Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Distribution Faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Post-extreme-event restoration using linear topological constraints and DER scheduling to enhance distribution system resilience

In this paper, a post-extreme-event restoration (PEER) algorithm is proposed to improve distribution system resilience. Linear topological constraints are proposed to ensure radial topology after N-k contingencies, possibly in multiple islands. The approach is made comprehensive by considering dispatchable distributed energy resources (DERs), non-dispatchable DERs, and demand responses, as well as on-load tap changers (OLTCs) and shunt capacitors. The goal is to minimize the accumulative expense caused by load reduction payment or penalty, as well as DER operation cost. As a result, the overall system will survive longer with higher resilience during an extreme event. To verify the effectiveness of the PEER algorithm, we proposed a resilience evaluation algorithm using Monte Carlo simulation (MCS) with reduced scenarios. This is based on a probabilistic model for generating random scenarios which consider the uncertainty of line faults and solar irradiance. Combined with the proposed PEER algorithm, this reduced-scenario MCS can evaluate the expected energy not served (EENS) which is an essential index for distribution system resilience. Case studies of the IEEE 33-bus and 123-bus test systems validate the proposed algorithm in reducing EENS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Ground Fault Overvoltage Testing

This report describes testing conducted at NREL to determine the duration and magnitude of transient overvoltages created by several commercial PV inverters during ground fault conditions. For this work, a test plan developed by the Forum on Inverter Grid Integration Issues (FIGII) has been implemented in a custom test setup at NREL. Load rejection overvoltage test results were reported previously in a separate technical report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for a Medium-Voltage DC Electrolysis Testbed

Here we present the results of a study focused on the feasibility of using Medium Voltage DC (MVDC) power distribution from wind power generation to electrolyzers for hydrogen production. This approach, using hybrid energy generation in a MVDC microgrid, offers many advantages. These include possible improvements in efficiency, reliability and installation cost compared to a more typical state-of-the-art AC distribution configuration. It also eliminates the need for transformers, which have recently been subject to price volatility and availability concerns. This study highlights the practical feasibility of MVDC distribution networks for integrating various energy sources, offering improved efficiency and reduced system complexity compared to conventional AC-based solutions. Future work will focus on enhancing fault protection strategies, scaling the system to larger renewable installations, and conducting hardware implementation at the National Renewable Energy Laboratory's (NREL) Flatirons Campus (FC). In the sections that follow we show that a DC Collection and Distribution System (DC CDS) reduces the losses associated with the electrical conversion / distribution process relative to a state-of-the-art AC approach, improving overall efficiency by 5%. On the qualitative side, reducing the number of conversion stages is likely to improve reliability, reduce capital investment cost, and enable simpler control algorithms to be used, and reduced risk of instabilities and malfunctions.

08 HYDROGEN↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part II: Long Term Faults

Here, this paper addresses the transient stability (also called large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability, and frequency response for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted system' components present and is applicable to the study of both short term and long term faults. Part I of this research discussed the short term faults whereas as Part II, the present paper, discusses long term faults. This research considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000 MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Humming Trains in Seismology: An Opportune Source for Probing the Shallow Crust

Abstract Seismologists are eagerly seeking new and preferably low-cost ways to map and track changes in the complex structure of the top few kilometers of the crust. By understanding it better, they can build on what is known regarding important, practical issues. These include telling us whether imminent earthquakes and volcanic eruptions are generating telltale underground signs of hazard, about mitigation of induced seismicity such as from deep injection of wastewater, how the Earth and its atmosphere couple, and where accessible natural resources are. Passive seismic imaging usually relies on blind correlations within extended recordings of Earth’s ceaseless “hum” or coda of well-mixed, small vibrations. In this article, we propose a complementary approach. It is seismic interferometry using opportune sources—specifically ones not stationary in time and moving in a well-understood configuration. Its interpretation relies on an accurate understanding of how these sources radiate seismic waves, precise timing, careful placement of pairs of listening stations, and seismic phase differentiation (surface and body waves). Massive freight trains were only recently recognized as such a persistent, powerful cultural (human activity-caused) seismic source. One train passage may generate a tremor with an energy output of a magnitude 1 earthquake and be detectable for up to 100 km from the track. We discuss the source mechanisms of train tremors and review the basic theory on sources. Finally, we present case studies of body- and surface-wave retrieval as an aid to mineral exploration in Canada and to monitoring of a southern California fault zone. We believe noise recovery from this new signal source, together with dense data acquisition technologies such as nodes or distributed acoustic sensing, will deeply transform our ability to monitor activity in the shallow crust at sharpened resolution in time and space.

Geochemistry & Geophysics↗

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗

Hardware-in-the-loop grid simulator system and method

A hardware-in-the-loop (HIL) electrical grid simulation system and method that combines a reactive divider with a variable frequency converter to better mimic and control expected and unexpected parameters in an electrical grid. The invention provides grid simulation in a manner to allow improved testing of variable power generators, such as wind turbines, and their operation once interconnected with an electrical grid in multiple countries. The system further comprises an improved variable fault reactance (reactive divider) capable of providing a variable fault reactance power output to control a voltage profile, therein creating an arbitrary recovery voltage. The system further comprises an improved isolation transformer designed to isolate zero-sequence current from either a primary or secondary winding in a transformer or pass the zero-sequence current from a primary to a secondary winding.

17 WIND ENERGY↗

Implementing Admittance Relaying for Microgrid Protection

An earlier study evaluated issues with microgrid protection. This highlighted the difficulties with microgrid protection, which include: 1. lack of fault current from inverter-interfaced generation, 2. varying fault current between grid-connected and islanded modes, 3. potential for normally-meshed operation and 4. unbalanced operation due to single-phase loads. It is worth noting that not all microgrid designs will include all these challenges. For example, microgrids could choose to omit meshed operation. Previous work identified differential protection based on the discrete S-transform for line protection and admittance protection for load protection as possible solutions . However, some severe limitations were identified. This included the potential for blinding of the discrete S-transform protection when fault contribution on either end of the line is similar, and loss of protection selectivity for admittance protection in the case of upstream line-ground faults. This report investigates admittance protection as a solution for line and load protection in greater detail by comparing analytical and simulated results. Section 2 describes the protection schemes analyzed and the behavior of inverter-interfaced microgrids under faults in more detail. Section 3 derives sequence networks for the fault cases considered. Section 4 presents a transient model constructed to validate the impedances calculated from the sequence networks. Section 5 compares the results from the sequence networks and transient model. Last, Section 6 presents the conclusions of this study in terms of the suitability of admittance relaying for protection of inverter-interfaced microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Artificial Neural Network-based State Estimation for Low Observable, Unbalanced Microgrids for Microgrid Building Blocks

The microgrid building blocks (MBB) were proposed as microgrid components with combined sub-components with power conversion, communication, and microgrid control capability, or a subset of such sub-components. This work addresses the microgrid controller, present in an MBB, which requires accurate state estimation to perform its tasks, including for monitoring, power flow (dispatch), fault detection, etc. In this paper, an artificial neural network (ANN)-based framework for state estimation is proposed for an MBB, especially for unbalanced and low observable microgrids. To overcome the challenge of low observability in unbalanced systems, a concept of extended adjacent matrix is introduced to reduce the required number of measurements for state estimation. Addressing the challenges, a feed forward neural network (FNN) is utilized to enhance estimation accuracy and reliability with the reduced number of measurements. The proposed state estimation is validated through extensive simulations on a microgrid, which was achieved from the modified IEEE 34-bus distribution test feeder with multiple distributed energy resources (DERs) and demonstrated superior performance in estimation accuracy and low observability.

Choi, Jongchan↗

Microgrid Controllers : Expanding Their Role and Evaluating Their Performance

Microgrids have long been deployed to provide power to customers in remote areas as well as critical industrial and military loads. Today, they are also being proposed as grid-interactive solutions for energy-resilient communities. Such microgrids will spend most of the time operating while synchronized with the surrounding utility grid but will also be capable of separating during contingency periods due to storms or temporary disturbances such as local grid faults. Properly designed and grid-integrated microgrids can provide the flexibility, reliability, and resiliency needs of both the future grid and critical customers. These systems can be an integral part of future power system designs that optimize investments to achieve operational goals, improved reliability, and diversification of energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection of Distribution Circuits with High Penetration of Solar PV: Distance, Learning, and Estimation-Based Methods

The results of DOE Solar Energy Technologies Office project 34233 are presented. The newest version of IEEE Standard 1547 enables photovoltaic inverters to ride through voltage disturbances, improving bulk system reliability, at the expense of removing undervoltage trip as a fast method of de facto fault detection in high PV adoption scenarios. The project explored new methods of fault detection that don't rely on communication systems and could be available quickly, including distance-based schemes, focused directional relays, and two different data-driven schemes. The schemes were evaluated with fast-phasor simulation, electromagnetic transient simulation, and field data collection at partner utilities Chattanooga Electric Power Board and Dominion Energy Virginia. Accomplishments and possible paths forward are summarized.

14 SOLAR ENERGY↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Review of Design Elements within Power Infrastructure Cyber–Physical Test Beds as Threat Analysis Environments

Cyber–physical systems (CPSs) are an integral part of modern society; thus, enhancing these systems’ reliability and resilience is paramount. Cyber–physical testbeds (CPTs) are a safe way to test and explore the interplay between the cyber and physical domains and to cost-effectively enhance the reliability and resilience of CPSs. Here a review of CPT elements, broken down into physical components (simulators, emulators, and physical hardware), soft components (communication protocols, network timing protocols), and user interfaces (visualization-dashboard design considerations) is presented. Various methods used to validate CPS performance are reviewed and evaluated for potential applications in CPT performance validation. Last, initial simulated results for a CPT design, based on the IEEE 33 bus system, are presented, along with a brief discussion on how model-based testing and fault–injection-based testing (using scaling and ramp-type attacks) may be used to help validate CPT performance.

14 SOLAR ENERGY↗

Artificial Intelligence Techniques in Smart Grid: A Survey

The smart grid is enabling the collection of massive amounts of high-dimensional and multi-type data about the electric power grid operations, by integrating advanced metering infrastructure, control technologies, and communication technologies. However, the traditional modeling, optimization, and control technologies have many limitations in processing the data; thus, the applications of artificial intelligence (AI) techniques in the smart grid are becoming more apparent. This survey presents a structured review of the existing research into some common AI techniques applied to load forecasting, power grid stability assessment, faults detection, and security problems in the smart grid and power systems. It also provides further research challenges for applying AI technologies to realize truly smart grid systems. Finally, this survey presents opportunities of applying AI to smart grid problems. The paper concludes that the applications of AI techniques can enhance and improve the reliability and resilience of smart grid systems.

energy systems↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems: Preprint

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. In this paper, a holistic impulse-based MOV lifetime estimation framework is proposed. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗