Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pointing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

One-parameter semigroups of analytic functions, fixed points and the Koenigs function

Analogues of the Berkson-Porta formula for the infinitesimal generator of a one-parameter semigroup of holomorphic maps of the unit disc into itself are obtained in the case when, along with a Denjoy-Wolff point, there also exist other fixed points. With each one-parameter semigroup a so-called Koenigs function is associated, which is a solution, common for all elements of the one-parameter semigroup, of a certain functional equation (Schroeder's equation in the case of an interior Denjoy-Wolff point and Abel's equation in the case of a boundary Denjoy-Wolff point). A parametric representation for classes of Koenigs functions that takes account of the Denjoy-Wolff point and other fixed points of the maps in the one-parameter semigroup is presented. Bibliography: 19 titles.

97 MATHEMATICS AND COMPUTING↗

Local Petrovskii lacunas close to parabolic singular points of the wavefronts of strictly hyperbolic partial differential equations

We enumerate the local Petrovskii lacunas (that is, the domains of local regularity of the principal fundamental solutions of strictly hyperbolic PDEs with constant coefficients in R{sup N}) close to parabolic singular points of their wavefronts (that is, at the points of types P{sub 8}{sup 1}, P{sub 8}{sup 2}, ±X{sub 9}, X{sub 9}{sup 1}, X{sub 9}{sup 2}, J{sub 10}{sup 1} and J{sub 10}{sup 3}). These points form the next most difficult family of classes in the natural classification of singular points after the so-called simple singularities A{sub k}, D{sub k}, E{sub 6}, E{sub 7} and E{sub 8}, which have been investigated previously. Also we present a computer program which counts the topologically distinct morsifications of critical points of smooth functions, and hence also the local components of the complement of a generic wavefront at its singular points. Bibliography: 22 titles. (paper)

97 MATHEMATICS AND COMPUTING↗

Turning points in the age–metallicity relations – created by late satellite infall and enhanced by radial migration

ABSTRACT The present-day age–metallicity relation (AMR) is a record of the star formation history of galaxies, as this traces the chemical enrichment of the gas over time. We use a zoomed-in cosmological simulation that reproduces key signatures of the Milky Way (MW), g2.79e12 from the NIHAO-UHD project, to examine how stellar migration and satellite infall shape the AMR across the disc. We find in the simulation, similar to the MW, the AMR in small spatial regions (R, z) shows turning points that connect changes in the direction of the relations. The turning points in the AMR in the simulation are a signature of late satellite infall. This satellite infall has a mass radio similar as that of the Sagittarius dwarf to the MW (∼0.001). Stars in the apex of the turning points are young and have nearly not migrated. The late satellite infall creates the turning points via depositing metal-poor gas in the disc, triggering star formation of stars in a narrow metallicity range compared to the overall AMR. The main effect of radial migration on the AMR turning points is to widen the metallicity range of the apex. This can happen when radial migration brings stars born from the infallen gas in other spatial bins, with slightly different metallicities, into the spatial bin of interest. These results indicate that it is possible that the passage of the Sagittarius dwarf galaxy played a role in creating the turning points that we see in the AMR in the Milky Way.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared fixed points of higher-spin fermions in topological semimetals

We determine the fate of interacting fermions described by the Hamiltonian H = p ∙ J in three-dimensional topological semimetals with linear band crossing, where p is momentum and J are the spin- j matrices for half-integer pseudospin j ≥ 3/2. While weak short-range interactions are irrelevant at the crossing point due to the vanishing density of states, weak long-range Coulomb interactions lead to a renormalization of the band structure. Using a self-consistent perturbative renormalization group approach, we show that band crossings of the type p ∙ J are unstable for j ≤ 7/2. Instead, through an intriguing interplay between cubic crystal symmetry, band topology, and interaction effects, the system is attracted to a variety of infrared fixed points. We also unravel several other properties of higher-spin fermions for general j , such as the relation between fermion self-energy and free energy, or the vanishing of the renormalized charge. An O(3) symmetric fixed point composed of equal chirality Weyl fermions is stable for j ≤ 7/2 and very likely so for all j. We then explore the rich fixed point structure for j = 5/2 in detail. We find additional attractive fixed points with enhanced O ( 3 ) symmetry that host both emergent Weyl or massless Dirac fermions, and identify a puzzling, infrared stable, anisotropic fixed point without enhanced symmetry in close analogy to the known case of j = 3/2.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Complete treatment of galaxy two-point statistics: Gravitational lensing effects and redshift-space distortions

We present a coherent theoretical framework for computing gravitational lensing effects and redshift-space distortions in an inhomogeneous universe and investigate their impacts on galaxy two-point statistics. Adopting the linearized Friedmann-Lemaitre-Robertson-Walker metric, we derive the gravitational lensing and the generalized Sachs-Wolfe effects that include the weak lensing distortion, magnification, and time delay effects, and the redshift-space distortion, Sachs-Wolfe, and integrated Sachs-Wolfe effects, respectively. Based on this framework, we first compute their effects on observed source fluctuations, separating them as two physically distinct origins: the volume effect that involves the change of volume and is always present in galaxy two-point statistics, and the source effect that depends on the intrinsic properties of source populations. Then we identify several terms that are ignored in the standard method, and we compute the observed galaxy two-point statistics, an ensemble average of all the combinations of the intrinsic source fluctuations and the additional contributions from the gravitational lensing and the generalized Sachs-Wolfe effects. This unified treatment of galaxy two-point statistics clarifies the relation of the gravitational lensing and the generalized Sachs-Wolfe effects to the metric perturbations and the underlying matter fluctuations. For near-future dark energy surveys, we compute additional contributions to the observed galaxy two-point statistics and analyze their impact on the anisotropic structure. Thorough theoretical modeling of galaxy two-point statistics would be not only necessary to analyze precision measurements from upcoming dark energy surveys, but also provide further discriminatory power in understanding the underlying physical mechanisms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase diagram and fixed-point structure of two-dimensional N=1 Wess-Zumino models

We study the phases and fixed-point structure of two-dimensional supersymmetric Wess-Zumino models with one supercharge. Our work is based on the functional renormalization group (RG) formulated in terms of a manifestly off-shell supersymmetric flow equation for the effective action. Within the derivative expansion, we solve the flow of the superpotential also including the anomalous dimension of the superfield. The models exhibit a surprisingly rich fixed-point structure with a discrete number of fixed-point superpotentials. Each fixed-point superpotential is characterized by its number of nodes and by the number of RG-relevant directions. In limiting cases, we find periodic superpotentials and potentials which confine the fields to a compact target space. The maximally IR-attractive fixed point has one relevant direction, the tuning of which distinguishes between supersymmetric and broken phases. For the Wess-Zumino model defined near the Gaussian fixed point, we determine the phase diagram and compute the corresponding ground-state masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamics of interaction between dislocations and point defects in bcc iron

The interaction between dislocations and point defects is crucial for many physical properties and phenomena in materials, such as strengthening mechanisms, dislocation bias and void swelling, creep, and impurity segregation around dislocations. Conventional dislocation-point defect interaction models use approximations based on elasticity theory and/or based on assumptions that transition states energies can be deduced from the binding energies of the defects. In this paper, we present the transport properties of point defects near dislocations based on the actual saddle-point configuration of vacancies and self-interstitial atoms as a function of position with respect to screw and edge dislocations in a model system (bcc iron) using the self-evolving atomistic kinetic Monte Carlo. Here, KMC simulations reveal defect dynamics near dislocations are highly anisotropic and correlated, particularly for dumbbells in the compressive field of the edge dislocation, which could result in zones near dislocation cores where dumbbells are less efficiently absorbed compared with vacancies. This study provides accurate saddle-point configurations and energies required to properly describe the dynamics of point defects around dislocations, allowing fundamental insights on the transport mechanisms which are essential for understanding microstructural evolution and mechanical properties of metallic materials.

36 MATERIALS SCIENCE↗

FRaZ: A Generic High-Fidelity Fixed-Ratio Lossy Compression Framework for Scientific Floating-point Data

With ever-increasing volumes of scientific floating-point data being produced by high-performance computing applications, significantly reducing scientific floating-point data size is critical, and error-controlled lossy compressors have been developed for years. None of the existing scientific floating-point lossy data compressors, however, support effective fixed-ratio lossy compression. Yet fixed-ratio lossy compression for scientific floating-point data not only compresses to the requested ratio but also respects a user-specified error bound with higher fidelity. In this paper, we present FRaZ: a generic fixed-ratio lossy compression framework respecting user-specified error constraints. The contribution is twofold. (1) We develop an efficient iterative approach to accurately determine the appropriate error settings for different lossy compressors based on target compression ratios. (2) We perform a thorough performance and accuracy evaluation for our proposed fixed-ratio compression framework with multiple state-of-the-art error-controlled lossy compressors, using several real-world scientific floating-point datasets from different domains. Experiments show that FRaZ effectively identifies the optimum error setting in the entire error setting space of any given lossy compressor. While fixed-ratio lossy compression is slower than fixed-error compression, it provides an important new lossy compression technique for users of very large scientific floating-point datasets.

Underwood, Robert↗

A Homotopy-Based Method for Robust Computation of Controlling Unstable Equilibrium Points

This paper proposes a homotopy-based method for efficiently computing and precisely determining controlling unstable equilibrium points (CUEPs) in transient stability analysis and screening using direct methods. The proposed method is intended to overcome potential numerical convergence problems associated with computing CUEPs. These convergence problems are mostly due to irregularities in the region of convergence of CUEPs which make it difficult to determine suitable initial points. The most commonly used initial points in computing CUEPs are minimum gradient points (MGPs) on the stability boundary which in turn rely on the determination of exit points (EPs-points at which sustained-fault trajectories exit system stability boundaries). However, determination of MGPs and EPs are computationally involved and sophisticated numerical methods have been introduced such as stability-boundary-following procedure and shadowing method to correct the solution trajectory. The proposed method does not depend on MGPs and also does not require accurate EPs. The proposed method maps the solution from EPs to the CUEPs. The proposed method is applied on several known systems including the NE 39 bus system and the reduced WECC system and the results are provided. The results are compared with the traditional methods such as Boundary of stability region based CUEP method (BCU method).

42 ENGINEERING↗

HiSpatialCluster: A novel high‐performance software tool for clustering massive spatial points

Abstract In the era of big data, spatial clustering is a very important means for geo‐data analysis. When clustering big geo‐data such as social media check‐in data, geotagged photos, and taxi trajectory points, traditional spatial clustering algorithms are facing more challenges. On the one hand, existing spatial clustering tools cannot support the clustering of massive point sets; on the other hand, there is no perfect solution for self‐adaptive spatial clustering. In order to achieve clustering of millions or even billions of points adaptively, a new spatial clustering tool—HiSpatialCluster—was proposed, in which the CFSFDP (clustering by fast search and finding density peaks) idea to find cluster centers and the DBSCAN (density‐based spatial clustering of applications with noise) idea of density‐connect filtering for classification are introduced. The tool’s source codes and other resources have been released on Github, and experimental evaluation was performed through clustering massive taxi trajectory points and Flickr geotagged photos in Beijing, China. The spatial clustering results were compared with those through K‐means and DBSCAN as well. As a spatial clustering tool, HiSpatialCluster is expected to play a fundamental role in big geo‐data research. First, this tool enables clustering adaptively on massive point datasets with uneven spatial density distribution. Second, the density‐connect filter method is applied to generate homogeneous analysis units from geotagged data. Third, the tool is accelerated by both parallel CPU and GPU computing so that millions or even billions of points can be clustered efficiently.

Chen, Yiran↗

SU-E-T-157: Evaluation and Comparison of Doses to Pelvic Lymph Nodes and to Point B with 3D Image Guided Treatment Planning for High Dose Brachytherapy for Treatment of Cervical Cancer

Purpose: To estimate and compare the doses received by the obturator, external and internal iliac lymph nodes and point Methods: CT-MR fused image sets of 15 patients obtained for each of 5 fractions of HDR brachytherapy using tandem and ring applicator, were used to generate treatment plans optimized to deliver a prescription dose to HRCTV-D90 and to minimize the doses to organs at risk (OARs). For each set of image, target volume (GTV, HRCTV) OARs (Bladder, Rectum, Sigmoid), and both left and right pelvic lymph nodes (obturator, external and internal iliac lymph nodes) were delineated. Dose-volume histograms (DVH) were generated for pelvic nodal groups (left and right obturator group, internal and external iliac chains) Per fraction DVH parameters used for dose comparison included dose to 100% volume (D100), and dose received by 2cc (D2cc), 1cc (D1cc) and 0.1 cc (D0.1cc) of nodal volume. Dose to point B was compared with each DVH parameter using 2 sided t-test. Pearson correlation were determined to examine relationship of point B dose with nodal DVH parameters. Results: FIGO clinical stage varied from 1B1 to IIIB. The median pretreatment tumor diameter measured on MRI was 4.5 cm (2.7– 6.4cm).The median dose to bilateral point B was 1.20 Gy ± 0.12 or 20% of the prescription dose. The correlation coefficients were all <0.60 for all nodal DVH parameters indicating low degree of correlation. Only 2 cc of obturator nodes was not significantly different from point B dose on t-test. Conclusion: Dose to point B does not adequately represent the dose to any specific pelvic nodal group. When using image guided 3D dose-volume optimized treatment nodal groups should be individually identified and delineated to obtain the doses received by pelvic nodes.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-11: A Segmentation and Point Matching Enhanced Deformable Image Registration Method for Dose Accumulation Between HDR CT Images

Purpose: To propose and validate a novel and accurate deformable image registration (DIR) scheme to facilitate dose accumulation among treatment fractions of high-dose-rate (HDR) gynecological brachytherapy. Method: We have developed a method to adapt DIR algorithms to gynecologic anatomies with HDR applicators by incorporating a segmentation step and a point-matching step into an existing DIR framework. In the segmentation step, random walks algorithm is used to accurately segment and remove the applicator region (AR) in the HDR CT image. A semi-automatic seed point generation approach is developed to obtain the incremented foreground and background point sets to feed the random walks algorithm. In the subsequent point-matching step, a feature-based thin-plate spline-robust point matching (TPS-RPM) algorithm is employed for AR surface point matching. With the resulting mapping, a DVF characteristic of the deformation between the two AR surfaces is generated by B-spline approximation, which serves as the initial DVF for the following Demons DIR between the two AR-free HDR CT images. Finally, the calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. Results: The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative results as well as the visual inspection of the DIR indicate that our proposed method can suppress the interference of the applicator with the DIR algorithm, and accurately register HDR CT images as well as deform and add interfractional HDR doses. Conclusions: We have developed a novel and robust DIR scheme that can perform registration between HDR gynecological CT images and yield accurate registration results. This new DIR scheme has potential for accurate interfractional HDR dose accumulation. This work is supported in part by the National Natural ScienceFoundation of China (no 30970866 and no 81301940)

60 APPLIED LIFE SCIENCES↗

Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field

Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product (DAP) measured can theoretically be linked to an absorbed dose at a point by the determination of a profile correction. This study aims at comparing the DAP-based protocol to the usual absorbed dose at a point protocol in a 2 cm diameter field for which both references exist. Methods: Two calorimeters were used, respectively, with a sensitive volume of 0.6 cm (for the absorbed dose at a point measurement) and 3 cm diameter (for the DAP measurement). Profile correction was calculated from a 2D dose mapping using three detectors: a PinPoint chamber, a synthetic diamond, and EBT3 films. A specific protocol to read EBT3 films was implemented and the dose-rate and energy dependences were studied to assure a precise measurement, especially in the penumbra and out-of-field regions. Results: EBT3 films were found independent on dose rates over the range studied but showed a strong under-response (18%) at low energies. Depending on the dosimeter used for calculating the profile correction, a deviation of 0.8% (PinPoint chamber), 0.9% (diamond), or 1.9% (EBT3 films) was observed between the calibration coefficient derived from DAP measurements and the one directly established in terms of absorbed dose to water at a point. Conclusions: The DAP method can currently be linked to the classical dosimetric reference system based in an absorbed dose at a point only with a confidence interval of 95% (k = 2). None of the detectors studied can be used to determine an absorbed dose to water at a point from a DAP measurement with an uncertainty smaller than 1.2%.

60 APPLIED LIFE SCIENCES↗

SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?

Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were based on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largest potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in cervical HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-36: Dosimetric Comparison of Point Based Vs. Target Based Prescription for Intracavitary Brachytherapy in Cancer of the Cervix

Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinical target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription, while maintaining similar target coverage.

60 APPLIED LIFE SCIENCES↗

Spin Berry points as crucial for ultrafast demagnetization

Laser-induced ultrafast demagnetization has puzzled researchers around the world for over two decades. Intrinsic complexity in electronic, magnetic and phononic subsystems is difficult to understand microscopically. So far, it is not possible to explain demagnetization using a single mechanism, which suggests a crucial piece of information still missing. In this paper, we return to a fundamental aspect of physics: spin and its change within each band in the entire Brillouin zone. We employ face-centered cubic (fcc) Ni as an example and use an extremely dense k mesh to map out spin changes for every band close to the Fermi level along all the high symmetry lines. To our surprise, spin angular momentum at some special k points abruptly changes from [Formula: see text] to [Formula: see text] simply by moving from one crystal momentum point to the next. This explains why intraband transitions, which the spin superdiffusion model is based upon, can induce a sharp spin moment reduction, and why electric current can change spin orientation in spintronics. These special k points, which are called spin Berry points [M. V. Berry, Proc. R. Soc. Lond. A 393 (1984) 45], are not random and appear when several bands are close to each other, so the Berry potential of spin majority states is different from that of spin minority states. Although within a single band, spin Berry points jump, when we group several neighboring bands together, they form distinctive smooth spin Berry lines. It is the band structure that disrupts those lines. Spin Berry points are crucial to laser-induced ultrafast demagnetization and spintronics.

Physics↗

Coincidence of the Measured Voltage Peak and the Measured Current Inflection Point in Exploding Metals

Exploding Bridgewire (EBW) Detonators and Exploding Foil Initiators (EFI's, e.g. Slappers) have unique current and voltage characteristics marked by a large voltage spike and an inflection point in the current. Mathematically, it is shown that the voltage peak and the current inflection point must align in time. Models concur with the math and show voltage peaks occurring at the same point in time as the inflection point. Circuit analysis is performed to demonstrate why the voltage peak and current inflection point will almost never align in time for an experiment. To correctly analyze exploding metal behavior, the current inflection point and voltage peak must be manually aligned in time. These conclusions apply to single detonators where current and voltage is measured on those detonators. In multi-detonator systems, the conclusions herein apply only for cases where current and voltage are obtained for each detonator individually. The conclusions will begin to break down as measurements become combined.

36 MATERIALS SCIENCE↗

Deep learning models for interpretation of point of care ultrasound in military working dogs

Introduction: Military working dogs (MWDs) are essential for military operations in a wide range of missions. With this pivotal role, MWDs can become casualties requiring specialized veterinary care that may not always be available far forward on the battlefield. Some injuries such as pneumothorax, hemothorax, or abdominal hemorrhage can be diagnosed using point of care ultrasound (POCUS) such as the Global FAST® exam. This presents a unique opportunity for artificial intelligence (AI) to aid in the interpretation of ultrasound images. In this article, deep learning classification neural networks were developed for POCUS assessment in MWDs. Methods: Images were collected in five MWDs under general anesthesia or deep sedation for all scan points in the Global FAST® exam. For representative injuries, a cadaver model was used from which positive and negative injury images were captured. A total of 327 ultrasound clips were captured and split across scan points for training three different AI network architectures: MobileNetV2, DarkNet-19, and ShrapML. Gradient class activation mapping (GradCAM) overlays were generated for representative images to better explain AI predictions. Results: Performance of AI models reached over 82% accuracy for all scan points. The model with the highest performance was trained with the MobileNetV2 network for the cystocolic scan point achieving 99.8% accuracy. Across all trained networks the diaphragmatic hepatorenal scan point had the best overall performance. However, GradCAM overlays showed that the models with highest accuracy, like MobileNetV2, were not always identifying relevant features. Conversely, the GradCAM heatmaps for ShrapML show general agreement with regions most indicative of fluid accumulation. Discussion: Overall, the AI models developed can automate POCUS predictions in MWDs. Preliminarily, ShrapML had the strongest performance and prediction rate paired with accurately tracking fluid accumulation sites, making it the most suitable option for eventual real-time deployment with ultrasound systems. Further integration of this technology with imaging technologies will expand use of POCUS-based triage of MWDs.

59 BASIC BIOLOGICAL SCIENCES↗