Search NASA⌕ Search

SEARCH · Search NASA

Results for “Robotics.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-E-J-46: Evaluation of the Accuracy of a Six Degree of Freedom Robotic Couch Using ConeBeam CT Images of the Isocal Phantom

Purpose The accuracy of Varian PerfectPitch six degree of freedom (DOF) robotic couch was examined using Varian Isocal phantom and cone-beam CT (CBCT) system. Methods CBCT images of the Isocal phantom were taken at different pitch and roll angles. The pitch and roll angles were varied from 357 to 3 degrees in one degree increments by input from service console, generating a total of 49 combinations with couch angle (yaw) zero. The center positions of the 16 tungsten carbide BBs contained in the Isocal were determined with in-house image processing software. Expected BBs positions at different rotation angles were determined mathematically by applying a combined translation/rotation operator to BB positions at zero pitch and roll values. A least square method was used to minimize the difference between the expected BB positions and their measured positions. In this way rotation angles were obtained and compared with input values from the console. Results A total of 49 CBCT images with voxel sizes 0.51 mm × 0.51 mm × 1 mm were used in analysis. Among the 49 calculations, the maximum rotation angle differences were 0.1 degree, 0.15 degree, and 0.09 degree, for pitch, roll, and couch rotation, respectively. The mean ± standard-deviation angle differences were 0.028±0.001 degree, −0.043±0.003 degree, and −0.009±0.001 degree, for pitch, roll, and couch rotation, respectively. The maximum isocenter shifts were 0.3 mm, 0.5 mm, 0.4 mm in x, y, z direction respectively following IEC6127 convention. The mean isocenter shifts were 0.07±0.02 mm, −0.05±0.06 mm, and −0.12±0.02 mm in x, y and z directions. Conclusion The accuracy of the Varian PerfectPitch six DOF couch was studied with CBCTs of the Isocal phantom. The rotational errors were less than 0.15 degree and isocenter shifts were less than 0.5 mm in any direction. This accuracy is sufficient for stereotactic radiotherapy clinical applications.

60 APPLIED LIFE SCIENCES↗

WE-AB-303-05: Breathing Motion of Liver Segments From Fiducial Tracking During Robotic Radiosurgery and Comparison with 4D-CT-Derived Fiducial Motion

Purpose: To quantify respiratory-induced motion of liver segments using the positions of implanted fiducials during robotic radiosurgery. This study also compared fiducial motion derived from four-dimensional computed tomography (4D-CT) maximum intensity projections (MIP) with motion derived from imaging during treatment. Methods: Forty-two consecutive liver patients treated with liver ablative radiotherapy were accrued to an ethics approved retrospective study. The liver segment in which each fiducial resided was identified. Fiducial positions throughout each treatment fraction were determined using orthogonal kilovoltage images. Any data due to patient repositioning or motion was removed. Mean fiducial positions were calculated. Fiducial positions beyond two standard deviations of the mean were discarded and remaining positions were fit to a line segment using least squares minimization (LSM). For eight patients, fiducial motion was derived from 4D-CT MIPs by calculating the CT number weighted mean position of the fiducial on each slice and fitting a line segment to these points using LSM. Treatment derived fiducial trajectories were corrected for patient rotation and compared to MIP derived trajectories. Results: The mean total magnitude of fiducial motion across all liver segments in left-right, anteroposterior, and superoinferior (SI) directions were 3.0 ± 0.2 mm, 9.3 ± 0.4 mm, and 20.5 ± 0.5 mm, respectively. Differences in per-segment mean fiducial motion were found with SI motion ranging from 12.6 ± 0.8 mm to 22.6 ± 0.9 mm for segments 3 and 8, respectively. Large, varied differences between treatment and MIP derived motion at simulation were found with the mean difference for SI motion being 2.6 mm (10.8 mm standard deviation). Conclusion: The magnitude of liver fiducial motion was found to differ by liver segment. MIP derived liver fiducial motion differed from motion observed during treatment, implying that 4D-CTs may not accurately capture the range of liver motion across fractions and during treatment. Author V. Nair was funded by the Cushing estate for a SABR clinical research fellowship.

60 APPLIED LIFE SCIENCES↗

Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-11: A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-To-End Test System

Purpose: A novel end-to-end test system using a CCD camera and a scintillator based phantom (XRV-124, Logos Systems Int’l) capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery (CyberKnife) was developed and reported in our previous work. This work investigates its application in assessing the motion tracking (Synchrony) accuracy for CyberKnife. Methods: A QA plan with Anterior and Lateral beams (with 4 different collimator sizes) was created (Multiplan v5.3) for the XRV-124 phantom. The phantom was placed on a motion platform (superior and inferior movement), and the plans were delivered on the CyberKnife M6 system using four motion patterns: static, Sine- wave, Sine with 15° phase shift, and a patient breathing pattern composed of 2cm maximum motion with 4 second breathing cycle. Under integral recording mode, the time-averaged beam vectors (X, Y, Z) were measured by the phantom and compared with static delivery. In dynamic recording mode, the beam spots were recorded at a rate of 10 frames/second. The beam vector deviation from average position was evaluated against the various breathing patterns. Results: The average beam position of the six deliveries with no motion and three deliveries with Synchrony tracking on ideal motion (sinewave without phase shift) all agree within −0.03±0.00 mm, 0.10±0.04, and 0.04±0.03 in the X, Y, and X directions. Radiation beam width (FWHM) variations are within ±0.03 mm. Dynamic video record showed submillimeter tracking stability for both regular and irregular breathing pattern; however the tracking error up to 3.5 mm was observed when a 15 degree phase shift was introduced. Conclusion: The XRV-124 system is able to provide 3D and 4D targeting accuracy for CyberKnife delivery with Synchrony. The experimental results showed sub-millimeter delivery in phantom with excellent correlation in target to breathing motion. The accuracy was degraded when irregular motion and phase shift was introduced.

60 APPLIED LIFE SCIENCES↗

Robotic Intelligence Kernel: Driver

The INL Robotic Intelligence Kernel-Driver is built on top of the RIK-A and implements a dynamic autonomy structure. The RIK-D is used to orchestrate hardware for sensing and action as well as software components for perception, communication, behavior and world modeling into a single cognitive behavior kernel that provides intrinsic intelligence for a wide variety of unmanned ground vehicle systems.

Bruemmer, DavidJ.↗

nanoPOTS robot

In conjunction with other nanoPOTS related IP, we are disclosing the robotic platform including specific parts used to construct the nanopipetting instrument.

Zhu, Ying↗

Robot-Alignment

Fermilab's SRF Robotics group's automated alignment program. FERMILAB-CODE-2026-03-TD

Giffen, Nickolas [Northern Illinois Univ., DeKalb,↗

Adapting a Low-Cost and Open-Source Commercial Pipetting Robot for Nanoliter Liquid Handling

Nanoliter liquid handling capabilities in bioanalytical workflows can reduce reagent costs and improve sample processing efficiency. Here we report the successful modification of a low-cost commercially available pipetting robot, the Opentrons 1 (OT1), using inexpensive 3D-printed parts to accommodate low-nanoliter volumes. The pipetting accuracy and precision of the modified OT1 for 50 nL volumes of water was 0.2% and 2%, respectively. The accuracy and precision at 20 nL was 1% and 3.8%, respectively. The platform was successfully applied to the preparation of low-nanogram proteomic samples for liquid chromatography-mass spectrometry analysis. The modified OT1 is thus an effective platform for nanoliter liquid handling and, at a total cost of less than $6000 including the commercial liquid handler and all modifications, is far less expensive and more versatile than other platforms with similar capabilities, placing this technology within reach of a far broader scientific community.

47 OTHER INSTRUMENTATION↗

Robot deployable air sampling development suite

Many areas exist within the DOE EM complex where it is desired to obtain a better understanding of the environment through the use of sensors. Many of these areas are hazardous and/or inaccessible to humans requiring the development of capabilities and technologies to remotely access these areas for monitoring. Often it is desired to understand the air quality and basic environmental parameters of these inaccessible areas. The focus this LDRD was to identify and procure air and environmental sampling sensors of common interest to DOE facilities such as pH, Nitric Acid Concentration (NOx), humidity, temperature, and air velocity. Additionally, it was desired to procure a robotic platform as a basis developing a remotely deployable air sampling suite.

54 ENVIRONMENTAL SCIENCES↗

Development of a Visualization Concept for Robotic Operations to Consolidate Commercial Spent Nuclear Fuel

Sandia and NAC are advancing a new conceptual initiative associated with integrating the back end of the nuclear fuel cycle. Sandia has robust capability in robotics and spent fuel disposal science and engineering. NAC has demonstrated rod consolidation packaging technology that potentially enables more efficient nuclear fuel cycle back end integration. NAC also has a robust capability in spent fuel packaging.

Freeze, Geoffrey↗

Drones, Delivery Robots, Driverless Cars, and Intelligent Curbs for Increasing Energy Productivity of First/Last Mile Goods Movement

The objective of the project is to use empirical testing, life cycle assessment, and systems analysis to research and demonstrate energy improvement when using goods delivery drones, eVTOL, ground delivery robots and automated vehicles compared to a baseline network. The research will also develop proof-of-concept testing, a model, and simulation for a smart curb space as an intelligently-managed urban delivery zone demonstrating additional improvement in energy productivity.

Scherer, Sebastian↗

Robotic Staffing Augmentation

The Robotic Augmentation & Novel Applications team at Los Alamos National Laboratory is working to produce autonomous systems to augment staffing for tasks that are tedious, dangerous, or require high precision. This is intended to reduce risks to staff, programs and facilities while also freeing up personnel resources to better support laboratory missions, particularly pit manufacturing. The primary focus of this effort is to utilize cutting edge automation to augment long duration radiation surveys, allowing RCTs to work on critical production activities.

42 ENGINEERING↗

Wearable robotics could save the day (and your back)

How can a lightweight back-assisted exosuit help material handlers decrease back strain from repetitive lifting tasks? What are the benefits of a passive robotic shoulder support in reducing fatigue and injury for environmental cleanup workers? How can mechanical devices reduce joint and muscle injuries in a manufacturing environment? These are some of the questions a group of Laboratory engineers are asking in their ongoing quest to identify and evaluate specially designed wearable advanced technologies to assist workers and help keep them safe.

42 ENGINEERING↗

Arc Weld Robotic Arm & Enclosure Seismic Anchorage in B226

The Arc Weld Robotic Arm & Enclosure is adequately anchored by the details shown on sheets SKS-01 through SKS-03. Two different Hilti anchors have been provided to allow for installation flexibility. Existing documentation shows that the existing enclosure base has been anchored with 5/8”Ø Kwik Bolt TZ’s. As a result, it is believed that the existing holes are sized for that 5/8”Ø anchor. The first option is to install a 5/8”Ø Kwik Bolt TZ2, similarly to the existing conditions. The second option is to use a threaded insert anchor. Since the largest allowable diameter of HIS-N insert is 1/2”Ø based on the slab thickness, 2”x2” square plate washers with a 9/16”Ø hole will need to be installed on the top of the existing enclosure base plates to reduce the diameter of the existing holes. This is required for the anchorage to provide proper restraint in a seismic event.

42 ENGINEERING↗

Robotic Assembly of Multi-Chip Modules Using Artificial Intelligence

With many properties of dark matter remaining a mystery, the OSCURA experiment aims to detect light dark matter particles using 1,536 Multi-Chip Modules (MCMs), containing a total of 24,576 skipper CCDs. Currently, each MCM is assembled by hand a time-consuming and error-prone process that can be automated. In this ongoing work, we present an automated assembly robot that leverages modern computer vision and artificial intelligence to assemble the OSCURA MCMs. This approach reduces cost, time, and error in the packaging of OSCURA sensors.

Arteaga, Matthew [Northern Illinois U.; Fermilab]↗

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]↗