At least 451 records · Page 25

GLAD-M35: a joint P and S global tomographic model with uncertainty quantification

We present our third and final generation joint P and S global adjoint tomography (GLAD) model, GLAD-M35, and quantify its uncertainty based on a low-rank approximation of the inverse Hessian. Starting from our second-generation model, GLAD-M25, we added 680 new earthquakes to the database for a total of 2160 events. New P-wave categories are included to compensate for the imbalance between P- and S-wave measurements, and we enhanced the window selection algorithm to include more major-arc phases, providing better constraints on the structure of the deep mantle and more than doubling the number of measurement windows to 40 million. Two stages of a Broyden–Fletcher–Goldfarb–Shanno (BFGS) quasi-Newton inversion were performed, each comprising five iterations. With this BFGS update history, we determine the model’s standard deviation and resolution length through randomized singular value decomposition.

58 GEOSCIENCES↗

Uncertainty Aware Deep Learning for Fault Prediction Using Multivariate Time Series Signals

The superconducting radio-frequency cavities are a crucial component of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. When a cavity faults, beam delivery to experimental end users is disrupted. Prediction of cavity faults prior to onset is essential to reduce operation and maintenance costs. In this work, a parallel long short-term memory (LSTM)-convolution neural network (CNN)-based deep learning (DL) model is proposed to predict impending faults using pre-fault signals. Further, we introduce an uncertainty quantification approach using Monte Carlo dropout with the LSTM-CNN model to ascertain confidence in the prediction. The model was tested using multivariate time series signals from stable cavity operations and before faults. Initial results show that on the test dataset, the model can identify impending faults before their onset with an average 10-fold cross validation accuracy of 97.39% and a standard deviation of 0.12% using a 100-ms time window. It is also observed that the model performs better as the prediction time moves closer to the fault onset. For additional context, we compare the performance of the model with three machine-learning-based (ML) fault prediction models. Our proposed parallel LSTM-CNN-based DL method shows better performance than the ML-based methods.

Rahman, Md Monibor↗

SU-F-T-564: 3 Year Experience of Treatment Plan QualityAssurance for Vero SBRT Patients

Purpose: To verify treatment plan monitor units from iPlan treatment planning system for Vero Stereotactic Body Radiotherapy (SBRT) treatment using both software-based and (homogeneous and heterogeneous) phantom-based approaches. Methods: Dynamic conformal arcs (DCA) were used for SBRT treatment of oligometastasis patients using Vero linear accelerator. For each plan, Monte Carlo calculated treatment plans MU (prescribed dose to water with 1% variance) is verified first by RadCalc software with 3% difference threshold. Beyond 3% differences, treatment plans were copied onto (homogeneous) Scanditronix phantom for non-lung patients and copied onto (heterogeneous) CIRS phantom for lung patients and the corresponding plan dose was measured using a cc01 ion chamber. The difference between the planed and measured dose was recorded. For the past 3 years, we have treated 180 patients with 315 targets. Out of these patients, 99 targets treatment plan RadCalc calculation exceeded 3% threshold and phantom based measurements were performed with 26 plans using Scanditronix phantom and 73 plans using CIRS phantom. Mean and standard deviation of the dose differences were obtained and presented. Results: For all patient RadCalc calculations, the mean dose difference is 0.76% with a standard deviation of 5.97%. For non-lung patient plan Scanditronix phantom measurements, the mean dose difference is 0.54% with standard deviation of 2.53%; for lung patient plan CIRS phantom measurements, the mean dose difference is −0.04% with a standard deviation of 1.09%; The maximum dose difference is 3.47% for Scanditronix phantom measurements and 3.08% for CIRS phantom measurements. Conclusion: Limitations in secondary MU check software lead to perceived large dose discrepancies for some of the lung patient SBRT treatment plans. Homogeneous and heterogeneous phantoms were used in plan quality assurance for non-lung patients and lung patients, respectively. Phantom based QA showed the relative good agreement between iPlan calculated dose and measured dose.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Evaluation of the Use of Direct Electron Density CT Images in Radiation Therapy

Purpose: The current standard for calculation of photon and electron dose requires conversion of Hounsfield Units (HU) to Electron Density (ED) by applying a calibration curve specifically constructed for the corresponding CT tube voltage. This practice limits the use of the CT scanner to a single tube voltage and hinders the freedom in the selection of optimal tube voltage for better image quality. The objective of this study is to report a prototype CT reconstruction algorithm that provides direct ED images from the raw CT data independently of tube voltages used during acquisition. Methods: A tissue substitute phantom was scanned for Stoichiometric CT calibrations at tube voltages of 70kV, 80kV, 100kV, 120kV and 140kV respectively. HU images and direct ED images were acquired sequentially on a thoracic anthropomorphic phantom at the same tube voltages. Electron densities converted from the HU images were compared to ED obtained from the direct ED images. A 7-field treatment plan was made on all HU and ED images. Gamma analysis was performed to demonstrate quantitatively dosimetric change from the two schemes in acquiring ED. Results: The average deviation of EDs obtained from the direct ED images was −1.5%±2.1% from the EDs from HU images with the corresponding CT calibration curves applied. Gamma analysis on dose calculated on the direct ED images and the HU images acquired at the same tube voltage indicated negligible difference with lowest passing rate at 99.9%. Conclusion: Direct ED images require no CT calibration while demonstrate equivalent dosimetry compared to that obtained from standard HU images. The ability of acquiring direct ED images simplifies the current practice at a safer level by eliminating CT calibration and HU conversion from commissioning and treatment planning respectively. Furthermore, it unlocks a wider range of tube voltages in CT scanner for better imaging quality while maintaining similar dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Achromatic digital speckle pattern interferometer with constant radial in-plane sensitivity by using a diffractive optical element

We report on a digital speckle pattern interferometer that applies a binary diffractive optical element (DOE) to generate double illumination and radial in-plane sensitivity. The application of the DOE ensures independence on the wavelength of the laser used as an illumination source. Furthermore, in-plane sensitivity only depends on the grating period of the DOE. An experimental setup was built allowing the measurement of a set of radial in-plane displacement fields either using a red laser as a light source or a green one. When displacement fields computed from the measured optical phase maps obtained with a red or a green laser were compared, two main results were observed: (a) deviations between mean values ranged only up to 7 nm and (b) phase maps presented the same amount of fringes. In addition, phase maps measured with the red laser were processed as they were obtained with green light. For this case, deviations have ranged only up to 0.5 nm. On the other hand, a set of measurements performed changing the DOE by a conical mirror showed clearly that radial in-plane sensitivity increased when the red laser was changed by the green one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Line Design and Beam Physics Study of Energy Recovery Linac Free Electron Laser at Peking University

Energy recovering linac (ERL) offers an attractive alternative for generating intense beams of charged particles by approaching the operational efficiency of a storage ring while maintaining the superior beam quality typical of a linear accelerator. In ERLs, the decelerated beam cancels the beam loading effects of the accelerated beam with high repetition rate. Therefore, ERLs can, in principle, accelerate very high average currents with only modest amounts of RF power. So the efficiency of RF power to beam is much higher. Furthermore, the energy of beam to dump is lower, so it will reduce dump radiation. With the successful experiments in large maximum-to-injection energy ratio up to 51:1 and high power FEL up to 14kW, the use of ERL, especially combining with superconducting RF technology, provides a potentially powerful new paradigm for generation of the charged particle beams used in MW FEL, synchrotron radiation sources, high-energy electron cooling devices and so on. The 3+1/2 DC-SC photo injector and two 9cell TESLA superconducting cavity for IR SASE FEL in PKU provides a good platform to achieve high average FEL with Energy Recovery. The work of this thesis is on Beam line design and Beam dynamics study of Energy Recovery Linac Free Electron Laser for Peking University. It is the upgrade of PKU facility, which is under construction. With ERL, this facility can work in CW mode, so it can operate high average beam current without RF power constraint in main linac and generate high average FEL power. Moreover, it provides a test facility to study the key technology in ERL. System parameters are optimized for PKU ERL-FEL. The oscillation FEL output power is studied with different bunch charge, transverse emittance, bunch length and energy spread. The theory of optimal RF power and Q{sub ext} with ERL and without ERL is analyzed and applied to PKU injector and linac including microphonic effect. pace charge effect in the injector and merger is studied for beam energy at ~5MeV. Simulation shows that in the 3+1/2 DC- C injector, there is a region the beam could be over focused by RF electromagnetic field and the transverse emittance in the transport line up to linac will increase instantly due to over focusing. In order to eliminate this effect on beam emittance, several solutions are investigated to avoid over focusing. This result is very important for beam loading experiment for low bunch charge operation. Meanwhile, different merger structures are compared in terms of error sensitivity and emittance increase with space charge effect. In recirculation beam line, a new symmetric 180{degree} arc structure is designed. It fulfills the achromatic condition and adjustable bunch compression. These two parameters are controlled by different Quads knob. With this novel structure, the recirculation lattice can achieve path length adjustment, bunch compression and decompression in a large range. With beamline error, the beam central orbit will deviate from the designed trajectory. An orbit correction system is optimized, which balances between cost and performance of orbit after correction at design level. Different methods are used to estimate its robustness. The BBU instability, especially multi-pass BBU imposed a potentially severe limitation to the average current that can be accelerated in an ERL. Simulation gives the harmful HOMs and predicts that the threshold average current in this machine is much higher than the possible operation current. This work is based on the existing facility in PKU, so it provides guidelines for the facility operation and upgrade in the future. The theoretical analysis of ERL requirement and FEL requirement on beam transport line and beam property paves the way for future ERL research.

43 PARTICLE ACCELERATORS↗

Search for High-Mass Top Quark Pair Resonances with the CMS Experiment

I present a search for new massive particles decaying to a pair of top quarks with the CMS detector at the LHC, using 36 fb$^{-1}$ of proton-proton collision data recorded in 2016, at a center-of-mass energy of 13 TeV. In the high mass ranges accessible by the LHC at these energies, the top quarks are produced with high transverse momenta: the products of hadronically decaying top quarks are reconstructed as a single jet. Specific reconstruction algorithms and selections are employed to address the identification of boosted top quark signatures. The search is performed by measuring the invariant mass distribution of the top-quark pair and testing for deviations from the expected Standard Model background. The results are presented in terms of expected upper limits on the production cross section of several models, including those of Randall-Sundrum Kaluza-Klein gluon and $Z\prime$ boson production. The results are then compared with those of previous searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Variance Reduction for Global k-Eigenvalue Simulations in MCNP

The "criticality" or k-eigenvalue of a nuclear system determines whether the system is critical (k=1), or the extent to which it is subcritical (k<1) or supercritical (k>1). Calculations of k are frequently performed at nuclear facilities to determine the criticality of nuclear reactor cores, spent nuclear fuel storage casks, and other fissile systems. These calculations can be expensive, and current Monte Carlo methods have certain well-known deficiencies. In this project, we have developed and tested a new "functional Monte Carlo" (FMC) method that overcomes several of these deficiencies. The current state-of-the-art Monte Carlo k-eigenvalue method estimates the fission source for a sequence of fission generations (cycles), during each of which M particles per cycle are processed. After a series of "inactive" cycles during which the fission source "converges," a series of "active" cycles are performed. For each active cycle, the eigenvalue and eigenfunction are estimated; after N >> 1 active cycles are performed, the results are averaged to obtain estimates of the eigenvalue and eigenfunction and their standard deviations. This method has several disadvantages: (i) the estimate of k depends on the number M of particles per cycle, (iii) for optically thick systems, the eigenfunction estimate may not converge due to undersampling of the fission source, and (iii) since the fission source in any cycle depends on the estimated fission source from the previous cycle (the fission sources in different cycles are correlated), the estimated variance in k is smaller than the real variance. For an acceptably large number M of particles per cycle, the estimate of k is nearly independent of M; this essentially takes care of item (i). Item (ii) can be addressed by taking M sufficiently large, but for optically thick systems a sufficiently large M can easily be unrealistic. Item (iii) cannot be accounted for by taking M or N sufficiently large; it is an inherent deficiency due to the correlations between fission source estimates. In the new FMC method, the eigenvalue problem (expressed in terms of the Boltzmann equation) is integrated over the energy and direction variables. Then these equations are multiplied by J special "tent" functions in space and integrated over the spatial variable. This yields J equations that are exactly satisfied by the eigenvalue k and J space-angle-energy moments of the eigenfunction. Multiplying and dividing by suitable integrals of the eigenfunction, one obtains J algebraic equations for k and the space-angle-energy moments of the eigenfunction, which contain nonlinear functionals that depend weakly on the eigenfunction. In the FMC method, information from the standard Monte Carlo solution for each active cycle is used to estimate the functionals, and at the end of each cycle the J equations for k and the space-angle-energy moments of the eigenfunction are solved. Finally, these results are averaged over N active cycles to obtain estimated means and standard deviations for k and the space-angle-energy moments of the eigenfunction. Our limited testing shows that for large single fissile systems such as a commercial reactor core, (i) the FMC estimate of the eigenvalue is at least one order of magnitude more accurate than estimates obtained from the standard Monte Carlo approach, (ii) the FMC estimate of the eigenfunction converges and is several orders of magnitude more accurate than the standard estimate, and (iii) the FMC estimate of the standard deviation in k is at least one order of magnitude closer to the correct standard deviation than the standard estimate. These advances occur because: (i) the Monte Carlo estimates of the nonlinear functionals are much more accurate than the direct Monte Carlo estimates of the eigenfunction, (ii) the system of discrete equations that determines the FMC estimates of k is robust, and (iii) the functionals are only very weakly correlated between different fission generations. The FMC method was developed only late in the project and has to date received limited testing. Current work, which is taking place after the conclusion of this project, involves further development and testing for more complex and realistic problems. We expect that the FMC method will become a practical tool for Monte Carlo criticality simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

"Hierarchical Speed Planner for Automated Vehicles: A Framework for Lagrangian Variable Speed Limit in Mixed Autonomy Traffic"

This paper introduces a novel control framework for Lagrangian variable speed limits in hybrid traffic flow environments utilizing automated vehicles (AVs). The framework was validated using a fleet of 100 connected automated vehicles as part of the largest coordinated open-road test designed to smooth traffic flow. The framework includes two main components: a high-level controller deployed on the server side, named Speed Planner, and low-level controllers called vehicle controllers deployed on the vehicle side. The Speed Planner designs and updates target speeds for the vehicle controllers based on real-time Traffic State Estimation (TSE) [1]. The Speed Planner comprises two modules: a TSE enhancement module and a target speed design module. The TSE enhancement module is designed to minimize the effects of inherent latency in the received traffic information and to improve the spatial and temporal resolution of the input traffic data. The target speed design module generates target speed profiles with the goal of improving traffic flow. The vehicle controllers are designed to track the target speed meanwhile responding to the surrounding situation. The numerical simulation indicates the performance of the proposed method: the bottleneck throughput has increased by 5.01%, and the speed standard deviation has been reduced by a significant 34.36%. We further showcase an operational study with a description of how the controller was implemented on a field-test with 100 AVs and its comprehensive effects on the traffic flow.

Wang, Han↗

Implementation of in vivo Dosimetry with Isorad{sup TM} Semiconductor Diodes in Radiotherapy Treatments of the Pelvis

This report describes the results obtained with the Isorad{sup TM} (Red) semiconductor detectors for implementing an in vivo dosimetry program in patients subject to radiotherapy treatment of the pelvis. Four n-type semiconductor diodes were studied to characterize them for the application. The diode calibration consisted of establishing reading-to-dose conversion factors in reference conditions and a set of correction factors accounting for deviations of the diode response in comparison to that of an ion chamber. Treatments of the pelvis were performed by using an isocentric 'box' technique employing a beam of 18 MV with the shape of the fields defined by a multileaf collimator. The method of Rizzotti-Leunen was used to assess the dose at the isocenter based on measurements of the in vivo dose at the entrance and at the exit of each radiation field. The in vivo dose was evaluated for a population of 80 patients. The diodes exhibit good characteristics for their use in in vivo dosimetry; however, the high attenuation of the beam ({approx}12% at 5.0-cm depth) produced, and some important correction factors, must be taken into account. The correction factors determined, including the source-to-surface factor, were within a range of {+-}4%. The frequency histograms of the relative difference between the expected and measured doses at the entrance, the exit, and the isocenter, have mean values and standard deviations of -0.09% (2.18%), 0.77% (2.73%), and -0.11% (1.76%), respectively. The method implemented has proven to be very useful in the assessment of the in vivo dose in this kind of treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of WH and ZH production with Higgs boson decays into bottom quarks and direct constraints on the charm Yukawa coupling in 13 TeV pp collisions with the ATLAS detector

A study of the Higgs boson decaying into bottom quarks (H → $b\bar{b}$) and charm quarks (H → $c\bar{c}$) is performed, in the associated production channel of the Higgs boson with a W or Z boson, using 140 fb −1 of proton-proton collision data at $\sqrt{s}$ = 13 TeV collected by the ATLAS detector. The individual production of WH and ZH with H → $b\bar{b}$ is established with observed (expected) significances of 5.3 (5.5) and 4.9 (5.6) standard deviations, respectively. Differential cross-section measurements of the gauge boson transverse momentum within the simplified template cross-section framework are performed in a total of 13 kinematical fiducial regions.

Hadron-Hadron Scattering↗

Aperture modulated, translating bed total body irradiation

Purpose: Total body irradiation (TBI) techniques aim to deliver a uniform radiation dose to a patient with an irregular body contour and a heterogeneous density distribution to within {+-}10% of the prescribed dose. In the current article, the authors present a novel, aperture modulated, translating bed TBI (AMTBI) technique that produces a high degree of dose uniformity throughout the entire patient. Methods: The radiation beam is dynamically shaped in two dimensions using a multileaf collimator (MLC). The irregular surface compensation algorithm in the Eclipse treatment planning system is used for fluence optimization, which is performed based on penetration depth and internal inhomogeneities. Two optimal fluence maps (AP and PA) are generated and beam apertures are created to deliver these optimal fluences. During treatment, the patient/phantom is translated on a motorized bed close to the floor (source to bed distance: 204.5 cm) under a stationary radiation beam with 0 deg. gantry angle. The bed motion and dynamic beam apertures are synchronized. Results: The AMTBI technique produces a more homogeneous dose distribution than fixed open beam translating bed TBI. In phantom studies, the dose deviation along the midline is reduced from 10% to less than 5% of the prescribed dose in the longitudinal direction. Dose to the lung is reduced by more than 15% compared to the unshielded fixed open beam technique. At the lateral body edges, the dose received from the open beam technique was 20% higher than that prescribed at umbilicus midplane. With AMTBI the dose deviation in this same region is reduced to less than 3% of the prescribed dose. Validation of the technique was performed using thermoluminescent dosimeters in a Rando phantom. Agreement between calculation and measurement was better than 3% in all cases. Conclusions: A novel, translating bed, aperture modulated TBI technique that employs dynamically shaped MLC defined beams is shown to improve dose uniformity in three dimensions. In comparison with the fixed open beam TBI technique, homogeneity of dose distribution is greatly improved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Q{sub weak} experiment update and applications/opportunities at lower energies

The Q{sub weak} experiment has recently completed data-taking at Jefferson Lab. The primary focus of the experiment is to perform a precision measurement of the proton's neutral weak charge. The Standard Model gives a definite prediction for the weak charge. Any deviation from that can be interpreted as evidence for new physics beyond the Standard Model. This precision, low energy measurement is sensitive to new physics signatures at energy scales up to 2 TeV. The experiment measures the parity-violating asymmetry in the scattering of 1.165 GeV longitudinally polarized electrons on the proton at low momentum transfer (Q{sup 2} ∼ 0.025 (GeV/c){sup 2}). This paper provides a brief status report on the experiment with a focus on instrumentation and techniques that are applicable to lower beam energy realizations of parity-violating electron scattering measurements. Estimates of anticipated errors on the proton's weak charge expected if the Q{sub weak} apparatus were used at a lower beam energy are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing gravity using galaxy clusters: new constraints on beyond Horndeski theories

The Beyond Horndeski class of alternative gravity theories allow for Self-accelerating de-Sitter cosmologies with no need for a cosmological constant. This makes them viable alternatives to ΛCDM and so testing their small-scale predictions against General Relativity is of paramount importance. These theories generically predict deviations in both the Newtonian force law and the gravitational lensing of light inside extended objects. Therefore, by simultaneously fitting the X-ray and lensing profiles of galaxy clusters new constraints can be obtained. In this work, we apply this methodology to the stacked profiles of 58 high-redshift (0.1 < z < 1.2) clusters using X-ray surface brightness profiles from the XMM Cluster Survey and weak lensing profiles from CFHTLenS. By performing a multi-parameter Markov chain Monte Carlo analysis, we are able to place new constraints on the parameters governing deviations from Newton's law Υ{sub 1} = −0.11{sup +0.93}{sub −0.67} and light bending Υ{sub 2} = −0.22{sup +1.22}{sub −1.19}. Both constraints are consistent with General Relativity, for which Υ{sub 1} = Υ{sub 2} = 0. We present here the first observational constraints on Υ{sub 2}, as well as the first extragalactic measurement of both parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning Driven Contouring of High-Frequency Four-Dimensional Cardiac Ultrasound Data

Automatic boundary detection of 4D ultrasound (4DUS) cardiac data is a promising yet challenging application at the intersection of machine learning and medicine. Using recently developed murine 4DUS cardiac imaging data, we demonstrate here a set of three machine learning models that predict left ventricular wall kinematics along both the endo- and epi-cardial boundaries. Each model is fundamentally built on three key features: (1) the projection of raw US data to a lower dimensional subspace, (2) a smoothing spline basis across time, and (3) a strategic parameterization of the left ventricular boundaries. Model 1 is constructed such that boundary predictions are based on individual short-axis images, regardless of their relative position in the ventricle. Model 2 simultaneously incorporates parallel short-axis image data into their predictions. Model 3 builds on the multi-slice approach of model 2, but assists predictions with a single ground-truth position at end-diastole. To assess the performance of each model, Monte Carlo cross validation was used to assess the performance of each model on unseen data. For predicting the radial distance of the endocardium, models 1, 2, and 3 yielded average R2 values of 0.41, 0.49, and 0.71, respectively. Monte Carlo simulations of the endocardial wall showed significantly closer predictions when using model 2 versus model 1 at a rate of 48.67%, and using model 3 versus model 2 at a rate of 83.50%. These finding suggest that a machine learning approach where multi-slice data are simultaneously used as input and predictions are aided by a single user input yields the most robust performance. Subsequently, we explore the how metrics of cardiac kinematics compare between ground-truth contours and predicted boundaries. We observed negligible deviations from ground-truth when using predicted boundaries alone, except in the case of early diastolic strain rate, providing confidence for the use of such machine learning models for rapid and reliable assessments of murine cardiac function. To our knowledge, this is the first application of machine learning to murine left ventricular 4DUS data. Future work will be needed to strengthen both model performance and applicability to different cardiac disease models.

4D ultrasound↗

HPC4Mfg with Samsung: Making semiconductor devices cool through HPC ab initio simulations

For decades, the semiconductor technology has followed the Moore’s law, making newer devices more powerful and energy efficient. Recently, however, it has reached a point where the performance and the energy efficiency of the device do not improve with the shrinking device size. One of the fundamental reasons of this deviation from the past trend is the interconnect resistance, which becomes larger with the shrinking size. The devices size is so small that the quantum mechanical effects can no longer be ignored and the traditional continuum simulation tools such as TCAD become inadequate. In this project, Samsung Semiconductor Inc. and Lawrence Berkeley National Laboratory has collaborated to perform first of kind device-scale ab initio simulations to optimize materials and interconnect morphology to minimize interconnect resistance. We have tested the use of LS3DF method and the PEtot_trans approach on top of the folded spectrum method (FSM) Escan code to calculate the scattering state, and to study various effects influence the interconnect conductivity. We found that, the LS3DF can be used to calculate such metallic system. On the other hand, the use of Escan code to solve the linear equation is not practical due to the slow convergence. We have implemented a Chebyshev filter technique to calculate a few hundred eigen states near the scattering state energy E, then use these eigen states as preconditioner to solve the linear equation. We have used this approach to study the different factors which affect the interconnect conductivity, including the shape, the point defect, the temperature, and the grain boundary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An extensive assessment of the performance of pairwise and many-body interaction potentials in reproducing ab initio benchmark binding energies for water clusters n = 2–25

We assess the performance of 7 pairwise additive (TIP3P, TIP4P, TIP4P-ice, TIP5P, OPC, SPC, SPC/E) and 8 families of many-body potentials (q-AQUA, HIPPO, AMOEBA, EFP, TTM, WHBB, MB-pol, MB-UCB) in reproducing high-level ab initio benchmark values, CCSD(T) or MP2 at the complete basis set (CBS) limit for the binding energy and the many-body expansion (MBE) of water clusters n = 2–11, 16–17, 20, 25. By including a large range of cluster sizes having dissimilar hydrogen bonding networks, we obtain an understanding of how these potentials perform for different hydrogen bonding arrangements that are mostly outside of their parameterization range. While it is appropriate to compare the results of ab initio based many-body potentials directly to the electronic binding energies (D e 's), the pairwise additive ones are compared to the enthalpies at T = 298 K, ΔH(298 K), as the latter class of force fields are parametrized to reproduce enthalpies (implicitly accounting for zero-point energy corrections) rather than binding energies. We find that all pairwise additive potentials considered overestimate the reference ΔH values for the n = 2–25 clusters by >13%. For the water dimer (n = 2) in particular, the errors are in the range 83–119% for the pairwise additive potentials studied since these are based on an effective rather than the true 2-body interaction specifically designed as a means of partially accounting for the missing many-body terms. This stronger 2-body interaction is achieved by an enhanced monomer dipole moment that mimics its increase from the gas phase monomer to the condensed phase value. Indeed, for cluster sizes n ≥ 4 the percent deviations become slightly smaller (albeit all exceeding 13%). In contrast, we find that the many-body potentials perform more accurately in reproducing the electronic binding energies (D e 's) throughout the entire cluster range (n = 2–25), all reproducing the ab initio benchmark binding energies within ±7% of the respective CBS values. We further assess the ability of a subset of the many-body potentials (MB-UCB, q-AQUA, MB-pol, and TTM2.1-F) to also reproduce the magnitude of the ab initio many-body energy terms for water cluster sizes n = 7, 10, 16 and 17. The potentials show an overall good agreement with the available benchmark values. However, we identify characteristic differences upon comparing the many-body terms at both the ab initio-optimized geometries and the respective potential-optimized geometries to the reference ab initio values. Additionally, by applying this analysis to a wide range of cluster sizes, trends in the MBE of the potentials with increasing cluster size can be identified. Finally, in an attempt to draw a parallel between the pairwise additive and many-body potentials, we report the analysis of the individual molecular dipole moments for water clusters with 1 to ~4 solvation shells with the TTM2.1-F potential. We find that the internally solvated water molecules have in general a larger molecular dipole moment ranging from 2.6–3.0 D. This justifies the use of an enhanced, with respect to the gas-phase value, molecular dipole moment for the pairwise additive potentials, which is intended to fold in the many body terms into an effective (enhanced) pairwise interaction through the choice of the charges. These results have important implications for the development of future generations of efficient, transferable, and highly accurate classical interaction potentials in both the pairwise additive and many-body categories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗