Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase Changing Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Tunable phase-change metasurfaces coupled with mid-infrared molecular vibrations

Chiral optical metasurfaces have emerged as a promising platform in coupling with molecular vibrational fingerprints through the enhanced light-matter interaction under different circularly polarized light illumination. Here, this work reports the mode coupling between the mid-infrared phonon vibrations of polymethyl methacrylate (PMMA) molecules and the thermally tunable chiral metasurfaces based on the phase-change material Ge₂Sb₂Te₅ (GST-225). Phase-change chiral metasurfaces with high circular dichroism (CD) in absorption and tunable plasmonic resonance in the frequency range of 48–56 THz are demonstrated, which covers the phonon vibrational frequency of PMMA molecules at 52 THz. The mode splitting features are observed in the absorption and CD spectra when the metasurface resonance is tuned across the phonon vibrational frequency of PMMA molecules during the phase transition of GST-225. The underlying mechanism of molecule-metasurface coupling is further revealed by studying the electric field and power loss density distributions of the phonon–plasmon coupled modes under both left-handed and right-handed circularly polarized (LCP and RCP) light. The demonstrated results show the potential of dynamically tunable chiral metasurfaces for the applications in label-free molecular sensing, biomedical diagnostics, thermal imaging, and mid-infrared photonics.

Tang, Haotian [Missouri Univ. of Science and Techn↗

Generation and the role of dislocations in single-crystalline phase-change In 2 Se 3 nanowires under electrical pulses

Using single crystalline In2Se3 nanowires as a platform, we have studied the RESET switching (from low to high electrical resistance) in this phase-change material under electric pulses. Particularly, we correlated the atomic-scale structural evolutions with local electrical resistance variations, by performing transmission electron microscopy and scanning Kelvin probe microscopy on the same nanowires. By coupling the experimental results with density functional theory calculations, we show that the immobile dislocations generated via vacancy condensations are responsible for the RESET switching and that the material maintains the single crystallinity during the process. This new mechanism is fundamentally different from the crystalline-amorphous transition, which is commonly understood as the underlying process for the RESET switching in similar phase-change materials.

Environmental Molecular Sciences Laboratory↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Unusual crystallization behavior in Ga-Sb phase change alloys

Combined in situ X-ray scattering techniques using synchrotron radiation were applied to investigate the crystallization behavior of Sb-rich Ga-Sb alloys. Measurements of the sheet resistance during heating indicated a reduced crystallization temperature with increased Sb content, which was confirmed by in situ X-ray diffraction. The electrical contrast increased with increasing Sb content and the resistivities in both the amorphous and crystalline phases decreased. It was found that by tuning the composition between Ga:Sb = 9:91 (in at.%) and Ga:Sb = 45:55, the change in mass density upon crystallization changes from an increase in mass density which is typical for most phase change materials to a decrease in mass density. At the composition of Ga:Sb = 30:70, no mass density change is observed which should be very beneficial for phase change random access memory (PCRAM) applications where a change in mass density during cycling is assumed to cause void formation and PCRAM device failure.

36 MATERIALS SCIENCE↗

Stasis PCM Test Results

A phase change material product distributed by Stasis Group, designed to reduce the cooling energy requirements of multi-story commercial buildings, was tested in a side-by-side comparison at FLEXLAB® (LBNL, 2018), a calibrated test facility for low energy building technology solutions. The product was installed according to Stasis recommendations in the ceiling plenum of a 600 ft 2 cell representative of an office space, while an identical cell was operated in the same conditions, except for the night-time pre-cooling sequence and without the product, to gather baseline data. The cells were operated to replicate summer conditions of a candidate office building for retrofit. For the tests conducted at FLEXLAB, two Phase Change Material (PCM) compositions were tested, with the second product having an upgraded composition for thermal performance and upgraded packaging that was used to meet with fire safety requirements for a plenum application. Two rounds of tests were performed, which were designed to collect data for both core (designated as Round 1) and perimeter (Round 2) office space conditions. Following the analysis of the data collected during Round 1, the experimental design was modified to better represent the thermal conditions of a typical office space in relation to the PCM performance. A new product was also brought in for testing in Round 2, which had an improved operational temperature range and packaging properties. In Round 1, multiple tests were conducted to evaluate the performance of the product under different conditions of internal loads, temperature setpoints, pre-cooling strategies and temperature control strategies. In Round 2, the internal conditions were kept constant, while the test conditions only differ in the amount of PCM installed in the test cell plenum and the length of the nighttime pre-cooling sequence. The performance benefits of PCM are generally two-fold: the material may reduce peak cooling energy use during daytime hours (a peak demand energy use benefit) and may allow for energy savings with pre-cooling at night through night flush HVAC controls when night time outside air temperatures are lower, and fan energy use for cooling is more efficient than the use of daytime compressor-based cooling. The focus of this research project was mainly on quantifying the energy savings potential of the latter case although some effects on peak reduction were noted. Between the cell with PCM and nighttime precooling and the reference cell without PCM or precooling, a reduction in cooling load during occupied hours was noted between 7.6 kWh (or 22% of occupied hours cooling load) and 12.5 kWh (or 33% of occupied pg. 7 hours cooling load). Future work can further evaluate the peak cooling load reduction benefits of this product in more detail. This report highlights the results of Round 2, which reflect the performance of the modified PCM product when operated in suitable conditions. The results of Round 1, along with an analysis of the experimental data to identify the factors that prevented the product from performing as desired are presented in Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ab initio study of molecular and atomic oxygen on GeTe(111) surfaces

Oxidation of the phase-change material germanium telluride (GeTe) is an atomic-scale process of fundamental importance, as it is detrimental to the stability of GeTe-based data-storage devices. Here, we present comprehensive density-functional theory simulations of molecular and atomic oxygen in contact with GeTe(111) surfaces. Molecular O{sub 2} is predicted to readily adsorb on the Ge-terminated (111) surface; the pristine Te-terminated counterpart, by contrast, appears quite inert. The coverage-dependent adsorption of O atoms is then investigated, and based on these data, a surface phase diagram for GeTe(111)/O is constructed. These results afford a detailed, atom-resolved picture of the initial surface oxidation of GeTe, and they harmonize well with a previous X-ray photoelectron spectroscopy study on this very topic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronic structure of (Ge{sub 2}Sb{sub 2}Te{sub 5}){sub 1-x}(In{sub 3}SbTe{sub 2}){sub x} investigated by x-ray photoelectron spectroscopy

We have investigated the core levels and the valence band of (Ge{sub 2}Sb{sub 2}Te{sub 5}){sub 1-x}(In{sub 3}Sb{sub 1}Te{sub 2}){sub x} quaternary phase system (IGST) by means of x-ray photoelectron spectroscopy. A systematic shift of Sb 3d and Ge 2p core-level peaks toward lower binding energies side was observed with increasing indium amount, whereas the In 3d and Te 3d core peaks showed less change. The Sb 3d and Ge 2p core-level shift is attributed to an increase in the electronic charge of p-electrons dependent of indium amount. The valence band spectra show a distinct change in the sp configuration with indium concentration change. The change in the local bonding as the indium amount increase has a profound impact on both local atomic arrangement and amorphous-to-crystalline transformation temperature. The difference in the photoemission spectra have been discussed according to a simple structural model suggesting that the Na site in IGST can be occupied by Te, Sb, In, and vacancy, whereas in GST it is occupied only by Te.

36 MATERIALS SCIENCE↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Study on the nitrogen-doped W-Sb-Te material for phase change memory application

N doping is proposed to enlarge sensing margin of W{sub 0.08}(Sb{sub 2}Te){sub 0.92} based high-temperature phase-change memories (PCMs). The sensing margin is increased from 30 to 5 × 10{sup 3}, with an increase from 145 °C to 158 °C in data retention. The grain size is reduced to 10 nm. The PCM based on N-W{sub 0.08}(Sb{sub 2}Te){sub 0.92} shows the fast operation speed of 30 ns and good cycling ability of >10{sup 3}. By X-ray photoelectron spectroscopy and ab initio calculation, the W atoms are suggested to locate in the Sb positions and interstices of the lattice. The W atoms in interstice will bond to N atoms during N doping.

36 MATERIALS SCIENCE↗

Evolution of short- and medium-range order in the melt-quenching amorphization of Ge 2 Sb 2 Te 5

Phase-change memory takes advantage of the fast phase transition between amorphous and crystalline phases of phase-change materials (e.g.,Ge 2 Sb 2 Te 5 or GST). To date, while the “SET” process (crystallization of GST glass) has been intensively studied, studies on the “RESET” process (melt-quenching amorphization of GST) are still limited. Here, we explore the structural changes of GST upon rapid cooling by ab initio molecular dynamics simulations and atomistic cluster alignment (ACA) analysis. Different from other methods which only focus on the nearest bonding atoms, the ACA method can study both the short- and medium-range order clusters containing atoms beyond the first-neighboring shell and enables us to explore the changes of cluster structures in a larger scale. The results reveal that low-coordinated octahedral clusters tend to become high-coordinated ones, and Ge-centered octahedral structures change to tetrahedrons whereas Sb-centered tetrahedrons transform to octahedral structures during the amorphization process. Interestingly, tetrahedrons show aggregation in liquid and supercooled liquid in contrast to 6-fold octahedrons which present notable aggregation in amorphous GST. Furthermore, our study showed that wrong bonds (Ge–Ge, Sb–Sb, Ge–Sb and Te–Te bonds) can promote the formation of large rings, and irreducible rings tend to separate into smaller and larger rings as the temperature is decreased. Our conclusions provide useful insights into the formation process and the structure of amorphous GST, which is valuable for facilitating the application of phase change materials.

36 MATERIALS SCIENCE↗

Numerical investigation of thermal runaway mitigation through a passive thermal management system

Prevention of thermal runaway and its propagation remains a technical barrier to the application of lithium-ion batteries. To mitigate thermal runaway in lithium-ion battery packs, heat sinks have been designed using various materials, such as phase-change materials or metal plates. In this study, aluminum plates were assembled into battery modules as heat sinks and the effect of plate thickness on thermal runaway mitigation was numerically investigated. A three-dimensional integrated multiphysics model was validated and calibrated with experimental data. It identified the mechanism and sequence of thermal runaway propagation in detail. Thermal mass and contact resistance are found to be the key design parameters for preventing thermal runaway propagation for the studied battery module configuration. In addition, this study provides further insights into the design of aluminum heat sinks for lithium-ion battery packs.

25 ENERGY STORAGE↗

High thermal stability Sb{sub 3}Te-TiN{sub 2} material for phase change memory application

For phase change memory (PCM) applications, it has been widely accepted that δ phase Sb-Te has fast operation speed and good phase stability. However, the fast growth crystallization mechanism will cause poor amorphous phase stability and overlarge grain size. We introduce TiN{sub 2} into δ phase Sb-Te (Sb{sub 3}Te) to enhance the amorphous thermal stability and refine the grain size. With TiN{sub 2} incorporating, the temperature for 10-year data retention increases from 79 °C to 124 °C. And the grain size decreases to dozens of nanometers scale. Based on X-ray photoelectron spectroscopy and transmission electron microscopy results, we knew that nitrogen atoms bond with titanium, forming disorder region at the grain boundary of Sb{sub 3}Te-TiN{sub 2} (STTN). Thus, STTN has a quite different crystallization mechanism from Sb{sub 3}Te. Furthermore, PCM device based on STTN can realize reversible phase change under 20 ns electrical pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spacesuit Materials Add Comfort to Undergarments

Phase change materials (PCMs) were one of the technologies NASA used to help astronauts maintain a "just right" temperature in their space gloves. To incorporate PCMs in spacesuit fabrics, Johnson Space Center collaborated with Outlast Technologies Inc. In 2011, Jockey International, headquartered in Kenosha, Wisconsin, released a line of men's and women's undergarments incorporating the NASA technology

Source record↗

Observation and modeling of polycrystalline grain formation in Ge{sub 2}Sb{sub 2}Te{sub 5}

The relationship between the polycrystalline nature of phase change materials (such as Ge{sub 2}Sb{sub 2}Te{sub 5}) and the intermediate resistance states of phase change memory (PCM) devices has not been widely studied. A full understanding of such states will require knowledge of how polycrystalline grains form, how they interact with each other at various temperatures, and how the differing electrical (and thermal) characteristics within the grains and at their boundaries combine through percolation to produce the externally observed electrical (and thermal) characteristics of a PCM device. We address the first of these tasks (and introduce a vehicle for the second) by studying the formation of fcc polycrystalline grains from the as-deposited amorphous state in undoped Ge{sub 2}Sb{sub 2}Te{sub 5}. We perform ex situ transmission electron microscopy membrane experiments and then match these observations against numerical simulation. Ramped-anneal experiments show that the temperature ramp-rate strongly influences the median grain size. By truncating such ramped-anneal experiments at various peak temperatures, we convincingly demonstrate that the temperature range over which these grains are established is quite narrow. Subsequent annealing at elevated temperature appears to change these established distributions of grain sizes only slightly. Our numerical simulator--which models nuclei formation through classical nucleation theory and then tracks the subsequent time- and temperature-dependent growth of these grains--can match these experimental observations of initial grain distributions and crystallization temperature both qualitatively and quantitatively. These simulations show that the particular narrow temperature range over which crystallization occurs shifts as a function of temperature ramp-rate, which allows us to quantify the lower portions of the time-temperature-transformation map for Ge{sub 2}Sb{sub 2}Te{sub 5}. Future experiments and extensions of the simulator to investigate temperature-dependent interactions between neighboring grains, and to study nucleation from within the melt-quenched amorphous state, are discussed.

36 MATERIALS SCIENCE↗

Manufacturing of Continuous Core–Shell Hydrated Salt Fibers for Room Temperature Thermal Energy Storage

The encapsulation of salt hydrate phase change materials (PCMs) in uniform microscale bodies has yet been reported in research due in part to the delicate relationship between thermal performance and water-to-salt ratios which are easily altered during manufacturing. Herein, core–shell composite fibers comprised of a salt hydrate PCM core and a poly(acrylonitrile) (PAN) shell are wet spun in a continuous process using a syringe pump and coaxial die. The PCM phase comprises calcium chloride hexahydrate (CaCl 2 ·6H 2 O) with strontium chloride hexahydrate(SrCl 2 ·6H 2 O) (3 wt%) and fumed silica(SiO 2 ) (2 wt%) as additive, a composition that is prepared from homogenous melt at 40 °C. 15 wt% PAN in dimethylsulfoxide solvent is used to prepare the shell-forming polymer gel. PCM and polymer gel injection rates of 10–40 mL h –1 are used to spin coaxial fibers through a coagulation bath, yielding continuous microtubules with diameters in the range of 850–1500 μm. Cyclic testing shows that after 1000 cycles, melting enthalpies incurred only a 3.5% decline from 131.46 to 126.9 J g –1 . In conclusion, success here overcomes several coincidental drawbacks of PCM fiber performance and manufacturing and delivers the first example of scalable roll-to-roll PCM fiber produced by wet spinning for building material applications.

36 MATERIALS SCIENCE↗