Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Incoherent scatter observations of an artificially modified ionosphere

The 'experiment of opportunity' to test incoherent scatter radar techniques for the diagnostic study of a chemically induced modification of the ionosphere occasioned by the launch of the HEAO-C satellite is described. The optimal utilization of a steerable incoherent scatter radar for a short duration event is examined. The choice of keeping the antenna fixed to obtain good control data and excellent time resolution along a given direction versus scanning the antenna to obtain mixed spatial and temporal morphologies is discussed. Results for fixed position measurements, elevation scans, ion-drift, and total electron content are presented. The first unambiguous observations of a gas expansion 'snowplow effect' is reported along with the derivation of local and height-integrated plasma recombination rates and the full spatial, temporal, and dynamical morphologies of a large-scale ionospheric hole.

Wand, R. H.↗

Effects of combining vertical and horizontal information into a primary flight display

A ground-based aircraft simulation study was conducted to determine the effects of combining vertical and horizontal flight information into a single display. Two display configurations were used in this study. The first configuration consisted of a Primary Flight Display (PFD) format and a Horizontal Situation Display (HSD) with the PFD displayed conventionally above the HSD. For the second display configuration, the HSD format was combined with the PFD format. Four subjects participated in this study. Data were collected on performance parameters, pilot-control inputs, auditory evoked response parameters (AEP), oculometer measurements (eye-scan), and heart rate. Subjective pilot opinion was gathered through questionnaire data and scorings for both the Subjective Workload Assessment Technique (SWAT) and the NASA Task Load Index (NASA-TLX). The results of this study showed that, from a performance and subjective standpoint, the combined configuration was better than the separate configuration. Additionally, both the eye-transition and eye-dwell times for the separate HSD were notably higher than expected, with a 46% increase in available visual time when going from double to single display configuration.

Abbott, Terence S.↗

Ruling Blazed, Aberration-Corrected Diffraction Gratings

Proposed optoelectromechanical apparatus that functions partly as ruling engine and partly as pantograph rules blazed, aberration-corrected diffraction gratings. Makes possible to combine precision of aberration-corrected, holographically produced grating with diffraction efficiency of blazed grating by using holographically produced grating as model or master pattern that controls ruling engine making blazed grating. Surface of model holographic grating scanned by sensing head mounted on pantographic arm. Ruling stylus mounted on other end of pantographic arm with tip in grating blank.

Leviton, Douglas B.↗

A combined Earth scanner and momentum wheel for attitude determination and control of small spacecraft

In order to satisfy the stringent cost and power requirements of small satellites, an advanced SCANWHEEL was designed, built, and qualified by ITHACO, Inc. The T-SCANWHEEL is a modular momentum/reaction wheel with an integral conical Earth scanner. The momentum wheel provides momentum bias and control torques about the pitch axis of a spacecraft. An angled scan mirror coupled to the rotating shaft of the momentum wheel provides a conical scan of the field-of-view of an infrared sensor to provide pitch-and-roll attitude information. By using the same motor and bearings for the momentum wheel and Earth scanner, the overall power consumption is reduced and the system reliability is enhanced. The evolution of the T-SCANWHEEL is presented, including design ground rules, tradeoff analyses, and performance results.

Bialke, Bill↗

The NASA/NSO spectromagnetograph

The Kitt Peak Vacuum Telescope's spectromagnetograph features real-time digital analysis of long-slit spectra formed on a 2D CCD detector, and is located at an exit port of a Littrow spectrograph. Commercial video processing boards are used to digitize the spectral images at video rates and to separate, accumulate, and buffer the spectra in the two polarization states. A processor removes fixed-pattern bias and gain from the spectra in cadence with spatial scanning of the image across the entrance slit; a data-control computer conducts position and width analysis of the line profiles and records line-of-sight magnetic field, Doppler shift, and other computed parameters, as demonstrated by the early observations presented.

Jones, Harrison P.↗

Monitoring Disasters by Use of Instrumented Robotic Aircraft

Efforts are under way to develop data-acquisition, data-processing, and data-communication systems for monitoring disasters over large geographic areas by use of uninhabited aerial systems (UAS) robotic aircraft that are typically piloted by remote control. As integral parts of advanced, comprehensive disaster- management programs, these systems would provide (1) real-time data that would be used to coordinate responses to current disasters and (2) recorded data that would be used to model disasters for the purpose of mitigating the effects of future disasters and planning responses to them. The basic idea is to equip UAS with sensors (e.g., conventional video cameras and/or multispectral imaging instruments) and to fly them over disaster areas, where they could transmit data by radio to command centers. Transmission could occur along direct line-of-sight paths and/or along over-the-horizon paths by relay via spacecraft in orbit around the Earth. The initial focus is on demonstrating systems for monitoring wildfires; other disasters to which these developments are expected to be applicable include floods, hurricanes, tornadoes, earthquakes, volcanic eruptions, leaks of toxic chemicals, and military attacks. The figure depicts a typical system for monitoring a wildfire. In this case, instruments aboard a UAS would generate calibrated thermal-infrared digital image data of terrain affected by a wildfire. The data would be sent by radio via satellite to a data-archive server and image-processing computers. In the image-processing computers, the data would be rapidly geo-rectified for processing by one or more of a large variety of geographic-information- system (GIS) and/or image-analysis software packages. After processing by this software, the data would be both stored in the archive and distributed through standard Internet connections to a disaster-mitigation center, an investigator, and/or command center at the scene of the fire. Ground assets (in this case, firefighters and/or firefighting equipment) would also be monitored in real time by use of Global Positioning System (GPS) units and radio communication links between the assets and the UAS. In this scenario, the UAS would serve as a data-relay station in the sky, sending packets of information concerning the locations of assets to the image-processing computer, wherein this information would be incorporated into the geo-rectified images and maps. Hence, the images and maps would enable command-center personnel to monitor locations of assets in real time and in relation to locations affected by the disaster. Optionally, in case of a disaster that disrupted communications, the UAS could be used as an airborne communication relay station to partly restore communications to the affected area. A prototype of a system of this type was demonstrated in a project denoted the First Response Experiment (Project FiRE). In this project, a controlled outdoor fire was observed by use of a thermal multispectral scanning imager on a UAS that delivered image data to a ground station via a satellite uplink/ downlink telemetry system. At the ground station, the image data were geo-rectified in nearly real time for distribution via the Internet to firefighting managers. Project FiRE was deemed a success in demonstrating several advances essential to the eventual success of the continuing development effort.

Wegener, Steven S.↗

Improved Cloud Condensation Nucleus Spectrometer

An improved thermal-gradient cloud condensation nucleus spectrometer (CCNS) has been designed to provide several enhancements over prior thermal- gradient counters, including fast response and high-sensitivity detection covering a wide range of supersaturations. CCNSs are used in laboratory research on the relationships among aerosols, supersaturation of air, and the formation of clouds. The operational characteristics of prior counters are such that it takes long times to determine aerosol critical supersaturations. Hence, there is a need for a CCNS capable of rapid scanning through a wide range of supersaturations. The present improved CCNS satisfies this need. The improved thermal-gradient CCNS (see Figure 1) incorporates the following notable features: a) The main chamber is bounded on the top and bottom by parallel thick copper plates, which are joined by a thermally conductive vertical wall on one side and a thermally nonconductive wall on the opposite side. b) To establish a temperature gradient needed to establish a supersaturation gradient, water at two different regulated temperatures is pumped through tubes along the edges of the copper plates at the thermally-nonconductive-wall side. Figure 2 presents an example of temperature and supersaturation gradients for one combination of regulated temperatures at the thermally-nonconductive-wall edges of the copper plates. c) To enable measurement of the temperature gradient, ten thermocouples are cemented to the external surfaces of the copper plates (five on the top plate and five on the bottom plate), spaced at equal intervals along the width axis of the main chamber near the outlet end. d) Pieces of filter paper or cotton felt are cemented onto the interior surfaces of the copper plates and, prior to each experimental run, are saturated with water to establish a supersaturation field inside the main chamber. e) A flow of monodisperse aerosol and a dilution flow of humid air are introduced into the main chamber at the inlet end. The inlet assembly is designed to offer improved (relative to prior such assemblies) laminar-flow performance within the main chamber. Dry aerosols are subjected to activation and growth in the supersaturation field. f) After aerosol activation, at the outlet end of the main chamber, a polished stainless-steel probe is used to sample droplets into a laser particle counter. The probe features an improved design for efficient sampling. The counter has six channels with size bins in the range of 0.5- to 5.0-micron diameter. g) To enable efficient sampling, the probe is scanned along the width axis of the main chamber (thereby effecting scanning along the temperature gradient and thereby, further, effecting scanning along the supersaturation gradient) by means of a computer-controlled translation stage.

Leu, Ming-Taun↗

Multipurpose Hyperspectral Imaging System

A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral imaging with or without relative movement of the imaging system, and it can be used to scan a target of any size as long as the target can be imaged at the focal plane; for example, automated inspection of food items and identification of single-celled organisms. The spectral resolution of this system is greater than that of prior terrestrial multispectral imaging systems. Moreover, unlike prior high-spectral resolution airborne and spaceborne hyperspectral imaging systems, this system does not rely on relative movement of the target and the imaging system to sweep an imaging line across a scene. This compact system (see figure) consists of a front objective mounted at a translation stage with a motorized actuator, and a line-slit imaging spectrograph mounted within a rotary assembly with a rear adaptor to a charged-coupled-device (CCD) camera. Push-broom scanning is carried out by the motorized actuator which can be controlled either manually by an operator or automatically by a computer to drive the line-slit across an image at a focal plane of the front objective. To reduce the cost, the system has been designed to integrate as many as possible off-the-shelf components including the CCD camera and spectrograph. The system has achieved high spectral and spatial resolutions by using a high-quality CCD camera, spectrograph, and front objective lens. Fixtures for attachment of the system to a microscope (U.S. Patent 6,495,818 B1) make it possible to acquire multispectral images of single cells and other microscopic objects.

Mao, Chengye↗

The Cassini Live Update Process

The Cassini orbiter is an international science mission to the Saturnian system with 12 science instruments onboard. The Cassini spacecraft lacks a scan platform, which means the entire spacecraft must be rotated to control pointing of any one instrument's boresight. The resulting complex sequences of commands are built beginning many months before execution onboard. Late ephemeris updates from improved navigation data (i.e. after an orbital trim maneuver) often result in pointing commands in the sequence no longer being accurate enough to obtain the desired science observation. This paper will provide an overview of how Cassini uses live updates to address this potential loss of data, including the software developed for this process.

Vandermey, Nancy↗

Reconfigurable Transmission Line for a Series-Fed Ku-Band Phased Array Using a Single Feed

The paper presents a novel approach to realize a lowcost phased array using a simple feeding mechanism. Specifically, a single coplanar stripline (CPS) transmission line is used to feed the antenna array elements. By controlling the CPS's dielectric properties using a movable dielectric plunger, scanning is achieved. Due to its simplicity, single feed, and no phase shifters, this approach leads to a dramatic reduction in cost which does not scale for larger arrays.

Reconfigurable Transmission Lines↗

Effect of Thin-Film Adhesives on Mode II Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

A single sheet of nickel-titanium (NiTi) shape memory alloy (SMA) was introduced within an IM7/8552 polymer matrix composite (PMC) panel in conjunction with multiple thin film adhesives to promote the interfacial bond strength between the SMA and PMC. End notched flexure (ENF) testing was performed in accordance to ASTM D7905 method for evaluation of mode II interlaminar fracture toughness (GIIC) of unidirectional fiber-reinforced polymer matrix composites. Acoustic emissions (AE) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels were subjected to C-scan before testing, and examined using optical and scanning electron microscopy techniques after part failure. GIIC values for the control composite samples were found to be higher than those of samples with embedded SMA sheets. The presence of adhesives bonded to SMA sheets further diminished the GIIC values. AE values revealed poor bonding of the panels, with little to no signals during testing.

End Notched Flexure↗

The Effect of Thin Film Adhesives on Mode II Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

A single sheet of nickel-titanium (NiTi) shape memory alloy (SMA) was introduced within an IM7/8552 polymer matrix composite (PMC) panel in conjunction with multiple thin film adhesives to promote the interfacial bond strength between the SMA and PMC. End notched flexure (ENF) testing was performed in accordance to ASTM D7905 method for evaluation of mode II interlaminar fracture toughness (GIIC) of unidirectional fiber-reinforced polymer matrix composites. Acoustic emissions (AE) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels examined using scanning electron microscopy techniques after part failure. GIIC values for the control composite samples were found to be higher than those of samples with embedded SMA sheets. The presence of adhesives bonded to SMA sheets further diminished the GIIC values. AE values revealed poor bonding of the panels, with little to no signals during testing.

End Notched Flexure↗

Physics insights from a large-scale 2D UEDGE simulation database for detachment control in KSTAR

A large-scale database of two-dimensional UEDGE simulations has been developed to study detachment physics in KSTAR and to support surrogate models for control applications. Nearly 70 000 steady-state solutions were generated, systematically scanning upstream density, input power, plasma current, impurity fraction, and anomalous transport coefficients, with magnetic and electric drifts across the magnetic field included. The database identifies robust detachment indicators, with strike-point electron temperature at detachment onset consistently T e,target ~ 3-4 eV, largely insensitive to upstream conditions. Scaling relations reveal weaker impurity sensitivity than one-dimensional models and show that heat flux widths follow Eich’s scaling only for uniform, low D and χ. Distinctive in–out divertor asymmetries are observed in KSTAR, differing qualitatively from DIII-D. Complementary time-dependent simulations quantify plasma response to gas puffing, with delays of 5 - 15 ms at the outer strike point and ∼ 40 ms for the low-magnetic-field-side radiation front. These dynamics are well captured by first-order-plus-dead-time models and are consistent with experimentally observed detachment-control behavior in KSTAR (Gupta et al 2025 Plasma Phys. Control. Fusion (submitted)).

Physics - Plasma physics↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Imaging Supramolecular Morphogenesis with Confocal Laser Scanning Microscopy at Elevated Temperatures

The morphogenesis of supramolecular assemblies is a highly dynamic process that has only recently been recognized, and our understanding of this phenomenon will require imaging techniques capable of crossing scales. Shape transformations depend both on the complex energy landscapes of supramolecular systems and the kinetically controlled pathways that define their structures and functions. We report here the use of confocal laser scanning microscopy coupled with a custom-designed variable-temperature sample stage that enables in situ observation of such shape changes. The submicrometer resolution of this technique allows for real-time observation of the nanostructures in the native liquid environments in which they transform with thermal energy. We use this technique to study the temperature-dependent morphogenic behavior of peptide amphiphile nanofibers and photocatalytic chromophore amphiphile nanoribbons. Furthermore, the variable-temperature confocal microscopy technique demonstrated in this work can sample a large volume and provides real-time information on thermally induced morphological changes in the solution.

36 MATERIALS SCIENCE↗

Comparison of MODIS and VIIRS On-board Blackbody Performance

MODIS has 16 thermal emissive bands (TEBs), covering wavelengths from 3.7 to 14.4 microns. MODIS TEBs are calibrated on-orbit by a v-grooved blackbody (BB) on a scan-by-scan basis. The BB temperatures are measured by a set of 12 thennistors. As expected, the BB temperature uncertainty and stability have direct impact on the quality of TEB calibration and, therefore, the quality of the science products derived from TEB observations. Since launch, Terra and Aqua MODIS have successfully operated for more than 12 and 10 years, respectively. Their on-board BB performance has been satisfactory in meeting the TEB calibration requirements. The first VIIRS, launched on-board the Suomi NPP spacecraft on October 28, 2011, has successfully completed its initial Intensive Calibration and Validation (ICV) phase. VIIRS has 7 thermal emissive bands (TEBs), covering wavelengths from 3.7 to 12.4 microns. Designed with strong MODIS heritage, VIIRS uses a similar BB for its TEB calibration. Like MODIS, VIIRS BB is nominally controlled at a pre-determined temperature (set point). Periodically, a BB Warm-Up and Cool-Down (WUCD) operation is performed, during which the BB temperatures vary from instrument ambient (temperature) to 315K. This paper examines NPP VIIRS BB on-orbit performance. It focuses on its BB temperature scan-to-scan variations at nominally controlled temperature as well as during its WUCD operation and their impact on TEB calibration uncertainty. Comparisons of VIIRS (NPP) and MODIS (Terra and Aqua) BB on-orbit performance and lessons learned for future improvements are also presented in this paper.

Xiong, Jack↗