Search NASA⌕ Search

SEARCH · Search NASA

Results for “Point Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Impact of point source clustering on cosmological parameters with CMB anisotropies

The faint radio point sources that are unresolved in cosmic microwave background (CMB) anisotropy maps are likely to be a biased tracer of the large-scale structure dark matter distribution. While the shot-noise contribution to the angular power spectrum of unresolved radio point sources is included either when optimally constructing the CMB angular power spectrum, as with WMAP data, or when extracting cosmological parameters, we suggest that clustering part of the point source power spectrum should also be included. This is especially necessary at high frequencies above 150 GHz, where the clustering of far-IR sources is expected to dominate the shot-noise level of the angular power spectrum at tens of arcminute angular scales of both radio and sub-mm sources. We make an estimate of source clustering of unresolved radio sources in both WMAP and ACBAR, and marginalize over the amplitude of source clustering in each CMB data set when model fitting for cosmological parameters. For the combination of WMAP 5-year data and ACBAR, we find that the spectral index changes from the value of 0.963{+-}0.014 to 0.959{+-}0.014 (at 68% C.L.) when the clustering power spectrum of point sources is included in model fits. While we find that the differences are marginal with and without source clustering in current data, it may be necessary to account for source clustering with future data sets such as Planck, especially to properly model fit anisotropies at arcminute angular scales. If clustering is not accounted and point sources are modeled with a shot noise only out to l{approx}2000, the spectral index will be biased by about 1.5{sigma}.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving the cross correlation method of indirect flow measurement by water injection and modeling - 245

This paper presents a technique to improve the Cross Correlation Function (CCF) method for indirect flow measurement. Unlike other methods, the CCF method does not need a specific instrument or tool for flow measurements. Instead, the delay time between two sensors can be derived by applying the CCF. A water flow loop was constructed to investigate the CCF method for flow measurement. Because the inherent process temperature variations were small when compared to significant amounts of measurement and process noise, inaccurate flow measurements were obtained. The performance of the CCF method could be improved by increasing the system signal-to-noise ratio, which is the process noise divided by the measurement noise. For this reason, a periodic injection of different temperature water was used to increase the process temperature variation. The results were favorable. However, several design variables needed to be selected. To assist, a CFD simulation was utilized to optimize the distance between sensors and injection point, the rate of injection flow, and other related variables. The results show that CCF optimization of these variables produces better flow measurement performance over a range of flow velocities. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum power point tracking for a multi-layered piezoelectric heel charger with a levered mechanism toward impact-based energy harvesting

The piezoelectric footstep energy harvester does not always work at its maximum power point when the external load is fixed, as the optimal load changes when the walking excitation alters. Thus, the harvesting efficiency is downgraded largely in real-life scenarios compared to in-lab experiments and theoretical or numerical predictions due to the mismatch between the actual load and the optimal load. To address this issue, the concept of Maximum Power Point Tracking (MPPT) is investigated in this paper and the circuit design is implemented for a multi-layered levered piezoelectric footstep energy harvester (heel charger). The proposed event-driven MPPT circuit interface with a customized buck converter aims to maximize the power gained from daily walking using the heel charger to power a fixed load, such as smart insole or shoes. The MPPT circuit design is conceptually simulated and then tested with the heel charger to further validate if it works at its maximum power point when the frequency of the input excitation alters. Results show that the extracted power from the heel charger connected to a fixed resistance load with MPPT implementation is improved up to 300% compared to the one without MPPT implementation in simulation and up to 180% in the experiment when connected to a fixed load. The difference between simulation and experimental results is due to the optimization of using voltage sources as the heel charger and the control signals (pulse width modulation) from the microcontroller in the simulation.

47 OTHER INSTRUMENTATION↗

Optimization of Periodic Composite Structures for Sub-Wavelength Focusing

Recently, there has been plenty of work in designing and fabricating materials with an effective negative refractive index. Veselago realized that a slab of material with a refractive index of -1 would act as a lens. Pendry suggested that the Veselago lens would act as a superlens, providing a perfect image of an object in contrast to conventional lenses which are only able to focus a point source to an image having a diameter of the order of the wavelength of the incident field.Recent work has shown that similar focusing effects can be obtained with certain slabs of 'conventional' periodic composite materials: photonic crystals. The present work seeks to answer the question of what periodic dielectric composite medium (described by dielectric coefficient with positive real part) gives an optimal image of a point source. An optimization problem is formulated and it is shown that a solution exists provided the medium has small absorption. Solutions are characterized by an adjoint-state gradient condition, and several numerical examples illustrate both the plausibility of this design approach, and the possibility of obtaining smaller image spot sizes than with typical photonic crystals.

97 MATHEMATICS AND COMPUTING↗

Optimization and Multimachine Learning Algorithms to Predict Nanometal Surface Area Transfer Parameters for Gold and Silver Nanoparticles

Interactions between gold metallic nanoparticles and molecular dyes have been well described by the nanometal surface energy transfer (NSET) mechanism. However, the expansion and testing of this model for nanoparticles of different metal composition is needed to develop a greater variety of nanosensors for medical and commercial applications. In this study, the NSET formula was slightly modified in the size-dependent dampening constant and skin depth terms to allow for modeling of different metals as well as testing the quenching effects created by variously sized gold, silver, copper, and platinum nanoparticles. Overall, the metal nanoparticles followed more closely the NSET prediction than for Förster resonance energy transfer, though scattering effects began to occur at 20 nm in the nanoparticle diameter. To further improve the NSET theoretical equation, an attempt was made to set a best-fit line of the NSET theoretical equation curve onto the Au and Ag data points. An exhaustive grid search optimizer was applied in the ranges for two variables, 0.1≤C≤2.0 and 0≤α≤4, representing the metal dampening constant and the orientation of donor to the metal surface, respectively. Three different grid searches, starting from coarse (entire range) to finer (narrower range), resulted in more than one million total calculations with values C=2.0 and α=0.0736. The results improved the calculation, but further analysis needed to be conducted in order to find any additional missing physics. With that motivation, two artificial intelligence/machine learning (AI/ML) algorithms, multilayer perception and least absolute shrinkage and selection operator regression, gave a correlation coefficient, R2, greater than 0.97, indicating that the small dataset was not overfitting and was method-independent. This analysis indicates that an investigation is warranted to focus on deeper physics informed machine learning for the NSET equations.

Demers, Steven M. E. (ORCID:0000000192213246)↗

Four-Dimensional Intensity-Modulated Radiotherapy Planning for Dynamic Multileaf Collimator Tracking Radiotherapy

Purpose: To develop a four-dimensional intensity-modulated radiotherapy (IMRT) planning method for dynamic multileaf collimator (DMLC)-based tumor tracking that takes respiratory motion into consideration. Methods and Materials: Using the concept of optimal deformation, a series of apertures are placed at different phases in the same segment to ensure maximally similar dose contributions at various anatomic points. We used a direct aperture optimization method to find a set of segments that achieved an optimal dose distribution for aperture shapes at the reference phase and achieved corresponding optimal deformations at other phases that took respiratory motion into consideration. In our four-dimensional direct aperture optimization (4D-DAO) method, a simulated annealing algorithm and a conjugate gradients algorithm were used to optimize the shape of the segments and the monitor units, respectively. We then compared the optimization results for three-dimensional conformal radiotherapy and 4D-DAO based on a set of simulated respiration 4D computed tomography (4DCT) data and a set of real 4DCT data. Results: Dosimetric analysis indicated that, compared with the 3DCRT method, the dose distribution is significantly improved when the optimal deformation tracking technique is used, even when the maximum velocity limit of the DMLC leaves is set. Conclusions: The proposed 4D-IMRT planning method can find a set of segments and the corresponding leaf movements, which can trace the tumor motion and thus protect more normal tissue from radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iron-chalcogenide FeSe(0.5)Te(0.5) Coated Superconducting Tapes for High Field Applications

The high upper critical field characteristic of the recently discovered iron-based superconducting chalcogenides opens the possibility of developing a new type of non-oxide high-field superconducting wires. In this work, we utilize a buffered metal template on which we grow a textured FeSe{sub 0.5}Te{sub 0.5} layer, an approach developed originally for high temperature superconducting coated conductors. These tapes carry high critical current densities (> 1 x 10{sup 4} A/cm{sup 2}) at about 4.2 K under magnetic field as high as 25 T, which are nearly isotropic to the field direction. This demonstrates a very promising future for iron chalcogenides for high field applications at liquid helium temperatures. Flux pinning force analysis indicates a point defect pinning mechanism, creating prospects for a straightforward approach to conductor optimization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-193: Feasibility of MRI-Only Based IMRT Planning for Pancreatic Cancer

Purpose: With the increasing use of MRI simulation and the advent of MRI-guided delivery, it is desirable to use MRI only for treatment planning. In this study, we assess the dosimetric difference between MRI- and CTbased IMRT planning for pancreatic cancer. Methods: Planning CTs and MRIs acquired for a representative pancreatic cancer patient were used. MRI-based planning utilized forced relative electron density (rED) assignment of organ specific values from IRCU report 46, where rED = 1.029 for PTV and a rED = 1.036 for non-specified tissue (NST). Six IMRT plans were generated with clinical dose-volume (DV) constraints using a research Monaco planning system employing Monte Carlo dose calculation with optional perpendicular magnetic field (MF) of 1.5T. The following five plans were generated and compared with the planning CT: 1.) CT plan with MF and dose recalculation without optimization; 2.) MRI (T2) plan with target and OARs redrawn based on MRI, forced rED, no MF, and recalculation without optimization; 3.) Similar as in 2 but with MF; 4.) MRI plan with MF but without optimization; and 5.) Similar as in 4 but with optimization. Results: Generally, noticeable differences in PTV point doses and DV parameters (DVPs) between the CT-and MRI-based plans with and without the MF were observed. These differences between the optimized plans were generally small, mostly within 2%. Larger differences were observed in point doses and mean doses for certain OARs between the CT and MRI plan, mostly due to differences between image acquisition times. Conclusion: MRI only based IMRT planning for pancreatic cancer is feasible. The differences observed between the optimized CT and MRI plans with or without the MF were practically negligible if excluding the differences between MRI and CT defined structures.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-10: Scanning Proton Arc Therapy (SPArc) - The First Robust and Delivery-Efficient Spot Scanning Proton Arc Therapy

Purpose: To develop a delivery-efficient proton spot-scanning arc therapy technique with robust plan quality. Methods: We developed a Scanning Proton Arc(SPArc) optimization algorithm integrated with (1)Control point re-sampling by splitting control point into adjacent sub-control points; (2)Energy layer re-distribution by assigning the original energy layers to the new sub-control points; (3)Energy layer filtration by deleting low MU weighting energy layers; (4)Energy layer re-sampling by sampling additional layers to ensure the optimal solution. A bilateral head and neck oropharynx case and a non-mobile lung target case were tested. Plan quality and total estimated delivery time were compared to original robust optimized multi-field step-and-shoot arc plan without SPArc optimization (Arcmulti-field) and standard robust optimized Intensity Modulated Proton Therapy(IMPT) plans. Dose-Volume-Histograms (DVH) of target and Organ-at-Risks (OARs) were analyzed along with all worst case scenarios. Total delivery time was calculated based on the assumption of a 360 degree gantry room with 1 RPM rotation speed, 2ms spot switching time, beam current 1nA, minimum spot weighting 0.01 MU, energy-layer-switching-time (ELST) from 0.5 to 4s. Results: Compared to IMPT, SPArc delivered less integral dose(−14% lung and −8% oropharynx). For lung case, SPArc reduced 60% of skin max dose, 35% of rib max dose and 15% of lung mean dose. Conformity Index is improved from 7.6(IMPT) to 4.0(SPArc). Compared to Arcmulti-field, SPArc reduced number of energy layers by 61%(276 layers in lung) and 80%(1008 layers in oropharynx) while kept the same robust plan quality. With ELST from 0.5s to 4s, it reduced 55%–60% of Arcmulti-field delivery time for the lung case and 56%–67% for the oropharynx case. Conclusion: SPArc is the first robust and delivery-efficient proton spot-scanning arc therapy technique which could be implemented in routine clinic. For modern proton machine with ELST close to 0.5s, SPArc would be a popular treatment option for both single and multi-room center.

60 APPLIED LIFE SCIENCES↗

Riemannian Optimization Applied to AC Optimal Power Flow

The nonlinear, nonconvex AC optimal power flow problem is of growing importance as the nature of the power grid evolves. This problem can be difficult to solve for interior point methods. However, the advent of optimization algorithms over smooth Riemannian manifolds presents an alternative approach. The nonlinear, nonconvex constraints in the AC power flow problem form an embedded submanifold of Euclidean space. In this paper, the authors explore the performance of Riemannian optimization algorithms for the ACOPF problem where the optimization is performed directly on the AC power flow manifold. This is done by using the Julia programming language and the Julia packages PowerModels.jl and Manopt.jl.

AC optimal power flow↗

Beyond the Coulson–Fischer point: characterizing single excitation CI and TDDFT for excited states in single bond dissociations

Linear response time dependent density functional theory (TDDFT), which builds upon configuration interaction singles (CIS) and TD-Hartree–Fock (TDHF), is the most widely used class of excited state quantum chemistry methods and is often employed to study photochemical processes. This paper studies the behavior of the resulting excited state potential energy surfaces beyond the Coulson–Fischer (CF) point in single bond dissociations, when the optimal reference determinant is spin-polarized. Many excited states exhibit sharp kinks at the CF point, and connect to different dissociation limits via a zone of unphysical concave curvature. In particular, the unrestricted M S = 0 lowest triplet T 1 state changes character, and does not dissociate into ground state fragments. The unrestricted M S = ±1 T 1 CIS states better approximate the physical dissociation limit, but their degeneracy is broken beyond the CF point for most single bond dissociations. On the other hand, the M S = ±1 T 1 TDHF states reach the asymptote too soon, by merging with the ground state from the CF point onwards. Use of local exchange–correlation functionals causes M S = ±1 T 1 TDDFT states to resemble their unphysical M S = 0 counterpart. The 2 orbital, 2-electron model system of minimal basis H 2 is analytically treated to understand the origin of these issues, revealing that the lack of double excitations is at the root of these remarkable observations. In conclusion, the behavior of excited state surfaces is also numerically examined for species like H 2 , NH 3 , C 2 H 6 and LiH in extended basis sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous beam sampling and aperture shape optimization for SPORT

Purpose: Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: The authors build a mathematical model with the fundamental station point parameters as the decision variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. Results: A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. Conclusions: The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new adaptive light beam focusing principle for scanning light stimulation systems

In this article a novel principle to achieve optimal focusing conditions or rather the smallest possible beam diameter for scanning light stimulation systems is presented. It is based on the following methodology: First, a reference point on a camera sensor is introduced where optimal focusing conditions are adjusted and the distance between the light focusing optic and the reference point is determined using a laser displacement sensor. In a second step, this displacement sensor is used to map the topography of the sample under investigation. Finally, the actual measurement is conducted, using optimal focusing conditions in each measurement point at the sample surface, that are determined by the height difference between camera sensor and the sample topography. This principle is independent of the measurement values, the optical or electrical properties of the sample, the used light source, or the selected wavelength. Furthermore, the samples can be tilted, rough, bent, or of different surface materials. In the following the principle is implemented using an optical beam induced current system, but basically it can be applied to any other scanning light stimulation system. Measurements to demonstrate its operation are shown, using a polycrystalline silicon solar cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A persistent adjoint method with dynamic time-scaling and an application to mass action kinetics

In this article, we consider an optimization problem where the objective function is evaluated at the fixed-point of a contraction mapping parameterized by a control variable, and optimization takes place over this control variable. Since the derivative of the fixed-point with respect to the parameter can usually not be evaluated exactly, an adjoint dynamical system can be used to estimate gradients. Using this estimation procedure, the optimization algorithm alternates between derivative estimation and an approximate gradient descent step. We analyze a variant of this approach involving dynamic time-scaling, where after each parameter update the adjoint system is iterated until a convergence threshold is passed. Here, we prove that, under certain conditions, the algorithm can find approximate stationary points of the objective function. We demonstrate the approach in the settings of an inverse problem in chemical kinetics, and learning in attractor networks.

97 MATHEMATICS AND COMPUTING↗

Equilibrium Control Policies for Markov Chains

The average cost criterion has held great intuitive appeal and has attracted considerable attention. It is widely employed when controlling dynamic systems that evolve stochastically over time by means of formulating an optimization problem to achieve long-term goals efficiently. The average cost criterion is especially appealing when the decision-making process is long compared to other timescales involved, and there is no compelling motivation to select short-term optimization. This paper addresses the problem of controlling a Markov chain so as to minimize the average cost per unit time. Our approach treats the problem as a dual constrained optimization problem. We derive conditions guaranteeing that a saddle point exists for the new dual problem and we show that this saddle point is an equilibrium control policy for each state of the Markov chain. For practical situations with constraints consistent to those we study here, our results imply that recognition of such saddle points may be of value in deriving in real time an optimal control policy.

99 GENERAL AND MISCELLANEOUS↗

Optimizing probe design for an implantable perfusion and oxygenation sensor

In an effort to develop an implantable optical perfusion and oxygenation sensor, based on multiwavelength reflectance pulse oximetry, we investigate the effect of source–detector separation and other source detector characteristics to optimize the sensor’s signal to background ratio using Monte Carlo (MC) based simulations and in vitro phantom studies. Separations in the range 0.45 to 1.25 mm were found to be optimal in the case of a point source. The numerical aperture (NA) of the source had no effect on the collected signal while the widening of the source spatial profile caused a shift in the optimal source-detector separation. Specifically, for a 4.5 mm flat beam and a 2.4 mm × 2.5 mm photodetector, the optimal performance was found to be when the source and detector are adjacent to each other. These modeling results were confirmed by data collected from in vitro experiments on a liver phantom perfused with dye solutions mimicking the absorption properties of hemoglobin for different oxygenation states.

42 ENGINEERING↗