Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFETY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Tungsten monoblock concepts for the Fusion Nuclear Science Facility (FNSF) first wall and divertor

Next-step fusion nuclear devices require plasma-facing components that can survive a much higher neutron dose than ITER, and in many design concepts also require higher operating temperatures, higher reliability, and materials with more attractive safety and environmental characteristics. In search of first wall concepts that can withstand surface heat fluxes beyond 2 MW/m 2 , we analyzed advanced “monoblock” designs using coolants and materials that offer more attractive long-term performance. These use tungsten armor and heat sinks, similar to previous designs, but replace the coolant with helium and the coolant containment pipe with either low-activation ferritic-martensitic steel or SiC/SiC composite. The results of analysis show that helium-cooled steel can remove up to 5 MW/m 2 of steady-state surface heat flux and helium-cooled SiC/SiC can remove nearly 10 MW/m 2 while satisfying all materials and design requirements. This suggests that a He-cooled W/SiC monoblock could withstand divertor-like heat fluxes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B, for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.

Wang, Yijia↗

A Fully Ordered Triplite, LiCuSO 4 F

Batteries are a major technological challenge in this new century, as they stand as a key way to make a more efficient use of energy. Rechargeable Li-ion batteries, by having the highest energy density of any such device, have emerged as the technology of choice for powering electric vehicles and show great promises for grid applications. For such promises to materialize fully, the quest for new positive electrode materials showing safety, sustainability and cost advantages must continue. Here, progresses have been recently achieved with the arrival of polyanionic compounds. Among them, LiFePO 4 is the most attractive, although its energy density is penalized by the low redox voltage (3.45 V vs Li + /Li 0 ) of the Fe 3+ /Fe 2+ redox couple.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiological source tracking in oil/gas, medical and other industries: requirements and specifications for passive RFID technology

Subsurface sensors that employ radioisotopes, such 241Am-Be and 137Cs, for reservoir characterization must be tracked for safety and security reasons. Other radiological sources are also widely used in medicine. The radiological source containers, in both applications, are small, mobile and used widely worldwide. The nuclear sources pose radiological dispersal device (RDD) security risks. Security concerns with the industrial use of radionuclide sources is in fact quite high as it is estimated that each year hundreds of sealed sources go missing, either lost or stolen. Risk mitigation efforts include enhanced regulations, source-use guidelines, research and development on electronic tracking of sources. This report summarizes the major elements of the requirements and operational concepts of nuclear sources with the goal of developing automated electronic tagging and locating systems.

42 ENGINEERING↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emulating Variable Uranium Enrichments With Radiation Signature Training Devices (RSTD)

Radiological signature training devices (RSTDs) are sealed sources (or assemblies of sources) that emulate the radiation signature of larger masses of special nuclear material for passive detection while maintaining a minimal logistical footprint in security, radiological safety, criticality safety, and transportation requirements. Previous work focused on emulation of large quantities of highly enriched uranium for search and field identification with radioisotope identification detectors and mobile systems. New work has expanded into investigating use of the RSTDs with laboratory safeguards tools, such as MGAU and FRAM, and emulating uranium spectra of multiple enrichments over more energy regions (particularly the x-ray region).

Blessinger, Christopher S.↗

All-solid-state supercapacitors on silicon using graphene from silicon carbide

Carbon-based supercapacitors are lightweight devices with high energy storage performance, allowing for faster charge-discharge rates than batteries. Here, we present an example of all-solid-state supercapacitors on silicon for on-chip applications, paving the way towards energy supply systems embedded in miniaturized electronics with fast access and high safety of operation. We present a nickel-assisted graphitization method from epitaxial silicon carbide on a silicon substrate to demonstrate graphene as a binder-free electrode material for all-solid-state supercapacitors. We obtain graphene electrodes with a strongly enhanced surface area, assisted by the irregular intrusion of nickel into the carbide layer, delivering a typical double-layer capacitance behavior with a specific area capacitance of up to 174 μF cm{sup −2} with about 88% capacitance retention over 10 000 cycles. The fabrication technique illustrated in this work provides a strategic approach to fabricate micro-scale energy storage devices compatible with silicon electronics and offering ultimate miniaturization capabilities.

36 MATERIALS SCIENCE↗

SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm{sup 2}) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

60 APPLIED LIFE SCIENCES↗

The effect of residual palladium on the performance of organic electrochemical transistors

Organic electrochemical transistors are a promising technology for bioelectronic devices, with applications in neuromorphic computing and healthcare. The active component enabling an organic electrochemical transistor is the organic mixed ionic-electronic conductor whose optimization is critical for realizing high-performing devices. In this study, the influence of purity and molecular weight is examined for a p-type polythiophene and an n-type naphthalene diimide-based polymer in improving the performance and safety of organic electrochemical transistors. Our preparative GPC purification reduced the Pd content in the polymers and improved their organic electrochemical transistor mobility by ~60% and 80% for the p- and n-type materials, respectively. These findings demonstrate the paramount importance of removing residual Pd, which was concluded to be more critical than optimization of a polymer’s molecular weight, to improve organic electrochemical transistor performance and that there is readily available improvement in performance and stability of many of the reported organic mixed ionic-electronic conductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARIES-ACT1 Safety Design and Analysis

ARIES-ACT1 (Advanced and Conservative Tokamak) is a 1000-MW(electric) tokamak design featuring advanced plasma physics and divertor and blanket engineering. Some relevant features include an advanced SiC blanket with PbLi as coolant and breeder; a helium-cooled steel structural ring and tungsten divertors; a thin-walled, helium-cooled vacuum vessel; and a room-temperature, water-cooled shield outside the vacuum vessel. We consider here some safety aspects of the ARIES-ACT1 design and model a series of design-basis and beyond-design-basis accidents with the MELCOR code modified for fusion. The presence of multiple coolants (PbLi, helium, and water) makes possible a variety of such accidents. We consider here a loss-of-flow accident caused by a long-term station blackout (LTSBO), an ex-vessel helium break into the cryostat, and a beyond-design-basis accident in which a LTSBO is aggravated by a loss-of-coolant accident in ARIES-ACT1's ultimate decay heat removal system, the water-cooled shield. In the design-basis accidents, we find that the secondary confinement boundaries are not challenged, and the structural integrity of in-vessel components is not threatened by high temperatures or pressures; decay heat can be passively removed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of a marine animal alert system to support Marine Renewable Energy

Power extracted from fast moving tidal currents has been identified as a potential commercial-scale source of renewable energy. Device developers and utilities are pursuing deployment of prototype tidal turbines to assess technology viability, site feasibility, and environmental interactions. Deployment of prototype turbines requires permits from a range of regulatory authorities. Ensuring the safety of marine animals, particularly those under protection of the Endangered Species Act of 1973 (ESA) and the Marine Mammal Protection Act of 1972 has emerged as a key regulatory challenge for initial MHK deployments. The greatest perceived risk to marine animals is from strike by the rotating blades of tidal turbines. Development of the marine mammal alert system (MAAS) was undertaken to support monitoring and mitigation requirements for tidal turbine deployments. The prototype system development focused on Southern Resident killer whales (SRKW), an endangered population of killer whales that frequents Puget Sound and is intermittently present in the part of the sound where deployment of prototype tidal turbines is being considered. Passive acoustics were selected as the primary means because of the vocal nature of these animals. The MAAS passive acoustic system consists of two-stage process involving the use of an energy detector and a spectrogram-based classifier to distinguish between SKRW’s calls and noise. A prototype consisting of two 2D symmetrical star arrays separated by 20 m center to center was built and evaluated in the waters of Sequim Bay using whale call playback.

killer whales↗

Radiation Safety Consideration for the Parasitic Final Focus Test Beam at SLAC

A low intensity electron beam parasitic to the operation of the Stanford Linear Collider (SLC) has been transported through the Final Focus Test Beam (FFTB) facility making secondary test beams available for users. Photons generated in collimation of the SLC electron and positron beams in the linac pass through a splitter magnet that deflects the primary beams away from the linac axis into the SLC beam lines. These photons are converted to electrons and positrons in a secondary production target located down beam on the hnac axis. The secondary electrons are then transported through the FFTB beam line onto experimental detectors. The average power of the parasitic beam is very low, thus, it presents no hazards. However, various accident scenarios involving failure of the splitter magnet and the active protection devices could send much more powerful SLC beams (up to 90 kilo-watts) into this zero-degree secondary beam line. For the accident case, the average power in the transmitted beam was calculated using the Monte Carlo programs EGS4 and TURTLE. Results from analysis of the radiation protection systems that assure safety during the parasitic operation are presented.

Rokni, S. H.↗

Relay Protection and Automation Systems Based on Programmable Logic Integrated Circuits

One of the most promising forms of developing the apparatus part of relay protection and automation devices is considered. The advantages of choosing programmable logic integrated circuits to obtain adaptive technological algorithms in power system protection and control systems are pointed out. The technical difficulties in the problems which today stand in the way of using relay protection and automation systems are indicated and a new technology for solving these problems is presented. Particular attention is devoted to the possibility of reconfiguring the logic of these devices, using programmable logic integrated circuits.

42 ENGINEERING↗

Digitizing and Enhancing Accessibility of the Fusion Safety Archives

This project focuses on the digitization and public accessibility to the Fusion Safety Archives at the Idaho National Laboratory. The first phase involves a thorough review of each document in the physical archives to determine its online availability. For documents that are available online, PDF copies and unique identifiers are collected for database integration. Documents not available online are delivered to Red Inc. for digitization. Additionally, defunct storage devices such as diskettes are sent to INL’s archival department for data retrieval where possible. The second phase of the project involves the creation of a comprehensive database to house the digital copies of the archives. The database will facilitate easy access and management of the digitized documents. Following the database creation, we plan to train a Retrieval-Augmented Generation (RAG) based AI on publicly available documents. The trained AI will be integrated into a front-facing application, allowing the public to easily access information from the Fusion Safety Archives. This project aims to preserve valuable historical data, improve accessibility, and promote transparency in fusion safety research.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ and Ex Situ NMR for Battery Research

A rechargeable battery stores readily convertible chemical energy to operate a variety of devices such as mobile phones, laptop computers, and electric automobiles, etc. A battery generally consists of four components, i.e., a cathode, an anode, a separator and electrolytes. The properties of these components jointly determine the safety, the lifetime, and the electrochemical performance, include but not limited to the power density and the charge, recharge time/rate associated with a battery system. Extensive amount of research is thus dedicated to understand the physical and chemical properties associated with each of the four components aimed at developing new generations of battery systems with greatly enhanced safety and electrochemical performance while at significantly reduced cost for large scale applications. Advanced characterization tools are prerequisite to fundamentally understand battery materials. Considering that some of the key electrochemical processes can only exist under in situ conditions, thus, can only be captured under a working battery conditions when electric wires are attached and current and voltage applied, in situ detection is critical. NMR, a non-invasive and atomic specific tool, is capable of detecting all phases, including crystalline, amorphous, liquid and gaseous phases simultaneously and is ideal for in situ detection on a working battery system. Ex situ NMR on the other hand can provide more detailed molecular or structural information on stable species with better spectral resolution and sensitivity. The combination of in situ and ex situ NMR, thus, offers a powerful tool for investigating the detailed electrochemistry in batteries.

Energy storage, batteries, multi nuclear NMR, 7Li,↗

Experimental energy confinement time scaling with dimensionless parameters in C-Mod I-mode plasmas

The dependence of energy confinement time on gyroradius, β, and normalized collisionality in I-mode plasmas is investigated through dedicated C-Mod experiments scanning dimensionless parameters with constant safety factor. The gyroradius scaling is calculated to be Ω τE ∝ ρ * -3.9±1.5 , which suggests core transport may scale with gyro–Bohm physics, indicating favorable extrapolation of the I-mode regime to future devices at low ρ * . The scaling exponent for ν C is calculated to be small, but positive (Ω τE ∝ ν $^{0.44 ± 0.24}_{C}$), and the exponent for β is deemed inconclusive (Ω τE ∝ β 1.4±3.1 ) due to high correlation with the other two dimensionless variables in the dataset, and therefore requires further investigation. The individual dimensionless parameter scaling is compared to calculations from larger C-Mod I-mode datasets as well as multi-machine scaling laws for ELMy H-mode and L-mode plasmas. Finally, multiple regression techniques and principal component analysis are used to clarify the single parameter scalings and analyze parameter significance within the dataset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of divertor heat flux width for ITER pre-fusion power operation using BOUT++ transport code

Prediction of divertor heat flux width is performed for the first and the second pre-fusion power operation (PFPO) phases specified in the new ITER research plan using BOUT++ transport code (Li et al 2018 Comput. Phys. Commun.228 69–82). Here the initial plasma profiles inside the separatrix are taken from CORSICA scenario studies. Transport coefficients in transport code are calculated by inverting the plasma profiles inside the separatrix and are assumed to be constants in the scrape-off-layer. An anomalous thermal diffusivity scan is performed with E × B and magnetic drifts. The results in two scenarios identifying two distinct regimes: a drift-dominant regime when diffusivity is smaller than the respective critical thermal diffusivity χ c and a turbulence-dominant regime when diffusivity is larger than it. The Goldston heuristic drift model and the ITPA multi-machine experimental scaling yield a lower limit of the width λ q . From transport simulations, we obtain the critical thermal diffusivity χ c = 0.5 m 2 s –1 for the PFPO-1 scenario with toroidal magnetic field B = 1.77 T and plasma current I p = 5 MA, and χ c = 0.3 m 2 s –1 for the PFPO-2 scenario with toroidal magnetic field B = 2.65 T and plasma current I p = 7.5 MA. Separatrix temperature and collisionality also have a significant impact on the heat flux width in the drift-dominant regime. The investigation clearly yields a scaling for critical thermal diffusivity ${\chi }_{\text{c}}\propto {A}^{1/2}/(Z{\left(1+Z\right)}^{\frac{1}{2}}{B}_{\text{p}}^{2})$ using ITER scenarios with fixed safety factor q 95 , major radius R, aspect ratio R/a, and the separatrix temperature T sep , and establishes the connection with CFETR and C-Mod discharges. This scaling implies that for a given tokamak device with q 95 , R, R/a, and T sep fixed, a reduction of poloidal magnetic field by a factor of 3 leads to a 9 times higher critical value of thermal diffusivity χ c , possibly yielding a transition from turbulence- to drift-dominant regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗