Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Reducing Radiation Damage Using Pulsed Electron Beams in the TEM

A rise in the development and the use of ultrashort-pulsed sources (i.e., femtosecond to picosecond) in transmission electron microscopes (TEMs) has led to numerous discoveries and paradigm tests of atomic to nanoscale structural dynamics well beyond the temporal limits of fast detectors. Vital to these advances are precise control over the electron emission process, typically via the photoelectric effect, or via temporal modulation of an initially continuous beam swept across an aperture. In addition to enabling ultrafast pump-probe experiments, fine control over the emission process allows for exploration of the effects of such pulsed beams on damage sustained by the specimen during observation. Unlike proposed diffract-before-destroy methods with electrons, these approaches would ideally be applied in the single-electron-per-packet regime, with sufficient time between the arrival of each electron at the specimen for all reversible energy-deposition events to fully recover. Indeed, some intriguing results using pulsed electron beams in TEMs have been reported here, including effects on the structure of catalyst particles and apparent prolonged exposures for polymer crystals

61 RADIATION PROTECTION AND DOSIMETRY↗

CryoTransformer: a transformer model for picking protein particles from Cryo-EM micrographs

Cryo-electron microscopy (cryo-EM) is a powerful technique for determining the structures of large protein complexes. Picking single protein particles from cryo-EM micrographs (images) is a crucial step in reconstructing protein structures from them. However, the widely used template-based particle picking process requires some manual particle picking and is labor-intensive and time-consuming. Though machine learning and artificial intelligence (AI) can potentially automate particle picking, the current AI methods pick particles with low precision or low recall. The erroneously picked particles can severely reduce the quality of reconstructed protein structures, especially for the micrographs with low signal-to-noise-ratio (SNR).

59 BASIC BIOLOGICAL SCIENCES↗

Rationally Engineered Vertically Aligned β ‐Ga 2− x W x O 3 Nanocomposites for Self‐Biased Solar‐Blind Ultraviolet Photodetectors with Ultrafast Response

Abstract With the astonishing advancement of present technology and increasing energy consumption, there is an ever‐increasing demand for energy‐efficient multifunctional sensors or transducers based on low‐cost, eco‐friendly material systems. In this context, self‐assembled vertically aligned β ‐Ga 2− x W x O 3 nanocomposite (GWO‐VAN) architecture‐assisted self‐biased solar‐blind UV photodetection on a silicon platform, which is the heart of traditional electronics is presented. Utilizing precisely controlled growth parameters, the formation of W‐enriched vertical β ‐Ga 2− x W x O 3 nanocolumns embedded into the W‐deficient β ‐Ga 2− x W x O 3 matrix is reached. Detailed structural and morphological analyses evidently confirm the presence of β ‐Ga 2− x W x O 3 nanocomposite with a high structural and chemical quality. Furthermore, absorption and photoluminescence spectroscopy explains photo‐absorption dynamics and the recombination through possible donor–acceptor energy states. The proposed GWO‐VAN framework facilitates evenly dispersed nanoregions with asymmetric donor energy state distribution and thus forms build‐in potential at the vertical β ‐Ga 2− x W x O 3 interfaces. As a result, the overall heterostructure evinces photovoltaic nature under the UV irradiation. A responsivity of ≈30 A/W is observed with an ultrafast response time (≈350 µs) under transient triggering conditions. Corresponding detectivity and external quantum efficiency are 7.9 × 10 12 Jones and 1.4 × 10 4 %, respectively. It is believed that, while this is the first report exploiting GWO‐VAN architecture to manifest self‐biased solar‐blind UV photodetection, the implication of the approach is enormous in designing electronics for extreme environment functionality and has immense potential to demonstrate drastic improvement in low‐cost UV photodetector technology.

Das, Debabrata↗

Absolute position measurement in a gas time projection chamber via transverse diffusion of drift charge

Time Projection Chambers (TPCs) with charge readout via micro pattern gaseous detectors can provide detailed measurements of charge density distributions. We here report on measurements of alpha particle tracks, using a TPC where the drift charge is amplified with Gas Electron Multipliers and detected with a pixel ASIC. We find that by measuring the 3-D topology of drift charge and fitting for its transverse diffusion, we obtain the absolute position of tracks in the drift direction. For example, we obtain a precision of 1~cm for 1~cm-long alpha track segments. To our knowledge this is the first demonstration of such a measurement in a gas TPC. This technique has several attractive features: it does not require knowledge of the initial specific ionization, is robust against bias from diffuse charge below detection threshold, and is also robust against high charge densities that saturate the detector response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray beam monitoring and wavelength calibration using four-beam diffraction

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cyber-Attack Identification of Synchrophasor Data Via VMD and Multifusion SVM

A large amount of synchrophasor data in the wide area measurement system (WAMS) needs to be collected and transmitted to the phasor data concentrator, thereby increasing the possibility of being attacked by hackers. The attacked data are therefore hidden into the normal synchrophasor data so that the synchrophasor data based application will be affected. To remedy this problem, an identification framework is proposed to detect the data cyber-attack in WAMS utilizing variational mode decomposition (VMD) and multifusion support vector machine (MSVM). First, VMD is used to transform the attacked data into multiple modal components. Thereafter, a novel MSVM is employed to classify the deterministic features using the proposed linear combined multikernel (LCM). Further, this LCM can fuse multiple types of features, including the time, frequency, and statistical domains of the synchrophasor data. Utilizing the actual data from FNET/GridEye, different experiments are conducted under multiple attack strengths and types. The results demonstrate that the identification framework has higher precision and robustness compared with other conventional classifiers.

97 MATHEMATICS AND COMPUTING↗

Comments on Zihang Zhu, Shanghong Zhao, Xuan Li, and Kun Qu, Tao Lin, “Photonic generation of frequency-octupled microwave signal with reduced electrical local oscillator power and improved spectrum purity” Opt. Quant. Electron (2017)

In the title paper, Zhu et al. presented a technique for generating filter less frequency octo-tupling signal based on a cascade of two dual-polarization modulators. Firstly, the harmonics of order 4l (l in an integer) are generated in the x-polarization by driving the x-modulators with an RF signal with a 90° phase difference between the two stages. Then the carrier is suppressed using unmodulated y-polarization by means of polarization multiplexing. Accordingly, the demerit of their design is the requirement to reset a precise polarizer angle to suppress the optical carrier every time there is a change in the RF drive amplitude or the modulation index. Nevertheless, the authors claim superior performance to a similar architecture in which the y-branch is modulated with the proper RF drive phases to suppress the carrier for all drive levels with no need to adjust a splitting ratio. The aim of this comment is to show that by modulating the y-polarization with adjusted RF drive phases, same architecture can be used to perform frequency octo-tupling whose performance is neither limited by precise settings of the polarizer angle nor by the proper settings of the modulation index. The carrier is suppressed for a unique value of the polarizer angle for all modulation index. If the modulation index is adjusted to suppress the 4th harmonics, same circuit can be used to perform frequency 24-tupling generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel experimental system for the KDK measurement of the 40 K decay scheme relevant for rare event searches

Potassium-40 ( 40 K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. 40 K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpretingcertain results or can lead to lack of precision depending on the field and analysis technique. Additionally, the KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited 40 K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr 2 I 5 :Eu scintillator as source and detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed Element Microparticle Characterization by Electron Probe Microanalysis

Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.

Riche, Alexis T. (ORCID:0009000121978126)↗

High Pressure Gas Filled RF Cavity Beam Test at the Fermilab MuCool Test Area

The high energy physics community is continually looking to push the limits with respect to the energy and luminosity of particle accelerators. In the realm of leptons, only electron colliders have been built to date. Compared to hadrons, electrons lose a large amount of energy when accelerated in a ring through synchrotron radiation. A solution to this problem is to build long, straight accelerators for electrons, which has been done with great success. With a new generation of lepton colliders being conceived, building longer, more powerful accelerators is not the most enticing option. Muons have been proposed as an alternative particle to electrons. Muons lose less energy to synchrotron radiation and a Muon Collider can provide luminosity within a much smaller energy range than a comparable electron collider. This allows a circular collider to be built with higher attainable energy than any present electron collider. As part of the accelerator, but separate from the collider, it would also be possible to allow the muons to decay to study neutrinos. The possibility of a high energy, high luminosity muon collider and an abundant, precise source of neutrinos is an attractive one. The technological challenges of building a muon accelerator are many and diverse. Because the muon is an unstable particle, a muon beam must be cooled and accelerated to the desired energy within a short amount of time. This requirement places strict requisites on the type of acceleration and focusing that can be used. Muons are generated as tertiary beams with a huge phase space, so strong magnetic fields are required to capture and focus them. Radio frequency (RF) cavities are needed to capture, bunch and accelerate the muons. Unfortunately, traditional vacuum RF cavities have been shown to break down in the magnetic fields necessary for capture and focusing.

43 PARTICLE ACCELERATORS↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing Efficient Catalysts through Bimetallic Architecture: Rh@Pt Nanocubes as a Case Study

Bimetallic nanocatalysts often have increased activities and stabilities over their monometallic counterparts due to surface strain effects and electron transfer between the two metals. We demonstrate that the performance of a nanocatalyst can be precisely manipulated in shape-controlled nanocrystals through a bimetallic core@shell architecture. This ability is achieved in a model core@shell Rh@Pt nanocube system through control of shell thickness. The enhanced performance with thin-shelled nanocrystals is correlated with the weakening of surface–adsorbate interactions. In these thin-shelled Rh@Pt nanocubes, the maximum current density achieved during formic acid oxidation was over 2 times greater than that achieved with similarly sized Pt nanocubes, with a decreased CO poisoning ratio as well. Finally, the strategy employed here should also enhance the performance of many other bimetallic nanomaterials composed of more cost-effective metals too.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional machining of carbon nanotube forests using water-assisted scanning electron microscope processing

We demonstrate that vertically aligned carbon nanotubes (CNTs) can be precisely machined in a low pressure water vapor ambient using the electron beam of an environmental scanning electron microscope. The electron beam locally damages the irradiated regions of the CNT forest and also dissociates the water vapor molecules into reactive species including hydroxyl radicals. These species then locally oxidize the damaged region of the CNTs. The technique offers material removal capabilities ranging from selected CNTs to hundreds of cubic microns. We study how the material removal rate is influenced by the acceleration voltage, beam current, dwell time, operating pressure, and CNT orientation. Milled cuts with depths between 0–100 microns are generated, corresponding to a material removal rate of up to 20.1 μm{sup 3}/min. The technique produces little carbon residue and does not disturb the native morphology of the CNT network. Finally, we demonstrate direct machining of pyramidal surfaces and re-entrant cuts to create freestanding geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision calculation of the strange nucleon electromagnetic form factors

We report a direct lattice QCD calculation of the strange nucleon electromagnetic form factors G s E and G s M in the kinematic range 0 ≤ Q 2 ≤ 1.2GeV 2 . For the first time, both G s E and G s M are shown to be nonzero with high significance. This work uses closer-to-physical lattice parameters than previous calculations, and achieves an unprecented statistical precision by implementing a recently proposed variance reduction technique called hierarchical probing . We perform model-independent fits of the form factor shapes using the z-expansion and determine the strange electric and magnetic radii and magnetic moment. As a result, we compare our results to parity-violating electron-proton scattering data and to other theoretical studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mu2e Tracker

The Mu2e experiment will search for neutrinoless conversion of muons into electrons In the field of an aluminum nucleus. The signature of this process is an electron with energy nearly equal to the muon mass. Precise and robust measurement of the outgoing electron momentum, combined with other background rejection methods, is essential to the experiment. We rely on a low-mass straw tube tracker to achieve these goals. The tracking system must operate in a vacuum and a 1 Tesla magnetic field. We have chosen to use about 20,000 thin-wall Mylar straws held under tension to avoid the need for support within the active volume. In addition to measuring the distance from the wire by drift time, subnanosecond measurement of signal propagation time will be used to measure position along the wire. The charge will be measured using ADCs to provide particle identification capability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-J-45: Sparing Normal Tissue with Ultra-High Dose Rate in Radiation Therapy

Purpose: To spare normal tissue by reducing the location uncertainty of a moving target, we proposed an ultra-high dose rate system and evaluated. Methods: High energy electrons generated with a linear accelerator were injected into a storage ring to be accumulated. The number of the electrons in the ring was determined based on the prescribed radiation dose. The dose was delivered within a millisecond, when an online imaging system found that the target was in the position that was consistent with that in a treatment plan. In such a short time period, the displacement of the target was negligible. The margin added to the clinical target volume (CTV) could be reduced that was evaluated by comparing of volumes between CTV and ITV in 14 cases of lung stereotactic body radiation therapy (SBRT) treatments. A design of the ultra-high dose rate system was evaluated based clinical needs and the recent developments of low energy (a few MeV) electron storage ring. Results: This design of ultra-high dose rate system was feasible based on the techniques currently available. The reduction of a target volume was significant by reducing the margin that accounted the motion of the target. ∼50% volume reduction of the internal target volume (ITV) could be achieved in lung SBRT treatments. Conclusion: With this innovation of ultra-high dose rate system, the margin of target is able to be significantly reduced. It will reduce treatment time of gating and allow precisely specified gating window to improve the accuracy of dose delivering.

60 APPLIED LIFE SCIENCES↗