Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Prospective, Open-Label, Multicenter Phase 2 Trial of Neoadjuvant Therapy Using Full-Dose Gemcitabine and S-1 Concurrent with Radiation for Resectable Pancreatic Ductal Adenocarcinoma

Background: Neoadjuvant therapy reportedly shows only marginal clinical benefit in pancreatic ductal adenocarcinoma (PDAC), especially in resectable cases. However, with more effective regimens, neoadjuvant therapy may become a standard of care for resectable cases. A prospective, open-label, multicenter phases 1 and 2 trial of neoadjuvant therapy was conducted using full-dose gemcitabine and S-1 concurrently with 50.4 Gy of radiation therapy (GSRT) for resectable PDAC. This report describes the phase 2 results. Methods: The phase 2 part of this study enrolled 57 patients with cytologically or histologically proven PDAC deemed resectable based on imaging before neoadjuvant therapy. These patients received GSRT. After reevaluation by computed tomography scan, surgical exploration was performed, followed by adjuvant therapy. According to the prescribed protocol of the clinical trial, statistical analyses included 57 phase 2 patients and 6 phase 1 patients who received the same dosage as in phase 2. Results: This trial enrolled 63 patients (42 men and 21 women) with a median age of 70 years. Leukopenia or neutropenia of grade 3 or higher occurred for 79% of the patients, but no other severe adverse events were observed. Among the 63 patients, 54 underwent surgical resection. Intention-to-treat analysis of the 63 patients showed an excellent median survival time lasting as long as 55.3 months. The patients who completed neoadjuvant therapy, surgery, and adjuvant therapy had a 5-year survival rate of 56.6%. Conclusions: This regimen showed outstanding clinical efficacy with acceptable tolerability for patients with resectable PDAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A transcriptome software comparison for the analyses of treatments expected to give subtle gene expression responses

Background: In this comparative study we evaluate the performance of four software tools: DNAstar-D (DESeq2), DNAstar-E (edgeR), CLC Genomics and Partek Flow for identification of differentially expressed genes (DEGs) using a transcriptome of E. coli. The RNA-seq data are from the effect of below-background radiation 5.5 nGy total dose (0.2nGy/hr) on E. coli grown shielded from natural radiation 655 m below ground in a pre-World War II steel vault. The gene expression response to three supplemented sources of radiation designed to mimic natural background, 1952 – 5720 nGy in total dose (71–208 nGy/hr), are compared to this “radiation-deprived” treatment. In addition, RNA-seq data of Caenorhabditis elegans nematode from similar radiation treatments was analyzed by three of the software packages. Results: In E. coli, the four software programs identified one of the supplementary sources of radiation (KCl) to evoke about 5 times more transcribed genes than the minus-radiation treatment (69–114 differentially expressed genes, DEGs), and so the rest of the analyses used this KCl vs “Minus” comparison. After imposing a 30-read minimum cutoff, one of the DNAStar options shared two of the three steps (mapping, normalization, and statistic) with Partek Flow (they both used median of ratios to normalize and the DESeq2 statistical package), and these two programs identified the highest number of DEGs in common with each other (53). In contrast, when the programs used different approaches in each of the three steps, between 31 and 40 DEGs were found in common. Regarding the extent of expression differences, three of the four programs gave high fold-change results (15–178 fold), but one (DNAstar’s DESeq2) resulted in more conservative fold-changes (1.5–3.5). In a parallel study comparing three qPCR commercial validation software programs, these programs also gave variable results as to which genes were significantly regulated. Similarly, the C. elegans analysis showed exaggerated fold-changes in CLC and DNAstar’s edgeR while DNAstar-D was more conservative. Conclusions: Regarding the extent of expression (fold-change), and considering the subtlety of the very low level radiation treatments, in E. coli three of the four programs gave what we consider exaggerated fold-change results (15 – 178 fold), but one (DNAstar’s DESeq2) gave more realistic fold-changes (1.5–3.5). When RT-qPCR validation comparisons to transcriptome results were carried out, they supported the more conservative DNAstar-D’s expression results. When another model organism’s (nematode) response to these radiation differences was similarly analyzed, DNAstar-D also resulted in the most conservative expression patterns. Therefore, we would propose DESeq2 (“DNAstar-D”) as an appropriate software tool for differential gene expression studies for treatments expected to give subtle transcriptome responses.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Histone Deacetylase Inhibitors as Radiosensitizers for Proton and Light Ion Radiotherapy

Significant opportunities remain for pharmacologically enhancing the clinical effectiveness of proton and carbon ion-based radiotherapies to achieve both tumor cell radiosensitization and normal tissue radioprotection. We investigated whether pretreatment with the hydroxamate-based histone deacetylase inhibitors (HDACi) SAHA (vorinostat), M344, and PTACH impacts radiation-induced DNA double-strand break (DSB) induction and repair, cell killing, and transformation (acquisition of anchorage-independent growth in soft agar) in human normal and tumor cell lines following gamma ray and light ion irradiation. Treatment of normal NFF28 primary fibroblasts and U2OS osteosarcoma, A549 lung carcinoma, and U87MG glioma cells with 5–10 µM HDACi concentrations 18 h prior to cesium-137 gamma irradiation resulted in radiosensitization measured by clonogenic survival assays and increased levels of colocalized gamma-H2AX/53BP1 foci induction. We similarly tested these HDACi following irradiation with 200 MeV protons, 290 MeV/n carbon ions, and 350 MeV/n oxygen ions delivered in the Bragg plateau region. Unlike uniform gamma ray radiosensitization, effects of HDACi pretreatment were unexpectedly cell type and ion species-dependent with C-12 and O-16 ion irradiations showing enhanced G0/G1-phase fibroblast survival (radioprotection) and in some cases reduced or absent tumor cell radiosensitization. DSB-associated foci levels were similar for proton-irradiated DMSO control and SAHA-treated fibroblast cultures, while lower levels of induced foci were observed in SAHA-pretreated C-12 ion-irradiated fibroblasts. Fibroblast transformation frequencies measured for all radiation types were generally LET-dependent and lowest following proton irradiation; however, both gamma and proton exposures showed hyperlinear transformation induction at low doses (≤25 cGy). HDACi pretreatments led to overall lower transformation frequencies at low doses for all radiation types except O-16 ions but generally led to higher transformation frequencies at higher doses (>50 cGy). The results of these in vitro studies cast doubt on the clinical efficacy of using HDACi as radiosensitizers for light ion-based hadron radiotherapy given the mixed results on their radiosensitization effectiveness and related possibility of increased second cancer induction.

59 BASIC BIOLOGICAL SCIENCES↗

MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature

Here, the aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the measurement of a lepton–lepton electroweak reaction (MOLLER) experiment in experimental Hall A at Jefferson Lab, Newport News, VA. In this article, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the short-beam shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils, tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well-suited for electrical insulation of MOLLER magnets.

36 MATERIALS SCIENCE↗

A bespoke health risk assessment methodology for the radiation protection of astronauts

An alternative approach that is particularly suitable for the radiation health risk assessment (HRA) of astronauts is presented. The quantity, Radiation Attributed Decrease of Survival (RADS), representing the cumulative decrease in the unknown survival curve at a certain attained age, due to the radiation exposure at an earlier age, forms the basis for this alternative approach. Results are provided for all solid cancer plus leukemia incidence RADS from estimated doses from theoretical radiation exposures accumulated during long-term missions to the Moon or Mars. For example, it is shown that a 1000-day Mars exploration mission with a hypothetical mission effective dose of 1.07 Sv at typical astronaut ages around 40 years old, will result in the probability of surviving free of all types of solid cancer and leukemia until retirement age (65 years) being reduced by 4.2% (95% CI 3.2; 5.3) for males and 5.8% (95% CI 4.8; 7.0) for females. RADS dose–responses are given, for the outcomes for incidence of all solid cancer, leukemia, lung and female breast cancer. Results showing how RADS varies with age at exposure, attained age and other factors are also presented. The advantages of this alternative approach, over currently applied methodologies for the long-term radiation protection of astronauts after mission exposures, are presented with example calculations applicable to European astronaut occupational HRA. Some tentative suggestions for new types of occupational risk limits for space missions are given while acknowledging that the setting of astronaut radiation-related risk limits will ultimately be decided by the Space Agencies. Suggestions are provided for further work which builds on and extends this new HRA approach, e.g., by eventually including non-cancer effects and detailed space dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

2025 Review and Revision of Federal Guidance Report 15

Federal Guidance Report No. 15 (FGR 15), External Exposure to Radionuclides in Air, Water and Soil, published in 2019 and referred to below as FGR 2019, provides age-specific effective dose rate coefficients for reference persons externally exposed to each of 1252 radionuclides homogenously distributed in environmental media. Soon after completion of FGR 2019, the International Commission on Radiological Protection (ICRP) published a similar report (ICRP Publication 144, 2020) addressing the same radionuclides and many of the external exposure scenarios addressed in FGR 2019. In 2023 Argonne National Laboratory (ANL) published a review of dose coefficients in FGR 2019, concluding that “The external effective dose from beta radiation is not appropriately accounted for in FGR 15 for both low- and high-energy beta emitters in air, in soil, and on soil surfaces.” That conclusion was based largely on comparisons of dose coefficients in FGR 2019 with values in ICRP Publication 144 but also on consideration of some unexpected patterns of equivalent dose rate coefficients across tissues and of effective dose rate coefficients across different soil depths, for a selected set of low-energy beta emitters. In response to the ANL report, the Center for Radiation Protection Knowledge (CRPK) at Oak Ridge National Laboratory (ORNL) performed an extensive reexamination of the methods and published values of FGR 2019. CRPK found that coding errors had resulted in inaccurate estimates, primarily overestimates, in many of the dose coefficients tabulated in FGR 2019 but that many of the differences between results in FGR 2019 and ICRP Publication 144 could be traced to differences in methodology. CRPK has corrected all errors in FGR 2019 associated with the coding errors and has taken the opportunity to improve a major portion of the remaining dose coefficients in FGR 2019, primarily through additional Monte Carlo calculations resulting in improved statistics for tissue equivalent dose rate coefficients for exposure to monoenergetic sources. This has eliminated the need for extrapolation of results from high and medium energies to low energies, as was done in FGR 2019. In addition, inconsistencies in the methodology identified in the review, such as computational representation of the adult female, were eliminated. The revised effective dose rate coefficients are consistent with values in ICRP Publication 144 except for differences in values clearly arising from differences in methodology; and differences in values for a relatively small set of very low-energy radionuclides with highly uncertain dose coefficients regardless of methodology.

54 ENVIRONMENTAL SCIENCES↗

The effects of dose, dose rate, and irradiation type and their equivalence on radiation-induced segregation in binary alloy systems via phase-field simulations

Radiation-induced segregation is a phenomenon commonly observed in many alloys which consists of the redistribution of elements (solute or interstitial impurities) under irradiation. The onset and development of radiation-induced segregation can only occur when a sufficient flux of defects is sustained and defect sinks are present. Irradiation dose, dose rate, and particle types all affect defect flux. In this work, we employ a phase-field model to examine the effects of dose, dose rate, and type of incident particles on radiation-induced segregation behavior in a model binary alloy. The phase-field model takes into account the formation and evolution of point defects as well as defect clusters, the diffusion and clustering of alloy species, the presence of additional extrinsic defect sinks in the form of dislocations, and two different methods of radiation-damage insertion, which are intended to simulate either light-ion/electron irradiation via Frenkel pairs or heavy-ion irradiation in the form of cascades. Our results show a dose-rate and particle-type dependence on the amount of solute segregation. We show that the material systems exposed to higher dose rates are less subjected to solute segregation at equivalent doses. We also show that such dose-rate-dependence behavior is due to a delay of the incubation dose at which radiation-induced segregation effectively starts. Particle type and the presence of dislocations can accentuate this behavior. Our model predictions correlate with many experimental observations made over the years on radiation-induced segregation providing credence to the simulation results. The methodology presented in this study allows for a first-order prediction of the dose rate at which proxy irradiation experiments could be performed to approximate radiation-induced segregation behaviors seen in targeted irradiation conditions.

36 MATERIALS SCIENCE↗

Effect of radiation exposure on survival after first solid cancer diagnosis in A-bomb survivors

Comparison of the estimated effect of atomic bomb radiation exposure on solid cancer incidence and solid cancer mortality in the RERF Life Span Study (LSS) reveals a difference in the magnitude and shape of the excess relative risk dose response. A possible contributing factor to this difference is pre-diagnosis radiation effect on post-diagnosis survival. Pre-diagnosis radiation exposure theoretically could influence post-diagnosis survival by affecting the genetic makeup and possibly aggressiveness of cancer, or by compromising tolerance for aggressive treatment for cancer. We analyze the radiation effect on post-diagnosis survival in 20,463 LSS subjects diagnosed with first-primary solid cancer between 1958 and 2009 with particular attention to whether death was caused by the first-primary cancer, other cancer, or non-cancer diseases. From multivariable Cox regression analysis of cause-specific survival, the excess hazard at 1 Gy (EH 1Gy ) for death from the first primary cancer was not significantly different from zero – p = 0.23, EH 1Gy = 0.038 (95 % CI: –0.023, 0.104). Death from other cancer and death from non-cancer diseases both were significantly associated with radiation dose: other cancer EH 1Gy = 0.38 (95 % CI: 0.24, 0.53); non-cancer EH 1Gy = 0.24 (95 % CI: 0.13, 0.36), both p < 0.001. There is no detectable large effect of pre-diagnosis radiation exposure on post-diagnosis death from the first primary cancer in A-bomb survivors. A direct effect of pre-diagnosis radiation exposure on cancer prognosis is ruled out as an explanation for the difference in incidence and mortality dose response in A-bomb survivors.

60 APPLIED LIFE SCIENCES↗

Uncertainty Analysis of Consequence Management Data Products

An interlaboratory effort has developed a probabilistic framework to characterize uncertainty in data products that are developed by the US Department of Energy Consequence Management Program in support of the Federal Radiological Monitoring and Assessment Center. The purpose of this paper is to provide an overview of the probability distributions of input variables and the statistical methods used to propagate and quantify the overall uncertainty of the derived response levels that are used as contours on data products due to the uncertainty in input parameters. Uncertainty analysis results are also presented for several study scenarios. This paper includes an example data product to illustrate the potential real-world implications of incorporating uncertainty analysis results into data products that inform protective action decisions. Data product contours that indicate areas where public protection actions may be warranted can be customized to an acceptable level of uncertainty. Finally, the investigators seek feedback from decision makers and the radiological emergency response community to determine how uncertainty information can be used to support the protective action decision-making process and how it can be presented on data products.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Auto-Segmentation to Reduce Contouring and Dose Inconsistency in Clinical Trials: The Simulated Impact on RTOG 0617

Contouring inconsistencies are known but understudied in clinical radiation therapy trials. We applied auto-contouring to the Radiation Therapy Oncology Group (RTOG) 0617 dose escalation trial data. We hypothesized that the trial heart doses were higher than reported due to inconsistent and insufficient heart segmentation. We tested our hypothesis by comparing doses between deep-learning (DL) segmented hearts and trial hearts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deciphering the Dynamic Molecular Program of Radiation-Induced Endothelial Senescence

Radiation-induced cellular senescence is a double-edged sword, acting as both a tumor suppression process limiting tumor proliferation, and a crucial process contributing to normal tissue injury. Endothelial cells play a role in normal tissue injury after radiation therapy. Recently, a study observed an accumulation of senescent endothelial cells (ECs) around radiation-induced lung focal lesions following stereotactic radiation injury in mice. However, the effect of radiation on EC senescence remains unclear because it depends on dose and fractionation, and because the senescent phenotype is heterogeneous and dynamic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-dependent structural and electron-density features in the lytic polysaccharide monooxygenase NcAA9D

Structural studies of copper-containing lytic polysaccharide monooxygenases (LPMOs) by X-ray crystallography are often complicated by radiation damage. In this study, we analyze a series of 36 X-ray crystal structures of NcAA9D, a Neurospora crassa AA9-family LPMO, determined from data collected at cryogenic temperature from a single crystal to investigate the progressive effects of radiation damage at the active site of this enzyme. We report new insights into the dose-dependence of active-site geometry in LPMOs and utilize the unique pre-bound dioxygen site of NcAA9D to analyze the impact of X-ray dose on the electron density of this species. It is well established that photoreduction of the LPMO active-site copper(II) leads to expulsion of its water ligands. We further characterize this displacement and the corresponding electron-density smearing, a phenomenon that can lead to the erroneous modeling of copper-bound dioxygen species. These findings suggest that radiation-dose series collected from a single crystal provide invaluable data to support unambiguous assignment of radiation-sensitive intermediates at the active site of LPMOs and other radiation-sensitive redox enzymes.

Miller, Samuel [ORNL] (ORCID:0009000459491817)↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Unraveling radiation damage and healing mechanisms in halide perovskites using energy-tuned dual irradiation dosing

Perovskite photovoltaics have been shown to recover, or heal, after radiation damage. Here, we deconvolve the effects of radiation based on different energy loss mechanisms from incident protons which induce defects or can promote efficiency recovery. We design a dual dose experiment first exposing devices to low-energy protons efficient in creating atomic displacements. Devices are then irradiated with high-energy protons that interact differently. Correlated with modeling, high-energy protons (with increased ionizing energy loss component) effectively anneal the initial radiation damage, and recover the device efficiency, thus directly detailing the different interactions of irradiation. We relate these differences to the energy loss (ionization or non-ionization) using simulation. Dual dose experiments provide insight into understanding the radiation response of perovskite solar cells and highlight that radiation-matter interactions in soft lattice materials are distinct from conventional semiconductors. These results present electronic ionization as a unique handle to remedying defects and trap states in perovskites.

14 SOLAR ENERGY↗

Reconstructing Hanford worker external doses from photons for epidemiology

The accurate reconstruction of external photon doses is essential for credible radiation epidemiology. This article presents the methodology used to derive dose estimates for 37 012 Hanford Site workers included in the Million Person Study. The approach employs historical dose records from the Hanford Radiation Exposure database and a previous epidemiology study. Bias correction factors specific to dosimeter type and period of use were applied and missing annual doses were estimated using a hierarchical nearby method to estimate deep dose equivalent for each worker. For early years with limited detection sensitivity, missed doses were quantified based on expected time-period-specific, low-dose statistical distributions. The revised dose estimates resulted in lower median and mean career doses than unadjusted data, while increasing the number of person-years with nonzero dose. Sensitivity analyses assessed the influence of bias in dosimetry measurements, missed doses and gap years on dose estimates. Differences in cumulative dose estimates between unadjusted and revised annual estimates are most prominent in the early operational years due to the highest bias during that time period.

dose reconstruction↗