Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

BUILD: A community development simulation game, appendix A

The computer based urban decision-making game BUILD is described. BUILD is aimed at: (1) allowing maximum expression of value positions by participants through resolution of intense, task-oriented conflicts: (2) heuristically gathering information on both the technical and social functioning of the city through feedback from participants: (3) providing community participants with access to technical expertise in urban decision making, and to expose professionals to the value positions of the community: and (4) laying the groundwork for eventual development of an actual policy making tool. A brief description of the roles, sample input/output formats, an initial scenario, and information on accessing the game through a time-sharing system are included.

Orlando, J. A.↗

Sub-milliarcsecond determination of pole position using Global Positioning System data

The determination of pole-position variations from the analysis of 23 days of Global Positioning System (GPS) data continuously collected with a globally distributed, 21-station network is discussed. The comparison of the estimated pole positions from these data with results from 11 very long baseline interferometry (VLBI) experiments conducted during this same interval yields weighted root-mean-square differences about the mean differences of 0.5 mas for both X- and Y-pole position estimates from an analysis using single-day arcs, and 1.0 and 0.8 mas from an analysis using three weekly multiday arcs. These results are of sufficient quality that GPS could provide an alternative technique to VLBI and satellite laser ranging for regular monitoring of high-time-resolution variations in the position of the earth's rotation axis.

Herring, Thomas A.↗

Formal Verification of Safety Buffers for Sate-Based Conflict Detection and Resolution

The information provided by global positioning systems is never totally exact, and there are always errors when measuring position and velocity of moving objects such as aircraft. This paper studies the effects of these errors in the actual separation of aircraft in the context of state-based conflict detection and resolution. Assuming that the state information is uncertain but that bounds on the errors are known, this paper provides an analytical definition of a safety buffer and sufficient conditions under which this buffer guarantees that actual conflicts are detected and solved. The results are presented as theorems, which were formally proven using a mechanical theorem prover.

Herencia-Zapana, Heber↗

ORION’S VEIL: MAGNETIC FIELD STRENGTHS AND OTHER PROPERTIES OF A PDR IN FRONT OF THE TRAPEZIUM CLUSTER

We present an analysis of physical conditions in the Orion Veil, an atomic photon-dominated region (PDR) that lies just in front (≈2 pc) of the Trapezium stars of Orion. This region offers an unusual opportunity to study the properties of PDRs, including the magnetic field. We have obtained 21 cm H i and 18 cm (1665 and 1667 MHz) OH Zeeman effect data that yield images of the line-of-sight magnetic field strength B {sub los} in atomic and molecular regions of the Veil. We find B {sub los} ≈ −50 to −75 μ G in the atomic gas across much of the Veil (25″ resolution) and B {sub los} ≈ −350 μ G at one position in the molecular gas (40″ resolution). The Veil has two principal H i velocity components. Magnetic and kinematical data suggest a close connection between these components. They may represent gas on either side of a shock wave preceding a weak-D ionization front. Magnetic fields in the Veil H i components are 3–5 times stronger than they are elsewhere in the interstellar medium where N (H) and n (H) are comparable. The H i components are magnetically subcritical (magnetically dominated), like the cold neutral medium, although they are about 1 dex denser. Comparatively strong fields in the Veil H i components may have resulted from low-turbulence conditions in the diffuse gas that gave rise to OMC-1. Strong fields may also be related to magnetostatic equilibrium that has developed in the Veil since star formation. We also consider the location of the Orion-S molecular core, proposing a location behind the main Orion H{sup +} region.

79 ASTRONOMY AND ASTROPHYSICS↗

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.↗

SU-E-T-433: Calibration Accuracy in Mailed High-Resolution 3D Dosimetry Service for SRS/SBRT QA

Purpose: SRS/SBRT combines hypofractionation with excellent dose distributions. However, extremely steep gradients across the target along with dose escalation, if not administered accurately, may lead to serious complications, recurrences, or even fatalities. Existing commercial QA products either lack adequate spatial resolution or the 3D aspect. By contrast, the new CrystalBall™ mailed high-resolution 3D dosimetry service removes the above limitations while reducing the overall workload on medical physics staff. The exposed dosimeters, which change optical density in proportion to local dose, are sent back to the manufacturer (MGS Research Inc., Madison, CT) for sub-millimeter-resolution laser-CT scanning and QA data analysis. QA report is returned electronically within 24 hours. The purpose of this study was to evaluate the dose calibration accuracy in this system. Methods: Two spherical CrystalBall™ polymer gel dosimeters from the same batch, 166 mm diameter, with embedded 3D image registration markers, were mounted in a special phantom designed for reproducible positioning. For full end to end testing, the optical guidance array was mounted onto the phantom and a CT was taken. Two separate Rapid Arc SRS plans were designed. Varian Medical Systems optical guidance system was used to position the phantom and the SRS treatment plans were delivered to the two spheres on Varian's Trilogy Accelerator. Exposed dosimeters were mailed back to the manufacturer for laser CT scanning and analysis. Results: For each plan, 3D gamma passing rate was 100% for 2%/2mm distance-to-agreement criteria above 50% isodose level. The two calibration curves, generated using volumetric dose and optical density data, showed excellent mutual agreement (max difference 2.2%, median difference 0.75%). Conclusion: The clinical utility of new CrystalBall™ mailed QA service for SRS/SBRT and high accuracy of dose calibration have been validated. The workflow associated with the use of the CrystalBall™ in clinical setting was found to be minimal. The presenting author is the founder of and has an ownership in MGS Research Inc which manufactures the CrystalBall system for 3D dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Survey of ultraviolet shuttle glow

The University of Colorado Get Away Special (GAS) project utilizes the efforts of its students to place experiments on the shuttle. The objective of one experiment, the shuttle glow study, is to conduct a general survey of emissions in the ultraviolet near vehicle surfaces. An approximate wavelength range of 1900 to 3000 A will be scanned to observe predominant features. Special emphasis will be placed on studying the band structure of NO near 2000 A and the Mg+ line at 2800 A. The spectrometer, of Ebert-Faste 1/8-meter design, will perform the experiment during spacecraft night. It will be oriented such that the optical axis points to the cargo bay zenith. In order to direct the field-of-view of the instrument onto the shuttle vertical stabilizer (tail), a mirror assembly is employed. The mirror system has been designed to rotate through 7.5 degrees of arc using 10 positions resulting in a spatial resolution of 30 x 3 cm, with the larger dimension corresponding to the horizontal direction. Such a configuration can be attained from the forwardmost position in the cargo bay. Each spatial position will be subjected to a full spectral scan with a resolution on the order of 10 A.

Spear, K. A.↗

High energy-resolution studies of electron impact optical excitation functions. I - The second positive system of N2.

The relative emission cross section for the N2 second positive system (0,0) and (1,0) bands excited by electron impact was measured for incident electron energies from threshold to 17 eV. The use of a high energy-resolution electron spectrometer coupled to an optical detection system made it possible to obtain the measurements with an incident electron beam having an energy half width of 50 meV. Calibration of the incident electron energy was provided by observing the scattering resonances in nitrogen and helium. The maximum of the (0,0) and (1,0) bands were found to be at approximately 14.02 and 14.3 eV, respectively. A small structural feature that was pressure-independent appeared only in the (0,0) band emission cross section. Another such feature was pressure-dependent and appeared more strongly in the (1,0) band cross section.

Finn, T. G.↗

Automatic generation of IGUN{sup (C)} input files for enhanced mesh resolution at the plasma meniscus

The plasma-beam interface (meniscus) is highly nonlinear and its correct simulation needs a mesh resolution of the order of the Debye length. In high intensity ion sources, the plasma density is usually too high and the Debye length is too small for a sufficient mesh resolution. A well established method to overcome this dilemma is the use of a field line and an equipotential line to be created in a first run, in order to dissect the simulation problem into a plasma part with much higher mesh resolution and a transport part with usual resolution. In the past many users of IGUN have found it difficult to perform this dissection. Therefore, a new feature has been added to IGUN to automatically write new input files for the dissected areas. For this a field line starting point needs to be defined as well as the potential of a pseudo electrode. The field line then is used for the plasma part as a slanted and curved Neumann boundary, while the pseudo electrode will act as the extraction electrode. The trajectory end data then are used in the automatically generated concatenating run as ion starting input without any need for the user to adjust for positions or different mesh resolutions. Here we show as an example the simulation of the well-known CHORDIS ion source, the calculated field line, the pseudo equipotential line, and the resulting simulations for the automatically generated input files for the plasma and the transport parts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The structure of YqeH: An AtNOS1/AtNOA1 ortholog that couples GTP hydrolysis to molecular recognition

AtNOS1/AtNOA1 was identified as a nitric oxide-generating enzyme in plants, but that function has recently been questioned. To resolve issues surrounding AtNOA1 activity, we report the biochemical properties and a 2.36 {angstrom} resolution crystal structure of a bacterial AtNOA1 ortholog (YqeH). Geobacillus YqeH fused to a putative AtNOA1 leader peptide complements growth and morphological defects of Atnoa1 mutant plants. YqeH does not synthesize nitric oxide from L-arginine but rather hydrolyzes GTP. The YqeH structure reveals a circularly permuted GTPase domain and an unusual C-terminal {beta}-domain. A small N-terminal domain, disordered in the structure, binds zinc. Structural homology among the C-terminal domain, the RNA-binding regulator TRAP, and the hypoxia factor pVHL define a recognition module for peptides and nucleic acids. TRAP residues important for RNA binding are conserved by the YqeH C-terminal domain, whose positioning is coupled to GTP hydrolysis. YqeH and AtNOA1 probably act as G-proteins that regulate nucleic acid recognition and not as nitric-oxide synthases.

36 MATERIALS SCIENCE↗

Crystal structure of a 3B3 variant - A broadly neutralizing HIV-1 scFv antibody

We present the crystal structure determination of an anti-HIV-1 gp120 single-chain variable fragment antibody variant, 3B3, at 2.5 {angstrom} resolution. This 3B3 variant was derived from the b12 antibody, using phage display and site-directed mutagenesis of the variable heavy chain (V{sub H}) complementary-determining regions (CDRs). 3B3 exhibits enhanced binding affinity and neutralization activity against several cross-clade primary isolates of HIV-1 by interaction with the recessed CD4-binding site on the gp120 envelope protein. Comparison with the structures of the unbound and bound forms of b12, the 3B3 structure closely resembles these structures with minimal differences with two notable exceptions. First, there is a reorientation of the CDR-H3 of the V{sub H} domain where the primary sequences evolved from b12 to 3B3. The structural changes in CDR-H3 of 3B3, in light of the b12-gp120 complex structure, allow for positioning an additional Trp side chain in the binding interface with gp120. Finally, the second region of structural change involves two peptide bond flips in CDR-L3 of the variable light (VL) domain triggered by a point mutation in CDR-H3 of Q100eY resulting in changes in the intramolecular hydrogen bonding patterning between the VL and VH domains. Thus, the enhanced binding affinities and neutralization capabilities of 3B3 relative to b12 probably result from higher hydrophobic driving potential by burying more aromatic residues at the 3B3-gp120 interface and by indirect stabilization of intramolecular contacts of the core framework residues between the VL and VH domains possibly through more favorable entropic effect through the expulsion of water.

08 HYDROGEN↗

Crystal structures of the free and inhibited forms of plasmepsin I (PMI) from Plasmodium falciparum

Plasmepsin I (PMI) is one of the four vacuolar pepsin-like proteases responsible for hemoglobin degradation by the malarial parasite Plasmodium falciparum, and the only one with no crystal structure reported to date. Due to substantial functional redundancy of these enzymes, lack of inhibition of even a single plasmepsin can defeat efforts in creating effective antiparasitic agents. We have now solved crystal structures of the recombinant PMI as apoenzyme and in complex with the potent peptidic inhibitor, KNI-10006, at the resolution of 2.4 and 3.1 {angstrom}, respectively. The apoenzyme crystallized in the orthorhombic space group P2{sub 1}2{sub 1}2{sub 1} with two molecules in the asymmetric unit and the structure has been refined to the final R-factor of 20.7%. The KNI-10006 bound enzyme crystallized in the tetragonal space group P4{sub 3} with four molecules in the asymmetric unit and the structure has been refined to the final R-factor of 21.1%. In the PMI-KNI-10006 complex, the inhibitors were bound identically to all four enzyme molecules, with the opposite directionality of the main chain of KNI-10006 relative to the direction of the enzyme substrates. Such a mode of binding of inhibitors containing an allophenylnorstatine-dimethylthioproline insert in the P1-P1' positions, previously reported in a complex with PMIV, demonstrates the importance of satisfying the requirements for the proper positioning of the functional groups in the mechanism-based inhibitors towards the catalytic machinery of aspartic proteases, as opposed to binding driven solely by the specificity of the individual enzymes. A comparison of the structure of the PMI-KNI-10006 complex with the structures of other vacuolar plasmepsins identified the important differences between them and may help in the design of specific inhibitors targeting the individual enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

BaBrI:Eu2 + , a new bright scintillator

The scintillation properties of BaBrI:Eu2+ are reported. Crystals were produced by the vertical Bridgman technique in a sealed quartz ampoule. Excellent scintillation properties were measured. A light yield of 81,0007 +- 3000 photons per MeV (ph/MeV) of absorbed gamma-ray energy was measured. An energy resolution (FWHM over peak position) of 4.870.5percent was observed for the 662keV full absorption peak. Pulsed X-ray luminescence measurements show two exponential decay components of 297 and 482 ns with a contribution to the total light output of 23percent and 77percent, respectively. Under X-ray and UV excitation, the emission corresponds to a broadband center at 413 nm. These initial values make BaBrI:Eu2+ one of the brightest and the fastest known Eu2+ doped scintillators.

36 MATERIALS SCIENCE↗

Structure and Catalytic Properties of an Engineered Heterodimer of Enolase Composed of One Active and One Inactive Subunit

Enolase is a dimeric enzyme that catalyzes the interconversion of 2-phospho-D-glycerate and phosphoenolpyruvate. This reversible dehydration is effected by general acid-base catalysis that involves, principally, Lys345 and Glu211 (numbering system of enolase 1 from yeast). The crystal structure of the inactive E211Q enolase shows that the protein is properly folded. However, K345 variants have, thus far, failed to crystallize. This problem was solved by crystallization of an engineered heterodimer of enolase. The heterodimer was composed of an inactive subunit that has a K345A mutation and an active subunit that has N80D and N126D surface mutations to facilitate ion-exchange chromatographic separation of the three dimeric species. The structure of this heterodimeric variant, in complex with substrate/product, was obtained at 1.85 {angstrom} resolution. The structure was compared to a new structure of wild-type enolase obtained from crystals belonging to the same space group. Asymmetric dimers having one subunit exhibiting two of the three active site loops in an open conformation and the other in a conformation having all three loops closed appear in both structures. The K345A subunit of the heterodimer is in the loop-closed conformation; its C{sup {alpha}} carbon atoms closely match those of the corresponding subunit of wild-type enolase (root-mean-squared deviation of 0.23 {angstrom}). The kcat and k{sub cat}/K{sub m} values of the heterodimer are approximately half those of the N80D/N126D homodimer, which suggests that the subunits in solution are kinetically independent. A comparison of enolase structures obtained from crystals belonging to different space groups suggests that asymmetric dimers can be a consequence of the asymmetric positioning of the subunits within the crystal lattice.

36 MATERIALS SCIENCE↗

Detection of linearly polarized 6.9 mm continuum emission from the class 0 young stellar object NGC 1333 IRAS4A

We report new Karl G. Jansky Very Large Array (JVLA), 0--AMP--farcs;5 angular resolution observations of linearly polarized continuum emission at 6.9 mm, toward the class 0 young stellar object NGC 1333 IRAS4A. This target source is a collapsing dense molecular core that was resolved at short wavelengths to have an hourglass shaped B-field configuration. We compare these 6.9 mm observations with previous polarization Submillimeter Array observations at 0.88 mm, which have a comparable angular resolution (∼0--AMP--farcs;7). We find that at the same resolution, the observed polarization position angles at 6.9 mm are slightly deviated from those observed at 0.88 mm. Due to the lower optical depth of the emission at 6.9 mm, and the potential effect of dust grain growth, the new JVLA observations are likely probing B-field alignments in regions interior to those sampled by the previous polarization observations at higher frequencies. Our understanding can be improved with more sensitive observations, and with observations for the more extended spatial scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Wave-dispersive x-ray spectrometer for simultaneous acquisition of several characteristic lines based on strongly and accurately shaped Ge crystal

Si and Ge are widely used as analyzing crystals for x-rays. Drastic and accurate shaping of Si or Ge gives significant advance in the x-ray field, although covalently bonded Si or Ge crystals have long been believed to be not deformable to various shapes. Recently, we developed a deformation technique for obtaining strongly and accurately shaped Si or Ge wafers of high crystal quality, and the use of the deformed wafer made it possible to produce fine-focused x-rays. In the present study, we prepared a cylindrical Ge wafer with a radius of curvature of 50 mm, and acquired fluorescent x-rays simultaneously from four elements by combining the cylindrical Ge wafer with a position-sensitive detector. The energy resolution of the x-ray fluorescence spectrum was as good as that obtained using a flat single crystal, and its gain was over 100. The demonstration of the simultaneous acquisition of high-resolution x-ray fluorescence spectra indicated various possibilities of x-ray spectrometry, such as one-shot x-ray spectroscopy and highly efficient wave-dispersive x-ray spectrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A large open ratio, time, and position sensitive detector for time of flight measurements in UHV

We report on the construction of an UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard 2 inch Si wafer as a collector. The front end electronic is placed directly on the air side of the flange allowing excellent immunity to noise and a very good timing signal with reduced ringing. The important aberrations are corrected empirically providing an absolute positioning accuracy of 500 μm while a 150 μm resolution is measured in the center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluidic Flow Assisted Deterministic Folding of Van der Waals Materials

Origami offers a distinct approach for designing and engineering new material structures and properties. The folding and stacking of atomically thin van der Waals (vdW) materials, for example, can lead to intriguing new physical properties including bandgap tuning, Van Hove singularity, and superconductivity. On the other hand, achieving well-controlled folding of vdW materials with high spatial precision has been extremely challenging and difficult to scale toward large areas. In this paper, a deterministic technique is reported to fold vdW materials at a defined position and direction using microfluidic forces. Electron beam lithography (EBL) is utilized to define the folding area, which allows precise control of the folding geometry, direction, and position beyond 100 nm resolution. Using this technique, single-atomic-layer vdW materials or their heterostructures can be folded without the need for any external supporting layers in the final folded structure. In addition, arrays of patterns can be folded across a large area using this technique and electronic devices that can reconfigure device functionalities through folding are also demonstrated. Such scalable formation of folded vdW material structures with high precision can lead to the creation of new atomic-scale materials and superlattices as well as opening the door to realizing foldable and reconfigurable electronics.

2D materials↗