Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Aerosol Sampling Experiment on the International Space Station

The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

Aerosol↗

The GSFC Mark-2 three band hand-held radiometer

A self-contained, portable, hand-radiometer designed for field usage was constructed and tested. The device, consisting of a hand-held probe containing three sensors and a strap supported electronic module, weighs 4 1/2 kilograms. It is powered by flashlight and transistor radio batteries, utilizes two silicon and one lead sulfide detectors, has three liquid crystal displays, sample and hold radiometric sampling, and its spectral configuration corresponds to LANDSAT-D's thematic mapper bands. The device was designed to support thematic mapper ground-truth data collection efforts and to facilitate 'in situ' ground-based remote sensing studies of natural materials. Prototype instruments were extensively tested under laboratory and field conditions with excellent results.

Tucker, C. J.↗

High-temperature superconducting superconductor/normal metal/superconducting devices

We describe the fabrication and characterization of superconductor/normal metal/superconductor (SNS) devices made with the high-temperature superconductor (HTS) YBa2Cu3O(7-x). Structures of YBa2Cu3O(7-x)/Au/Nb on c-axis-oriented YBa2Cu3O(7-x) were made in both sandwich and edge geometries in order to sample the HTS material both along and perpendicular to the conducting a-b planes. These devices display fairly ideal Josephson properties at 4.2 K. In addition, devices consisting of YBa2Cu3O(7-x)/YBa2Cu3O(y)/YBa2Cu3O(7-x), with a 'normal metal' layer of reduced transition temperature YBa2Cu3O(7-x) were fabricated and show a great deal of promise for applications near 77 K. Current-voltage characteristics like those of the Resistively-Shunted Junction model are observed, with strong response to 10 GHz radiation above 60 K.

Foote, M. C.↗

Multifrequency Ultra-High Resolution Miniature Scanning Microscope Using Microchannel And Solid-State Sensor Technologies And Method For Scanning Samples

A miniature, ultra-high resolution, and color scanning microscope using microchannel and solid-state technology that does not require focus adjustment. One embodiment includes a source of collimated radiant energy for illuminating a sample, a plurality of narrow angle filters comprising a microchannel structure to permit the passage of only unscattered radiant energy through the microchannels with some portion of the radiant energy entering the microchannels from the sample, a solid-state sensor array attached to the microchannel structure, the microchannels being aligned with an element of the solid-state sensor array, that portion of the radiant energy entering the microchannels parallel to the microchannel walls travels to the sensor element generating an electrical signal from which an image is reconstructed by an external device, and a moving element for movement of the microchannel structure relative to the sample. Discloses a method for scanning samples whereby the sensor array elements trace parallel paths that are arbitrarily close to the parallel paths traced by other elements of the array.

Wang, Yu↗

Rock sampling

An apparatus for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The device includes grinding means for cutting grooves in the rock surface and to provide a grouping of thin, shallow, parallel ridges and cutter means to reduce these ridges to a powder specimen. Collection means is provided for the powder. The invention relates to rock grinding and particularly to the sampling of rock specimens with good size control.

Blum, P.↗

Optical multiple sample vacuum integrating sphere

An integrating sphere comprised of a uniform difusely reflecting spherical cavity, having mutually transverse input and output ports, and a linear sample transport mechanism is described. The sample transport mechanism is secured so that the multiple samples can be brought into registration with the input port, one at a time, without having to open or disassemble the apparatus when a change of sample is desired. A vacuum tight seal is provided between the cavity and the transport mechanism. This maintains the integrity of a vacuum generated with the sphere when attached to the source of optical energy. The device is utilized to test emissive characteristics such as the relative fluorescence quantum efficiency of a dye sample placed in the path of a monochromatic optical energy source coupled to the input port while having a light detector coupled to the output port.

Butner, C. L.↗

Microbiological testing of Skylab foods.

Review of some of the unique food microbiology problems and problem-generating circumstances the Skylab manned space flight program involves. The situations these problems arise from include: extended storage times, variations in storage temperatures, no opportunity to resupply or change foods after launch of the Skylab Workshop, first use of frozen foods in space, first use of a food-warming device in weightlessness, relatively small size of production lots requiring statistically valid sampling plans, and use of food as an accurately controlled part in a set of sophisticated life science experiments. Consideration of all of these situations produced the need for definite microbiological tests and test limits. These tests are described along with the rationale for their selection. Reported test results show good compliance with the test limits.

Heidelbaugh, N. D.↗

Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗

Knowledge From Pictures (KFP)

The old maxim goes: 'A picture is worth a thousand words'. The objective of the research reported in this paper is to demonstrate this idea as it relates to the knowledge acquisition process and the automated development of an expert system's rule base. A prototype tool, the Knowledge From Pictures (KFP) tool, has been developed which configures an expert system's rule base by an automated analysis of and reasoning about a 'picture', i.e., a graphical representation of some target system to be supported by the diagnostic capabilities of the expert system under development. This rule base, when refined, could then be used by the expert system for target system monitoring and fault analysis in an operational setting. Most people, when faced with the problem of understanding the behavior of a complicated system, resort to the use of some picture or graphical representation of the system as an aid in thinking about it. This depiction provides a means of helping the individual to visualize the bahavior and dynamics of the system under study. An analysis of the picture augmented with the individual's background information, allows the problem solver to codify knowledge about the system. This knowledge can, in turn, be used to develop computer programs to automatically monitor the system's performance. The approach taken is this research was to mimic this knowledge acquisition paradigm. A prototype tool was developed which provides the user: (1) a mechanism for graphically representing sample system-configurations appropriate for the domain, and (2) a linguistic device for annotating the graphical representation with the behaviors and mutual influences of the components depicted in the graphic. The KFP tool, reasoning from the graphical depiction along with user-supplied annotations of component behaviors and inter-component influences, generates a rule base that could be used in automating the fault detection, isolation, and repair of the system.

Truszkowski, Walt↗

Resonant Tunneling Analog-To-Digital Converter

As sampling rates continue to increase, current analog-to-digital converter (ADC) device technologies will soon reach a practical resolution limit. This limit will most profoundly effect satellite and military systems used, for example, for electronic countermeasures, electronic and signal intelligence, and phased array radar. New device and circuit concepts will be essential for continued progress. We describe a novel, folded architecture ADC which could enable a technological discontinuity in ADC performance. The converter technology is based on the integration of multiple resonant tunneling diodes (RTD) and hetero-junction transistors on an indium phosphide substrate. The RTD consists of a layered semiconductor hetero-structure AlAs/InGaAs/AlAs(2/4/2 nm) clad on either side by heavily doped InGaAs contact layers. Compact quantizers based around the RTD offer a reduction in the number of components and a reduction in the input capacitance Because the component count and capacitance scale with the number of bits N, rather than by 2 (exp n) as in the flash ADC, speed can be significantly increased, A 4-bit 2-GSps quantizer circuit is under development to evaluate the performance potential. Circuit designs for ADC conversion with a resolution of 6-bits at 25GSps may be enabled by the resonant tunneling approach.

Broekaert, T. P. E.↗

Algorithmic Enhancements for the VULCAN Navier-Stokes Solver

Work performed over the last three years has resulted in the addition of several new algorithms to the VULCAN code, NASA's standard for Navier-Stokes calculations in high-speed aeropropulsion devices. This final report describes the new techniques in brief and presents sample results from their use.

Edwards, Jack R.↗

Algorithmic Enhancements for the VULCAN Navier-Stokes Solver

Work performed over the last three years has resulted in the addition of several new algorithms to the VULCAN code, NASA's standard for Navier-Stokes calculations in high-speed aeropropulsion devices. This final report describes the new techniques in brief and presents sample results from their use.

Edwards, Jack R.↗

New Eddy Current Probe for Thickness Gauging of Conductive Materials

The accurate measure of material thickness is important for many non-destructive evaluation applications. Factors such as corrosion damage can jeopardize structural integrity through material thinning and process control considerations often mandate strict limits on material dimensions. Access to the material under test can be limited to a single side and large areas may need to be examined in a small time period. In an effort to enhance the effectiveness of material thickness measurements a flux focusing eddy current probe has been developed at NASA Langley Research Center. The probe provides an accurate measure of the thickness of conducting materials from a single sided measurement. It is straight forward to use and can be easily automated for production line testing. The probe also requires only minimal instrumentation and power so that extremely portable units can be manufactured at a low cost. This new eddy current probe has been used to accurately measure the thickness of aluminum alloy plates with a resolution of greater than 0.001 in. (25 microns). Simulated corrosion damage has also been detected on both single layer and multi-layer samples. The present work will explain the output voltage dependence of the device as a function of material thickness and present experimental results for thickness gauging and corrosion detection.

Wincheski, Buzz↗

Evaluation of Mobile Phone Interference With Aircraft GPS Navigation Systems

This report compiles and analyzes tests that were conducted to measure cell phone spurious emissions in the Global Positioning System (GPS) radio frequency band that could affect the navigation system of an aircraft. The cell phone in question had, as reported to the FAA (Federal Aviation Administration), caused interference to several GPS receivers on-board a small single engine aircraft despite being compliant with data filed at the time with the FCC by the manufacturer. NASA (National Aeronautics and Space Administration) and industry tests show that while there is an emission in the 1575 MHz GPS band due to a specific combination of amplifier output impedance and load impedance that induces instability in the power amplifier, these spurious emissions (i.e., not the intentional transmit signal) are similar to those measured on non-intentionally transmitting devices such as, for example, laptop computers. Additional testing on a wide sample of different commercial cell phones did not result in any emission in the 1575 MHz GPS Band above the noise floor of the measurement receiver.

Pace, Scott↗

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗

NASA Tech Briefs, January 2014

Topics include: Multi-Source Autonomous Response for Targeting and Monitoring of Volcanic Activity; Software Suite to Support In-Flight Characterization of Remote Sensing Systems; Visual Image Sensor Organ Replacement; Ultra-Wideband, Dual-Polarized, Beam-Steering P-Band Array Antenna; Centering a DDR Strobe in the Middle of a Data Packet; Using a Commercial Ethernet PHY Device in a Radiation Environment; Submerged AUV Charging Station; Habitat Demonstration Unit (HDU) Vertical Cylinder Habitat; Origami-Inspired Folding of Thick, Rigid Panels; A Novel Protocol for Decoating and Permeabilizing Bacterial Spores for Epifluorescent Microscopy; Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples; Enabling Microliquid Chromatography by Microbead Packing of Microchannels; On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF; Deployable Fresnel Rings; Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics; Spacecraft Trajectory Analysis and Mission Planning Simulation (STAMPS) Software; Cross Support Transfer Service (CSTS) Framework Library; Arbitrary Shape Deformation in CFD Design; Range Safety Flight Elevation Limit Calculation Software; Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors; Calculation of Operations Efficiency Factors for Mars Surface Missions; GPU Lossless Hyperspectral Data Compression System; Robust, Optimal Subsonic Airfoil Shapes; Protograph-Based Raptor-Like Codes; Fuzzy Neuron: Method and Hardware Realization; Kalman Filter Input Processor for Boresight Calibration; Organizing Compression of Hyperspectral Imagery to Allow Efficient Parallel Decompression; and Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption.

Source record↗

Modeling of particle flow due to ultrasonic drilling

In-situ sampling and analysis is one of the major tasks in future NASA exploration missions. It is essential that the samples on other planets including Mars are free of contaminations from the earth. Recently, a novel drilling technology that is actuated by a piezoelectric drive mechanism was developed at it is called Ultrasonic/Sonic Driller/Corer.

ultrasonic/sonic↗