Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Anomalous low-temperature magnetoresistance dips in sputtered ferromagnetic thin films and multilayers

A set of ferromagnetic thin films and multilayers containing 3d metals (Fe, Co) in different amounts was prepared by rf sputtering. Each sample exhibits a specific magnetic and magnetoresistive behavior, as expected for materials having different saturation magnetizations, magnetic anisotropies, and surface-to-volume ratios. From room temperature down to about 10 K, the magnetoresistance is explained in terms of well-known mechanisms; at low fields, a negative magnetoresistance is measured. Between {approx}10 and 30 K, the zero-field electrical resistance appears to be dominated by electron-phonon scattering. At lower temperatures, where the R vs T curve is almost saturated, a sudden drop of the resistance appears, whose magnitude and position vary from sample to sample. Below the drop temperature, a region of positive magnetoresistance is systematically observed at around H=0 in measurements done with the magnetic field applied either parallel or perpendicular to the film plane. The dip magnitude increases with decreasing temperature. The anomaly appears to be related to the presence of magnetic inhomogeneity in the samples. The experimental results are not explained in terms of standard magnetoresistance mechanisms. Effects related to quantum coherence of conduction electrons may be the source of the observed anomalies. The role of weak localization of electrons, inhibited by the additional scattering provided by the magnetic inhomogeneity on the nanometer scale, is discussed.

36 MATERIALS SCIENCE↗

Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoscale defect detection by heterodyne interferometry

We construct an instrument that facilitates the measurement of nanoscale defects. It is based on heterodyne interferometry with phase measurement that utilizes a polarizing beam splitter to form a measuring signal and an oscillating cantilever tip that acts as a scanning probe to get the measurement values of sample topography. The dependence of the tip displacement on the variation of tip-sample distance and the comb scanning of the sample topography are investigated by experiments. The results prove that the tip displacement increases and is enough to be discriminated in various positions where the sample is approached. The system has been successfully utilized to measure the defect characterization by measuring the pitch of the standard sample. The results also show that the heterodyne system has good repeatability, a large measurement range, and high accuracy, with a measurement stability of 0.5 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Downhole Elemental Analysis with LIBS

In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a vertical stage; a second actuator at the top of the downhole probe allows radial scanning of the borehole. Analysis of iron and titanium in lunar simulant with LIBS was performed in air using the method of standard addition. The results for lunar simulant NU-LHT-2M show a value for the concentration of iron ranging between 2.29% and 3.05% depending on the atomic line selected. The accepted value for the sample analyzed is 2.83%, showing the capability for the system in development to provide qualitative and semi-quantitative analysis in real-time.

Moreschini, Paolo↗

Atmospheric deposition of {sup 7}Be by rain events, incentral Argentina

Beryllium-7 is a natural radionuclide that enters into the ecosystems through wet and dry depositions and has numerous environmental applications in terrestrial and aquatic ecosystems. Atmospheric wet deposition of {sup 7}Be was measured in central Argentina. Rain traps were installed (1 m above ground) and individual rain events have been collected. Rain samples were filtered and analyzed by gamma spectrometry. The gamma counting was undertaken using a 40%-efficient p-type coaxial intrinsic high-purity natural germanium crystal built by Princeton Gamma-Tech. The cryostat was made from electroformed high-purity copper using ultralow-background technology. The detector was surrounded by 50 cm of lead bricks to provide shielding against radioactive background. The detector gamma efficiency was determined using a water solution with known amounts of chemical compounds containing long-lived naturally occurring radioisotopes, {sup 176}Lu, {sup 138}La and {sup 40}K. Due to the geometry of the sample and its position close to the detector, the efficiency points from the {sup 176}Lu decay, had to be corrected for summing effects. The measured samples were 400 ml in size and were counted curing one day. The {sup 7}Be detection limit for the present measurements was as low as 0.2 Bq l{sup -1}. Thirty two rain events were sampled and analyzed (November 2006-May 2007). The measured values show that the events corresponding to low rainfall (<20 mm) are characterized by significantly higher activity concentrations (Bq l{sup -1}). The activity concentration of each individual event varied from 0.8 to 3.5 Bq l{sup -1}, while precipitations varied between 4 and 70 mm. The integrated activity by event of {sup 7}Be was fitted with a model that takes into account the precipitation amount and the elapsed time between two rain events. The integrated activities calculated with this model show a good agreement with experimental values.

54 ENVIRONMENTAL SCIENCES↗

Thermophysical analysis of II-VI semiconductors by PPE calorimetry and lock-in thermography

An accurate determination of thermophysical properties such as thermal diffusivity, thermal effusivity and thermal conductivity is extremely important for characterization and quality assurance of semiconductors. Thermal diffusivity and effusivity of some binary semiconductors have been investigated. Two experimental techniques were used: a contact technique (PPE calorimetry) and a non contact technique (lock-in thermography). When working with PPE, in the back (BPPE) configuration and in the thermally thick regim of the pyroelectric sensor, we can get the thermal diffusivity of the sample by performing a scanning of the excitation frequency of radiation. Thermal effusivity is obtained in front configuration (sensor directly irradiated and sample in back position) by performing a thickness scan of a coupling fluid. By using the lock-in thermography technique, the thermal diffusivity of the sample is obtained from the phase image. The results obtained by the two techniques are in good agreement. Nevertheless, for the determination of thermal diffusivity, lock-in thermography is preferred.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circular RNA expression and circPTPRM promotes proliferation and migration in hepatocellular carcinoma

Circular RNAs (circRNAs) play a critical role during hepatocellular carcinoma (HCC) development. CircRNA PTPRM (circPTPRM) has not been reported to cause disease and its role in HCC is unclear. This study explored circRNA expression and the function of circPTPRM in HCC. RNA sequencing (RNA-seq) was performed on 3 randomly selected pairs of HCC tissues and their corresponding adjacent non-tumor tissues. Three differentially expressed circRNAs, circPTPRM, circSMAD2 and circPTBP3 were selected and verified by real-time quantitative reverse transcription-polymerase chain reactions in 30 pairs of tissue samples, In vitro cultured hepatoma cells, and normal liver cells. Clinical data analysis was performed to select target circRNAs. Anti-target circRNA siRNAs were transfected into hepatoma cell lines, and the biological behavior of hepatoma cells following silencing of the target circRNA were detected by cell proliferation, plate cloning, and transwell assays. There were 86 differentially expressed circRNAs from RNA-seq, of which 53 were significantly upregulated and 33 were significantly downregulated in HCC. CircPTPRM expression was significantly upregulated in HCC tissue (p = 0.023) based on the analysis of 30 paired samples. CircPTPRM expression positively correlated with HCC recurrence and metastasis (p = 0.039). CircPTPRM silencing reduced HCC cell proliferation, migration and invasion. CircRNAs were differentially expressed in HCC samples. CircPTPRM was significantly upregulated in HCC and may function during the tumorigenesis and metastasis of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Receiver Operating Characteristic Curves to Optimize Discovery-Based Software with Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry

We report a quantitative approach to optimize implementation of discovery-based software for comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS). The software performs a tile-based Fisher ratio (F-ratio) analysis, and facilitates a supervised non-targeted analysis based upon the experimental design to aid in the discovery of analytes whose variances are statistically different between sample classes. The quantitative approach for software optimization uses receiver operating characteristic (ROC) curves. The area under the curve (AUC) of each ROC curve serves as a quantitative metric to optimize two key algorithm parameters: the signal-to-noise ratio (S/N) threshold of the baseline corrected and normalized data prior to calculating F-ratios at each m/z mass channel, and the number of these F-ratios per m/z to include in the calculation of the average F-ratio of a tile. A total of 25 combinations of S/N threshold by number of m/z were studied. Fifty analytes were spiked into a diesel fuel at two concentration spike levels to produce two sample classes that should in principle produce 50 positive instances in the ROC curves (30 native/20 non-native compounds, at spike levels of 200/20 and100/10 ppm native/non-native, respectively). The “sweet spot” for F-ratio analysis was determined to be a S/N threshold of 10 coupled with a maximum of the 10 most chemically selective m/z (requiring a minimum of 3 m/z), corresponding to a ~ 21% improvement in the discovery rate of true positives relative to prior studies. Furthermore, it was observed that optimization of these software parameters did not depend upon a priori determination of the statistically correct number of positive instances in the sample classes. The AUC metric appears to be suitable for the evaluation of all data analysis methods that utilize the proper experimental design.

3D-GS/TOFMS, Data discovery, ROC curves, Fisher ra↗

DESI DR2 results. I. Baryon acoustic oscillations from the Lyman alpha forest

We present the baryon acoustic oscillation (BAO) measurements with the Lyman-𝛼 (Ly⁢𝛼) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the autocorrelation of the Ly⁢𝛼 forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of 2 larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped Ly⁢𝛼 absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at 𝑧 eff =2.33. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in Ly⁢𝛼 BAO analysis for the first time. We measure the ratios 𝐷 𝐻 ⁡(𝑧 eff )/𝑟 𝑑 = 8.632 ± 0.098 ± 0.026 and 𝐷 𝑀 ⁡(𝑧 eff )/𝑟 𝑑 = 38.99 ± 0.52 ± 0.12, where 𝐷 𝐻 = 𝑐/𝐻⁡(𝑧) is the Hubble distance, 𝐷 𝑀 is the transverse comoving distance, 𝑟 𝑑 is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

baryon acoustic oscillations↗

Characterization of a cold cathode Penning ion source for the implantation of noble gases beneath 2D monolayers on metals: Ions and neutrals

Argon ion kinetic energy spectra at different discharge voltages (between 480 and 600 V) of a commercial cold cathode ion source IQP10/63 are reported. The high kinetic energy cut-off depends on the discharge voltage and the corresponding plasma potential due to excess positive charges which is found to be about 136 V. Exposure of single layer hexagonal boron nitride on rhodium to the beam of the ion source leads to the formation of nanotents, i.e., stable atomic protrusions. A positive bias voltage is applied to the target sample to block the positive ions produced by the ion source. However, application of a positive bias potential (800 eV), which is higher than the kinetic energy cut-off, still allows the formation of nanotents and its observation with scanning tunneling microscopy. This indicates that the ion source also produces neutral atoms with kinetic energies higher than the penetration threshold across a single layer of hexagonal boron nitride.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-68: A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy

Purpose: The purpose of this work was to develop a quality assurance (QA) system for high dose rate (HDR) brachytherapy to verify the absolute position of an 192Ir source in real time and to measure dwell time and position of the source simultaneously with a movie recorded by a web camera. Methods: A web camera was fixed 15 cm above a source position check ruler to monitor and record 30 samples of the source position per second over a range of 8.0 cm, from 1425 mm to 1505 mm. Each frame had a matrix size of 480×640 in the movie. The source position was automatically quantified from the movie using in-house software (built with LabVIEW) that applied a template-matching technique. The source edge detected by the software on each frame was corrected to reduce position errors induced by incident light from an oblique direction. The dwell time was calculated by differential processing to displacement of the source. The performance of this QA system was illustrated by recording simple plans and comparing the measured dwell positions and time with the planned parameters. Results: This QA system allowed verification of the absolute position of the source in real time. The mean difference between automatic and manual detection of the source edge was 0.04 ± 0.04 mm. Absolute position error can be determined within an accuracy of 1.0 mm at dwell points of 1430, 1440, 1450, 1460, 1470, 1480, 1490, and 1500 mm, in three step sizes and dwell time errors, with an accuracy of 0.1% in more than 10.0 sec of planned time. The mean step size error was 0.1 ± 0.1 mm for a step size of 10.0 mm. Conclusion: This QA system provides quick verifications of the dwell position and time, with high accuracy, for HDR brachytherapy. This work was supported by the Japan Society for the Promotion of Science Core-to-Core program (No. 23003)

60 APPLIED LIFE SCIENCES↗

DESI DR2 Results I: Baryon Acoustic Oscillations from the Lyman Alpha Forest

We present the Baryon Acoustic Oscillation (BAO) measurements with the Lyman-alpha (LyA) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the auto-correlation of the LyA forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of two larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped LyA absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at $z_{eff} = 2.33$. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in LyA BAO analysis for the first time. We measure the ratios $D_H(z_{eff})/r_d = 8.632 \pm 0.098 \pm 0.026$ and $D_M(z_{eff})/r_d = 38.99 \pm 0.52 \pm 0.12$, where $D_H = c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, $r_d$ is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Stress-induced subclinical reactivation of varicella zoster virus in astronauts

Varicella zoster virus (VZV) becomes latent in human ganglia after primary infection. VZV reactivation occurs primarily in elderly individuals, organ transplant recipients, and patients with cancer and AIDS, correlating with a specific decline in cell-mediated immunity to the virus. VZV can also reactivate after surgical stress. The unexpected occurrence of thoracic zoster 2 days before space flight in a 47-year-old healthy astronaut from a pool of 81 physically fit astronauts prompted our search for VZV reactivation during times of stress to determine whether VZV can also reactivate after non-surgical stress. We examined total DNA extracted from 312 saliva samples of eight astronauts before, during, and after space flight for VZV DNA by polymerase chain reaction: 112 samples were obtained 234-265 days before flight, 84 samples on days 2 through 13 of space flight, and 116 samples on days 1 through 15 after flight. Before space flight, only one of the 112 saliva samples from a single astronaut was positive for VZV DNA. In contrast, during and after space flight, 61 of 200 (30%) saliva samples were positive in all eight astronauts. No VZV DNA was detected in any of 88 saliva samples from 10 healthy control subjects. These results indicate that VZV can reactivate subclinically in healthy individuals after non-surgical stress. Copyright 2004 Wiley-Liss, Inc.

Astronauts↗

Stress-Induced Subclinical Reactivation of Varicella Zoster Virus in Astronauts

After primary infection, varicella-zoster virus (VZV) becomes latent in ganglia. VZV reactivation occurs primarily in elderly individuals, organ transplant recipients, and patients with cancer and AIDS, correlating with a specific decline in cell-mediated immunity to VZV. VZV can also reactivate after surgical stress. To determine whether VZV can also reactivate after acute non-surgical stress, we examined total DNA extracted from 312 saliva samples of eight astronauts before, during and after space flight for VZV DNA by PCR: 112 samples were obtained 234 to 265 days before flight, 84 samples on days 2 through 13 of space flight, and 116 samples on days 1 through 15 after flight. Before space flight only one of the 112 saliva samples from a single astronaut was positive for VZV DNA. In contrast, during and after space flight, 61 of 200 (30%) saliva samples were positive in all 8 astronauts. No VZV DNA was detected in any of 88 saliva samples from 10 healthy control subjects. These data indicate that VZV can reactivate subclinically in healthy individuals after acute stress.

Mehta, Satish K.↗

Soft Real-Time PID Control on a VME Computer

microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

Karayan, Vahag↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Note: A simple charge neutralization method for measuring the secondary electron yield of insulators

We report on a simple and effective charge neutralization method for measuring the total electron-induced secondary electron yield of insulators in a measurement system with a single pulsed electron gun. In this method, the secondary electron collector is negatively biased with respect to the sample to force some emitted secondary electrons to return to the sample surface and therefore to neutralize positive charges accumulated in the sample during the previous measurement. The adequate negative bias is determined and the equilibrium state of negative charging is discussed. The efficacy of the method is demonstrated by the measured electron yields in the cases with and without charge neutralization and by comparison with existing electron yield data of polyimide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Principles and biophysical applications of single particle super-localization and rotational tracking

While conventional Single Particle Tracking (SPT) techniques acquire 2D or 3D trajectories of particle probes, we have developed Single Particle Orientation and Rotational Tracking (SPORT) techniques to extract orientation and rotational information. Combined with DIC microscopy, the SPORT technique has been applied in biophysical studies, including membrane diffusion and intracellular transport. The rotational dynamics of nanoparticle vectors on live cell membranes was recorded and its influence on the fate of these nanoparticle vectors was elucidated. The rotational motions of gold nanorods with various surface modifiers were tracked continuously at a temporal resolution of 5 ms under a DIC microscope. We found that the rotational behaviors of gold nanorod vectors are strongly related to their surface charge, specific surface functional groups, and the availability of receptors on cell membranes. The study of rotational Brownian motion of nanoparticles on cell membranes will lead to a better understanding of the mechanisms of drug delivery and provide guidance in designing surface modification strategies for drug delivery vectors under various circumstances. To characterize the rotation mode of surface functionalized gold nanorods on cell membranes, the SPORT technique is combined with the correlation analysis of the bright and dark DIC intensities. The unique capabilities of visualizing and understanding rotational motions of functionalized nanoparticles on live cell membranes allow us to correlate rotational and translational dynamics in unprecedented detail and provide new insights for complex membrane processes, including electrostatic interactions, ligand-receptor binding, and lateral (confined and hopping) diffusion of membrane receptors. Surface-functionalized nanoparticles interact with the membrane in fundamentally different ways and exhibit distinct rotational modes. The early events of particle-membrane approach and attachment are directly visualized for the first time. The rotational dynamics of cargos in both active directional transport and pausing stages of axonal transport was also visualized using high-speed SPORT with a temporal resolution of 2 ms. Both long and short pauses are imaged, and the correlations between the pause duration, the rotational behaviour of the cargo at the pause, and the moving direction after the pause are established. Furthermore, the rotational dynamics leading to switching tracks are visualized in detail. These first-time observations of cargo's rotational dynamics provide new insights on how kinesin and dynein motors take the cargo through the alternating stages of active directional transport and pause. To improve the localization precision of the SPT technique with DIC microscopy, a precise three-dimensional (3D) localization method of spherical gold nanoparticle probes using model-based correlation coefficient mapping was introduced. To accomplish this, a stack of sample images at different z-positions are acquired, and a 3D intensity profile of the probe serving as the model is used to map out the positions of nanoparticles in the sample. By using this model-based correlation imaging method, precise localization can be achieved in imaging techniques with complicated point spread functions (PSF) such as differential interference contrast (DIC) microscopy. The 3D superlocalization method was applied to tracking gold nanospheres during live endocytosis events. Finally, a novel dual-modality imaging technique has been developed to super-localize a single gold nanorod while providing its orientation and rotational information. The super-localization of the gold nanorod can be accomplished by curve fitting the modified bright-field images generated by one of the two beams laterally shifted by the first Nomarski prism in a DIC microscope. The orientation and rotational information is derived from the DIC images of gold nanorods. The new imaging setup has been applied to study the steric hindrance induced by relatively large cargos in the microtubule gliding assay and to track nanocargos in the crowded cellular environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗