Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

TIMED Doppler Interferometer

The Timed Doppler Interferometer (TIDI) will accurately and precisely determine the global vector MLTI (Mesosphere and Lower Thermosphere) wind, temperature, and density profiles. It will measure characteristics of the gravity wave and planetary wave spectra. The tidal characteristics of temperature, density, and wind in the MLTI will be determined. The neutral and ion winds will be measured to characterize the electrodynamical behavior of the MLTI. Oxygen and O2 abundances and nocticulent cloud activity will be measured. This review goes into the calibration and error sources, optical design, mechanisms design, detector design, electronics design, microprocessor and flight software design, and quality assurance and parts.

Killeen, Timothy L.↗

Autonomous Assembly of Modular Structures in Space and on Extraterrestrial Locations

The fulfillment of the new US. National Vision for Space Exploration requires many new enabling technologies to accomplish the goal of utilizing space for commercial activities and for returning humans to the moon and extraterrestrial environments. Traditionally, flight structures are manufactured as complete systems and require humans to complete the integration and assembly in orbit. These structures are bulky and require the use of heavy launch vehicles to send the units to the desired location, e.g. International Space Station (ISS). This method requires a high degree of safety, numerous space walks and significant cost for the humans to perform the assembly in orbit. For example, for assembly and maintenance of the ISS, 52 Extravehicular Activities (EVA's) have been performed so far with a total EVA time of approximately 322 hours. Sixteen (16) shuttle flights haw been to the ISS to perform these activities with an approximate cost of $450M per mission. For future space missions, costs have to be reduced to reasonably achieve the exploration goals. One concept that has been proposed is the autonomous assembly of space structures. This concept is an affordable, reliable solution to in-space and extraterrestrial assembly operations. Assembly is autonomously performed when two components containing onboard electronics join after recognizing that the joint is appropriate and in the precise position and orientation required for assembly. The mechanism only activates when the specifications are correct and m a nominal range. After assembly, local sensors and electronics monitor the integrity of the joint for feedback to a master controller. To achieve this concept will require a shift in the methods for designing space structures. In addition, innovative techniques will be required to perform the assembly autonomously. Monitoring of the assembled joint will be necessary for safety and structural integrity. If a very large structure is to be assembled in orbit, then the number of integrity sensors will be significant. Thus simple, low cost sensors are integral to the success of this concept. This paper will address these issues and will propose a novel concept for assembling space structures autonomously. The paper will present Several autonomous assembly methods. Core technologies required to achieve in space assembly will be discussed and novel techniques for communicating, sensing, docking and assembly will be detailed. These core technologies are critical to the goal of utilizing space in a cost efficient and safe manner. Finally, these technologies can also be applied to other systems both on earth and extraterrestrial environments.

Alhorn, Dean C.↗

MeV Scale Physics in MicroBooNE

This thesis presents the reconstruction and measurement of low-energy electromagnetic activity with beam neutrino interactions within the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC). LArTPCs have proven to be excellent detectors to measure neutrino interaction cross sections and are being used to perform precision measurements of neutrino oscillation parameters. The work presented in this thesis has demonstrated unprecedentedly low, sub-MeV energy thresholds that have increased sensitivity of LArTPCs to detect neutrino interactions from core collapse supernovae and Muon Decay at Rest (µDAR). In addition, such low thresholds have also increased measurement sensitivity for interactions from Beyond the Standard Model (BSM) candidates such as millicharged particles and nuclear and electron recoils from dark matter candidate particles. On the reconstruction side, this work has established an energy resolution of 6.3% for electromagnetic activity i the 0-5 MeV energy range within the MicroBooNE LArTPC. Additionally this work presents the quantitative analysis of the low-energy activity emanating from G-10 support ribs in MicroBooNE and discusses how such activity could be a problematic source of background for low-energy physics analyses in future neutrino detectors such as the Deep Underground Neutrino Experiment (DUNE).

Bhat, Avinay↗

Interstellar scintillation and ultra-low-frequency gravitational wave observations

High precision pulsar timing measurements have been used to set upper limits on the flux of ultralong period (T greater than 3 years) stochastic gravitational waves. The data used to produce the current limits appear to be limited by timing noise that is intrinsic to the pulsars. Recently, however, there have been very low noise timing observations of the 1.5-millisecond pulsar. This suggests that significant sensitivity improvements in searches for ultralow frequency (ULF) gravitational waves may be possible. Here, the effects of the heretofore secondary noise source of phase scintillations caused by interstellar electron density fluctuations are calculated, and the prospects for improved ULF gravitational wave measurements using pulsar timing are discussed.

Armstrong, J. W.↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Printed Microscopic Universal Gradient Interface for Super Stretchable Strain‐Insensitive Bioelectronics

Abstract Stretchable electronics capable of conforming to nonplanar and dynamic human body surfaces are central for creating implantable and on‐skin devices for high‐fidelity monitoring of diverse physiological signals. While various strategies have been developed to produce stretchable devices, the signals collected from such devices are often highly sensitive to local strain, resulting in inevitable convolution with surface strain‐induced motion artifacts that are difficult to distinguish from intrinsic physiological signals. Here all‐printed super stretchable strain‐insensitive bioelectronics using a unique universal gradient interface (UGI) are reported to bridge the gap between soft biomaterials and stiff electronic materials. Leveraging a versatile aerosol‐based multi‐materials printing technique that allows precise spatial control over the local stiffnesses with submicron resolution, the UGI enables strain‐insensitive electronic devices with negligible resistivity changes under a 180% uniaxial stretch ratio. Various stretchable devices are directly printed on the UGI for on‐skin health monitoring with high signal quality and near‐perfect immunity to motion artifacts, including semiconductor‐based photodetectors for sensing blood oxygen saturation levels and metal‐based temperature sensors. The concept in this work will significantly simplify the fabrication and accelerate the development of a broad range of wearable and implantable bioelectronics for real‐time health monitoring and personalized therapeutics.

Song, Kaidong [Department of Aerospace and Mechani↗

Automated High‐Throughput Fatigue Testing of Freestanding Thin Films

Abstract Mechanical testing at small length scales has traditionally been resource‐intensive due to difficulties with meticulous sample preparation, exacting load alignments, and precision measurements. Microscale fatigue testing can be particularly challenging due to the time‐intensive, tedious repetition of single fatigue experiments. To mitigate these challenges, this work presents a new methodology for the high‐throughput fatigue testing of thin films at the microscale. This methodology features a microelectromechanical systems‐based Si carrier that can support the simultaneous and independent fatigue testing of an array of samples. To demonstrate this new technique, the microscale fatigue behavior of nanocrystalline Al is efficiently characterized via this Si carrier and automated fatigue testing with in situ scanning electron microscopy. This methodology reduces the total testing time by an order of magnitude, and the high‐throughput fatigue results highlight the stochastic nature of the microscale fatigue response. This manuscript also discusses how this initial capability can be adapted to accommodate more samples, different materials, new geometries, and other loading modes.

Barrios, Alejandro↗

Collective Thomson scattering measurement of plasma evolution during the current pulse in a laser-triggered switch

High-voltage laser-triggered switches (HV-LTSs) are used in pulsed-power applications where low jitter and precise timing are required. The switches allow operation in the megaampere, megavolt regime while maintaining low insertion losses. Currently, there is a lack of detailed plasma measurements in these switches, yet such measurements are needed to elucidate the detailed physics, which include a range of processes such as laser breakdown, streamer formation and growth, current flow, plasma evolution, and cooling. Detailed spatially- and temporally resolved measurements of plasma properties within the switches could contribute to validating and advancing numeric models of these systems. This contribution presents laser Thomson scattering measurements of the electron number density and temperature evolution in a HV-LTS. The switch was operated at 6 kV with current flow for a duration of 145 ns and a peak current density of 0.2 MA/cm2 into a matched load. The Thomson scattering diagnostic system uses a 532 nm probe from an Nd:YAG laser allowing a temporal resolution of ∼10 ns. We find that during the switch current pulse, the plasma electron temperature rose from a starting value of 8.1 ± 1.6 eV (due to cooling of the earlier trigger laser plasma) to a peak value of 26 ± 5 eV with an associated increase in the electron density from 8.6 ± 1.7 × 1017 to 3.1 ± 0.6 × 1018 cm−3.

Gottfried, Jacob A. (ORCID:0000000290058841)↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

Digital atomic scale fabrication an inverse Moore's Law – A path to atomically precise manufacturing

There is an exciting opportunity to start a second digital revolution that will supersede the first digital revolution in information technology (IT) as the primary driver of scientific, technological, and economic growth. This new revolution will be digital fabrication technology. Here, the digital IT revolution has been largely driven by digital algorithms such as error detection and correction and Moore's Law which has given us an exponential trend in product capabilities. However, the longstanding trend in improving manufacturing precision which has enabled Moore's Law simply cannot be continued much longer because we are running into the limits imposed by the quantized nature of matter. At this scale, matter can no longer be treated in an analogue fashion i.e. as an infinitely divisible medium, but must be treated as an integer number of discrete atomic distances, i.e. in a digital fashion. By embracing this digital nature of matter, we can conceive of a digital fabrication technology, where the digital processes are the making and breaking of chemical bonds, there is a digital address grid that is spatial in nature, and error detection and correction processes can be developed. This digital fabrication technology will have the similarly huge advantages over analog fabrication that digital IT has over analog IT. We remind the reader that effective digital technologies are not exclusively digital in their operation. Digital electronics is carried out by analog transistors that are embedded in circuitry designed to accept their output in a digital fashion. Digital fabrication technology is not synonymous with Atomically Precise Manufacturing (APM) but should lead to that important capability. Furthermore this digital fabrication technology will start a new exponential manufacturing trend that will replace Moore's law and will not be just for information processing and therefore will have an even larger impact than Moore's Law. Like any exponential trend Digital Fabrication will start slowly in a few niche markets, but the time for investing in the development of this new technology is now.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deep residual networks for crystallography trained on synthetic data

The use of artificial intelligence to process diffraction images is challenged by the need to assemble large and precisely designed training data sets. To address this, a codebase called Resonet was developed for synthesizing diffraction data and training residual neural networks on these data. Here, two per-pattern capabilities of Resonet are demonstrated: (i) interpretation of crystal resolution and (ii) identification of overlapping lattices. Resonet was tested across a compilation of diffraction images from synchrotron experiments and X-ray free-electron laser experiments. Crucially, these models readily execute on graphics processing units and can thus significantly outperform conventional algorithms. While Resonet is currently utilized to provide real-time feedback for macromolecular crystallography users at the Stanford Synchrotron Radiation Lightsource, its simple Python-based interface makes it easy to embed in other processing frameworks. This work highlights the utility of physics-based simulation for training deep neural networks and lays the groundwork for the development of additional models to enhance diffraction collection and analysis.

36 MATERIALS SCIENCE↗

Unusual layer-by-layer growth of epitaxial oxide islands during Cu oxidation

Elucidating metal oxide growth mechanisms is essential for precisely designing and fabricating nanostructured oxides with broad applications in energy and electronics. However, current epitaxial oxide growth methods are based on macroscopic empirical knowledge, lacking fundamental guidance at the nanoscale. Using correlated in situ environmental transmission electron microscopy, statistically-validated quantitative analysis, and density functional theory calculations, we show epitaxial Cu 2 O nano-island growth on Cu is layer-by-layer along Cu 2 O(110) planes, regardless of substrate orientation, contradicting classical models that predict multi-layer growth parallel to substrate surfaces. Growth kinetics show cubic relationships with time, indicating individual oxide monolayers follow Frank-van der Merwe growth whereas oxide islands follow Stranski-Krastanov growth. Cu sources for island growth transition from step edges to bulk substrates during oxidation, contrasting with classical corrosion theories which assume subsurface sources predominate. Our results resolve alternative epitaxial island growth mechanisms, improving the understanding of oxidation dynamics critical for advanced manufacturing at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders

The anomalies in the high voltage converter modulator (HVCM) remain a major down time for the spallation neutron source facility, that delivers the most intense neutron beam in the world for scientific materials research. In this work, we propose neural network architectures based on Recurrent AutoEncoders (RAE) to detect anomalies ahead of time in the power signals coming from the HVCM. Bi-directional gated recurrent unit, bi-directional long-short term memory (LSTM), and convolutional LSTM (ConvLSTM) are developed, trained, and tested using real experimental signals from the HVCM module. The results show a good performance of the proposed RAE models, achieving precision up to 91%, recall up to 88%, false omission rate as low as 20% (i.e. 80% of the anomalies were detected), and area under the ROC curve up to 0.9. The three RAE models provide very comparable performance, with LSTM showing slightly better performance than GRU and ConvLSTM. The RAE models are benchmarked against other anomaly detection methods, including isolation forest, support vector machine, local outlier factor, feedforward and convolutional autoencoders, and others; showing a better performance. Here, the results of this study demonstrate the promising potential of RAE in anomaly detection for real-world power systems, and for increasing the reliability of the HVCM modules in the spallation neutron source.

42 ENGINEERING↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗

Comments on the paper “Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the Electron-Ion Collider” (Part I)

A critical review of the methodology used in F. Rathmann et al., Phys. Rev. Accel. Beams 29, 021001 (2026), to evaluate beam-induced depolarization of the Atomic Polarized Hydrogen Gas Jet (HJET) target at the Electron–Ion Collider (EIC) is presented. It is shown that several key assumptions underlying that analysis—including the introduction of a photon emission threshold, the application of Fermi’s Golden Rule to coherent hyperfine transitions, the interpretation of power broadening as a physical linewidth increase, and the treatment of spatial magnetic fields—are either incorrect or internally inconsistent. As a consequence, the predicted large depolarization effects are demonstrated to be artifacts of the adopted methodology rather than genuine physical phenomena. A consistent quantum-mechanical treatment based on the time-dependent Schrödinger equation shows that beam-induced depolarization probabilities at the EIC are negligibly small.

43 PARTICLE ACCELERATORS↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Ultrafast all-optical coherence of molecular electron spins in room-temperature water solution

The tunability and spatial precision of paramagnetic molecules makes them attractive for quantum sensing. However, usual microwave-based detection methods have poor temporal and spatial resolution, and optical methods compatible with room-temperature solutions have remained elusive. In this study, we utilized pump-probe polarization spectroscopy to initialize and track electron spin coherence in a molecule. Designed to efficiently couple spins to light, aqueous potassium hexachloroiridate(IV) enabled detection of few-picosecond free-induction decay at room temperature and micromolar concentrations. Viscosity was found to strongly vary decoherence lifetimes. This approach has improved the experimental time resolution by up to five orders of magnitude, making it possible to observe molecular electron spin coherence in a system that only exhibits coherence below 25 kelvin with traditional techniques.

74 ATOMIC AND MOLECULAR PHYSICS↗