Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Attenuation of wall disturbances in an electron cyclotron resonance oxygen–argon plasma using real time control

Present practice in plasma-assisted semiconductor manufacturing specifies recipes in terms of inputs such as gas flow rates, power and pressure. However, ostensibly identical chambers running identical recipes may produce very different results. Extensive chamber matching, i.e., initial iterative, empirical tuning of the process recipe, which entails time-consuming, ex situ statistical analysis of process metrics such as etch depth, uniformity, anisotropy and selectivity, is required to ensure acceptable results. Once matched, chambers are run open loop and are thus sensitive to disturbances such as actuator drift, wall seasoning and substrate loading, which may impact negatively on process reproducibility. An alternative approach, which may obviate the need for chamber matching and reduce the sensitivity of process metrics to exogenous disturbances, would be to specify a recipe in terms of quantities such as active species densities, and to regulate these in real time by adjusting the inputs with a suitable control algorithm. In this work, real time control of an electron cyclotron resonance O{sub 2}/Ar plasma used for photoresist ashing has been implemented. The design of elementary, model-based algorithms for the control of the argon 750 and oxygen 844 line intensities measured by optical emission spectroscopy is described. Fluorination of the chamber walls by means of an SF{sub 6} plasma prior to ashing inhibits wall recombination of oxygen radicals resulting in an approximately 20% increase in ash rate in the open loop case. However, closed loop control almost completely attenuates the effect of fluorination, thus demonstrating the efficacy of the control algorithms in ensuring a reproducible ash rate in the face of a wall disturbance.

42 ENGINEERING↗

Experimental validation of advanced regulations for superconducting magnet cooling undergoing periodic heat loads

Superconducting magnets used in tokamaks undergo periodic heat load caused by cycling plasma operations inducing AC losses, neutrons fluxes and eddy currents in magnet structures. In the cryogenic system of JT60-SA tokamak, the Auxiliary Cold Box (ACB) distributes helium from the refrigerator to the cryogenic users and in particular to the superconducting magnets. ACB comprises a saturated helium bath with immersed heat exchangers, extracting heat from independent cooling loops. The supercritical helium flow in each cooling loop is driven by a cold circulator. In order to safely operate the refrigerator during plasma pulses, the interface between the ACB and the refrigerator shall be as stable as possible, with well-balanced bath inlet and outlet mass flows during cycling operation. The solution presented in this paper relies on a combination of regulations to smooth pulsed heat loads and to keep a constant refrigeration power during all the cycle. Two smoothing strategies are presented, both regulating the outlet mass flow of the bath: the first one using the bath as a thermal buffer and the second one storing energy in the loop by varying the cold circulator speed. The bath outlet mass flow is also controlled by an immersed resistive heater which enables a constant evaporation rate in the bath when power coming from the loops is decreasing. The refrigeration power is controlled so that the compensating power remains within an acceptable margin. Experimental validation is achieved using the HELIOS facility. This facility running at CEA Grenoble since 2010 is a scaled down model of the ACB bath and Central Solenoid magnet cooling loop of the JT60-SA tokamak. Test results show performances and robustness of the regulations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DNN-based policies for stochastic AC OPF

We report a prominent challenge to the safe and optimal operation of the modern power grid arises due to growing uncertainties in loads and renewables. Stochastic optimal power flow (SOPF) formulations provide a mechanism to handle these uncertainties by computing dispatch decisions and control policies that maintain feasibility under uncertainty. Most SOPF formulations consider simple control policies such as affine policies that are mathematically simple and resemble many policies used in current practice. Motivated by the efficacy of machine learning (ML) algorithms and the potential benefits of general control policies for cost and constraint enforcement, we put forth a deep neural network (DNN)-based policy that predicts the generator dispatch decisions in real time in response to uncertainty. The weights of the DNN are learnt using stochastic primal–dual updates that solve the SOPF without the need for prior generation of training labels and can explicitly account for the feasibility constraints in the SOPF. The advantages of the DNN policy over simpler policies and their efficacy in enforcing safety limits and producing near optimal solutions are demonstrated in the context of a chance constrained formulation on a number of test cases.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

A Relaxed PV Bus Model in Linear Power Flow

The emerging multimodal active energy resource units make it necessary to introduce constant voltage amplitude buses (PV bus) in the operation of modern distribution systems. To enable the analysis of PV bus using linear power flow models, this letter proposes a relaxed PV bus model for solving power flow related problems using an indirect modeling approach. The developed PV bus model can be applied to linear power flow models in both rectangular and polar coordinates. Besides, the approximation error of the relaxed PV bus model can also be controlled and quantified. Lastly, the proposed relaxed PV bus model is validated using different test systems. According to the numerical studies, the maximum error on the PV bus approximation in all case studies is only 0.61%, and the maximum error of the supporting power at the PV buses is 6.5%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The effect of solidity on the performance of H-rotor Darrieus turbine

Utilization of wind energy has been investigated for a long period of time by different researchers in different ways. Out of which, the Horizontal Axis Wind Turbine and the Vertical Axis Wind Turbine have now advanced design, but still there is scope to improve their efficiency. The Vertical Axis Wind Turbine (VAWT) has the advantage over Horizontal Axis Wind Turbine (HAWT) for working on omnidirectional air flow without any extra control system. A modified H-rotor Darrieus type VAWT is analysed in this paper, which is a lift based wind turbine. The effect of solidity (i.e. chord length, no. of blades) on power coefficient (C{sub P}) of H-rotor for different tip speed ratios is numerically investigated. The study is conducted using time dependent RANS equations using SST k-ω model. SIMPLE scheme is used as pressure-velocity coupling and in all cases, the second order upwind discretization scheme is chosen for getting more accurate solution. In results, different parameters are compared, which depict the performance of the modified H-rotor Darrieus type VAWT. Double layered H-rotor having inner layer blades with longer chord gives higher power coefficient than those have inner layer blades with smaller chord.

17 WIND ENERGY↗

Trace Element Mass Flow Rates from U.S. Coal Fired Power Plants

Trace elements (TEs) exit coal-fired power plants (CFPPs) via solid, liquid, and gaseous waste streams. Estimating the TE concentrations of these waste streams is essential to selecting pollution controls and estimating emission reduction benefits. Our report presents a generalizable mass balance model for estimating TE mass flow rates in CFPP waste streams and evaluates model accuracy for the U.S. coal fleet given current data constraints. We stochastically estimate, using a bootstrapping approach, the 2015 plant-level mass flow rates of Hg, Se, As, and Cl to solid, liquid, and gas phase waste streams by combining publicly available data for combusted coal TE concentrations with estimates of TE partitioning within installed air pollution control processes. When compared with measured and reported data on TE mass flow rates, this model generally overestimates masses by 30–50%, with larger errors for Hg. The partitioning estimates are consistent for Se, As, and Cl removal from flue gas, but tend to underestimate Hg removal. While our model is suitable for first-order estimates of TE mass flows, future work to enhance model performance should focus on collecting and using new data on TE concentrations in the coal blend, where data quality is the weakest.

01 COAL, LIGNITE, AND PEAT↗

Wind plant wake losses: Disconnect between turbine actuation and control of plant wakes with engineering wake models

Wake losses from neighboring plants may become a major factor in wind plant design and control as additional plants are constructed in areas with high wind resource availability. Because plant wakes span a large range of physical scales, from turbine rotor diameter to tens of kilometers, it is unclear whether conventional wake models or turbine control strategies are effective at the plant scale. Wake steering and axial induction control are evaluated in the current work as means of reducing the impact of neighboring wind plants on power and levelized cost of electricity. FLOw Redirection and Induction in Steady State (FLORIS) simulations were performed with the Gauss–Curl Hybrid and TurbOPark wake models as well as two operation and maintenance models to investigate control setpoint sensitivity to wake representation and economic factors. Both wake models estimate losses across a range of atmospheric conditions, although the wake loss magnitude is dependent on the wake model. Annual energy production and levelized cost of electricity are driven by wind direction frequency, with frequently aligned plants experiencing the greatest losses. However, both wake steering and axial induction are unable to mitigate the impact of upstream plants. Wake steering is constrained by plant geometry, since wake displacement is much less than the plant wake width, while axial induction requires curtailing the majority of turbines in upstream plants. Individual turbine strategies are limited by their effective scale and model representation. New wake models that include plant-scale physics are needed to facilitate the design of effective plant wake control strategies.

Scott, Ryan (ORCID:0000000328107574)↗

Field Validation of Wake Steering Control with Wind Direction Variability: Preprint

Wake steering is a type of wind farm control strategy wherein upstream turbines are misaligned with the wind direction to redirect their wakes away from downstream turbines, increasing overall wind plant power. Wake steering is often analyzed assuming steady mean wind directions across the wind farm. However, in practice, the wind direction varies considerably over time because of large-scale weather phenomena. Wind direction variability causes wake steering controllers to increase power production less than predicted by steady state models, but more robust wake steering strategies can be designed that account for variable wind conditions. This paper compares the achieved yaw offsets and power gains from two 2-turbine wake steering experiments at a commercial wind farm with model predictions using the FLOw Redirection and Induction in Steady State (FLORIS) control-oriented model, assuming both fixed and variable wind directions. The impact of wind direction variability is modeled by including wind direction and yaw uncertainty in the FLORIS calculations. The field results match the trends predicted assuming wind direction variability. Specifically, the yaw offsets achieved in the intended control regions are lower than desired, resulting in less power gain, while a slight loss in power occurs for wind directions outside of the intended control region because of unintentional yaw misalignment. The agreement between the model and field results suggests that the wind direction variability model can be used to design wake steering controllers that are more robust to variable wind conditions present in the field.

17 WIND ENERGY↗

Evaluation of the potential for wake steering for U.S. land-based wind power plants

The wind power plant-wide control strategy known as wake steering involves the misalignment of upstream turbines with the wind direction to deflect wakes away from downstream turbines, increasing net wind plant power production. In this paper, we evaluate the potential of wake steering for U.S. land-based wind power plants. First, we outline a method for simulating and optimizing wake steering control for existing wind plants by combining the flow redirection and induction in steady state wake steering engineering model with the U.S. Wind Turbine Database and Wind Integration National Dataset Toolkit wind resource dataset. Next, to better understand the potential benefits of wake steering beyond those for existing wind plants, we evaluate the relative impacts of turbine specific power, turbine spacing, and mean wind speed on energy gain and levelized cost of energy (LCOE) using a model land-based wind power plant. For a subset of 60 existing wind plants, assuming a constant turbulence intensity of 8%, wake steering was found to yield an average annual energy production (AEP) gain of 0.80%, equivalent to recovering 13.85% of baseline wake losses. Further, we present a linear approximation between baseline wake losses and AEP gains that can be used to estimate wake steering gains for other wind power plants. Highlighting additional benefits of wake steering, for the model wind power plant we found that energy gains from wake steering enabled an approximate 30% reduction in turbine spacing while keeping LCOE constant.

17 WIND ENERGY↗

Dissociation and excitation coefficients of nitrogen molecules and nitrogen monoxide generation

The excitation coefficient α{sub N2} is calculated for the excited metastable level of N{sub 2}(A{sub 3}Σ{sub u}{sup +}) in nitrogen molecules. In addition, the dissociation coefficient of nitrogen molecules is investigated by making use of the Boltzmann distribution of the electrons in atmospheric plasmas. The excitation and electron-impact dissociation coefficients of nitrogen molecules are analytically expressed in terms of the electron temperature T{sub e} for evaluations of the reactive oxygen and nitrogen species in atmospheric plasmas. As an application example of these coefficients, the nitrogen monoxide generation through a microwave torch is carried out for a development of medical tool. The nitrogen monoxide concentration from a microwave plasma-torch can be easily controlled by the nitrogen flow rate, mole fraction of the oxygen gas, and the microwave power. A simple analytic expression of the nitrogen monoxide concentration is obtained in terms of the oxygen molecular density and gas flow rate. The experimental data agree remarkably well with the theoretical results from the analytical expression. A microwave nitrogen-torch can easily provide an appropriate nitrogen monoxide concentration for the wound healings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Playas Grid Reliability and Distributed Energy Research

The future looks bright for solar and renewable energies in the United States. Recent studies claim that by 2050, solar power could supply a third of all electricity demand in the country’s western states. Technology advances, soft policy changes, and increased energy consciousness will all have to happen to achieve this goal. The New Mexico Institute of Mining and Technology (NMT) and the Department of Homeland Security (DHS) perform various training and research activities at this site. Given its unique nature, Playas was chosen to test Micro-Grids and other examples of renewable distributed energy resources (DER). Several proposed distributed energy sources (DERs) were not implemented as planned including the Micro-Grid. However, Micro-Grid design and computer modeling were completed and these results are included in this report. As part of this research, four PV (solar) generating systems were installed with remote Internet based communication and control capabilities. These systems have been integrated into and can interact with the local grid So that (for example) excess power produced by the solar arrays can be exported to the utility grid. Energy efficient LED lighting was installed in several buildings to further reduce consumption of utility-supplied power. By combining reduced lighting costs; lowering HVAC loads; and installing smart PV generating equipment with energy storage (battery banks) these systems can greatly reduce electrical usage drawn from an older rural electrical cooperative (Co-Op) while providing clean dependable power. Several additional tasks under this project involved conducting research to develop methods of producing electricity from organic materials (i.e. biofuels, biomass. etc.), the most successful being the biodiesel reactor. Improvements with Proton Exchange Membranes (PEM) for fuels cells were demonstrated and advances in Dye Sensitized Solar Cells (DSSC) were also shown. The specific goals of the project include: 1) Instrumentation of the power distribution system with distributed energy resources, demand-side control and intelligent homes within the town of Playas, NM, 2) Creation of models (power flow and dynamic) of the Playas power distribution system, 3) Validation of the models through comparison of predicted behavior to data collected from instrumentation, and 4) Utilization of the models and test grid to characterize the impact of new devices and approaches (e.g., distributed generation and load management) on the local distribution system as well as the grid at large. In addition to the above stated objectives, the research also focused on three critical challenges facing renewable distributed energy platforms: 1) hydrogen from biomass, 2) improved catalyst support systems for electrolysis membranes and fuel cell systems, and 3) improved manufacturing methodologies of low cost photovoltaics. The following sections describe activities performed during this project. The various tasks were focused on establishing Playas as a “…theoretical and experimental test bed…” through which components of a modern/smart grid could be characterized. On a broader scale, project efforts were aimed at development of tools and gathering of experience/expertise that would accelerate progress toward implementation of a modern grid.

09 BIOMASS FUELS↗

Evaluation of Power Fluidic Pumping Technology for Molten Salt Reactor Applications

Power Fluidics™ (PF) is a NuVision Engineering proprietary technology which uses gases to control the flow of other fluids in industrial applications. This unique technology has several advantages over traditional centrifugal pumps. Molten salt nuclear reactors and associated systems have unique fluid handling demands. This report explores the applicability of PF to molten salt systems. Several potential applications are identified, necessary modifications of existing PF technology for salt service are discussed, and a path for development and demonstration is proposed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrical system for pulse-width modulated control of a power inverter using phase-shifted carrier signals and related operating methods

Systems and methods are provided for pulse-width modulated control of power inverter using phase-shifted carrier signals. An electrical system comprises an energy source and a motor. The motor has a first set of windings and a second set of windings, which are electrically isolated from each other. An inverter module is coupled between the energy source and the motor and comprises a first set of phase legs coupled to the first set of windings and a second set of phase legs coupled to the second set of windings. A controller is coupled to the inverter module and is configured to achieve a desired power flow between the energy source and the motor by modulating the first set of phase legs using a first carrier signal and modulating the second set of phase legs using a second carrier signal. The second carrier signal is phase-shifted relative to the first carrier signal.

47 OTHER INSTRUMENTATION↗

Columbia River Treaty 2014/2024 Review • Phase 1 Report

Under the Columbia River Treaty (Treaty or CRT) of 1964, Canada and the United States (U.S.) jointly regulate and manage the Columbia River as it flows from British Columbia into the U.S. The Treaty has provided substantial flood control and power generation benefits to both nations. The Treaty established Canadian and U.S. Entities as implementing agents for each government. British Columbia Hydro and Power Authority (BC Hydro) was designated as the Canadian Entity. The Bonneville Power Administration (BPA) Administrator and the U.S. Army Corps of Engineers (Corps) Division Engineer, Northwestern Division, were designated as the U.S. Entity. The Canadian and U.S. Entities are empowered by their respective governments with broad discretion to implement the existing Columbia River Treaty. They are not, however, authorized to terminate, renegotiate, or otherwise modify the Treaty. In the U.S., authority over international treaties rests with the President, assisted in foreign relations and international negotiations by the Department of State and subject in certain cases to the advice and consent of the U.S. Senate. In Canada, international treaties are within the prerogative of the executive branch of the federal government. Under current policy, treaties are tabled in the House of Commons, and are subject to a waiting period before the executive branch brings the treaty into effect. In the case of the Columbia River Treaty, Canada has assigned certain rights and obligations relating to the Treaty to British Columbia pursuant to the Canada-B.C. Agreement. The Phase 1 report is provided to those respective governmental bodies to support possible independent and/or joint decisions that may be made with respect to the future of the Treaty. The Treaty contains two important provisions that take effect on and after September 16, 2024, that could impact the current power and flood control benefits: 1. Canadian flood control obligations automatically change from a pre-determined annual operation to a “Called Upon” operation. 2. The year 2024 is the earliest date that either Canada or the U.S. can terminate most of the provisions of the Treaty, with a minimum 10-years advance written notice. Hence, September 16, 2014, is the latest date that either nation could provide notice of intent to terminate and still have the termination effective at its earliest possible date in 2024. While termination would end most Treaty obligations, Called Upon flood control and Libby coordination provisions will continue regardless of termination. However, it is important to note that the Treaty has no end date and absent either country using the termination option will continue indefinitely.

Columbia River Treaty, Canada, United States, Brit↗

Thermoelectric power generator for variable thermal power source

Traditional power generation systems using thermoelectric power generators are designed to operate most efficiently for a single operating condition. The present invention provides a power generation system in which the characteristics of the thermoelectrics, the flow of the thermal power, and the operational characteristics of the power generator are monitored and controlled such that higher operation efficiencies and/or higher output powers can be maintained with variably thermal power input. Such a system is particularly beneficial in variable thermal power source systems, such as recovering power from the waste heat generated in the exhaust of combustion engines.

30 DIRECT ENERGY CONVERSION↗

Design and dynamic modeling of a printed circuit heat exchanger for the next generation nuclear plant

Printed circuit heat exchangers (PCHEs) are promising to be adopted in the design of the Next Generation Nuclear Plant (NGNP). A PCHE serves as an intermediate heat exchanger (IHX) to isolate the secondary loop from the reactor's primary system. The overall plant thermal efficiency relies on the PCHE performance and the reactor safety could be affected by the PCHE performance. It is therefore imperative to be able to accurately model PCHE's performance under various conditions. The aim of this study is to design an IHX-type PCHE for a reference NGNP design and conduct both steady-state and transient simulations for the designed PCHE. A countercurrent configuration and straight-channel geometry were adopted for the PCHE design and the classic log-mean temperature difference (LMTD) method was utilized to size the PCHE for the required thermal duty. A mathematical model was numerically solved to predict the steady-state and transient behavior of the PCHE. The steady-state temperature distributions of the fluids on the hot and cold sides and in the solid plates of the heat exchanger were initially obtained by dividing the PCHE into 1,000 segments along the flow direction, and were served as the initial condition for the transient simulations. A series of transient scenarios, including inlet temperature step changes, mass flow rate step changes, and inlet temperature step changes combined with mass flow step changes, were simulated and analyzed to examine the dynamic performance of the designed PCHE. The numerical results appear reasonable and it is evident that the dynamic model has the capability of predicting both steady-state and transient performance of the straight-channel PCHE. In addition, the numerical results could provide some insights for developing control strategies for PCHEs as IHXs in the NGNP. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗