Relief Valve Opens And Closes Quickly

Relief valve opens quickly to relieve excess pressure and closes quickly when pressure drops slightly below relief pressure. O-ring exposes one or more ports under high pressure, releasing excess pressurized fluid. Adjusting screw used to change compression on Belleville-spring washers and to set pressure at which valve opens. Designed for use aboard Space Shuttle to vent pressurized hydrazine to vacuum, valve concept useful in industrial applications where rapid opening, rapid closing, or low susceptibility to blockage by vented fluid required.

Svejkovsky, Paul A.↗

A numerical analysis of the effects of conjugate heat transfer, vapor compressibility, and viscous dissipation in heat pipes

The effects of conjugate heat transfer, vapor compressibility, and viscous dissipation in heat pipes are discussed. The accuracy of the partially parabolic versus the elliptic presentation of the governing equations is also examined. The results show that the axial wall conduction has a tendency to make the temperature distribution more uniform for heat pipes with large ratios of pipe wall to effective liquid-wick thermal conductivity. The compressible and incompressible models show very close agreement for the total pressure drop, while the local pressure variations along the heat pipe are quite different for these two models when the radial Reynolds number at the interface is high.

Faghri, Amir↗

Support of gas flowmeter upgrade

A project history review, literature review, and vendor search were conducted to identify a flowmeter that would improve the accuracy of gaseous flow measurements in the White Sands Test Facility (WSTF) Calibration Laboratory and the Hydrogen High Flow Facility. Both facilities currently use sonic flow nozzles to measure flowrates. The flow nozzle pressure drops combined with corresponding pressure and temperature measurements have been estimated to produce uncertainties in flowrate measurements of 2 to 5 percent. This study investigated the state of flowmeter technology to make recommendations that would reduce those uncertainties. Most flowmeters measure velocity and volume, therefore mass flow measurement must be calculated based on additional pressures and temperature measurement which contribute to the error. The two exceptions are thermal dispersion meters and Coriolis mass flowmeters. The thermal dispersion meters are accurate to 1 to 5 percent. The Coriolis meters are significantly more accurate, at least for liquids. For gases, there is evidence they may be accurate to within 0.5 percent or better of the flowrate, but there may be limitations due to inappropriate velocity, pressure, Mach number and vibration disturbances. In this report, a comparison of flowmeters is presented. Candidate Coriolis meters and a methodology to qualify the meter with tests both at WSTF and Southwest Research Institute are recommended and outlined.

Waugaman, Dennis↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument, requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in a folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system, and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable to support the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid one. The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121C was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The tests provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has been carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable of supporting the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid on The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121 deg Celcius was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The test provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has be carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗

Development and Characterization Testing of an Air Pulsation Valve for a Pulse Detonation Engine Supersonic Parametric Inlet Test Section

In pulse detonation engines, the potential exists for gas pulses from the combustor to travel upstream and adversely affect the inlet performance of the engine. In order to determine the effect of these high frequency pulses on the inlet performance, an air pulsation valve was developed to provide air pulses downstream of a supersonic parametric inlet test section. The purpose of this report is to document the design and characterization tests that were performed on a pulsation valve that was tested at the NASA Glenn Research Center 1x1 Supersonic Wind Tunnel (SWT) test facility. The high air flow pulsation valve design philosophy and analyses performed are discussed and characterization test results are presented. The pulsation valve model was devised based on the concept of using a free spinning ball valve driven from a variable speed electric motor to generate air flow pulses at preset frequencies. In order to deliver the proper flow rate, the flow port was contoured to maximize flow rate and minimize pressure drop. To obtain sharp pressure spikes the valve flow port was designed to be as narrow as possible to minimize port dwell time.

Tornabene, Robert↗

Experimental Results of Performance Tests on a Four-Port Wave Rotor

A series of tests has been performed on a four-port wave rotor suitable for use as a topping stage on a gas turbine engine, to measure the overall pressure ratio obtainable as a function of temperature ratio, inlet mass flow, loop flow ratio, and rotor speed. The wave rotor employed an open high pressure loop that is the high pressure inlet flow was not the air exhausted from the high pressure outlet, but was obtained from a separate heated source, although the mass flow rates of the two flows were balanced. This permitted the choice of a range of loop-flow ratios (i.e., ratio of high pressure flow to low pressure flow), as well as the possibility of examining the effect of mass flow imbalance. Imbalance could occur as a result of leakage or deliberate bleeding for cooling air. Measurements of the pressure drop in the high pressure loop were also obtained. A pressure ratio of 1.17 was obtained at a temperature ratio of 2.0, with an inlet mass flow of 0.6 lb/s. Earlier tests had given a pressure ratio of less than 1.12. The improvement was due to improved sealing between the high pressure and low pressure loops, and a modification to the movable end-wall which is provided to allow for rotor expansion.

Wilson, John↗

Cavitation Effects on the Structural Dynamics of Turbomachinery Components

The structural integrity of inducer and impeller blades in rocket engine turbomachinery must be evaluated in the face of complex excitation mechanisms including fluctuating pressures due to cavitation. Cavitation occurs when the local fluid pressure drops below the vapor pressure, causing the formation of vapor-filled bubbles. Cavitation can exist to various extents within the typical operating range of rocket engine turbopumps. Despite recent progress towards reducing uncertainties in structural dynamic models of turbomachinery components, the extent to which pump cavitation affects the structural dynamic properties (i.e., natural frequencies, damping, and mode shapes) of inducer and impeller blades remains largely unknown. To study the structural dynamic effects of cavitating flows, experiments are conducted in a high-speed water tunnel. The test articles mimic a single inducer blade that is unwrapped from the hub, thus resembling a low aspect ratio cantilevered plate. To induce cavitation, the plates are oriented at a non-zero angle of attack and have rough strips near their leading edges. To control the extent of cavitation, the static pressure of the water tunnel is controlled between roughly 0.5 and 1.5 atm. A high-speed camera is used to quantify the coverage of the cavitations heet. The sheet coverage is then correlated to changes in fluid-added mass and hydroelstic damping. In addition, a corresponding two-way coupled CFD/FE model is under development for test/analysis correlation.

Ben Davis↗

Cavitation Effects on the Structural Dynamics of Turbomachinery Components

The structural integrity of inducer and impeller blades in rocket engine turbomachinery must be evaluated in the face of complex excitation mechanisms including fluctuating pressures due to cavitation. Cavitation occurs when the local fluid pressure drops below the vapor pressure, causing the formation of vapor-filled bubbles. Cavitation can exist to various extents within the typical operating range of rocket engine turbopumps. Despite recent progress towards reducing uncertainties in structural dynamic models of turbomachinery components, the extent to which pump cavitation affects the structural dynamic properties (i.e., natural frequencies, damping, and mode shapes) of inducer and impeller blades remains largely unknown. To study the structural dynamic effects of cavitating flows, experiments are conducted in a high-speed water tunnel. The test article is a low aspect ratio cantilevered plate, thus mimicing a single inducer blade that is unwrapped from its hub. The test article is oriented at zero angle of attack and has a triangular trip at its leading edge to induce cavitation. To change the extent of cavitation, the static pressure of the water tunnel is controlled. A high-speed camera is used to quantify the coverage of the cavitation sheet.

Fluid-Structure Interaction↗

A New Method for Predicting Turbulent Flow Reattachment Location: Application of Stratford Criterion for Reattaching Flows

A new method for predicting turbulent flow reattachment location has been developed. The method predicts the reattachment location using the surface static pressure distribution and requires only a single empirical parameter. The method is based on the well-known Stratford’s flow separation criterion, which results from an approximate solution to the equations of motion within the boundary layer. Because of the large pressure rise, the original Stratford separation criterion is not valid for reattaching flows. In order to apply the Stratford criterion for reattaching flows, the reference location was moved to the pressure drop conditions instead of pressure rise conditions. In addition, the pressure distribution was scaled using a technique that was originally introduced for supersonic base flows. A new empirical parameter was also obtained for the modified Stratford criterion. The method has been tested for 30 different separated flow configurations from the literature. The variety of test cases include subsonic flows, transonic flows, 2D flows, and axisymmetric flows, with experimental as well as high resolution numerical simulation results. The flow reattachment predictions with the new method agree very well with the reported data. The error is less than 5% and typically about 2%. The new method is an extremely simple and a quick way of finding the reattachment location. Given the complexities of the existing experimental techniques for finding the reattachment location, the method easily and quickly provides the flow reattachment location, which could be used to estimate the physical extent of separation bubbles, as a performance index for flow control methods, or to assess the predictive capability of turbulence models.

Flow reattachment location↗

Cavitation Effects on the Structural Dynamics of Turbomachinery Components

The structural integrity of inducer and impeller blades in rocket engine turbo machinery must be evaluated in the face of complex excitation mechanisms including fluctuating pressures due to cavitation. Cavitation occurs when the local fluid pressure drops below the vapor pressure, causing the formation of vapor-filled bubbles. Cavitation can exist to various extents within the typical operating range of rocket engine turbo pumps. Despite recent progress towards reducing uncertainties in structural dynamic models of turbo machinery components, the extent to which pump cavitation affects the structural dynamic properties (i.e., natural frequencies, damping, and mode shapes) of inducer and impeller blades remains largely unknown. To study the structural dynamic effects of cavitating flows, experiments are conducted in a high-speed water tunnel. The test article is a low aspect ratio cantilevered plate, thus mimicing a single inducer blade that is unwrapped from its hub. The test article is oriented at zero angle of attack and has a triangular trip at its leading edge to induce cavitation. To change the extent of cavitation, the static pressure of the water tunnel is controlled. A high-speed camera is used to quantify the coverage of the cavitation sheet.

Structural Dynamics↗

Combustion Stability Characteristics of the Project Morpheus Liquid Oxygen/Liquid Methane Main Engine

The Project Morpheus liquid oxygen (LOX) / liquid methane rocket engines demonstrated acousticcoupled combustion instabilities during sea‐level ground‐based testing at the NASA Johnson Space Center (JSC) and Stennis Space Center (SSC). High‐amplitude, 1T, 1R, 1T1R (and higher order) modes appear to be triggered by injector conditions. The instability occurred during the Morpheus‐specific engine ignition/start sequence, and did demonstrate the capability to propagate into mainstage. However, the instability was never observed to initiate during mainstage, even at low power levels. The Morpheus main engine is a JSC‐designed ~5,000 lbf‐thrust, 4:1 throttling, pressure‐fed cryogenic engine using an impinging element injector design. Two different engine designs, named HD4 and HD5, and two different builds of the HD4 engine all demonstrated similar instability characteristics. Through the analysis of more than 200 hot fire tests on the Morpheus vehicle and SSC test stand, a relationship between ignition stability and injector/chamber pressure was developed. The instability has the distinct characteristic of initiating at high relative injection pressure drop (dP) at low chamber pressure (Pc); i.e., instabilities initiated at high dP/Pc at low Pc during the start sequence. The high dP/Pc during start results during the injector /chamber chill‐in, and is enhanced by hydraulic flip in the injector orifice elements. Because of the fixed mixture ratio of the existing engine design (the main valves share a common actuator), it is not currently possible to determine if LOX or methane injector dP/Pc were individual contributors (i.e., LOX and methane dP/Pc typically trend in the same direction within a given test). The instability demonstrated initiation characteristic of starting at or shortly after methane injector chillin. Colder methane (e.g., sub‐cooled) at the injector inlet prior to engine start was much more likely to result in an instability. A secondary effect of LOX sub‐cooling was also possibly observed; greater LOX sub‐ cooling improved stability. Some tests demonstrated a low‐amplitude 1L‐1T instability prior to LOX injector chill‐in. The Morpheus main engine also demonstrated chug instabilities during some engine shutdown sequences on the flight vehicle and SSC test stand. The chug instability was also infrequently observed during the startup sequence. The chug instabilities predictably initiated at low dP/Pc at low Pc. The chug instabilities were always self‐limiting; startup chug instabilities terminated during throttle‐up and shutdown chug instabilities decayed by shutdown termination.

Melcher, J. C.↗

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

Distribution and observed associations of orthostatic blood pressure changes in elderly general medicine outpatients

Factors associated with orthostatic blood pressure change in elderly outpatients were determined by surveying 398 medical clinical outpatients aged 65 years and older. Blood pressure was measured with random-zero sphygmomanometers after patients were 5 minutes in a supine and 5 minutes in a standing position. Orthostatic blood pressure changes were at normally distributed levels with systolic and diastolic pressures dropping an average of 4 mm Hg (standard deviation [SD]=15 mm Hg) and 2 mm Hg (SD=11 mm Hg), respectively. Orthostatic blood pressure changes were unassociated with age, race, sex, body mass, time since eating, symptoms, or other factors. According to multiple linear regression analysis, supine systolic pressure, chronic obstructive pulmonary disease (COPD), and diabetes mellitus were associated with a decrease in systolic pressure on standing. Hypertension, antiarthritic drugs, and abnormal heartbeat were associated with an increase in systolic pressure on standing. For orthostatic diastolic pressure changes, supine diastolic pressure and COPD were associated with a decrease in diastolic pressure on standing. Congestive heart failure was associated with an increase in standing diastolic pressure. Using logistic regression analysis, only supine systolic pressure was associated with a greater than 20-mm Hg drop in systolic pressure (n=53, prevalence=13%). Supine diastolic pressure and COPD were the only variables associated with a greater than 20-mm Hg drop in diastolic pressure (n=16, prevalence=4%). These factors may help physicians in identifying older persons at risk for having orthostatic hypotension.

Non-NASA Center↗

Remotely operated high pressure valve protects test personnel

High pressure valve used in testing certain spacecraft systems is safely opened and closed by a remotely stationed operator. The valve is self-regulating in that if the incoming pressure drops below a desired value the valve will automatically close, warning the operator that the testing pressure has dropped to an undesired level.

Howland, B. T.↗