Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A modified eco-efficiency framework and methodology for advancing the state of practice of sustainability analysis as applied to green infrastructure: Sustainability Analysis of Rainwater Harvesting

We propose a modified eco-efficiency (EE) framework and novel sustainability analysis methodology for green infrastructure (GI) practices used in water resource management. Green infrastructure practices such as rainwater harvesting (RWH), rain gardens, porous pavements, and green roofs are emerging as viable strategies for climate change adaptation. The modified framework includes 4 economic, 11 environmental, and 3 social indicators. Using 6 indicators from the framework, at least 1 from each dimension of sustainability, we demonstrate the methodology to analyze RWH designs. We use life cycle assessment and life cycle cost assessment to calculate the sustainability indicators of 20 design configurations as Decision Management Objectives (DMOs). Five DMOs emerged as relatively more sustainable along the EE analysis Tradeoff Line, and we used Data Envelopment Analysis (DEA), a widely applied statistical approach, to quantify the modified EE measures as DMO sustainability scores. We also addressed the subjectivity and sensitivity analysis requirements of sustainability analysis, and we evaluated the performance of 10 weighting schemes that included classical DEA, equal weights, National Institute of Standards and Technology’s stakeholder panel, Eco-Indicator 99, Sustainable Society Foundation’s Sustainable Society Index, and 5 derived schemes. We improved upon classical DEA by applying the weighting schemes to identify sustainability scores that ranged from 0.18 to 1.0, avoiding the nonuniqueness problem and revealing the least to most sustainable DMOs. Our methodology provides a more comprehensive view of water resource management and is generally applicable to GI and industrial, environmental, and engineered systems to explore the sustainability space of alternative design configurations.

Sustainability Rainwater harvesting↗

Estimating and parameterizing mismatch power loss in bifacial photovoltaic systems

Nonuniform irradiance on the rear side of bifacial photovoltaic (PV) systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. We evaluated several scenarios including horizontal single-axis tracking (HSAT) over natural ground-cover and rooftop-mounted systems over high albedo reflective roofs. We found mismatch losses of up to 1.5% annual loss for very close-mounted (0.15 m) rooftop systems, but losses for HSAT systems and high-ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically, the mean absolute difference of irradiance) to the resulting mismatch loss factor, with an R 2 better than .99. Furthermore, this approximate relationship was experimentally validated on mismatched PV modules, and it provides a basis for rapidly estimating bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM. Additional parameters investigated include (a) climate dependence and module orientation, which were not found to have a strong impact on bifacial mismatch losses and (b) PV module fill factor and bifaciality ratio, which did have a strong linear impact on mismatch losses.

14 SOLAR ENERGY↗

MgZnO High‐Voltage Transparent Thin‐Film Transistors Built on Glass

Recently, there has been increasing interest in building‐integrated photovoltaic (BIPV), which enables harvesting solar energy effectively. Large‐area glass components such as windows are widely used in modern constructions. In addition to the PV on opaque components such as walls and roofs, the transparent photovoltaic (TPV) directly built on glass is complementary to fully utilize the PV energy in BIPV. A high‐voltage transparent thin‐film transistor (HVTTFT) built on glass is an ideal option for distributed microinverters for TPV modules. A wide‐bandgap oxide‐based HVTTFT on glass for this purpose is reported. The HVTTFT on glass uses ZnO‐based materials with different functions for two roles: a semiconductor Mg 0.01 Zn 0.99 O (MZO) as TFT channel and Al‐doped ZnO (AZO) as transparent conductive oxide (TCO) electrodes. The centrosymmetric circular structure of the MZO HVTTFT with a high‐k‐stacking gate dielectric enables a blocking voltage as high as ≈1 kV and an on/off ratio of 10 6 . The device exhibits an average optical transmittance of 81% over the visible spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial Simulation and Characterization of Three-Dimensional Fractures in Gejiu tin District, Southwest China, Using GEOFRAC

Fracture is an important factor controlling mineralization and ore distribution in metallic deposits. Fracture also affects mechanical stability of drifts. A plausible three-dimensional discrete fracture network (DFN) was constructed using GEOFRAC, a geostatistical method of conditioning directions (strikes and dips) and locations of sample fractures. The northern part of the Gejiu tin district, southwest China, was selected, using 10,212 fractures sampled on drift roofs at five different levels and along a 5463 m length. Key parameters of this DFN are fracture density, direction, and the connective condition of disks that form a fracture plane. The simulated fractures were verified by good correspondence of their directions with those of the sample fractures; furthermore, continuous fractures longer than 1 km matched the faults observed in outcrops. The most notable result was clarification of fracture control by the orebody shape: Simulated gentle fractures (30° dips or less) formed layered orebodies and created boundaries between each layer, while steep fractures (60° dips or more) displaced the layers by acting as faults. Such fault-type fractures and the densely fractured portions require caution with respect to mining safety. It was concluded that GEOFRAC is useful for three-dimensional DFN modeling in underground mines.

58 GEOSCIENCES↗

Wetting and Interfacial Reactivity of Zn-Coated Steel Products with Cu-Si, Cu-Sn and Al-Si Filler Metals for Laser Brazing Application

The laser brazing process is successfully applied in automotive industry for joining of roofs and hatchbacks of vehicles. The bad wetting of the brazing alloy during the process can lead to the formation of random external porosities which are not allowed on visible parts. This paper describes the wettability and reactivity mechanisms at short contact time of Cu and Al matrix brazing alloys with different reactive elements (Si, Sn) on different steel products such as hot-dip galvanized steels, galvannealed steel and bare steel. Wetting experiments were carried out by the dispensed drop technique. The effects of alloying elements and brazing alloy matrix on interfacial reactivity are discussed. It was found that Cu matrix containing 3 wt.% Si is the most favorable for short time liquid/solid adhesion relatively to the other studied brazing alloy compositions. The brazing ability of different steel products is well correlated with the wettability and interfacial reactivity results.

36 MATERIALS SCIENCE↗

Effectiveness of nature-based solutions to reduce flooding in Quad Cities Metro Area (QCMA) using SWMM-HEC based flood model

Nature-based solutions (NbS) have gained significant attention as strategies for addressing urban environmental challenges, particularly since the establishment of the UN Sustainable Development Goals (SDGs) for 2030. However, the current research on NbS for urban flood management lacks comprehensive methodological approaches for identifying suitable areas and evaluating their effectiveness across different urban settings. Here, this study attempts to fill this gap by proposing a methodological framework integrating multi-criteria analysis with a SWMM-HEC-based hydrologic and hydraulic (HH) model to assess the suitability of NbS for the Quad Cities Metro Area (QCMA), consisting of Davenport, Bettendorf, Moline, and Rock Island. Eight NbS options-green roofs, rain gardens, infiltration trenches, permeable pavements, vegetative swales, dry detention basins, retention ponds, and rain barrels/cisterns - were considered based on volumetric efficiency and runoff reduction efficiency. The study reveals that implementing the proposed NbS could have substantially reduced flood depths in key historical flood events by 21% in 1993, 15% in 2008, 16% in 2011, 23% in 2014, 40% in 2019, and 10% in 2023. The findings highlight a critical trade-off between peak runoff and NbS implementation: while NbS effectively reduce flood impacts, they also enhance volumetric efficiency by approximately 43%. In high-density areas of the QCMA, flood depth reductions of around 20% suggest that NbS are a viable solution for dense urban environments with limited space. This shows the potential for integrating NbS into existing infrastructure, offering a promising approach for cities facing increasing flooding risks. The proposed methodology provides a practical framework for incorporating NbS into urban stormwater management, addressing gaps in optimizing NbS performance, and offering a pathway to scale their application in other urban areas with various environmental and social contexts.

CMIP6↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Permeability variations within mining-induced fractured rock mass and its influence on groundwater inrush

This paper is concerned with the evaluation of permeability of fractured rock mass due to the cover stress re-establishment, which is a major factor in controlling water and gas flow rate induced by mining operations in fractured rock. The case study considered in this paper is based on the results of observations of groundwater inrush and a decrease in water inflow from the fractured roof strata due to mining advancing in the Taiping Coalmine, Shandong Province, China. A conceptual model of an effective porous media was used to assess the permeability distribution in the fractured zone induced by coal mining. The cover stress re-establishment in gob fractured rock mass was evaluated using an empirical formula based on the surface subsidence. A simplified conceptual model of the fractured zone was used to evaluate the deformation of fractured zone along with the evaluation of changes in the rock permeability above the gob due to the cover stress re-establishment. These data were then used to calculate the water inflow rate into the panel. Predicted water inflow rates have been found to be in good agreement with those from monitoring data. This study improved the understanding of the mechanisms of the post-mining cover stress re-establishment on permeability change of the overburden fracture rock strata. These results can then be applied for numerical simulations of the process of overburden failure and consequent groundwater inrush due to coal mining.

54 ENVIRONMENTAL SCIENCES↗

Self-cleaning and de-pollution efficacies of photocatalytic architectural membranes

Photocatalytic self-cleaning “cool” roofs and walls can maintain high albedos, saving building cooling energy, reducing peak power demand, and mitigating the urban heat island effect. Other environmental benefits result from their de-polluting properties. Specimens from two different photocatalytic architectural membranes and a non-photocatalytic control were exposed alongside vertically, facing west, for two years at three California sites, and retrieved quarterly for testing. Photocatalytic materials showed excellent self-cleaning performance, retaining albedos of 0.74 – 0.75. By contrast, the control material exhibited an albedo loss of up to 0.10, with appreciable soiling observed by scanning electron microscopy. De-pollution capacity was assessed by quantifying NO removal and NOx deposition rates at 60 °C. Furthermore, efficacy varied with exposure location, weather conditions, and the nature of the photocatalytic material. Seasonal effects were observed, with partial inhibition during the dry season and reactivation during the rainy season.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelling cycle to cycle variations in an SI engine with detailed chemical kinetics

This paper presents experimental results and a new computational model that investigate cycle to cycle variations (CCV) in a spark ignition (SI) engine. An established stochastic reactor model (SRM) previously used to examine homogeneous charge compression ignition (HCCI) combustion has been extended by spark initiation, flame propagation and flame termination sub-models in order to simulate combustion in SI engines. The model contains a detailed chemical mechanism but relatively short computation times are achieved. The flame front is assumed to be spherical and centred at the spark location, and a pent roof and piston bowl geometry are accounted for. The model is validated by simulating the pressure profile and emissions from an iso-octane fuelled single cylinder research engine that showed low CCV. The effects of key parameters are investigated. Experimental results that show cycle to cycle fluctuations in a four-cylinder naturally aspirated gasoline fuelled SI engine are presented. The model is then coupled with GT-Power, a one-dimensional engine simulation tool, which is used to simulate the breathing events during a multi-cycle simulation. This allows an investigation of the cyclic fluctuations in peak pressure. The source and magnitude of nitric oxide (NO) emissions produced by different cycles are then investigated. It was found that faster burning cycles result in increased NO emissions compared with cycles that have a slower rate of combustion and that more is produced in the early stages of combustion compared with later in the cycle. The majority of NO was produced via the thermal mechanism just after combustion begins. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Photovoltaic device innovation for a solar future

Photovoltaics (PV), also known as solar cells, are now found everywhere - in utility plants; on roofs of homes and commercial buildings; on platforms at sea; in agricultural fields; on vehicles, buildings, drones, and backpacks; and, in their longest running application, providing power in space. Continuous device innovation has led to increased efficiency and improved reliability for multiple PV technologies. Confronted with an urgent need to deploy PV at multiterawatt (TW) scale over the next two decades to mitigate greenhouse gas emissions, PV device innovation takes on new urgency and impact. This perspective reviews recent progress in device design and performance for PV technologies that are currently in commercial production at greater than 1 GW/year or enabling significant space-based power generation - Si, CdTe, CIGS, and multijunction III-V - and looks ahead to the next 5 years. In conclusion, we also identify device-related topics requiring cross-cutting research and innovation.

14 SOLAR ENERGY↗

Numerical simulation of buoyancy-driven turbulent ventilation in attic space under winter conditions

Attic design and construction have significant impacts on residential buildings’ energy performance. In order to understand how passive ventilation rates affect ridge-vent attic's performance, a two-dimensional steady-state finite volume model is employed to simulate the buoyancy-driven turbulent ventilation and heat transfer in a triangular attic space of a gable-roof residential building under winter conditions. The modeled attic has a pitch of 5/12 and a passive ventilation system, consisting of continuous ridge and soffit vents. The v2f model is used to analyze the turbulent air flow and natural convection heat transfer inside the attic. The effects of ambient air temperature, vent size, and ceiling insulation on heating load and ice dam formation are investigated. The thermal performance of the vented attic is compared with a sealed attic as well. Here, the simulation results reveal that symmetrical air flow patterns exist in a vented attic, in contrast to the asymmetrical air flow patterns found in a sealed attic. In addition, it is suggested that increasing vent size results in higher ventilation air flow rate but barely affects the attic heating load, and that both sufficient ventilation and insulation are needed to ensure the proper functions of the attic and its energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and environmental consequences of a cool pavement campaign

Raising the albedo (solar reflectance) of streets can lower outside air temperature, reduce building energy use, and improve air quality in cities. However, the production and installation of pavement maintenance and rehabilitation treatments with enhanced albedo (“cool” pavements) may entail more or less energy consumption and carbon emission than that of less-reflective treatments. We developed several case studies in which a cool surface treatment is substituted for a more typical treatment (that is, a cool technology is selected instead of a more typical technology). We then assessed over a 50-year analysis period the changes in primary energy demand (PED, excluding feedstock energy) and global warming potential (GWP, meaning carbon dioxide equivalent) in Los Angeles and Fresno, California. The analysis considers two stages of the pavement life cycle: materials and construction (MAC), comprising material production, transport, and construction; and use, scoped as the influence of pavement albedo on cooling, heating, and lighting energy consumption in buildings. In Los Angeles, substituting a styrene acrylate reflective coating or a chip seal for a slurry seal in routine maintenance, or a bonded concrete overlay on asphalt (BCOA) without supplementary cementitious materials (SCM) for mill-and-fill asphalt concrete in conventional or long-life rehabilitation, induced MAC-stage PED and GWP penalties that substantially exceeded use-stage savings, primarily due to material production. Modified rehabilitation cases in which SCM comprised 21% to 50% of the BCOA's total cementitious content by mass (portland cement + SCM) yielded smaller total (MAC + use) PED and GWP penalties, or even total PED and GWP savings. Trends in Fresno were similar, with some differences in GWP outcomes that result from Fresno's longer heating season. The modified rehabilitation cases using BCOA with high SCM content yielded total GWP savings in each city; all other cases yielded total GWP penalties. Here, the magnitude of the one-time GWP offset offered by global cooling from the increased albedo itself always, and sometimes greatly, exceeded the 50-year total GWP penalty or savings. In Los Angeles, the annual building conditioning (cooling + heating) PED and energy cost savings intensities yielded by cool pavements were each about an order of magnitude smaller than the corresponding savings from cool roofs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting the performance of radiant technologies in attics: Reducing the discrepancies between attic specific and whole-building energy models

The use of radiant technology in attics aims to reduce the radiation component of heat transfer between the attic floor and roof decks, gables, and eaves. Recently, it has been shown that EnergyPlus underestimates the savings using radiant technologies in attic spaces. The aim of this study is to understand why EnergyPlus underestimates the performance of radiant technologies and provide a solution strategy that works within the current capabilities of EnergyPlus. The analysis uses three attic energy models as a baseline for comparison for EnergyPlus. Potential reasons for the discrepancies between the attic specific energy models and EnergyPlus are isolated and individually tested. A solution strategy is proposed using the Energy Management System (EMS) capabilities within EnergyPlus. This solution strategy produces similar results to the other attic specific energy models. This paper shows that the current capabilities of EnergyPlus are sufficient to simulate radiant technologies in attics. The methodology showcased in this paper serves as a guide for engineers and researchers who would like to predict the performance radiant technology in attics using the whole building energy software, EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗