Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFLEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Color film preservation system: Breadboard development

The development of an economically feasible system to prevent and/or substantially reduce the degradation of the color dyes of the retinal reflex images recorded on color slide films is discussed. Three different types of film storage systems were designed, fabricated, and tested. An extruded plastic cylindrical container was pressurized and no observable leakage occurred, indicating that long term storage is possible. An operational breadboard was fabricated. The system offers the capability to determine purging requirements to achieve various levels of oxygen concentration and precise leakage of various container configurations. The system has digitial display of oxygen content of the container, automatic control of the oxygen content as well as of the container to atmosphere pressure differential, and flow rate readout during purging.

Source record↗

Physiological functioning of the ear and masking

The physiological functions of the ear and the role masking plays in speech communication are examined. Topics under investigation include sound analysis of the ear, the aural reflex, and various types of noise masking.

Source record↗

Physical fitness and cardiovascular response to lower body negative pressure

Klein et al. (1977) have questioned the concept of endurance training as an appropriate means of preparing for prolonged space flights. Their opinion was mainly based on reports of endurance athletes who had a decreased tolerance to orthostatic or gravitational stress induced by lower body negative pressure (LBNP), upright tilt, or whole body water immersion. The present investigation had the objective to determine if the hemodynamic response to LBNP is different between a high and average fit group of subjects. In addition, the discrete aspect of cardiovascular function which had been altered by chronic training was to be identified. On the basis of the results of experiments conducted with 14 young male volunteers, it is concluded that the reflex response to central hypovolemia is altered by endurance exercise training.

Raven, P. B.↗

Cardiovascular responses during orthostasis - Effect of an increase in maximal O2 uptake

A study is described which tests the hypothesis that changes in aerobic activity (increases in maximum oxygen uptake) will reduce the effectiveness of cardiovascular reflexes to regulate blood pressure during orthostasis. The hypothesis was tested by measuring heart rate, blood pressure and blood volume responses in eight healthy male subjects before and after an eight-day endurance regimen. The results of the study suggest that the physiologic responses to orthostasis are dependent upon the rate of plasma volume loss and pooling, and are associated with training-induced hypervolemia. It is indicated that endurance type exercise training enhances cardiovascular adjustments during tilt. The implications of these results for the use of exercise training as a countermeasure and/or therapeutic method for the prevention of cardiovascular instability during orthostatic stress are discussed.

Convertino, V. A.↗

Effects of External Loads on Human Head Movement Control Systems

The central and reflexive control strategies underlying movements were elucidated by studying the effects of external loads on human head movement control systems. Some experimental results are presented on dynamic changes weigh the addition of aviation helmet (SPH4) and lead weights (6 kg). Intended time-optimal movements, their dynamics and electromyographic activity of neck muscles in normal movements, and also in movements made with external weights applied to the head were measured. It was observed that, when the external loads were added, the subject went through complex adapting processes and the head movement trajectory and its derivatives reached steady conditions only after transient adapting period. The steady adapted state was reached after 15 to 20 seconds (i.e., 5 to 6 movements).

Nam, M. H.↗

Effects of Weightlessness of Aurelia Ephyra Differentiation and Statolith Synthesis

Aurelia polyps are especially suited for space flight experiments because they are very small (2 to 4 mm), form ephyrae with gravity sensing structures in 6 to 7 days, and can be reared easily and inexpensively in the laboratory. During iodine-induced metamorphosis ephyrae develop in sequential order from the oral to the aboral end of the polyps. Eight sites of gravity receptors (rhopalia) form per ephyra. These structures have sacs of statoliths at their distal end, which are composed of calcium sulfate dihydrate. Only one statolith forms per cell (statocyte) and the cells collect at the distal end of the rhopalia forming statocysts. Rhopalia with statocysts are necessary for the righting reflex of swimming medusae. Using the Aurelia Metamorphosis Test System (Spangenberg, 1984) for the past eight months, the effects of clinostat rotation in the horizontal and verticall planes on the development of ephyrae and the synthesis of their statoliths were investigated.

Dorothy B. Spangenberg↗

Simulation of a G-tolerance curve using the pulsatile cardiovascular model

A computer simulation study, performed to assess the ability of the cardiovascular model to reproduce the G tolerance curve (G level versus tolerance time) is reported. A composite strength duration curve derived from experimental data obtained in human centrifugation studies was used for comparison. The effects of abolishing automomic control and of blood volume loss on G tolerance were also simulated. The results provide additional validation of the model. The need for the presence of autonomic reflexes even at low levels of G is pointed out. The low margin of safety with a loss of blood volume indicated by the simulation results underscores the necessity for protective measures during Shuttle reentry.

Solomon, M.↗

Spacelab 1 and the Life Sciences Flight Experiments Program

The Life Sciences Flight Experiments Program (LSFEP) was established by NASA in 1978 to plan and direct efforts necessary to conduct a continuing program of in-flight life science investigations throughout the Space Shuttle era. The Spacelab 1 (SL-1) mission, conducted from November 28 to December 8, 1983, was to verify Spacelab performance through a variety of scientific experiments including life science. A description is given of the seven NASA life sciences experiments, which consisted of four human experiments, a fungus experiment, a plant experiment, and radiation experiments. Ten life sciences experiments from the European Space Agency were also flown. The experiments include studies of the circadian rhythms in Neurospora crassa, the nutation of Helianthus annus, the vestibular function during weightlessness, the influence of space flight on erythrokinetics in man, and the adaptation of vestibulo-spinal reflex mechanisms during space flight.

Bush, W. H.↗

Improved aqueous scrubber for collection of soluble atmospheric trace gases

A new concentration technique for the extraction and enrichment of water-soluble atmospheric trace gases has been developed. The gas scrubbing technique efficiently extracts soluble gases from a large volume flow rate of air sample into a small volume of refluxed trapping solution. The gas scrubber utilizes a small nebulizing nozzle that mixes the incoming air with an aqueous extracting solution to form an air/droplet mist. The mist provides excellent interfacial surface areas for mass transfer. The resulting mist sprays upward through the reaction chamber until it impinges upon a hydrophobic membrane that virtually blocks the passage of droplets but offers little resistance to the existing gas flow. Droplets containing the scrubbed gases coalesce on the membrane and drip back into the reservoir for further refluxing. After a suitable concentration period, the extracting solution containing the analyte can be withdrawn for analysis. The nebulization-reflex concentration technique is more efficient (maximum flow of gas through the minimum volume of extractant) than conventional bubbler/impinger gas extraction techniques and is offered as an alternative method.

Cofer, W. R., III↗

Canadian medical experiments on Shuttle Flight 41-G

During the 41-G mission, two payload specialist astronauts took part in six Canadian medical experiments designed to measure how the human nervous system adapts to weightlessness, and how this might contribute to space motion sickness. Similar tests conducted pre-flight provided base-line data, and post-flight experiments examined re-adaptation to the ground. No changes were detected in the vestibulo-ocular reflex during this 8-day mission. Pronounced proprioceptive illusions were experienced, especially immediately post-flight. Tactile acuity was normal in the fingers and toes, but the ability to judge limb position was degraded. Estimates of the locations of familiar targets were grossly distorted in the absence of vision. There were no differences in taste thresholds or olfaction. Despite pre-flight tests showing unusual susceptibility to motion sickness, the Canadian payload specialist turned out to be less susceptible than normal on-orbit. Re-adaptation to the normal gravity environment occurred within the first day after landing.

Watt, D. G. D.↗

Spectroscopic planetary detection

The Sun-as-a-star was monitored using the McMath Fourier transform spectometer (FTS) on Kitt Peak in 1983. In 1985 the first measurement was made using the laser heterodyne technique. The FTS measurements now extend for three years, with errors of order 3 meters/sec at a given epoch. Over this 3 year period, a 33 meter/sec change was measured in the apparent velocity of integrated sunlight. The sense of the effect is that a greater blueshift is seen near solar minimum, which is consistent with expectations based on considering the changing morphology of solar granular convection. Presuming this effect is solar-cycle-related, it will mimic the Doppler reflex produced by a planetary companion of approximately two Jupiter masses, with an 11 year orbital period. Thus, Jupiter itself is below the threshold for detection by spectroscopic means, without an additional technique for discrimination. However, for planetary companions in shorter period orbits (P approx. 3 years) the threshold for unambiguous detection is well below one Jupiter mass.

Deming, D.↗

The radial velocity search for extrasolar planets

Stars are observed with a ground-based instrument designed to measure small changes in the line-of-sight velocities. The purpose of the observations is to detect large planets by the oscillatory reflex motion they induce on the stars they are orbiting. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. Changes in the line-of-sight velocities are revealed by changes in the Doppler shift of the absorption-line spectra of stars. The scrambling of incident light by an optical fiber and the stability of wavelength calibration by a tilt-tunable Fabry-Perot etalon provide immunity to systematic errors that historically have effected more conventional radial velocity spectrographs. A cross-dispersed echelle spectrograph spatially separates the orders of constructive interference transmitted through the etalon. Selecting several echelle diffraction orders in the vicinity of 4250 to 4750 A, which are imaged on a CCD, about 350 points on the profile of the stellar spectrum are sampled by successive orders of interferometric transmission through the etalon.

Mcmillen, R. S.↗

Role of orientation reference selection in motion sickness

The objectives of this proposal were developed to further explore and quantify the orientation reference selection abilities of subjects and the relation, if any, between motion sickness and orientation reference selection. The overall objectives of this proposal are to determine (1) if motion sickness susceptibility is related to sensory orientation reference selection abilities of subjects, (2) if abnormal vertical canal-otolith function is the source of these abnormal posture control strategies and if it can be quantified by vestibular and oculomotor reflex measurements, and (3) if quantifiable measures of perception of vestibular and visual motion cues can be related to motion sickness susceptibility and to orientation reference selection ability demonstrated by tests which systematically control the sensory imformation available for orientation.

Peterka, Robert J.↗

Photorefractor ocular screening system

A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.

Richardson, John R.↗

General purpose algorithms for characterization of slow and fast phase nystagmus

In the overall aim for a better understanding of the vestibular and optokinetic systems and their roles in space motion sickness, the eye movement responses to various dynamic stimuli are measured. The vestibulo-ocular reflex (VOR) and the optokinetic response, as the eye movement responses are known, consist of slow phase and fast phase nystagmus. The specific objective is to develop software programs necessary to characterize the vestibulo-ocular and optokinetic responses by distinguishing between the two phases of nystagmus. The overall program is to handle large volumes of highly variable data with minimum operator interaction. The programs include digital filters, differentiation, identification of fast phases, and reconstruction of the slow phase with a least squares fit such that sinusoidal or psuedorandom data may be processed with accurate results. The resultant waveform, slow phase velocity eye movements, serves as input data to the spectral analysis programs previously developed for NASA to analyze nystagmus responses to pseudorandom angular velocity inputs.

Lessard, Charles S.↗

The convective noise floor for the spectroscopic detection of low mass companions to solar type stars

The threshold mass for the unambiguous spectroscopic detection of low mass companions to solar type stars is defined here as the time when the maximum acceleration in the stellar radial velocity due to the Doppler reflex of the companion exceeds the apparent acceleration produced by changes in convection. An apparent acceleration of 11 m/s/yr in integrated sunlight was measured using near infrared Fourier transform spectroscopy. This drift in the apparent solar velocity is attributed to a lessening in the magnetic inhibition of granular convection as solar minimum approaches. The threshold mass for spectroscopic detection of companions to a one solar mass star is estimated at below one Jupiter mass.

Deming, D.↗

Microcirculatory fluid dynamics in weightlessness and simulated weightlessness

The method of Smith et al. (1985), which makes it possible to simultaneously measure the macrocirculation and microcirculation in an unanesthetized rat, was used to study the effect of acute hypokinesia on the rat microvascular system. The measurements yielded values of the length, diameter, and number of arteriolar and venular vessels; vascular patterns; branching ratios; and the amplitude and frequency of vasomotion. Early effects (30-60 min after the start of the head-down tilt) include a 10 percent increase in the diameter of arterioles, a slight increase of heart rate and mean arterial blood pressure, and an increase in the heart rate-pulse pressure product, with most of the changes returning to normal after 2-3 h. The baroreceptor reflex index was reduced by almost 50 percent for the first 2 h, but rebounded to almost 3 times the control value after 3 h. This indicates that, in spite of relatively small changes in gross hemodynamic parameters, the cardiovascular function is altered significantly during the acute phase of hypokinesia.

Hutchins, P. M.↗

Lightweight Video-Camera Head

Compact, lightweight video camera head constructed by remounting lens and charge-coupled-device image detector from small commercial video camera in separate assembly. Useful in robotics, artificial vision, and vision guidance systems. Designed to be mounted on visor of helmet to monitor motions of eyes in experiments on vestibulo-ocular reflexes.

Proctor, David R.↗