Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Silver nanowire based flexible electrodes with improved properties: High conductivity, transparency, adhesion and low haze

Graphical abstract: This graphical abstract illustrates the schematic representation of the main drawbacks and rectifications for AgNWs based transparent electrodes. - Highlights: • Films exhibited low sheet resistance and optical properties with R{sub s} ≤ 30 Ω/□ and T ≥ 90%. • We decreased haze to 2% by controlling AgNWs length, diameter, and concentration. • We achieved good adhesion for AgNWs on PET film. • There is no significant change in resistance in the bending angle from 0° to 180°, and on twisting. - Abstract: Recent work has been focusing on solution processable transparent electrodes for various applications including solar cells and displays. As well as, the research aims majorly at silver nanowires (AgNWs) to replace ITO. We enhance the transparent electrode performance as a function of optical and mechanical properties with low sheet resistance, by controlling the AgNWs accept ratios, ink composition, and processing conditions. The nanowire network of transparent films agrees with the 2D percolation law. The film transmittance values at 550 nm are coping with a reference ITO film. Sheet resistance and haze values are suitable for flexible electronic applications. We fabricate transparent flexible film using a low-cost processing technique.

36 MATERIALS SCIENCE↗

Roles of reaction kinetics of CO 2 on a PrBaCo 2 O 5.5+δ surfaces

A symmetric PBCO/YSZ/PBCO cell (where PBCO refers to PrBaCo 2 O 5.5+δ , and YSZ to yttria stabilized zirconia) was designed and fabricated for the investigation of the catalytic nature and reaction kinetics of CO 2 on PBCO surfaces. The electrochemical impedance spectroscopy was employed to probe the CO 2 reaction behavior on the PBCO electrode. The symmetric equivalent circuit cell characterization reveals that the surface resistance of CO 2 on PBCO is only 30.2 Ω cm 2 and the maximum surface exchange coefficient k chem is 2.0 × 10 -4 cm s -1 at 1147 K, suggesting that PBCO can be an excellent candidate for CO 2 reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact electrochemical bifunctional NOx/O2 sensors with internal reference for high temperature applications

A bifunctional total NOx and O2 sensor assembly with an internal reference for high temperature sensing. Two electrochemical total NOx(NO+NO2) measuring systems and method were coupled with a metal/metal oxide internal oxygen reference to detect O2 and NOx simultaneously in a combustion environment using a single sensor. A Pd/PdO-containing reference chamber was sealed within a stabilized zirconia superstructure by a high pressure/temperature bonding method. An amperometric and potentiometric NOx sensor assembly was built on the outside of the Pd/PdO chamber. Pt-loaded zeolite Y was used to obtain total NOx capacity and also to cover the Pt electrodes for detecting oxygen in the presence of NOx.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineered MXene quantum dots for micro-supercapacitors with excellent capacitive behaviors

Micro-supercapacitors (MSCs) have drawn tremendous attention as promising candidates to power miniaturized portable/wearable electronics, but they still suffer from unsatisfactory electrochemical performance (e.g., insufficient energy density, mediocre rate capability), thus impeding their widespread applications. Here, a synergistic surface and structure engineering strategy achieved by downsizing to quantum dot scale, doping of heteroatoms, and introducing defects and functional groups is proposed to regulate the physicochemical properties of Ti 3 C 2 T x MXene. Encouragingly, the resulting MSCs based on defect-rich nitrogen-doped Ti 3 C 2 T x quantum dots (QDs) possess excellent electrochemical performance as demonstrated by large operating voltage (3.0 V in ionic liquid and 1.0 V in aqueous electrolyte), perfect rectangular CV shape even at 1000 V·s -1 , high volumetric capacitance of 33.1 F·cm -3 , and superior cycling stability after 10000 cycles. By employing experimental characterizations and density functional theory calculations, the remarkable performance of the MSCs is mainly due to the special chemical states as well as the unique surface and structural features of Ti 3 C 2 T x QDs, which offer abundant active sites, shorten ion diffusion pathways, promote ion/electron transports, and provide enhanced capacitance. Finally, this work provides a new strategy for the design of high-performance MSCs and a reference for the applications of MXene QDs in other energy-related fields.

42 ENGINEERING↗

The Transference Number

The performance of rechargeable batteries and other electrochemical systems depends on the rate at which the working ion (often a cation) is transported from one electrode to the other. The cation transference number is an important transport parameter that affects this rate. The purpose of this perspective is to distinguish between approximate and rigorous methods used in the literature to measure the transference number. We emphasize the fact that this parameter is dependent on the reference frame used in the analysis; care must be taken when comparing values obtained from different sources to account for differences in reference frames. We present data obtained from a well‐characterized electrolyte. We compare rigorously determined transference numbers in two reference frames with values obtained by an approximate method. We conclude with a qualitative discussion of the relationship between the transference number and salt concentration gradients that are obtained when current is drawn through a battery.

Gao, Kevin W.↗

An investigation for the development of an integrated optical data preprocessor

A laboratory model of a 16 channel integrated optical data preprocessor was fabricated and tested in response to a need for a device to evaluate the outputs of a set of remote sensors. It does this by accepting the outputs of these sensors, in parallel, as the components of a multidimensional vector descriptive of the data and comparing this vector to one or more reference vectors which are used to classify the data set. The comparison is performed by taking the difference between the signal and reference vectors. The preprocessor is wholly integrated upon the surface of a LiNbO3 single crystal with the exceptions of the source and the detector. He-Ne laser light is coupled in and out of the waveguide by prism couplers. The integrated optical circuit consists of a titanium infused waveguide pattern, electrode structures and grating beam splitters. The waveguide and electrode patterns, by virtue of their complexity, make the vector subtraction device the most complex integrated optical structure fabricated to date.

Verber, C. M.↗

The Dopamine Assisted Synthesis of MoO3/Carbon Electrodes With Enhanced Capacitance in Aqueous Electrolyte

A capacitance increase phenomenon is observed for MoO 3 electrodes synthesized via a sol-gel process in the presence of dopamine hydrochloride (Dopa HCl) as compared to α-MoO 3 electrodes in 5M ZnCl 2 aqueous electrolyte. The synthesis approach is based on a hydrogen peroxide-initiated sol-gel reaction to which the Dopa HCl is added. The powder precursor (Dopa) x MoO y , is isolated from the metastable gel using freeze-drying. Hydrothermal treatment (HT) of the precursor results in the formation of MoO 3 accompanied by carbonization of the organic molecules; designated as HT-MoO 3 /C. HT of the precipitate formed in the absence of dopamine in the reaction produced α-MoO 3 , which was used as a reference material in this study (α-MoO 3 -ref). Scanning electron microscopy (SEM) images show a nanobelt morphology for both HT-MoO 3 /C and α-MoO 3 -ref powders, but with distinct differences in the shape of the nanobelts. The presence of carbonaceous content in the structure of HT-MoO 3 /C is confirmed by FTIR and Raman spectroscopy measurements. X-ray diffraction (XRD) and Rietveld refinement analysis demonstrate the presence of α-MoO 3 and h-MoO 3 phases in the structure of HT-MoO 3 /C. The increased specific capacitance delivered by the HT-MoO 3 /C electrode as compared to the α-MoO 3 -ref electrode in 5M ZnCl 2 electrolyte in a −0.25–0.70 V vs. Ag/AgCl potential window triggered a more detailed study in an expanded potential window. In the 5M ZnCl 2 electrolyte at a scan rate of 2 mV s −1 , the HT-MoO 3 /C electrode shows a second cycle capacitance of 347.6 F g −1 . The higher electrochemical performance of the HT-MoO 3 /C electrode can be attributed to the presence of carbon in its structure, which can facilitate electron transport. Our study provides a new route for further development of metal oxides for energy storage applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures

Taking advantages of exceptional attributes, such as easy-to-operate, economical, sensitive, portable, and simple-to- construct, considerable attention has been devoted to the integration of recognition elements with electronic elements to develop electrochemical sensors and biosensors. Recent decades tremendous amounts of attention have been witnessed in this active area. Various electrochemical devices such as amperometric sensors, electrochemical impedance sensors, electrochemical luminescence sensors as well as photoelectrochemical sensors, provide wide applications of detecting chemical and biological targets in terms of electrochemical change of electrode interfaces. With remarkable achievements in nanotechnology and nanoscience, nanomaterial-based electrochemical signal amplifications have great potential of improving both in sensitivity and selectivity for electrochemical sensors and biosensors. First of all, it is well known that the electrode materials play a critical role in the construction of high-performance electrochemical sensing platforms for detecting target molecules through various analytical principles. Furthermore, in addition to electrode materials, functional nanomaterials can not only produce a synergic effect among catalytic activity, conductivity and biocompatibility to accelerate the signal transduction, but also amplify biorecognition events by specifically designed signal tags, leading to highly sensitive biosensing. Sig-nificantly, extensive research on construction of functional electrode materials, coupled with numerous electrochemical methods, is advancing wide applications of electrochemical devices. For example, Walcarius et al. highlighted the recent advances of nano-objects, nano-engineered and/or nanostructured materials for the rational design of bio-functionalized electrodes and related (bio)sensing systems.1 The attractiveness of such nanomaterials relies on their ability to act as effective immobilization matrices, and their intrinsic and unique features as described above. These features combined with the functioning of biomolecules contribute to the improvement of bioelectrode performance in terms of sensitivity and specificity. Our group recently presented a general overview of nanomaterial-enhanced paper-based biosensors including lateral-flow test-strip, and paper microfluidic devices.2With different kinds of nanoparticles (NPs), paper-based biosensor devices have shown great potential in the enhancement of sensitivity and specificity of disease diagnosis in developing countries. This review focuses on recent advances in electrochemical sensors and biosensors based on nanomaterials and nanostructures during 2013 to 2014. The aim of this effort is to provide the reader with a clear and concise view of new advances in areas ranging from electrode engineering, strategies for electrochemical signal amplification, and novel electroanalytical techniques used to the miniaturization and integration of the sensors. Moreover, the authors have attempted to highlight areas of latest and significant development of enhanced elec-trochemical nanosensors and nanobiosensors that inspire broader interests across various disciplines. Electrochemical sensors for small molecules, enzyme-based biosensors, genosensors, immunosensors and cytosensors are reviewed herein (Figure 1). Such novel advances are important for the development of electrochemical sensors as that open up new avenues and methods for future research. Readers interested in the general principles of electrochemical sensors and electrochemical methods are recommended to refer to other excellent literature for a broad scope on this area.3-4 However, due to the explosion of publications in this active field, we do not claim that this review includes all of the published works in the past two years. Due to the large activity in this field we apologize to the authors of excellent work, which is unintentionally left out.

Zhu, Chengzhou↗

High Density Nano-Electrode Array for Radiation Detection

Bulk single crystals of Cd1-xZnxTe (x=0.04 to x=0.2) compound semiconductor is used for room temperature radiation detection. The production of large volume of Cd1-xZnxTe with low defect density is expensive. As a result there is a growing research interest in the production of nanostructured compound semiconductors such as Cd1-xZnxTe in an electrochemical route. In this investigation, Cd1-xZnxTe ternary compound semiconductor, referred as CZT, was electrodeposited in the form of nanowires onto a TiO2 nanotubular template from propylene carbonate as the non-aqueous electrolyte, using a pulse-reverse electrodeposition process at 130 ºC. The template acted as a support in growing ordered nanowire of CZT which acts as a one dimensional conductor. Cyclic Voltammogram (CV) studies were conducted in determining the potentials for the growth of nanowires of uniform stoichiometry. The morphologies and composition of CZT were characterized by using SEM, TEM and XRD. The STEM mapping carried out on the nanowires showed the uniform distribution of Cd, Zn and Te elements. TEM image showed that the nanowires were polycrystalline in nature. The Mott-Schottky analysis carried on the nanowires showed that the nanowires were a p-type semiconductor. The carrier density, band gap and resistivity of the Cd0.9Zn0.1Te nanowires were 4.29x1013 cm-3, 1.56 eV and 2.76x1011Ω-cm respectively. The high resistivity was attributed to the presence of deep defect states such as cadmium vacancies or Te antisites which were created by the anodic cycle of the pulse-reverse electrodeposition process. Stacks of series connected CZT nanowire arrays were tested with different bias potentials. The background current was in the order of tens of picoamperes. When exposed to radiation source Amerecium-241 (60 KeV, 4 μCi), the stacked CZT nanowires arrays showed sensing behavior. The sensitivity of the nanowire arrays increased as the number of stacks increased. The preliminary results indicate that the CZT nanowire arrays can be used as a potential X-ray and low energy gamma ray detector material at room temperature with a much low bias potential (0.7 – 4V) as against 300 – 500 V applied in the commercial bulk detector materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of emittance growth and halo particle production in intense charged particle beams using the Paul Trap Simulator Experiment

The Paul Trap Simulator Experiment (PTSX) is a compact laboratory experiment that places the physicist in the frame-of-reference of a long, charged-particle bunch coasting through a kilometers-long magnetic alternating-gradient (AG) transport system. The transverse dynamics of particles in both systems are described by the same set of equations, including nonlinear space-charge effects. The time-dependent voltages applied to the PTSX quadrupole electrodes in the laboratory frame are equivalent to the spatially periodic magnetic fields applied in the AG system. The transverse emittance of the charge bunch, which is a measure of the area in the transverse phase space that the beam distribution occupies, is an important metric of beam quality. Maintaining low emittance is an important goal when defining AG system tolerances and when designing AG systems to perform beam manipulations such as transverse beam compression. Results are reviewed from experiments in which white noise and colored noise of various amplitudes and durations have been applied to the PTSX electrodes. This noise is observed to drive continuous emittance growth and increase in root-mean-square beam radius over hundreds of lattice periods. Additional results are reviewed from experiments that determine the conditions necessary to adiabatically reduce the charge bunch's transverse size and simultaneously maintain high beam quality. During adiabatic transitions, there is no change in the transverse emittance. The transverse compression can be achieved either by a gradual change in the PTSX voltage waveform amplitude or frequency. Results are presented from experiments in which low emittance is achieved by using focusing-off-defocusing-off waveforms.

43 PARTICLE ACCELERATORS↗

BiasMDP: Carrier lifetime characterization technique with applied bias voltage

A characterization method is presented, which determines fixed charge and interface defect densities in passivation layers. This method bases on a bias voltage applied to an electrode on top of the passivation layer. During a voltage sweep, the effective carrier lifetime is measured by means of microwave detected photoconductivity. When the external voltage compensates the electric field of the fixed charges, the lifetime drops to a minimum value. This minimum value correlates to the flat band voltage determined in reference impedance measurements. This correlation is measured on p-type silicon passivated by Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}/HfO{sub 2} stacks with different fixed charge densities and layer thicknesses. Negative fixed charges with densities of 3.8 × 10{sup 12 }cm{sup −2} and 0.7 × 10{sup 12 }cm{sup −2} are determined for Al{sub 2}O{sub 3} layers without and with an ultra-thin HfO{sub 2} interface, respectively. The voltage and illumination dependencies of the effective carrier lifetime are simulated with Shockley Read Hall surface recombination at continuous defects with parabolic capture cross section distributions for electrons and holes. The best match with the measured data is achieved with a very low interface defect density of 1 × 10{sup 10 }eV{sup −1} cm{sup −2} for the Al{sub 2}O{sub 3} sample with HfO{sub 2} interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Treatment of Small Hepatocellular Carcinoma (≤2 cm) in the Caudate Lobe with Sequential Transcatheter Arterial Chemoembolization and Radiofrequency Ablation

PurposeTo evaluate technical feasibility and treatment results of sequential transcatheter arterial chemoembolization (TACE) and cone-beam computed tomography-guided percutaneous radiofrequency ablation (CBCT-RFA) for small hepatocellular carcinoma (HCC) in the caudate lobe.Materials and MethodsInstitutional review board approved this retrospective study. Radiologic database was searched for the patients referred to perform TACE and CBCT-RFA for small caudate HCCs (≤2 cm) between February 2009 and February 2014. A total of 14 patients (12 men and 2 women, mean age; 61.3 years) were included. Percutaneous ultrasonography-guided RFA (pUS-RFA) and surgery were infeasible due to poor conspicuity, inconspicuity or no safe electrode pathway, and poor hepatic reserve. Procedural success (completion of both TACE and CBCT-RFA), technique efficacy (absence of tumor enhancement at 1 month after treatment), and complication were evaluated. Treatment results including local tumor progression (LTP), intrahepatic distant recurrence (IDR), overall survival (OS), and progression-free survival (PFS) were analyzed.ResultsProcedural success and technique efficacy rates were 78.6 % (11/14) and 90.9 % (10/11), respectively. Average follow-up period was 45.3 months (range, 13.4–64.6 months). The 1-, 3-, and 5-year LTP probabilities were 0, 12.5, and 12.5 %, respectively. IDR occurred in seven patients (63.6 %, 7/11). The 1-, 3-, and 5-year PFS probabilities were 81.8, 51.9, and 26 %, respectively. The 1-, 3-, and 5-year OS probabilities were 100, 80.8, and 80.8 %, respectively.ConclusionCombination of TACE and CBCT-RFA seems feasible for small HCC in the caudate lobe not amenable to pUS-RFA and effective in local tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Special tests and destructive physical analyses as used by the Aerospace Corporation with nickel-hydrogen cells

The destructive physical analysis (DPA) of electrochemical devices is an important part of the overall test. Specific tests were developed to investigate the degradation mode or the failure mechanism that surfaces during the course of a cell being assembled, acceptance tested, and life-cycle tested. The tests that have been developed are peculiar to the cell chemistry under investigation. Tests are often developed by an individual or group of researchers as a result of their particular interest in an unresolved failure mechanism or degradation mode. A series of production, operational, and storage issues that were addressed by the Electrochemistry Group at The Aerospace Corporation are addressed. As a result of these investigations, as well as associated research studies carried out to develop a clearer understanding of the nickel oxyhydroxide electrode, a series of unique and useful specialized tests were developed. Some of these special tests were assembled to describe the methods that were found to be particularly useful in resolving a wide spectrum of manufacturing, operational, and storage issues related to nickel-hydrogen cells. The general methodology of these tests is given here with references listed to provide the reader with a more detailed understanding of the tests. The tests are classified according to the sequencing, starting with the impregnation of the nickel plaque material and culminating with the storage of completed cells. The details of the wet chemical procedures that were found to be useful because of their accuracy and reproducibility are given. The equations used to make the appropriate calculations are listed.

Zimmerman, A. H.↗

TU-F-BRE-09: Towards the Establishment of Dosimetric References in Small Fields Using the New Concept of Dose-Area Product

Purpose: To establish dosimetric references of absorbed dose in water in radiation fields smaller than 2 cm used in radiotherapy thanks to a new methodology based on the use of dosimeters larger than the field size. Methods: A new graphite calorimeter was constructed with a large sensitive volume (diameter of the core: 30 mm). This primary dosimeter was fully characterized and compared to previous LNE-LNHB graphite calorimeters in a 60Co large field. A specially designed graphite parallel-plate ionization chamber with a 30 mm collecting electrode was also assembled and tested. Measurements were then conducted in two 6 MV small circular fields of 2 cm and 1 cm diameter respectively, using the new concept of dose-area product instead of punctual dose commonly used in radiotherapy. Results: The dose rate established in a large 60Co field with the new calorimeter is in agreement within 0.4% with previous calorimeters. The ionization chamber shows good characteristics except for a 0.06% drift per hour in water. The ratio of calorimetric against ionometric measurements in the 2 cm diameter field is 1.1% higher than the one in the 1 cm diameter field (with respectively 0.30% and 1.03% type A uncertainty for each field). Conclusion: Results presented here highlight the possibility of measuring dose-area products in small fields with a graphite calorimeter and a parallel-plate ionization chamber. Measurements in a 0.75 cm diameter field are already underway to confirm the trend observed in the 2 cm and 1 cm diameter fields. The last step to establish precise dosimetric references in small fields is to calculate correction factors thanks to Monte Carlo simulations.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

Stress measurements of planar dielectric elastomer actuators

Dielectric elastomer actuator (DEA) micro- and nano-structures are referred to artificial muscles because of their specific continuous power and adequate time response. The bending measurement of an asymmetric, planar DEA is described. The asymmetric cantilevers consist of 1 or 5 μm-thin DEAs deposited on polyethylene naphthalate (PEN) substrates 16, 25, 38, or 50 μm thick. The application of a voltage to the DEA electrodes generates an electrostatic pressure in the sandwiched silicone elastomer layer, which causes the underlying PEN substrate to bend. Optical beam deflection enables the detection of the bending angle vs. applied voltage. Bending radii as large as 850 m were reproducibly detected. DEA tests with electric fields of up to 80 V/μm showed limitations in electrode’s conductivity and structure failures. The actuation measurement is essential for the quantitative characterization of nanometer-thin, low-voltage, single- and multi-layer DEAs, as foreseen for artificial sphincters to efficiently treat severe urinary and fecal incontinence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to {sup 60}Co

Purpose: To investigate the applicability of a wide range of microionization chambers for reference dosimetry measurements in low- and medium-energy x-ray beams. Methods: Measurements were performed with six cylindrical microchamber models, as well as one scanning chamber and two Farmer-type chambers for comparison purposes. Air-kerma calibration coefficients were determined at the University of Wisconsin Accredited Dosimetry Calibration Laboratory for each chamber for a range of low- and medium-energy x-ray beams (20-250 kVp), with effective energies ranging from 11.5 keV to 145 keV, and a {sup 60}Co beam. A low-Z proof-of-concept microchamber was developed and calibrated with and without a high-Z silver epoxy on the collecting electrode. Results: All chambers composed of low-Z materials (Z{<=} 13), including the Farmer-type chambers, the scanning chamber, and the PTW TN31014 and the proof-of-concept microchambers, exhibited air-kerma calibration coefficients with little dependence on the quality of the beam. These chambers typically exhibited variations in calibration coefficients of less than 3% with the beam quality, for medium energy beams. However, variations in air-kerma calibration coefficients of greater than 50% were measured over the range of medium-energy x-ray beams for each of the microchambers containing high-Z collecting electrodes (Z > 13). For these high-Z chambers, which include the Exradin A14SL and A16 chambers, the PTW TN31006 chamber, the IBA CC01 chamber, and the proof-of-concept chamber containing silver, the average variation in air-kerma calibration coefficients between any two calibration beams was nearly 25% over the entire range of beam qualities investigated. Conclusions: Due to the strong energy dependence observed with microchambers containing high-Z components, these chambers may not be suitable dosimeters for kilovoltage x-ray applications, as they do not meet the TG-61 requirements. It is recommended that only microchambers containing low-Z materials (Z{<=} 13) be considered for air-kerma calibrations for reference dosimetry in low- and medium-energy x-ray beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗