At least 451 records · Page 25

Analysis of contamination data recorded by the IECM camera/photometer

The Camera/Photometer was one of the ten instruments comprising the Induced Environment Contamination Monitor (IECM) developed to monitor the contamination about the Space Shuttle Orbiter during early missions. This experiment consisted of two motion picture cameras, integrating photometers, and associated electronics enclosed in pressurized canisters and separated by 40 cm in order to make stereoscopic observation of particulates. The objectives of the experiment were to record the occurrence of particulates and to determine their velocities, sizes and origins, as well as to measure the background brightness due to unresolved particles. Particle tracks were detected on over 1800 data frames recorded during continuous operations throughout STS-2, -3, -4, and -9. This report discusses the analysis techniques employed in reducing subsequent results, with an emphasis placed on particle size and velocity data. It also describes the operation of the overall experiment and some of the results obtained.

Clifton, K. Stuart↗

Microbial Monitoring of the International Space Station

Humans living and working in the harsh environment of space present many challenges for habitability engineers and microbiologists. Spacecraft must provide an internal environment in which physical (gas composition, pressure, temperature, and humidity), chemical, and biological environmental parameters are maintained at safe levels. Microorganisms are ubiquitous and will accompany all human-occupied spacecraft, but if biological contamination were to reach unacceptable levels, long-term human space flight would be impossible. Prevention of microbiological problems, therefore, must have a high priority. Historically, prevention of infectious disease in the crew has been the highest priority, but experience gained from the NASA-Mir program showed that microbial contamination of vehicle and life-support systems, such as biofouling of water and food, are of equal importance. The major sources of microbiological risk factors for astronauts include food, drinking water, air, surfaces, payloads, research animals, crew members, and personnel in close contact with the astronauts. In our efforts to eliminate or mitigate the negative effects of microorganisms in spacecraft, the National Aeronautics and Space Administration (NASA) implemented comprehensive microbial analyses of the major risk factors. This included the establishment of acceptability requirements for food, water, air, surfaces, and crew members. A robust monitoring program was then implemented to verify that the risks were within acceptable limits. Prevention of microbiological problems is preferred over mitigation of problems during flight, and preventive steps must begin very early in the design phase. Spacecraft development must include requirements to control free water from humidity, condensate, hygiene activities, and other releases. If water is available, microbes are likely to grow because sufficient nutrients are potentially available. Materials selected for the spacecraft must not promote or support microbial growth. Air filtration can dramatically reduce the number of airborne bacteria, fungi, and particulates in spacecraft breathing air. Waterborne bacteria can be reduced to acceptable levels by thermal inactivation of bacteria during water processing, along with a residual biocide, and filtration at the point of use can ensure safety. System design must include onboard capability to achieve recovery of the system from contamination. Robust housekeeping procedures that include periodic cleaning and disinfection will prevent high levels of microbial growth on surfaces. Food for consumption in space must be thoroughly tested for excessive microbial content and pathogens before launch. Thorough preflight examination of flight crews, consumables, payloads, and the environment can greatly reduce pathogens in spacecraft. Many of the lessons learned from the Space Shuttle and previous programs were applied in the early design phase of the International Space Station, resulting in the safest space habitat to date. This presentation describes the monitoring program for the International Space Station and will summarize results from preflight and on-orbit monitoring.

Pierson, Duane L.↗

ALGE Contaminant Transport Model for Emergency Response

Model Description • ALGE is a 3-dimensional hydrodynamic code to predict the movement of a dissolved tracer throughout a water body. • It has been recoded as an emergency response tool. • Can model large-scale bays and estuaries (Chesapeake Bay, Lake Michigan, etc.) • Model includes suspended sediment transport, dissolved and particulate chemical transport, radioactive decay, and dynamic salinity.

Werth, David W.↗

The formation of spinel-group minerals in contaminated soils: the sequestration of metal(loid)s by unexpected incidental nanoparticles

Mineralogical studies of contaminated soils affected by smelter emission and dust from mining activities indicate that minerals of the spinel group are one of the common hosts of metal-bearing contaminants. Spinel group minerals typically originate from high temperature processes, but an increasing number of studies indicate that metal-bearing spinel group minerals can also form under ambient Earth surface conditions in surficial soils. In this contribution to honor Donald Sparks, we show that the spinels Zn-bearing magnetite (Zn 0.5 Fe 2.5 O 4 ) and minium (Pb 3 O 4 ) form during low temperature alteration of Pb-bearing silica glass in surficial organic rich soils in proximity to a former Cu-smelter in Timmins, Ontario, Canada. The glass most likely formed during high-temperature processes and has been either emitted by the smelter or wind-blown from waste rock piles to near-by soils. The alteration of the glass by percolating pore solutions has resulted in the formation of large micrometer-size dendritic etch features and in nanometer-size dendritic alteration halos composed of nano-size prismatic crystals of Zn-rich magnetite and spherical nanoparticles of minium. Both spinel-type phases are embedded in an amorphous silica matrix which formed during the alteration of the glass at low temperature. A review on the occurrence of spinel-group minerals in smelter-affected soils or mine tailings indicates that the formation of these minerals under ambient Earth surface conditions is quite common and often results in the sequestration of contaminants such as Cu, Ni, Zn and Sb. The pedogenic spinels often occur as euhedral crystals in nano-size mineral assemblages within alteration features such as dendritic etch patterns, mineral surface coatings and mineralized organic matter. Their well-developed crystal forms indicate that (a) they have not formed during a rapid cooling process in a smelter or refinery which typically creates spherical particulate matter, and (b) they have not been part of particulate matter added via fluvial or Aeolian processes which most commonly yield anhedral morphologies. The formation of nano-size spinel-group minerals in low temperature environmental settings may lead to the long-term storage of metal(loid)s in mineral phases and their transport over vast distances via fluvial, alluvial and Aeolian processes.

58 GEOSCIENCES↗

Further Characterization of Aerosols Sampled on the International Space Station

Spacecraft cabin air quality is of fundamental importance to crew health, with concerns encompassing both gaseous contaminants and airborne particles. Quantification of spacecraft indoor aerosols will increase our understanding of crew exposure and cabin cleanliness. Aerosols on the International Space Station (ISS) have been sampled and brought back to Earth for analysis to characterize the airborne particulate matter in the cabin. Microscopic analyses have been performed to determine morphology and particle size information, and Energy Dispersive X-ray Spectroscopy (EDS) provides information on the chemical elements present in the particles. With the use of IntelliSEM software for computer-controlled scanning electron microscopy (CCSEM), this data provides particle size distribution information and statistics on particle materials. Many of the particles collected were made up of multiple elements and had uncommon morphologies compared to typical indoor aerosols on Earth. These characteristics are thought to be from unique formation mechanisms in the microgravity environment. Several notable particle types are examined further in this work. Bromine-containing particles and cadmium-containing particles are discussed as they constitute a health hazard to crew members. Humans in indoor living and working spaces are typically the single largest particle emission source, and this was observed in the sampled aerosols in ISS as well.

Sampling↗

Waste Encapsulation and Storage Facility Stabilization and Ventilation Project-18121

Department of Energy contractor CH2M HILL Plateau Remediation Company (CH2M) is responsible for the safe and compliant operation of the Waste Encapsulation and Storage Facility (WESF), a nuclear materials storage facility at Hanford containing 1,936 highly radioactive capsules containing cesium and strontium. The capsules are currently stored under approximately 4 m (13 ft) of water. The water shields workers from radiation and helps cool the capsules. WESF is a large, concrete structure nominally 48 m (160 ft) long, 30 m (98 ft) wide and 12 m (40 ft) high with the pool cells being approximately 4 m (13 ft) below grade level. It is a robust facility with walls ranging from 0.3 m to 1 m (1 ft to 3 ft) thick. While the capsules are currently in a safe configuration, WESF is an aging facility, and DOE and CH2M are modifying the facility to ensure continued safe and compliant operations and to support the eventual transfer of capsules to dry storage. Dry storage would eliminate the possibility of a release of radioactive material in the unlikely event of a major earthquake that might result in loss of pool storage water and overheating and breach of one or more capsules. The project was divided into two major deliverables: 1) Ventilation: replacement of the existing ventilation system which included a below-grade high efficiency particulate air (HEPA) filter pit with an above grade HEPA filter skid and new fans and ducting. 2) Stabilization: grouting deactivated facility hot cells and other void spaces to the maximum extent practical to reduce material at risk from legacy contamination. The aging ventilation system relied on HEPA filters that exceeded their operational life. Due to the high levels of radionuclide contamination, replacing the filters was impractical and highly hazardous. CH2M installed a new ventilation system to provide safe and compliant ventilation for future operations. The project used an existing, unused ventilation skid that was designed for another project. Repurposing the unused skid presented additional technical challenges to modify the system for the project specific requirements. The new system is above ground, easier to maintain and is built to current standards. New connections inside the facility were installed to allow the new ventilation to operate effectively. The stabilization project is unique in that core drilling and grouting was performed in an operating Hazard Category 2 nuclear facility, which brought forth safety basis and environmental regulatory challenges. The hot cells were isolated from all existing support utilities including electrical, process chemicals, manipulator ports, instrument air, etc. to seal the hot cells and prevent highly contaminated supernate or grout from leaking into adjacent galleries. A high flow grout was used to maximize the distance between injection ports. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reassessment of Resuspension Factor Following Radionuclide Dispersal: Toward a General-purpose Rate Constant

A recent analysis of historical radionuclide resuspension datasets confirmed the general applicability of the Anspaugh and modified Anspaugh models of resuspension factors following both controlled and disastrous releases. While observations appear to have larger variance earlier in time, previous studies equally weighted the data for statistical fit calculations; this could induce a positive skewing of resuspension coefficients in the early time-period. A refitting is performed using a relative instrumental weighting of the observations. Measurements within a 3-d window are grouped into singular sample sets to construct standard deviations. The resulting best-fit equations produce tamer exponentials, which give decreased integrated resuspension factor values relative to those reported by Anspaugh. As expected, the fits attenuate greater error among the data at earlier time. In conclusion, the reevaluation provides a sharper contrast between the empirical models and reaffirms their deficiencies in the short-lived timeframe wherein the dynamics of particulate dispersion dominate the resuspension process.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Rust Contamination from Water Leaks in the Cosmic Dust Lab and Lunar and Meteorite Thin Sections Labs at Johnson Space Center

On the early morning of September 15th, 2016, on the first floor of Building 31 at NASA-Johnson Space Center, the hose from a water chiller ruptured and began spraying water onto the floor. The water had been circulating though old metal pipes, and the leaked water contained rust-colored particulates. The water flooded much of the western wing of the building's ground floor before the leak was stopped, and it left behind a residue of rust across the floor, most notably in the Apollo and Meteorite Thin Section Labs and Sample Preparation Lab. No samples were damaged in the event, and the affected facilities are in the process of remediation. At the beginning of 2016, a separate leak occurred in the Cosmic Dust Lab, located in the same building. In that lab, a water leak occurred at the bottom of the sink used to clean the lab's tools and containers with ultra-pure water. Over years of use, the ultra-pure water eroded the metal sink piping and leaked water onto the inside of the lab's flow bench. This water also left behind a film of rusty material. The material was cleaned up and the metal piping was replaced with PVC pipe and sealed with Teflon plumber's tape. Samples of the rust detritus were collected from both incidents. These samples were imaged and analyzed to determine their chemical and mineralogical compositions. The purpose of these analyses is to document the nature of the detritus for future reference in the unlikely event that these materials occur as contaminants in the Cosmic Dust samples or Apollo or Meteorite thin sections.

Kent, J. J.↗

Enhanced Photovoltaic Soiling in an Urban Environment

Natural soiling, or the deposition of ambient particulate matter (PM) onto the surface of solar glass, causes losses in PV production around the world. Much work in the PV community has focused on soiling in dusty desert environments. However, PV systems in urban environments are exposed to different contaminants and thus soil differently. We present an analysis of PV soiling in such an urban environment considering the impacts of meteorological parameters. We present 1 year of results from a soiling station in an urban location in Colorado. Bare glass samples were exposed outdoors for 11 days alongside the station; results from microscopy and light transmittance measurements show how moisture and dew affect the morphology and optics of contamination on glass. The coupon results suggest that natural (rain) cleanings may not be sufficient to clean solar panels in urban environments. Ion chromatography of soiling on the reference cell surfaces suggest that dry brush cleanings may not sufficiently clean chemicals deposited on solar panel surfaces in urban environments.

14 SOLAR ENERGY↗

Induced environment contamination monitor (IECM) cascade impactor

The Cascade Impactor on the IECM is an aerosol sampling instrument which employs three cascade impaction-type nozzles of progressively smaller diameter. The considered approach makes it possible to achieve particle size discrimination involving three ranges (5 microns and larger, 1 to 5 microns, and 0.3 to 1 micron). In addition to the particulate measuring cascade stages, a fourth quartz crystal microbalance measures the cumulative airborne molecular nonvolatile residue (NVR) at ambient temperature. The cascade measurements provide a temporal record of the payload bay's particulate environment during ascent, descent, and immediate postlanding periods. The NVR stage functions throughout the mission. Particulates of a size greater than five microns in diameter were below 10 micrograms per cu m throughout the mission.

Duncan, B. J.↗

Enhanced and stabilized arsenic retention in microcosms through the microbial oxidation of ferrous iron by nitrate

Magnetite strongly retains As, and is relatively stable under Fe(III)-reducing conditions common in aquifers that release As. In this paper, laboratory microcosm experiments were conducted to investigate a potential As remediation method involving magnetite formation, using groundwater and sediments from the Vineland Superfund site. The microcosms were amended with various combinations of nitrate, Fe(II) (aq) (as ferrous sulfate) and lactate, and were incubated for more than 5 weeks. In the microcosms enriched with 10 mM nitrate and 5 mM Fe(II) (aq) , black magnetic particles were produced, and As removal from solution was observed even under sustained Fe(III) reduction stimulated by the addition of 10 mM lactate. The enhanced As retention was mainly attributed to co-precipitation within magnetite and adsorption on a mixture of magnetite and ferrihydrite. Sequential chemical extraction, X-ray absorption spectroscopy and magnetic susceptibility measurements showed that these minerals formed at pH 6–7 following nitrate-Fe(II) addition, and As-bearing magnetite was stable under reducing conditions. Scanning electron microscopy and X-ray diffraction indicated that nano-particulate magnetite was produced as coatings on fine sediments, and no aging effect was detected on morphology over the course of incubation. Finally, these results suggest that a magnetite based strategy may be a long-term remedial option for As-contaminated aquifers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biostimulated uranium immobilization within aquifers – from bench scale to field experiments

In situ bioremediation of uranium-contaminated aquifers through microbially catalyzed reduction of mobile U(VI) species can only be successful if the U(IV) products are immobilized over long time-scales. Although uraninite is known for its low solubility and has been produced in nano-particulate form by several species of metal- and sulfate-reducing bacteria in laboratory studies, little is known about the stability of biogenic U(IV) in the subsurface. Using an up-scaling approach, we investigated the chemical and environmental stability of biogenic UO₂ nano-solids. Our results show that diffusive limitations due to aquifer porosity and microstructure may retard uraninite corrosion. Corrosion was also retarded by adsorption or incorporation of manganese. On the other hand, U(VI) bioreduction in field sediments generated U(IV) that was more labile than biogenic UO₂.

bioremediation↗

Design and Certification of the Extravehicular Activity Mobility Unit (EMU) Water Processing Jumper

The Extravehicular Mobility Units (EMUs) onboard the International Space Station (ISS) experienced a failure due to cooling water contamination from biomass and corrosion byproducts forming solids around the EMU pump rotor. The coolant had no biocide and a low pH which induced biofilm growth and corrosion precipitates, respectively. NASA JSC was tasked with building hardware to clean the ionic, organic, and particulate load from the EMU coolant loop before and after Extravehicular Activity (EVAs). Based on a return sample of the EMU coolant loop, the chemical load was well understood, but there was not sufficient volume of the returned sample to analyze particulates. Through work with EMU specialists, chemists, (EVA) Mission Operations Directorate (MOD) representation, safety and mission assurance, astronaut crew, and team engineers, requirements were developed for the EMU Water Processing hardware (sometimes referred to as the Airlock Coolant Loop Recovery [A/L CLR] system). Those requirements ranged from the operable level of ionic, organic, and particulate load, interfaces to the EMU, maximum cycle time, operating pressure drop, flow rate, and temperature, leakage rates, and biocide levels for storage. Design work began in February 2005 and certification was completed in April 2005 to support a return to flight launch date of May 12, 2005. This paper will discuss the details of the design and certification of the EMU Water Processing hardware and its components

Peterson, Laurie J.↗

Quantifying the Impact of Excluding the Submersion Exposure Route for Existing Superfund Radionuclide Screening Level Calculator Soil and Tap Water Models

The U.S. Environmental Protection Agency (EPA) provides initial data screening guidelines for radionuclide-contaminated Superfund sites using preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs). PRGs and DCCs are target concentration values based on acceptable excess lifetime cancer risk and annual dose limits, respectively. They are calculated for various environmental media that may be encountered by residential and worker land uses. PRGs and DCCs typically consist of multiple exposure routes. One of these routes is submersion, which is exposure to a gaseous or particulate radionuclide that is suspended in air. Currently, submersion is only included in air calculations. This study focused on determining whether factoring submersion into total PRG/DCC calculations for soil and tap water created a significant difference in the target concentrations. New equations for individual submersion PRGs/DCCs for each land use of interest for soil and tap water were developed. A wind-driven particulate emission factor and Andelman’s constant were used to model the amount of soil and vapor in the air from soil and household use of tap water, respectively. The submersion PRG/DCC was then included in the total PRG/DCC for each radionuclide, followed by a percent difference comparison of the old and new totals to quantify the impact of the change. For total soil PRGs/DCCs, with and without submersion, the difference was less than 1 percent; however, many of the tap water radionuclides analyzed – including multiple radon and polonium isotopes – showed as high as a 200 percent difference.This technical memorandum (TM) presents recommendations for updates to current EPA guidelines for initial data screens of radionuclide contaminated tap water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Institutional impediments to using alternative water sources in thermoelectric power plants.

This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements the Existing Plants Research Program's overall research effort by evaluating water issues that could impact power plants. Obtaining adequate water supplies for cooling and other operations at a reasonable cost is a key factor in siting new and maintaining existing thermoelectric power plant operations. One way to reduce freshwater consumption is to use alternative water sources such as reclaimed (or recycled) water, mine pool water, and other nontraditional sources. The use of these alternative sources can pose institutional challenges that can cause schedule delays, increase costs, or even require plants to abandon their plans to use alternative sources. This report identifies and describes a variety of institutional challenges experienced by power plant owners and operators across the country, and for many of these challenges it identifies potential mitigating approaches. The information comes from publically available sources and from conversations with power plant owners/operators familiar with using alternative sources. Institutional challenges identified in this investigation include, but are not limited to, the following: (1) Institutional actions and decisions that are beyond the control of the power plant. Such actions can include changes in local administrative policies that can affect the use of reclaimed water, inaccurate growth projections regarding the amount of water that will be available when needed, and agency workloads and other priorities that can cause delays in the permitting and approval processes. (2) Developing, cultivating, and maintaining institutional relationships with the purveyor(s) of the alternative water source, typically a municipal wastewater treatment plant (WWTP), and with the local political organizations that can influence decisions regarding the use of the alternative source. Often a plan to use reclaimed water will work only if local politics and power plant goals converge. Even then, lengthy negotiations are often needed for the plans to come to fruition. (3) Regulatory requirements for planning and developing associated infrastructure such as pipelines, storage facilities, and back-up supplies that can require numerous approvals, permits, and public participation, all of which can create delays and increased costs. (4) Permitting requirements that may be difficult to meet, such as load-based discharge limits for wastewater or air emissions limitations for particulate matter (which will be in the mist of cooling towers that use reclaimed water high in dissolved solids). (5) Finding discharge options for cooling tower blowdown of reclaimed water that are acceptable to permitting authorities. Constituents in this wastewater can limit options for discharge. For example, discharge to rivers requires National Pollutant Discharge Elimination System (NPDES) permits whose limits may be difficult to meet, and underground injection can be limited because many potential injection sites have already been claimed for disposal of produced waters from oil and gas wells or waters associated with gas shale extraction. (6) Potential liabilities associated with using alternative sources. A power plant can be liable for damages associated with leaks from reclaimed water conveyance systems or storage areas, or with mine water that has been contaminated by unscrupulous drillers that is subsequently discharged by the power plant. (7) Community concerns that include, but are not limited to, increased saltwater drift on farmers fields; the possibility that the reclaimed water will contaminate local drinking water aquifers; determining the 'best' use of WWTP effluent; and potential health concerns associated with emissions from the cooling towers that use recycled water. (8) Interveners that raise public concerns about the potential for emissions of emerging pollutants of concern to cause health or environmental problems. Mitigating solutions range from proactive communications with the local communities (which can be implemented by the power plants) to technical solutions, such as developing means to reduce the concentrations of total dissolved solids (TDS) and other contaminants in cooling water to maintain plant efficiency and while meeting discharge limits. These kinds of solutions may be appropriate for DOE research and development (R&D) funding.

03 NATURAL GAS↗