Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Net-zero energy building design and life-cycle cost analysis with air-source variable refrigerant flow and distributed photovoltaic systems

Net-zero energy building (NZEB) design has been gaining widespread acceptance as a major driver to reach feasible long-term goals of energy reductions in a building sector for the coming decades. Accordingly, net-zero energy targets for commercial buildings have been specified by federal and/or local government agencies in U.S. Although moving toward NZEB goals has technically feasible long-term advantages, economic issues are one of primarily concerns by building owners and designers for the application of advanced building technologies in NZEB design of their retrofit or new building construction. However, the lack of life cycle cost (LCC) data has still hindered reliable understanding of adopting NZEB design by building owners in a cost-effective manner. In response to this gap, this study conducts life-cycle cost analysis (LCCA) of NZEB design with an energy-efficient heating, ventilation, and air conditioning (HVAC) system and a solar power generation system. Here, to enable NZEB design, an air-source VRF heat pump (HP) type system is considered for energy-efficient HVAC equipment in an office building model with a grid-tied photovoltaic (PV) system. Results reveal that the LCC of NZEBs varies primarily due to a combined effect of annual site EUIs, on-site power generation, and cost-items of each location in U.S. climates. Some hot and mild climate zones in the U.S. represent that LCC values of NZEBs are considerably lower. In contrast, some other cold zones result in unattractive LCC values for NZEBs, caused by a combined effect of relatively lower potential of on-site PV electricity generation and city cost indices. Yet, with subsidized financing by the federal government for PV installation costs, LCC values of NZEBs become significantly attractive in most climate locations.

42 ENGINEERING↗

Implementing the Inflation Reduction Act: What We Expect and How We Might Get There

This presentation summarizes findings from three related studies: Evaluating Impacts of the Inflation Reduction Act and Bipartisan Infrastructure Law on the U.S. Power System; The Roles and Impacts of PV-Battery Hybrids in a Decarbonized U.S. Electricity Supply; and Optimal Design and Deployment of Wind-Solar Hybrids in Low-Carbon U.S. Power System. The compilation of results from these three studies indicate that the Inflation Reduction Act could drive significant deployment of variable renewable energy technologies, but the level of deployment depends on our ability to build new transmission projects (among other factors). Hybrid systems can help, to an extent, to facilitate greater shares of wind/solar with lesser amounts of transmission expansion.

Bipartisan Infrastructure Law↗

First-Principles Study on the Role of Cu and Cl-Based Dopants in NiO

Utilization of wide band gap oxide-based materials in thin-film solar energy technologies has increased in recent years. Among the numerous candidate oxide materials, NiO has shown many desirable optoelectronic properties that are applicable to thin-film PV technologies such as cadmium telluride PV. However, one critical factor requiring further investigation is the p-type doping behavior of NiO, specifically when the cadmium telluride solar cell undergoes conventional processes such as copper doping and chlorine-based activation treatment. The previous literature has shown a large degree of variability in hole concentrations in NiO when copper is used as the primary dopant. This study uses first-principles computational modeling based on density functional theory coupled with defect equilibria calculations to quantitatively explore the role of copper and chlorine-based extrinsic dopants in the p-type doping activity of NiO. The study reveals the importance of extrinsic dopants and their binding interactions with nickel vacancies to effectively p-dope NiO. It is suggested that both the formation of V Ni + Cu Ni and V Ni + Cl O defect pairs under a supersaturated state of NiO are potential mechanisms for increasing hole densities. On the other hand, the production of 2Cu Ni severely limits the effectiveness of p-doping in NiO, even in the presence of the aforementioned defect pairs. Furthermore, the study provides a guideline for experimentalists interested in using copper or chlorine species to understand how to controllably p-dope NiO during thin-film synthesis.

chlorine↗

A Generalized Copula-Polynomial Chaos Expansion for Probabilistic Power Flow Considering Nonlinear Correlations of PV Injections

This paper develops a generalized Copula-polynomial chaos expansion (PCE) framework for power system probabilistic power flow that can handle both linear and nonlinear correlations of uncertain power injections, such as wind and PVs. A data-driven Copula statistical model is used to capture the correlations of uncertain power injections. This allows us to resort to the Rosenblatt transformation to transform correlated variables into independent ones while preserving the dependence structure. This paves the way of leveraging the PCE for surrogate modeling and uncertainty quantification of power flow results, i.e., achieving the probabilistic distributions of power flows. Simulations carried out on the IEEE 57-bus system show that the proposed framework can get much more accurate results than other alternatives with different linear and nonlinear power injection correlations.

copula↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

Probabilistic Risk Assessment of Aging Layered Pressure Vessels

The National Aeronautics and Space Administration (NASA) operates approximately 300 aging layered pressure vessels that were designed and manufactured prior to ASME Boiler and Pressure Vessel (B&PV) code requirements. In order to make decisions regarding the continued fitness-for-service of these non-code carbon steel vessels, it is necessary to perform a relative risk of failure assessment for each vessel. However, risk assessment of these vessels is confounded by uncertainties and variabilities related to the use of proprietary materials in fabrication, missing construction records, geometric discontinuities, weld residual stresses, and complex service stress gradients in and around the welds. Therefore, a probabilistic framework that can capture these uncertainties and variabilities has been developed to assess the fracture risk of flaws in regions of interest, such as longitudinal and circumferential welds, using the NESSUS® probabilistic modeling software and NASGRO® fracture mechanics software. In this study, the probabilistic framework was used to predict variability in the stress intensity factor associated with different reference flaws located in the head-to-shell circumferential welds of a 4-layer and 14-layer pressure vessel. The probabilistic studies predict variability in flaw behavior and the important uncertain parameters for each reference flaw location.

Riha, D. S.↗

Extracting and Generating PV Soiling Profiles for Analysis, Forecasting, and Cleaning Optimization

The identification and prediction of the daily soiling profiles of a photovoltaic site is essential to plan the optimal cleaning schedule. In this article, we analyze and propose various methods to extract and generate photovoltaic soiling profiles, in order to improve the analysis and the forecast of the losses. New soiling rate extraction methods are proposed to reflect the seasonal variability of the soiling rates and, for this reason, are found to identify the most convenient cleaning day with the highest accuracy for the investigated sites. Also, we present an approach that could be used to predict future soiling losses through the implementation of stochastic weather generation algorithms whose ability to identify in advance the best cleaning schedule is also successfully tested. The methods presented in this article can optimize the operation and maintenance schedule and could make it possible, in the future, to predict soiling losses through analysis based only on environmental parameters, such as rainfall and particulate matter, without the need of long-term soiling data.

14 SOLAR ENERGY↗

Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured acceleration factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.

14 SOLAR ENERGY↗

Cost-optimized energy storage operation for a grid-connected solar PV system at community and individual scales

This study provides a comparative analysis of grid-connected PV-integrated battery storage at individual and community scales. The paper addresses the challenge of managing energy demand-generation mismatch by using a battery energy storage optimization algorithm, which minimizes operational costs while accounting for battery degradation. Also, this work introduces a broader evaluation basis that includes seasonal variability, grid exchange smoothness, and scalability across different battery capacities. Results show that community-scale storage more effectively dampens grid exchange power fluctuations and reduces system costs, particularly with moderate price differences between electricity buying and selling prices and low battery capacities. The paper also analyzes the impacts of static control versus cost-optimized battery system management. Here, it is shown that the gap in system costs between the cost-optimized and static control scenarios widens as the price difference increases.

25 ENERGY STORAGE↗

The Future of Renewable Energy Transmission: An Autonomous Energy Grid

The drastic price reduction in variable renewable energy, such as wind and solar, coupled with the ease of use of smart technologies at the consumer level, is driving dramatic changes to the power system that will significantly transform how power is made, delivered, and used. Distributed energy resources (DERs)—which can include solar photovoltaic (PV), fuel cells, microturbines, gensets, distributed energy storage (e.g., batteries, ice storage), and new loads (e.g., electric vehicles (EVs), light-emitting diode (LED) lighting, smart appliances, and electric heat pumps)—are being added to electric grids and causing bidirectional power flows and voltage fluctuations that can impact optimal control and system operation. Residential solar installations, customer battery systems, and EVs are all seeing rapid increases in deployments. With DER seeing such increased use, it is not unreasonable to imagine a residential electricity customer having at least five controllable DERs. In future electric grids, as more DERs are integrated, the number of active control points will be too much for current control approaches to effectively manage.

30 DIRECT ENERGY CONVERSION↗

APERTURE SYNTHESIS IMAGING OF V892 Tau AND PV Cep: DISK EVOLUTION

I present a study of two Herbig Ae stars that are in completely different evolutionary stages: V892 Tau and PV Cep. Using sub-arcsecond interferometric observations obtained with the Combined Array for Research in Millimeter-wave Astronomy at {lambda} = 1.3 and 2.7 mm, I have for the first time resolved their disks. I deduce that the 5 Myr old V892 Tau has a low dust opacity index {beta} = 1.1 and a disk mass of {approx}0.03 M{sub sun}. These values correspond to the growth of its dust into large, up to centimeters size, structures. In contrast, the very young (a few x10{sup 5} yr) PV Cep has a quite high opacity index {beta} = 1.75 and a more massive disk 0.8 M{sub sun}. PV Cep has the youngest resolved disk around any Herbig Ae star. Unlike the youngest T Tauri and Class 0 stars, which contain large and processed grains, the young Herbig Ae star, PV Cep, disk contains interstellar-medium-like unprocessed dust. This suggests that PV Cep's dust evolution is slower than T Tauri stars'. I also present high spatial resolution interferometric observations of the PV Cep outflow. The outflow inclination is consistent with the orientation of the known Herbig-Haro flow in that region, HH315.

79 ASTRONOMY AND ASTROPHYSICS↗

Nondestructive Characterization of Antireflective Coatings on PV Modules

Antireflective coatings (ARCs) are used on the vast majority of solar photovoltaic (PV) modules to increase power production. However, ARC longevity can vary from less than 1 to over 15 years depending on coating quality and deployment conditions. A technique that can quantify ARC degradation nondestructively on commercial modules would be useful both for in-field diagnostics and accelerated aging tests. In this article, we demonstrate that accurate measurements of ARC spectral reflectance can be performed using a modified commercially available integrating-sphere probe. The measurement is fast, accurate, nondestructive, and can be performed outdoors in full-sun conditions. We develop an interferometric model that estimates coating porosity, thickness, and fractional area coverage from the measured reflectance spectrum for a uniform single-layer coating. We demonstrate the measurement outdoors on an active PV installation, identify the presence of an ARC, and estimate the properties of the coating.

14 SOLAR ENERGY↗

An investigation of the key parameters for predicting PV soiling losses

One hundred and two environmental and meteorological parameters have been investigated and compared with the performance of 20 soiling stations installed in the USA, in order to determine their ability to predict the soiling losses occurring on PV systems. The results of this investigation showed that the annual average of the daily mean particulate matter values recorded by monitoring stations deployed near the PV systems are the best soiling predictors, with coefficients of determination ( R 2 ) as high as 0.82. The precipitation pattern was also found to be relevant: among the different meteorological parameters, the average length of dry periods had the best correlation with the soiling ratio. Lastly, a preliminary investigation of two-variable regressions was attempted and resulted in an adjusted R 2 of 0.90 when a combination of PM 2.5 and a binary classification for the average length of the dry period was introduced.

14 SOLAR ENERGY↗

Modeling needs for very large systems.

Most system performance models assume a point measurement for irradiance and that, except for the impact of shading from nearby obstacles, incident irradiance is uniform across the array. Module temperature is also assumed to be uniform across the array. For small arrays and hourly-averaged simulations, this may be a reasonable assumption. Stein is conducting research to characterize variability in large systems and to develop models that can better accommodate large system factors. In large, multi-MW arrays, passing clouds may block sunlight from a portion of the array but never affect another portion. Figure 22 shows that two irradiance measurements at opposite ends of a multi-MW PV plant appear to have similar irradiance (left), but in fact the irradiance is not always the same (right). Module temperature may also vary across the array, with modules on the edges being cooler because they have greater wind exposure. Large arrays will also have long wire runs and will be subject to associated losses. Soiling patterns may also vary, with modules closer to the source of soiling, such as an agricultural field, receiving more dust load. One of the primary concerns associated with this effort is how to work with integrators to gain access to better and more comprehensive data for model development and validation.

14 SOLAR ENERGY↗

Economic Assessment of Nuclear Hybrid Energy Systems: Nuclear-Renewable-Water Integration in Arizona

One of the goals of the Nuclear-Renewable Hybrid Energy Systems (N-R HES) modeling and simulation (M&S) project is to assess the economic viability of N-R HES in a market that contains Variable Renewable Energy (VRE) sources like solar. The N-R HES M&S project is a multi-laboratory effort, led by Idaho National Laboratory (INL) and supported by Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL). Development of the N-R HES software framework was initiated at INL in 2016 [1] and has reached some level of maturity such that it can be applied to more than simple demonstration cases, e.g. real industry problems. Nevertheless, more capabilities are constantly added to accommodate the special needs of challenging, real-life problems. The N-R HES framework is built on the Risk Analysis Virtual ENvironment (RAVEN) code [2], which it uses as a driver and workflow manager for all calculations. There are four main cornerstones of the N-R HES simulation framework: 1) The generation of stochastic synthetic time series. 2) A set of probabilistic analysis and optimization algorithms available in RAVEN. 3) A set of models for representing the physical behavior of N-R HES. These can be reduced-order models or high-fidelity Modelica [3] models. 4) The RAVEN plug-in called CashFlow [4] that maps physical performance into economic performance. Within this framework, a broad spectrum of questions related to N-R HES can be addressed. One of the challenges currently of high interest is the increasing penetration of VRE altering the profile of the net demand (demand after removing all non-curtailable renewable energy sources, e.g. rooftop solar). The N-R HES software framework is capable of analyzing the potential feasibility of mitigating the resultant volatility in the net electricity demand. One possible solution to manage net demand volatility is adding stabilizing loads to the grid. These loads can be external industrial processes that are able to ramp production up and down quickly, or for regulated markets, adding variable internal loads that will effectively increase the baseload of the power plant and therefore reduce the risk of internal demand that is lower than the capacity of the power plant. The latter is a possible solution currently being considered by Arizona Public Service (APS), the operating owner of the Palo Verde (PV) Nuclear Power Plant (NPP).

97 MATHEMATICS AND COMPUTING↗

Overcoming Communications Outages in Inverter Downtime Analysis: Preprint

Inverters are often reported to be the highest-impact failure point in PV systems. This importance is belied by the simplistic assumptions about inverter downtime losses used in industrial energy modeling. Energy models often assume the extent of inverter-related losses is limited to 1% of annual production from scheduled inverter preventative maintenance. In reality, inverter-related production losses are much more variable, although data from large-scale surveys of fielded systems are rare. Here we present a method of detecting inverter downtime events and estimating the associated lost production using inverter- and meter-level power data. Because communications outages are of similar frequency to true production outages, the method pays particular attention to distinguishing communications outages from true production outages. The results of applying the method at fleet-scale are presented and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

National Solar Radiation Database (NSRDB)

The National Solar Radiation Database (NSRDB) is a serially complete collection of meteorological and solar irradiance data sets for the United States and a growing list of international locations for 1998-2023. The NSRDB is updated annually and provides foundational information to support U.S. Department of Energy programs, research, industry and the general public. The NSRDB provides time-series data at 30-minute resolution of resource averaged over surface cells of 0.038 degrees in both latitude and longitude, or nominally 4 km in size. Additionally time series data at 5 minutes for the US and 10 minutes for North, Central and South America at 2 km resolution are produced from the next generation of GOES satellites and made available from 2019. The solar radiation values represent the resource available to solar energy systems. The data was created using cloud properties which are generated using the AVHRR Pathfinder Atmospheres-Extended (PATMOS-x) algorithms developed by the University of Wisconsin. Fast all-sky radiation model for solar applications (FARMS) in conjunction with the cloud properties, and aerosol optical depth (AOD) and precipitable water vapor (PWV) from ancillary source are used to estimate solar irradiance (GHI, DNI, and DHI). The Global Horizontal Irradiance (GHI) is computed for clear skies using the REST2 model. For cloud scenes identified by the cloud mask, FARMS is used to compute GHI and FARMS DNI is used to compute the Direct Normal Irradiance (DNI). The PATMOS-X model uses radiance images in visible and infrared channels from the Geostationary Operational Environmental Satellite (GOES) series of geostationary weather satellites. Ancillary variables needed to run REST2 and FARMS (e.g., aerosol optical depth, precipitable water vapor, and albedo) are derived from NASA's Modern Era-Retrospective Analysis (MERRA-2) dataset. Temperature and wind speed data are also derived from MERRA-2 and provided for use in NREL's System Advisor Model (SAM) to compute PV generation.

aerosol↗