Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

444 records · Page 25

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FORTE Measurements of Global Optical Lightning Waveforms and Implications for Optical Lightning Detection

Lightning processes generate a diverse collection of optical pulses from current traversing the lightning channels. These signals are then broadened spatially and temporally via scattering in the clouds. The resulting waveforms measured from space with instruments like the photodiode detector (PDD) on the Fast On-orbit Recording of Transient Events (FORTE) satellite have a variety of shapes. In this study, we use coincident optical and Radio-Frequency measurements to document the properties of optical PDD waveforms associated with different types of lightning, estimate delays from scattering in the clouds, and comment on how pulse shape impacts optical lightning detection. We find that the attributes of optical pulses recorded by the PDD are consistent with prior studies, but vary globally and with event amplitude. The most powerful lightning tends to be single-peaked with faster rise times (median: ~100 µs) and shorter effective widths (median: ~400 µs) than normal lightning. Particularly dim events, meanwhile, include cases of broad optical waveforms with sustained optical emission throughout the PDD record, which the pixelated FORTE Lightning Location System (LLS) instrument has difficulty detecting. We propose that this is due to the optical signal being divided between individual LLS pixels that are each, individually, not bright enough to trigger. We use PDD waveforms and Monte Carlo radiative transfer modeling to demonstrate that increasing the temporal and spatial resolution of a pixelated lightning imager will make it more difficult to detect these broad/dim pulses as their energy becomes divided between additional pixels/integration frames.

54 ENVIRONMENTAL SCIENCES↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded sensors integrated into critical components for in situ health monitoring of steam turbines

Operational flexibility is desired in today’s coal-fired power plants to balance power grids by compensating for the variable electricity supply from renewable energy sources and distributed gensets. This demanding requirement accelerates materials degradation and makes in-situ health monitoring essential. Life monitoring of components and subsystems is thus seen as essential in assessing material and mechanical behavior to estimate system reliability, move to a conditionbased maintenance strategy and determine time to failure of the units in their actual operating conditions. Vibration monitoring can be exploited for blade tip timing to measure blade vibration amplitude and tip clearance to detect any deterioration taking place in the condition of steam turbine blades. A failure of a rotating blade can lead to severe turbine damage followed by extensive repairs and loss of power production. A blade vibration monitoring system can help early detection of abnormal blade vibration behavior. In conjunction with a health monitoring system, the vibration characteristics can be analyzed to support a pro-active maintenance and inspection schedule. While the feasibility of this inspection technique has been amply demonstrated, there is a need to install induction probes to magnetize the blade for signal output. Siemens, in partnership with Raytheon Technologies Research Corporation (RTRC), proposes a holistic approach to develop embedded sensors to utilize radio frequency for not only coupling to sensors, but as the sensing modality. The goal of this project is to “embed” the novel sensing approach by using either additively manufactured or extruded waveguides on rotating blades for recording, evaluation and monitoring of blade vibrations in Low Pressure turbines, with applications extending to aero engines

01 COAL, LIGNITE, AND PEAT↗

Orientation-dependent structural properties during growth and growth mechanism of CoO films

The orientation-dependent local structural properties of CoO films on sapphire substrates during growth were investigated through linearly-polarized extended X-ray absorption fine structure (EXAFS) measurements. Specifically, CoO(1 1 1) and (100) crystals with a rock-salt structure (Fm3m) were epitaxially grown on alpha-Al2O3(0001) and (1012) substrates, respectively, at 700 degrees C using a radio-frequency sputtering system. The local structural properties of CoO films in the in-plane and out-of-plane orientations were quantitatively determined using linearly-polarized EXAFS at the Co K-edge during growth. The EXAFS analysis revealed that during the initial stages of growth, the local structural properties exhibit significant differences compared to thick films, with short atomic distances and large (small) Debye-Waller factors observed in the out-of-plane (in-plane) orientations. The local structural strain mostly diminished when approximately 20 CoO layers accumulated on the substrate. Density functional theory (DFT) calculations further supported these findings by confirming that cobalt atoms initially form stable bonds with the sapphire surface, leading to the simultaneous growth of oxygen and cobalt layers in a coordinated manner through layer-by-layer growth.

36 MATERIALS SCIENCE↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗

Characterization of W production during ICRF operations: experiments and modeling

For successfully heating plasma with waves in the ion cyclotron range of frequencies (ICRFs), mitigating impurity production is just as crucial as maximizing power coupling, especially in high-Z environments. ICRF can effectively deposit energy on ions, modify turbulence-driven transport, and enhance fusion reaction efficiency, but only when its power coupling has minimal impact on impurity production. To do so, one must rely on a toroidal array of at least three active elements excited with appropriate phasing and power ratio to reduce the currents induced on the antenna frame below levels critical for physical sputtering. In contrast to classic two-strap antennas, which are optimized for dipole phasing with equal power on both straps, three-strap antennas in ASDEX Upgrade (AUG)—but also four-strap antennas in JET, Alcator C-Mod, SPARC and ITER—offer the possibility to act also on the power ratio between the central and outer straps. With optimal settings, impurity production can be reduced substantially, making the ICRF compatible with the high-Z wall. This paper explores the characteristics of the AUG three-strap antennas in terms of impurity production, as well as the key role of plasma composition in this process. Numerical simulations were performed using SSWICH and Petra-M (finite element codes) to quantify impurity production and compare with experimental results. Energies of ions falling on antenna limiters (measured with probes) are well predicted by both codes. These tools are then used to further describe the source of the impurity, namely the gross erosion of tungsten from an ICRF antenna, for different plasma mixtures. Results are also compared to spectroscopy data. Ultimately, we show that deleterious effects of the ICRF on plasma surface interactions will be weaker in plasmas containing larger fractions of highly ionized heavier low-Z impurity, which is typically relevant for experiments relying on impurity seeding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MOCVD Growth and Characterization of ZnSnN 2

Since the first few reports of its synthesis in 2011 and 20121-3, interest in ZnSnN 2 for diverse applications, including photovoltaics1,3,4, visible light photocatalysis5, and optoelectronics, has been growing. Novel nitride-based LED device designs promise high gains in efficiency at emission wavelengths into the green, amber and even red.6-8 Their realization requires the precise insertion of an ultrathin layer of ZnGeN 2 or ZnSnN 2 into the active region of an InGaAs-GaAs LED structure. While thin films of ZnSnN 2 have been synthesized by RF sputtering1,9 and by MBE 2,10,11, and thin films of ZnGeN 2 , ZnSiN 2 and their alloys by MOCVD, the synthesis of ZnSnN 2 thin films by MOCVD has not yet been reported. It is a challenging goal, given the narrow temperature window between efficient activation of ammonia and the thermal decomposition of ZnSnN 2 at near-atmospheric pressures. We report here the results of studies of ZnSnN 2 films grown on r- and c-plane sapphire substrates, GaN templates on sapphire, and In 0.15 Ga 0.85 N templates on GaN-on-sapphire, at temperatures from 500 °C to 560 °C, using tetramethyltin (TMSn), diethylzinc (DEZn), germane and ammonia. Chamber pressures were varied between 200 and 500 torr. In addition, the ratios of the cation precursors and the total cation-to-anion precursor ratios were varied. Single crystal growth, as evidenced by 2θ-ω x-ray diffraction scans, was achieved on all of these substrates. Wurtzitic (0002) ZnSnN 2 diffraction were observed at 2θ ~ 32.90 for the samples grown on c-sapphire, GaN (0001) and InGaN (0001) templates, and wurtzitic (11-20) peak at 2θ ~ 54.80 for the films grown on r-sapphire. Higher pressures and higher temperatures promoted better crystallinity and more continuous films, as revealed by scanning electron microscopy (SEM) images and 2θ-ω x-ray diffraction peak widths and intensities. Crystal quality was observed to be highly dependent on growth temperature. For example, in one series a 10 °C change in growth temperature resulting in a factor of 15 increase in diffraction peak intensity. SEM images show that films grown on the GaN templates had better uniformity in nucleation than those grown on sapphire. The presence of satellite peaks around the Bragg peak in the XRD 2θ-ω scan for a film grown on a GaN template, and the absence of satellite peaks for the films grown simultaneously on c- and r-sapphire, also indicate superior quality for the film grown on GaN. HAADF-STEM images of films grown on these templates showed smooth interfaces at the film-substrate boundary and show growth rates as high as 167 nm/h, considerably higher than reported previously for MBE growth.9,10 Electron diffraction patterns show single crystallinity. Rocking curves show FWHM as low as 0.100. RMS surfaces roughnesses, measured by atomic force microscopy, are of the order of 3 nm for 1µm x 1µm areas. Current work is focusing on optimizing growth on InGaN templates. These templates are promising for their relatively lower lattice mismatch with ZnSnN 2 . Their use is a next step toward producing LED device structures.

Jayatunga, Benthara Hewage Dinushi↗

Spin Squeezing with Itinerant Magnetic Dipoles

Entanglement can improve the measurement precision of quantum sensors beyond the shot noise limit. Neutral atoms, the basis of some of the most precise and accurate optical clocks and interferometers, do not naturally exhibit the all-to-all interactions traditionally used to generate such entangled states. On the other hand, these systems exhibit exceedingly high degrees of experimental control over parameters such as temperature, spatial entropy, and itinerancy. In this work, we investigate spin squeezing in a highly coherent itinerant system of neutral atoms with magnetic dipole-dipole interactions. We achieve 7.1 dB of metrologically useful squeezing using finite-range spin-exchange interactions in an erbium quantum gas microscope, and we demonstrate that introducing atomic motion, realizing a dipolar 𝑡−𝐽 model, protects the spin sector coherence at low fillings, significantly improving the achievable spin squeezing in a 2D dipolar system. This work’s protocol can be implemented with most neutral atoms, opening the door to quantum-enhanced metrology in other itinerant dipolar systems, such as molecules or optical lattice clocks, and serves as a novel method for studying itinerant quantum magnetism with long-range interactions.

Atomic, optical & lattice clocks↗

Comparison between Alcator C-Mod ICRF experiments and 3D full wave simulations

Reliable modeling of ion cyclotron range of frequencies (ICRF) antenna performance is essential for interpreting present experiments and guiding the design of future reactors. In this work, a 3D model of the Alcator C-Mod field-aligned antenna is implemented in the Petra-M finite-element framework [S. Shiraiwa et al 2023 Nucl. Fusion 63 026024] and benchmarked against experimental results. Four experimental cases are examined. First, the simulated rectified sheath potentials on the antenna limiters are compared with measurements from a power tapering experiment. Second, proof-of-principle far-field sheath simulations are performed. In scenarios with low single-pass absorption, simulations predict enhanced sheath potentials on a distant poloidal limiter in the far field of the antenna, consistent with experimental observations. Third, the simulated antenna loading during edge localized modes follows experimental trends and appears to be dominated by the density gradient at the pedestal. Finally, Petra-M predicts the unintended excitation of high-$k$ ∥ modes during monopole phasing operation, in agreement with experimental evidence of poor wave coupling and accessibility to the plasma core. Overall, reasonable agreement is found between the simulations and experiments. At the same time, areas of imperfect agreement are identified. These provide important guidance on the limits of the current state-of-the-art modeling, which should be kept in mind when using it as a predictive tool for future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗