where they are most damaging.

electromagnetic pulse↗

Structural and Electrocatalytic Studies of Pulsed Laser Deposited Epitaxial RuO 2 Thin Films

Two sets of high-quality epitaxial ruthenium oxide (RuO 2 ) thin films with different thicknesses were synthesized in situ on cost-competitive sapphire substrates by using a pulsed laser deposition technique. The first set of films, with a thickness of 40 nm and a sheet resistance of 15.7 Ω/□, was prepared using 2100 laser pulses, while the second set of films, with a thickness of 87 nm and a sheet resistance of 6.7 Ω/□, was prepared using 4800 laser pulses. All other deposition parameters were kept the same. The post-deposition structural and morphological measurements showed that both sets of films grew at the same growth rate, had the same crystallinity, similar grain boundary density, and slightly different surface roughness. The thicker RuO 2 films achieved an overpotential of 280 mV for the oxygen evolution reaction at a current density of 100 μA/cm 2 , comparable to or exceeding the performance of films grown on more expensive substrates. Comparatively, the thinner RuO 2 films, which have a significantly higher charge transfer resistance (250 Ω versus 100 Ω for thick films), display a higher overpotential of 320 mV. These results indicate that the lower electrical resistance of thicker films promotes charge transfer through the film body, leading to superior electrocatalytic properties.

charge-transfer↗

Predicting Pulsed-Laser Deposition SrTiO 3 Homoepitaxy Growth Dynamics Using High-Speed Reflection High-Energy Electron Diffraction

Pulsed-laser deposition (PLD) is a powerful technique for growing complex oxides with controlled stoichiometry. To understand growth dynamics therein, it is common to leverage in situ spectroscopies, such as reflection high-energy electron diffraction (RHEED), to monitor surface crystallinity. Most commercial systems rely on video-rate cameras operating at 60-120 Hz that lack sufficient temporal resolution to capture growth dynamics at practical deposition frequencies. Here, a high-speed platform to record in situ dynamics via RHEED at >500 Hz is implemented. An open-source analysis package is designed to fit diffraction spots to 2D Gaussians, allowing single-pulse surface reconstruction kinetics extraction. Using homoepitaxially deposited (001)-oriented SrTiO 3 as a model system, we demonstrate how high-speed RHEED can provide real-time insight into growth processes obscured by slower acquisition systems. By fitting the single-pulse intensity to a set of exponential functions, we observe changes in the characteristic decay time and mechanism correlated to the substrate step width and surface termination. We observe distinct surface effects, with diffraction intensity decaying on lower-energy TiO 2 -terminated surfaces and stabilizing on SrO- or mixed-terminated surfaces. Similarly, using an exponential model, the extracted characteristic time of adatom deposition decreases with increased density of bonding sites associated with mixed termination and narrower step widths. Ultimately, this work shows how increasing RHEED temporal resolution can uncover new insights into growth processes, with practical implications for the design and control of PLD processes. This experimental platform provides new capabilities to enable data-driven machine learning analysis and autonomous control systems to enhance the complexity and fecundity of PLD.

(SrO)↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulse Compression with Very Low Sidelobes in an Airborne Rain Mapping Rada

The pulse compression system for an airborne rain mapping rada is described. This system uses time domain weighting of the transmit pulse and is able to achive a pulse compression sidelobe level of -55 dB. This is significantly lower than any values previously reported in the open literature.

Pulse Compression↗

Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

angular dependency↗

On-Orbit Performance of the TES Pulse Tube Cryocooler System and the Instrument - Six Years in Space

The Tropospheric Emission Spectrometer (TES) instrument pulse tube cryocoolers began operation 36 days after launch of the NASA Earth Observing System (EOS) Aura spacecraft on July 15, 2004. TES is designed with four infrared Mercury Cadmium Telluride focal plane arrays in two separate housings cooled by a pair of Northrup Grumman Aerospace Systems (NGAS) single-stage pulse tube cryocoolers. The instrument also makes use of a two-stage passive cooler to cool the optical bench. The instrument is a high-resolution infrared imaging Fourier transform spectrometer with 3.3-15.4 micron spectral coverage. After four weeks of outgassing, the instrument optical bench and focal planes were cooled to their operating temperatures to begin science operations. During the early months of the mission, ice contamination of the cryogenic surfaces including the focal planes led to increased cryocooler loads and the need for periodic decontamination cycles. After a highly successful 5 years of continuous in-space operations, TES was granted a 2 year extension. This paper reports on the TES cryogenic system performance including the two-stage passive cooler. After a brief overview of the cryogenic design, the paper presents detailed data on the highly successful space operation of the pulse tube cryocoolers and instrument thermal design over the past six years since the original turn-on in 2004. The data shows the cryogenic contamination decreased substantially to where decontamination cycles are now performed every six months. The cooler stroke required for constant-temperature operation has not increased indicating near-constant cooler efficiency and the instrument's thermal design has also provided a nearly constant heat rejection sink. At this time TES continues to operate in space providing important Earth science data.

cryocoolercraft↗

James Webb Space Telescope Mid Infra-Red Instrument Pulse-Tube Cryocooler Electronics

The latest generation of long life, space pulse-tube cryocoolers require electronics capable of controlling self-induced vibration down to a fraction of a newton and coldhead temperature with high accuracy down to a few kelvin. Other functions include engineering diagnostics, heater and valve control, telemetry and safety protection of the cryocooler subsystem against extreme environments and operational anomalies. The electronics are designed to survive the thermal, vibration, shock and radiation environment of launch and orbit, while providing a design life in excess of 10 years on-orbit. A number of our current generation high reliability radiation-hardened electronics units are in various stages of integration on several space flight payloads. This paper describes the features and performance of our latest flight electronics designed for the pulse-tube cryocooler that is the pre-cooler for a closed cycle Joule-Thomson cooler providing 6K cooling for the James Webb Space Telescope (JWST) Mid Infra-Red Instrument (MIRI). The electronics is capable of highly accurate temperature control over the temperature range from 4K to 15K. Self-induced vibration is controlled to low levels on all harmonics up to the 16th. A unique active power filter controls peak-to-peak reflected ripple current on the primary power bus to a very low level. The 9 kg unit is capable of delivering 360W continuous power to NGAS's 3-stage pulse-tube High-Capacity Cryocooler (HCC).

thermometry↗