Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPACE LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Interleaved Carbon Minibeams: An Experimental Radiosurgery Method With Clinical Potential

Purpose: To evaluate the efficacy of 'interleaved carbon minibeams' for ablating a 6.5-mm target in a rabbit brain with little damage to the surrounding brain. The method is based on the well-established tissue-sparing effect of arrays of thin planes of radiation. Methods and Materials: Broad carbon beams from the National Aeronautics and Space Agency Space Radiation Facility at Brookhaven National Laboratory were segmented into arrays of parallel, horizontal, 0.3-mm-thick planar beams (minibeams). The minibeams' gradual broadening in tissues resulted in 0.525-mm beam thickness at the target's proximal side in the spread-out Bragg peak. Interleaving was therefore implemented by choosing a 1.05 mm beam spacing on-center. The anesthetized rabbit, positioned vertically on a stage capable of rotating about a vertical axis, was exposed to arrays from four 90 Degree-Sign angles, with the stage moving up by 0.525 mm in between. This produced a solid radiation field at the target while exposing the nontargeted tissues to single minibeam arrays. The target 'physical' absorbed dose was 40.2 Gy. Results: The rabbit behaved normally during the 6-month observation period. Contrast magnetic resonance imaging and hematoxylin and eosin histology at 6 months showed substantial focal target damage with little damage to the surrounding brain. Conclusion: We plan to evaluate the method's therapeutic efficacy by comparing it with broad-beam carbon therapy in animal models. The method's merits would combine those of carbon therapy (i.e., tight target dose because of the carbon's Bragg-peak, sharp dose falloff, and high relative biological effectiveness at the target), together with the method's low impact on the nontargeted tissues. The method's smaller impact on the nontargeted brain might allow carbon therapy at higher target doses and/or lower normal tissue impact, thus leading to a more effective treatment of radioresistant tumors. It should also make the method more amenable to administration in either a single dose fraction or in a small number of fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FAR-INFRARED SPECTROSCOPY OF CATIONIC POLYCYCLIC AROMATIC HYDROCARBONS: ZERO KINETIC ENERGY PHOTOELECTRON SPECTROSCOPY OF PENTACENE VAPORIZED FROM LASER DESORPTION

The distinctive set of infrared (IR) emission bands at 3.3, 6.2, 7.7, 8.6, and 11.3 {mu}m are ubiquitously seen in a wide variety of astrophysical environments. They are generally attributed to polycyclic aromatic hydrocarbon (PAH) molecules. However, not a single PAH species has yet been identified in space, as the mid-IR vibrational bands are mostly representative of functional groups and thus do not allow one to fingerprint individual PAH molecules. In contrast, the far-IR (FIR) bands are sensitive to the skeletal characteristics of a molecule, hence they are important for chemical identification of unknown species. With an aim to offer laboratory astrophysical data for the Herschel Space Observatory, Stratospheric Observatory for Infrared Astronomy, and similar future space missions, in this work we report neutral and cation FIR spectroscopy of pentacene (C{sub 22}H{sub 14}), a five-ring PAH molecule. We report three IR active modes of cationic pentacene at 53.3, 84.8, and 266 {mu}m that may be detectable by space missions such as the SAFARI instrument on board SPICA. In the experiment, pentacene is vaporized from a laser desorption source and cooled by a supersonic argon beam. We have obtained results from two-color resonantly enhanced multiphoton ionization and two-color zero kinetic energy photoelectron (ZEKE) spectroscopy. Several skeletal vibrational modes of the first electronically excited state of the neutral species and those of the cation are assigned, with the aid of ab initio and density functional calculations. Although ZEKE is governed by the Franck-Condon principle different from direct IR absorption or emission, vibronic coupling in the long ribbon-like molecule results in the observation of a few IR active modes. Within the experimental resolution of {approx}7 cm{sup -1}, the frequency values from our calculation agree with the experiment for the cation, but differ for the electronically excited intermediate state. Consequently, modeling of the intensity distribution is difficult and may require explicit inclusion of vibronic interactions.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring the connection between compact object mergers and fast X-ray transients

Context. The connection between compact object mergers and some extragalactic fast X-ray transients (FXRTs) has long been hypothesised but never ultimately established. Aims. In this work, we investigate two FXRTs, the LEIA X-ray Transient LXT 240402A and the Einstein Probe EP 250207b, whose precise positions lie close to nearby (z ≲ 0.1) quiescent galaxies with a negligible probability of chance coincidence, identifying them as particularly promising cases of merger-driven explosions in the local Universe. Methods. We used Chandra to derive accurate localisations for both events and secure otherwise ambiguous associations with their optical counterparts. Deep optical and near-infrared observations with VLT, GTC, and LBT were performed to characterise the surrounding environment and search for kilonova emission, the hallmark of neutron star mergers. Complementary early-time X-ray monitoring with Swift and Einstein Probe was used to constrain the non-thermal afterglow. Results. We find that both FXRTs remain compatible with a compact binary merger progenitor, which produced low-mass ejecta and kilonova emission subdominant to the afterglow. However, alternative explanations such as a distant (z ≳ 1) core-collapse supernova cannot be conclusively ruled out.

79 ASTRONOMY AND ASTROPHYSICS↗

Confined Space Evaluation Student Manual, #19613

Many workplaces contain spaces that are considered to be “confined” because their configuration hinders the activities of employees who must enter into, work in, and exit from them. In general, the permit-required confined spaces (PRCSs) Occupational Safety and Health Administration (OSHA) standard requires that Los Alamos National Laboratory (LANL) evaluate the workplace to determine if any spaces are PRCSs. The standard specifies strict procedures for the evaluation and atmospheric testing of a space before and during an entry by workers. The OSHA PRCS standard provides for alternative (less stringent than full-permit) entry procedures in cases where the only hazard in a space is atmospheric and the hazard can be controlled by forced air. At LANL, all confined spaces or potential confined spaces on LANL-owned or -operated property must be identified and evaluated by a confined space evaluator accompanied by a knowledgeable person. This course provides the information needed by confined space evaluators to make judgements about whether a space is a confined space, and if so, whether the space will require a permit for entry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Perils of Space Weather

The Sun’s continuous bombardment of the Earth with high-energy electrons, protons, and other nuclei results in space weather that can wreak havoc on the nation’s satellites, aircraft, communications networks, navigation systems, and the electric power grid. Because of the potential for space weather to so critically impact national security, Los Alamos National Laboratory has been studying it for decades, designing and building space-based sensors to detect emissions from potential nuclear events here on Earth and to study natural and man-made radiation in space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compendium of chameleon constraints

The chameleon model is a scalar field theory with a screening mechanism that explains how a cosmologically relevant light scalar can avoid the constraints of intra-solar-system searches for fifth-forces. The chameleon is a popular dark energy candidate and also arises in f ( R ) theories of gravity. Whilst the chameleon is designed to avoid historical searches for fifth-forces it is not unobservable and much effort has gone into identifying the best observables and experiments to detect it. These results are not always presented for the same models or in the same language, a particular problem when comparing astrophysical and laboratory searches making it difficult to understand what regions of parameter space remain. Here we present combined constraints on the chameleon model from astrophysical and laboratory searches for the first time and identify the remaining windows of parameter space. We discuss the implications for cosmological chameleon searches and future small-scale probes.

79 ASTRONOMY AND ASTROPHYSICS↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Alfvén wave collisions, the fundamental building block of plasma turbulence. IV. Laboratory experiment

Turbulence is a phenomenon found throughout space and astrophysical plasmas. It plays an important role in solar coronal heating, acceleration of the solar wind, and heating of the interstellar medium. Turbulence in these regimes is dominated by Alfvén waves. Most turbulence theories have been established using ideal plasma models, such as incompressible MHD. However, there has been no experimental evidence to support the use of such models for weakly to moderately collisional plasmas which are relevant to various space and astrophysical plasma environments. We present the first experiment to measure the nonlinear interaction between two counterpropagating Alfvén waves, which is the building block for astrophysical turbulence theories. We present here four distinct tests that demonstrate conclusively that we have indeed measured the daughter Alfvén wave generated nonlinearly by a collision between counterpropagating Alfvén waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratories for the 21st Century Best Practices: Energy Recovery in Laboratory Facilities

Laboratories typically require 100% outside air for ventilation at higher rates than other commercial buildings. Minimum ventilation is typically provided at air change per hour (ACH) rates in accordance with codes and adopted design standards including Occupational Safety and Health Administration (OSHA) Standard 1910.1450 (4 to 12 ACH – non-mandatory) or the 2011 American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Applications Handbook, Chapter 16 – Laboratories (6 to 12 ACH). While OSHA states this minimum ventilation rate “should not be relied on for protection from toxic substances released into the laboratory” it specifically indicates that it is intended to “provide a source of air for breathing and for input to local ventilation devices (e.g., chemical fume hoods or exhausted bio-safety cabinets), to ensure that laboratory air is continually replaced preventing the increase of air concentrations of toxic substances during the working day, direct air flow into the laboratory from non-laboratory areas and out to the exterior of the building.” The heating and cooling energy needed to condition and move this outside air can be 5 to 10 times greater than the amount of energy used in most office buildings. In addition, when the required ventilation rate exceeds the airflow needed to meet the cooling load in low-load laboratories, additional heating energy may be expended to reheat dehumidified supply air from the supply air condition to prevent over cooling. In addition to these low-load laboratories, reheat may also be required in adjacent spaces such as corridors that pro-vide makeup air to replace air being pulled into negative-pressure laboratories.

Laboratories, Best Practices, Energy, Facilities↗

Predicting fault slip via transfer learning

Abstract Data-driven machine-learning for predicting instantaneous and future fault-slip in laboratory experiments has recently progressed markedly, primarily due to large training data sets. In Earth however, earthquake interevent times range from 10’s-100’s of years and geophysical data typically exist for only a portion of an earthquake cycle. Sparse data presents a serious challenge to training machine learning models for predicting fault slip in Earth. Here we describe a transfer learning approach using numerical simulations to train a convolutional encoder-decoder that predicts fault-slip behavior in laboratory experiments. The model learns a mapping between acoustic emission and fault friction histories from numerical simulations, and generalizes to produce accurate predictions of laboratory fault friction. Notably, the predictions improve by further training the model latent space using only a portion of data from a single laboratory earthquake-cycle. The transfer learning results elucidate the potential of using models trained on numerical simulations and fine-tuned with small geophysical data sets for potential applications to faults in Earth.

58 GEOSCIENCES↗

The role of Aspo Hard Rock laboratory for the Swedish nuclear fuel and waste management's research, developing and demonstration programme for a final repository of spent nuclear fuel - 15378

The Aspo Hard Rock Laboratory (HRL), located in the Simpevarp area in the municipality of Oskarshamn in Sweden, Figure 1, constitutes an important part of the Swedish Nuclear Fuel and Waste Management (SKB) work with design and construction of a deep geological repository for final disposal of spent nuclear fuel. One of the fundamental reasons behind SKB's decision to construct an underground laboratory was to create an opportunity for research, development and demonstration in a realistic and undisturbed rock environment down to repository depth. Most of the research has concerned with processes of importance for the long-term safety of a future final repository and the capability to model the processes taking place at repository depth. Demonstration addresses the performance of the engineered barriers and practical means of constructing a repository and emplacing the canisters containing spent fuel. SKB will in the coming years more focus on using the Aspo HRL for demonstrating technology for and function of important parts of the repository system before constructing and operate the spent nuclear fuel repository in Forsmark. Aspo HRL includes both a research village with office space for 100 persons and different laboratories, e.g. Chemistry and Material Science Laboratory and Bentonite Laboratory, and an underground research laboratory to a depth of 460 m. The Aspo HRL is also open for other organisations to be used for their own projects and experiments not only related to nuclear waste management research. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transport of Parallel Momentum by Toroidal Ion Temperature Gradient Instability near Marginality

The turbulent angular momentum flux carried by ions resonant with toroidal ion temperature gradient(ITG) instability is calculated via quasilinear calculation using the phase-space conserving gyrokinetic equation in the laboratory frame. The results near ITG marginality indicate that the inward turbulent equipartition (TEP) momentum pinch [Hahm T.S. et al 2007 Phys. Plasmas 14 072302] remains as the most robust part of pinch. In addition, ion temperature gradient driven momentum flux is inward for typical parameters, while density gradient driven momentum flux is outward as in the previous kinetic result in slab geometry [Diamond P.H. et al 2008 Phys. Plasmas 15 012303].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cation ordering and physicochemical characterization of the quaternary diamond-like semiconductor Ag[subscript 2]CdGeS[subscript 4]

The quaternary diamond-like semiconductor, Ag2CdGeS4, was synthesized via high-temperature solid-state synthesis as well as structurally and physicochemically characterized. Single crystal X-ray diffraction provided a model for Ag2CdGeS4 in the orthorhombic, noncentrosymmetric space group Pna21 with a=13.7415(8) {angstrom}, b=8.0367(5) {angstrom} and c=6.5907(4) {angstrom}, in contrast to a previously published model in Pmn21 from the Rietveld analysis of laboratory X-ray powder diffraction data. The Pna21 space group is supported by the Rietveld analysis of synchrotron X-ray powder diffraction data. Differential thermal analysis suggests that Ag2CdGeS4 exists in two polymorphs. Optical diffuse reflectance UV/vis/NIR spectroscopy indicates that the orange compound is a semiconductor with a band gap of 2.32 eV. Optical microscopy, scanning electron microscopy, energy dispersive spectroscopy and inductively coupled plasma optical emission spectroscopy were used to further characterize the material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulations and experiments of intense ion beam current density compression in space and time

The Heavy Ion Fusion Science Virtual National Laboratory has achieved 60-fold longitudinal pulse compression of ion beams on the Neutralized Drift Compression Experiment (NDCX) [P. K. Roy et al., Phys. Rev. Lett. 95, 234801 (2005)]. To focus a space-charge-dominated charge bunch to sufficiently high intensities for ion-beam-heated warm dense matter and inertial fusion energy studies, simultaneous transverse and longitudinal compression to a coincident focal plane is required. Optimizing the compression under the appropriate constraints can deliver higher intensity per unit length of accelerator to the target, thereby facilitating the creation of more compact and cost-effective ion beam drivers. The experiments utilized a drift region filled with high-density plasma in order to neutralize the space charge and current of an {approx}300 keV K{sup +} beam and have separately achieved transverse and longitudinal focusing to a radius <2 mm and pulse duration <5 ns, respectively. Simulation predictions and recent experiments demonstrate that a strong solenoid (B{sub z}<100 kG) placed near the end of the drift region can transversely focus the beam to the longitudinal focal plane. This paper reports on simulation predictions and experimental progress toward realizing simultaneous transverse and longitudinal charge bunch focusing. The proposed NDCX-II facility would capitalize on the insights gained from NDCX simulations and measurements in order to provide a higher-energy (>2 MeV) ion beam user-facility for warm dense matter and inertial fusion energy-relevant target physics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulations and experiments of intense ion beam compression in space and time.

The Heavy Ion Fusion Science Virtual National Laboratory has achieved 60-fold longitudinal pulse compression of ion beams on the Neutralized Drift Compression Experiment (NDCX) [P. K. Roy et al., Phys. Rev. Lett. 95, 234801 (2005)]. To focus a space-charge-dominated charge bunch to sufficiently high intensities for ion-beam-heated warm dense matter and inertial fusion energy studies, simultaneous transverse and longitudinal compression to a coincident focal plane is required. Optimizing the compression under the appropriate constraints can deliver higher intensity per unit length of accelerator to the target, thereby facilitating the creation of more compact and cost-effective ion beam drivers. The experiments utilized a drift region filled with high-density plasma in order to neutralize the space charge and current of an {approx}300 keV K{sup +} beam and have separately achieved transverse and longitudinal focusing to a radius <2 mm and pulse duration <5 ns, respectively. Simulation predictions and recent experiments demonstrate that a strong solenoid (B{sub Z} < 100 kG) placed near the end of the drift region can transversely focus the beam to the longitudinal focal plane. This paper reports on simulation predictions and experimental progress toward realizing simultaneous transverse and longitudinal charge bunch focusing. The proposed NDCX-II facility would capitalize on the insights gained from NDCX simulations and measurements in order to provide a higher-energy (>2 MeV) ion beam user-facility for warm dense matter and inertial fusion energy-relevant target physics experiments.

43 PARTICLE ACCELERATORS↗

Space and Defense Power Systems Maintenance Plan

Los Alamos National Laboratory (LANL) has more than forty years of experience in developing, characterizing, testing, and manufacturing plutonium-238 ( 238 Pu) heat sources. The LANL heat source program has made significant contributions to the United States space, defense, and national security missions, as well as the nuclear-powered artificial heart program. Currently, the Office of Space and Defense Power Systems (SDPS), located in the Nuclear Energy Group (NE-75), funds LANL for the infrastructure and processes used to store, recover, manufacture, and test 238 PuO 2 heat sources. LANL is an approved supplier of the General Purpose Heat Source (GPHS), which is a 238 PuO 2 Fueled Clad designed to provide 62.5 thermal watts. The Light Weight Radioisotope Heater Unit (LWRHU) is another 238 PuO 2 fueled heat source manufactured at LANL. The LWRHU is designed to provide one thermal watt in various locations on a spacecraft. LANL also supports the manufacture of other heat sources for various customers.

07 ISOTOPE AND RADIATION SOURCES↗

Cosmological constraints on exotic injection of electromagnetic energy

We compute cosmic microwave background (CMB) anisotropy constraints on exotic forms of energy injection in electromagnetic (e.m.) channels over a large range of timescales. We show that these constraints are very powerful around or just after recombination, although CMB keeps some sensitivity e.g. to decaying species with lifetimes as long as 10{sup 25} s. These bounds are complementary to CMB spectral distortions and primordial nucleosynthesis ones, which dominate at earlier timescales, as we also review here. For the first time, we describe the effects of the e.m. energy injection on the CMB power spectra as a function of the injection epoch , using the lifetime of a decaying particle as proxy. We also identify a suitable on-the-spot approximation, that can be used to derive accurate constraints, and describe its differences with the most up-to-date treatment. Our results are of interest not only for early universe relics constituting (a fraction of) the dark matter, but also for other exotic injection of e.m. radiation. For illustration, we apply our formalism to: i) Primordial black holes of mass 10{sup 13.5} g ∼< M ∼< 10{sup 16.8} g, showing that the constraints are comparable to the ones obtained from gamma-ray background studies and even dominate below ∼ 10{sup 14} g. ii) To a peculiar mass-mixing range in the sterile neutrino parameter space, complementary to other astrophysical and laboratory probes. iii) Finally, we provide a first estimate of the room for improvement left for forthcoming 21 cm experiments, comparing it with the reach of proposed CMB spectral distortion (PiXiE) and CMB angular power spectrum (CORE) missions. We show that the best and most realistic opportunity to look for this signal (or to improve over current constraints) in the 21 cm probe is to focus on the Cosmic Dawn epoch, 15 ∼< z ∼< 30, where the qualitatively unambiguous signature of a spectrum in emission can be expected for models that evade all current constraints.

79 ASTRONOMY AND ASTROPHYSICS↗