Search NASA⌕ Search

SEARCH · Search NASA

Results for “Selectable marker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Combining Ratio Estimation for Low Density Parity Check (LDPC) Coding

The Low Density Parity Check (LDPC) Code decoding algorithm make use of a scaled receive signal derived from maximizing the log-likelihood ratio of the received signal. The scaling factor (often called the combining ratio) in an AWGN channel is a ratio between signal amplitude and noise variance. Accurately estimating this ratio has shown as much as 0.6 dB decoding performance gain. This presentation briefly describes three methods for estimating the combining ratio: a Pilot-Guided estimation method, a Blind estimation method, and a Simulation-Based Look-Up table. The Pilot Guided Estimation method has shown that the maximum likelihood estimates of signal amplitude is the mean inner product of the received sequence and the known sequence, the attached synchronization marker (ASM) , and signal variance is the difference of the mean of the squared received sequence and the square of the signal amplitude. This method has the advantage of simplicity at the expense of latency since several frames worth of ASMs. The Blind estimation method s maximum likelihood estimator is the average of the product of the received signal with the hyperbolic tangent of the product combining ratio and the received signal. The root of this equation can be determined by an iterative binary search between 0 and 1 after normalizing the received sequence. This method has the benefit of requiring one frame of data to estimate the combining ratio which is good for faster changing channels compared to the previous method, however it is computationally expensive. The final method uses a look-up table based on prior simulated results to determine signal amplitude and noise variance. In this method the received mean signal strength is controlled to a constant soft decision value. The magnitude of the deviation is averaged over a predetermined number of samples. This value is referenced in a look up table to determine the combining ratio that prior simulation associated with the average magnitude of the deviation. This method is more complicated than the Pilot-Guided Method due to the gain control circuitry, but does not have the real-time computation complexity of the Blind Estimation method. Each of these methods can be used to provide an accurate estimation of the combining ratio, and the final selection of the estimation method depends on other design constraints.

Mahmoud, Saad↗

TU-G-303-00: Radiomics: Advances in the Use of Quantitative Imaging Used for Predictive Modeling

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-01: Radiomics: Quantitative Imaging in the Service of Improved Treatment Decision Making

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-02: Robust Radiomics Methods for PET and CT Imaging

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-03: Machine Learning to Improve Human Learning From Longitudinal Image Sets

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-04: Radiomics and the Coming Pan-Omics Revolution

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

The Utilization Profiles of the CCSDS Unified Space Link Protocol (USLP)

The purpose of this paper is to identify the utilization profiles for interfacing the Data Protocol Sublayer using the Unified Space Link Protocols (USLP) (reference 1) with the space link coding procedures as specified in the CCSDS Coding & Synchronization Blue Books (references 2 through 5), used in both telecommand and telemetry applications. This paper describes how the USLP Protocol utilizes the coding and synchronization sublayer to support: a. Direct to Earth (DTE) telemetry links for engineering and science data b. Direct to Earth (DTE) telemetry links for very high rate science data c. Direct from Earth (DFE) command, sequencing and flight software loads d. Space to Space Links (Proximity) utilized by orbiters for data exchange to/from surface bound assets. The CCSDS has divided the functions of the Data Link Layer into two sublayers: the Data Link Protocol Sublayer (DLP-SL) and the Coding and Synchronization Sublayer (CS-SL). The Data Link Protocol Sublayer (DLP-SL) interfaces to the users, accepting the data that is to be transported, on the sending side of the link, and delivering that data on the receiving end. The Transfer Frame is the data unit that is transferred across the Data Link Protocol Sublayer and the Coding and Synchronization Sublayer boundary. The Coding and Synchronization Sublayer (CS-SL) provides the encoding, randomization, and frame synchronization functions that prepares the USLP Transfer Frame for transport across the space link. The CS-SL is divided into 2 processes: 1) The Frame Interface Processes (FIP) performs the interface functions required to prepare the data for delivery to the Coding/Decoding Process (CDP). This process includes prepending a Frame Start Marker to the provided frame, when management has designated that the frame is not to be aligned to the codeblock or when there is no block code used. 2) The Coding/Decoding Process (CDP) performs the forward error correction processes that are used to optimize the performance of the link and minimize the error rate. The CDP creates the symbol stream that is delivered to the Physical Layer. The transfer of the USLP transfer frames across different types of space links is the focus of this paper. The Protocol Data Unit (PDU) that is passed in both directions between the Data Link Protocol Sublayer (DLP-SL) and Coding and Synchronization Sublayer (CS-SL) is the transfer frame. The USLP frame structure provides flexibility that can be constrained by the functions utilized within the CS-SL that prepare the transfer frame for transit. For example, the USLP transfer frame contains a length field that enables the frame to be of variable length but CS-SL under certain conditions may constrain the frame to be fixed in length. This paper describes 5 operational modes available for use by the Data Link Layer to provide data exchange across the USLP space link. These modes are different because different operational requirements apply to vastly different types of space links and thus the communications implementation requirements differ. The environmental issues include the power or energy available, the distance between the end points of the link, the complexity of the equipment available at those end points, the atmospheric conditions and radiometric frequency selection. The CS-SL utilizes different forward error correcting codes supported by specific operational modes to configure the data for transit. This paper describes all of the operational modes in a series of data models which decompose the functionality between the Data Link Protocol Sublayer and the Coding and Synchronization sublayer. The operational modes described are: 1. Uncoded Mode: has been used for short links that contain significant available power to provide an acceptable frame error rate. The frames in this mode can be variable in length and typically use an error detection algorithm (i.e., CRC) to determine if there are errors in the received frame. 2. Convolutional Only Mode: is currently the prime forward error correction coding used for the proximity links. The frames in this mode can be variable in length and typically use an error detection algorithm (i.e., CRC) to determine if there are errors in the received frame. 3. Variable Length Frame Aligned to Variable Length Codeblock (TC): is used for Direct from Earth links were power levels are high and the simple, least complex code i.e., the BCH code is used. This mode has been in use since the early 1970s. The BCH code is a short code and the decoder is easy to implement. 4. Fixed Length Frame Aligned to Fixed Length Codeblock (AOS/TM): was introduced when the concatenated Convolutional and Reed-Solomon Code was formulated to provide significant reduction in link data error rate and the ability to determine if there was an error in the decoded codeblock. The frame is aligned to the codeblock so that there is a one to one relationship of frame errors to codeblock errors without additional error detection coding being added. This mode requires the protocol frames to be the exact size of the message portion of the codeblock. 5. Frames Unaligned to Fixed Length Codeblocks (Currently used for very high rates and space to space links): This mode is currently used for missions that have a very high data rate that can be controlled adaptively as the environment changes and as the next generation operating mode for the proximity link. This mode from a coded data stream point of view is exactly like that described in 4. above, except that the frame need not be aligned to the codeblock. There is no requirement on frame length when using this mode. Thus when using USLP it can be used to support links that require short or long frames. There is also no mandatory requirement that frames cannot be separated by idle data reducing the tight data rate connection requirements between the data link protocol sublayer and the coding & synchronization sublayer. In conclusion, how these operational modes can be put to use in mission operational scenarios is described for Direct from Earth links (DFE), Direct to Earth links (DTE), and Proximity links.

Greenberg, E.↗

Neurochemical phenotype of corticocortical connections in the macaque monkey: quantitative analysis of a subset of neurofilament protein-immunoreactive projection neurons in frontal, parietal, temporal, and cingulate cortices

The neurochemical characteristics of the neuronal subsets that furnish different types of corticocortical connections have been only partially determined. In recent years, several cytoskeletal proteins have emerged as reliable markers to distinguish subsets of pyramidal neurons in the cerebral cortex of primates. In particular, previous studies using an antibody to nonphosphorylated neurofilament protein (SMI-32) have revealed a consistent degree of regional and laminar specificity in the distribution of a subpopulation of pyramidal cells in the primate cerebral cortex. The density of neurofilament protein-immunoreactive neurons was shown to vary across corticocortical pathways in macaque monkeys. In the present study, we have used the antibody SMI-32 to examine further and to quantify the distribution of a subset of corticocortically projecting neurons in a series of long ipsilateral corticocortical pathways in comparison to short corticocortical, commissural, and limbic connections. The results demonstrate that the long association pathways interconnecting the frontal, parietal, and temporal neocortex have a high representation of neurofilament protein-enriched pyramidal neurons (45-90%), whereas short corticocortical, callosal, and limbic pathways are characterized by much lower numbers of such neurons (4-35%). These data suggest that different types of corticocortical connections have differential representation of highly specific neuronal subsets that share common neurochemical characteristics, thereby determining regional and laminar cortical patterns of morphological and molecular heterogeneity. These differences in neuronal neurochemical phenotype among corticocortical circuits may have considerable influence on cortical processing and may be directly related to the type of integrative function subserved by each cortical pathway. Finally, it is worth noting that neurofilament protein-immunoreactive neurons are dramatically affected in the course of Alzheimer's disease. The present results support the hypothesis that neurofilament protein may be crucially linked to the development of selective neuronal vulnerability and subsequent disruption of corticocortical pathways that lead to the severe impairment of cognitive function commonly observed in age-related dementing disorders.

Non-NASA Center↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

Nutrient limitation shapes functional traits of mycorrhizal fungi and phosphorus-cycling bacteria across an elevation gradient

In nutrient-limited high-elevation ecosystems, plants rely on arbuscular mycorrhizal (AM) fungi to provide mineral phosphorus (P) in the form of phosphate (PO43-). AM fungi gather these nutrients from phosphorus-cycling bacteria (PCBs) that can mineralize PO43- from organic matter and solubilize mineral-bound P. How climate, soil factors, and nutrient limitation influence AM fungi and PCB assembly remains unclear. We collected soil from montane meadows across a 1,000-m elevation gradient on three replicate mountainsides and analyzed AM fungal marker genes, P-cycling genes from shotgun metagenomes, and edaphic measurements. High-elevation soils had nearly 50-fold less soil PO₄³⁻ and 60% more AM fungal hyphae than low-elevation soils. AM fungal turnover was linked to changes in pH, organic carbon, and PO₄³-. The composition of 198 P-cycling genes was influenced by the AM fungal community structure. Drivers of individual PCB functional genes, including pH and organic carbon, varied with gene phylogeny. We found a trade-off in P-cycling strategies across elevation: P-rich, low-elevation soils supported root-colonizing AM fungi and organic P-mineralizing bacteria. P-poor, high-elevation soils were dominated by stress-tolerant AM fungi and mineral P-solubilizing bacteria. Our results suggest that AM fungi and PCB community turnover across elevation are both shaped by pH, organic carbon, and P availability. With continued climate warming, the structure and function of mountaintop ecosystems might shift to resemble lower elevations, disrupting long-established and specialized microbial assemblages, with consequences for P-cycling dynamics and the total P available to plant communities.IMPORTANCEPhosphorus (P) limits plant productivity in high-elevation ecosystems, yet the microbial networks that mobilize P, including arbuscular mycorrhizal (AM) fungi and phosphorus-cycling bacteria (PCBs), remain under-characterized in these nutrient-poor soils. We show that across a 10,00-m elevation gradient, AM fungi and P-cycling gene assemblages shift predictably with pH, organic carbon, and phosphate availability. Higher elevations, with less available P, select for stress-tolerant AM fungal taxa and PCB strategies geared toward mineral solubilization, while low-elevation sites favor root colonization by AM fungi and organic P mineralization. These results suggest that nutrient limitation can constrain microbial community assembly in consistent ways across landscapes. High mountain soils are low in P and rely on a network of underground AM fungi and PCB to deliver nutrients to plants. This study shows how those underground relationships reorganize with elevation and how climate change could collapse long-standing microbial strategies by pushing high-elevation ecosystems toward lowland conditions. As soils warm and dry, the microbial scaffolding that supports alpine plant life may become increasingly unstable.

arbuscular mycorrhizal fungi↗

Evaluation of the Terminal Area Precision Scheduling and Spacing System for Performance-Based Navigation Arrivals

The growth of global demand for air transportation has put increasing strain on the nation's air traffic management system. To relieve this strain, the International Civil Aviation Organization has urged all nations to adopt Performance-Based Navigation (PBN), which can help to reduce air traffic congestion, decrease aviation fuel consumption, and protect the environment. NASA has developed a Terminal Area Precision Scheduling and Spacing (TAPSS) system that can support increased use of PBN during periods of high traffic, while supporting fuel-efficient, continuous descent approaches. In the original development of this system, arrival aircraft are assigned fuel-efficient Area Navigation (RNAV) Standard Terminal Arrival Routes before their initial descent from cruise, with routing defined to a specific runway. The system also determines precise schedules for these aircraft that facilitate continuous descent through the assigned routes. To meet these schedules, controllers are given a set of advisory tools to precisely control aircraft. The TAPSS system has been evaluated in a series of human-in-the-loop (HITL) air traffic simulations during 2010 and 2011. Results indicated increased airport arrival throughput up to 10 over current operations, and maintained fuel-efficient aircraft decent profiles from the initial descent to landing with reduced controller workload. This paper focuses on results from a joint NASA and FAA HITL simulation conducted in 2012. Due to the FAA rollout of the advance terminal area PBN procedures at mid-sized airports first, the TAPSS system was modified to manage arrival aircraft as they entered Terminal Radar Approach Control (TRACON). Dallas-Love Field airport (DAL) was selected by the FAA as a representative mid-sized airport within a constrained TRACON airspace due to the close proximity of a major airport, in this case Dallas-Ft Worth International Airport, one of the busiest in the world. To address this constraint, RNAV routes and Required Navigation Performance with the particular capability known as Radius-to-Fix (RNP-RF) approaches to a short final were used. The purpose of this simulation was to get feedback on how current operations could benefit with the TAPSS system and also to evaluate the efficacy of the advisory tools to support the broader use of PBN in the US National Airspace System. For this NASA-FAA joint experiment, an Air Traffic Control laboratory at NASA Ames was arranged to simulate arrivals into DAL in Instrument Meteorological Conditions utilizing parallel dependent approaches, with two feeder positions that handed off traffic to one final position. Four FAA controllers participated, alternately covering these three positions. All participants were Full-Performance Level terminal controllers and members of the National Air Traffic Controllers Association. During the simulation, PBN arrival operations were compared and contrasted in three conditions. They were the Baseline, where none of the TAPSS systems TRACON controller decision support advisories were provided, the Limited Advisories, reflecting the existing but dormant capabilities of the current terminal automation equipment with providing a subset of the TAPSS systems advisories; numerical delay, landing sequence, and runway assignment information, and the Full Advisories, with providing the following in addition to the ones in the Limited condition; trajectory slot markers, timelines of estimated times of arrivals and sched

Performance based navigation↗

Molecular Imaging Biomarkers of Resistance to Radiation Therapy for Spontaneous Nasal Tumors in Canines

Purpose: Imaging biomarkers of resistance to radiation therapy can inform and guide treatment management. Most studies have so far focused on assessing a single imaging biomarker. The goal of this study was to explore a number of different molecular imaging biomarkers as surrogates of resistance to radiation therapy. Methods and Materials: Twenty-two canine patients with spontaneous sinonasal tumors were treated with accelerated hypofractionated radiation therapy, receiving either 10 fractions of 4.2 Gy each or 10 fractions of 5.0 Gy each to the gross tumor volume. Patients underwent fluorodeoxyglucose (FDG)-, fluorothymidine (FLT)-, and Cu(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM)-labeled positron emission tomography/computed tomography (PET/CT) imaging before therapy and FLT and Cu-ATSM PET/CT imaging during therapy. In addition to conventional maximum and mean standardized uptake values (SUV{sub max}; SUV{sub mean}) measurements, imaging metrics providing response and spatiotemporal information were extracted for each patient. Progression-free survival was assessed according to response evaluation criteria in solid tumor. The prognostic value of each imaging biomarker was evaluated using univariable Cox proportional hazards regression. Multivariable analysis was also performed but was restricted to 2 predictor variables due to the limited number of patients. The best bivariable model was selected according to pseudo-R{sup 2}. Results: The following variables were significantly associated with poor clinical outcome following radiation therapy according to univariable analysis: tumor volume (P=.011), midtreatment FLT SUV{sub mean} (P=.018), and midtreatment FLT SUV{sub max} (P=.006). Large decreases in FLT SUV{sub mean} from pretreatment to midtreatment were associated with worse clinical outcome (P=.013). In the bivariable model, the best 2-variable combination for predicting poor outcome was high midtreatment FLT SUV{sub max} (P=.022) in combination with large FLT response from pretreatment to midtreatment (P=.041). Conclusions: In addition to tumor volume, pronounced tumor proliferative response quantified using FLT PET, especially when associated with high residual FLT PET at midtreatment, is a negative prognostic biomarker of outcome in canine tumors following radiation therapy. Neither FDG PET nor Cu-ATSM PET were predictive of outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

INSIGHTS INTO MARINE UNICELLULAR CYANOBACTERIAL AND NON-CYANOBACTERIAL DIAZOTROPHS THROUGH SINGLE-CELL ANALYSES

Nutrient availability affects primary productivity, and nitrogen (N) is the limiting nutrient over large regions of the ocean. Biological N fixation (BNF) is the conversion of atmospheric dinitrogen (N2) to bioavailable forms of N (ammonium and amino acids). A select group of Bacteria and Archaea, known as diazotrophs, are the only organisms capable of this conversion. BNF is a critical source of N in nutrient-depleted (oligotrophic) marine waters. As such, BNF studies are a fundamental component for better understanding primary productivity and carbon cycling, as well as parameterizing predictive future global ocean models. Unicellular diazotrophs are widespread in marine systems and, in some cases, important contributors of BNF. This dissertation investigates unicellular diazotrophs at the single-cell level, including: UCYN-A, a cyanobacterial diazotroph that lives in symbiosis with an algal host, non-cyanobacterial diazotrophs (NCDs), which are putative heterotrophs, as well as a specific NCD known as Gamma A, a commonly occurring organism throughout the tropics and subtropics that belongs to the class Gammaproteobacteria. The single-cell investigations used in these studies can provide high-resolution insights that are not possible from community-level analyses of BNF, such as the N2 fixation rate of individual cells and cell morphology. Singlecell nanoscale secondary ion mass spectrometry (nanoSIMS) analyses were used in chapter 2 and 3 to investigate the cell-specific N2 fixation rates of (2) UCYN-A in the viii cold waters of the Bering and Arctic Seas where N2 fixation was not previously believed to be possible, and (3) NCDs in the North Pacific Subtropical Gyre where we demonstrated the first direct evidence of NCD N2 fixation on open ocean particles. Chapter 4 focused on the uncultivated NCD, Gamma A, using geneFISH to visualize single cells in natural seawater samples. We successfully identified Gamma A by developing a fluorescent in situ hybridization (FISH) probe targeting the diazotrophic functional marker gene nifH, revealing Gamma A cells are most often attached to particles. Together these studies provide new insights into the distributions, activities, and physiologies of geographically widespread, unicellular diazotrophs, thus improving our understanding of their roles as sources of fixed N in the surface ocean.

Harding, K.↗

WE-FG-202-10: Assessing Hepatocellular Carcinoma (HCC) Response to SBRT Using DCE-MRI

Purpose: To investigate the feasibility of using DCE-MRI to assess treatment response of HCC to SBRT. Methods: For seven liver HCC patients treated by photon SBRT with radiation dose ranging from 35 to 50 Gy in 5 fractions, T1-weighted DCE-MRI was performed before and at 1–3 months after the treatment. Each study included one pre-contrast and five post Gd-EOB-DTPA-enhanced imaging series. The target tumor and the liver were manually outlined on the arterial phase images. Then, a regional deformable image registration was applied to align liver volumes at different phases in order to compensate respiratory and cardiac motions. An unsupervised fuzzy c-means clustering technique was carried out to partition the tumor voxels into a number of groups based on their enhancement patterns over time. The representative kinetic curve of the tumor was selected as the one with the maximum enhancement. Six semi-quantitative features were extracted to depict the maximum contrast enhancement, uptake rate, washout rate, time to peak, the area under the kinetic curve (AUKC), as well as the ratio of the most enhanced area in each tumor. The change of these feature values after SBRT was compared using Wann-Whiteney test to characterize the tumor response to RT. Results: Eight HCCs from these seven patients were included in this retrospective study, in which four were identified to respond well to SBRT. The responding tumors showed reduced enhancement after SBRT while the non-responding tumors had steady or even enhanced kinetic dynamics. The median AUKC change after SBRT was −0.65 for responding tumors and 1.0165 for non-responding tumors (p=0.029) Conclusion: The preliminary results demonstrate that DCE-MRI has the potential to monitor the effects of SBRT in patients with HCC. We are expanding our database and developing more quantitative imaging biomarkers in the future study.

60 APPLIED LIFE SCIENCES↗

Zircon, Baddeleyite, and Reidite Found in Ries Crater Suevite

Introduction: Impact events can generate superheated impact melts and even vapor [1]. In the past decade, evidence of the high temperatures and high pressures of the impact process has been found in the impact melt from terrestrial craters (e.g., Mistastin Lake [2], Meteor Crater [3]) and even on the Moon [4–5]. Often, these studies involve zircon or zirconium-bearing phases. Zircon is a particularly useful mineral, due to its robustness and durability against weathering. It is used principally for chronology, but it has a multitude of geologic applications, including geothermometry and fingerprinting magma sources. Here we focus on its capability of recording impact conditions. Grains of zircon (ZrSiO4) are converted at high temperature and/or pressure during an impact event to reidite (a high-pressure polymorph of ZrSiO4) or to tetragonal-ZrO2 + SiO2 [6]. Reidite and tertragonal-ZrO2 leave identifying relicts in the rocks, markers of the high pressures and/or temperatures these rocks underwent. Ries Crater is a 26-km-diameter peak ring crater in southern Germany that formed approximately 15 Ma [7–9]. Ries is the type locality of the polymict impact breccia known as suevite. Here, we report a microanalytical study of suevite from the Ries impact structure. These analyses are used to inform our understanding of the pressure and temperature conditions involved in creating a polymict impact breccia such as suevite in a peak ring crater. Sample Description: The sample, denoted 16RS08, originates from Otting Quarry, at 48.8777° N, 10.7921° E, approximately 17 km from the center of the Ries Crater in Germany (approximately 4 km outside the crater rim). The material recorded in sample 16RS08 is therefore considered an outer suevite. The outer suevite is a discontinuous layer of polymict impact breccia that occurs outside the central ring of Ries, up to 22 km from the center of the crater [9]. Lithic clasts in the outer suevite consist primarily of crystalline basement rocks (gneiss, granite, amphibolite), with less than 5% of lithic clasts being overlying sedimentary rocks (limestone, sandstone, shale) [9]. The thin section studied contains variably shocked lithic and mineral clasts, impact glass, and interstitial minerals that make up the matrix of the breccia (Fig. 1) [9]. Methods: We used a Cameca SX100 electron probe microanalyzer (EPMA) located in the Kuiper Materials Imaging and Characterization Facility (KMICF) at the University of Arizona to obtain 15 elemental X-ray maps of 16RS08. We next used the JEOL 7900F SEM at the Astromaterials Research & Exploration Science (ARES) at NASA Johnson Space Center (JSC) to obtain electron backscatter diffraction (EBSD) maps and energy dispersive X-ray spectroscopy (EDS) maps of select portions of the section. The EBSD data were collected under beam conditions of 20 kV, and ~9 μA, with step sizes varying from 0.05 to 2 μm. Following EBSD data collection, we processed the data using AZtecCrystal and MTEX, a free MATLAB toolbox. Results: We used the elemental X-ray maps to identify the areas of interest in the section, particularly phosphates and Zr-bearing grains. These areas of interest were then targeted for follow up EBSD and EDS analyses. We have identified, through combined EBSD and EDS analysis, the presence of zircon, reidite, and monoclinic-ZrO2 (baddeleyite) in 16RS08. In 16RS08, we have found singular grains of zircon, zircon with a vermicular baddeleyite halo (Fig. 2a), and granular zircon with reidite (Fig. 2b). The different Zr-rich phases and their corresponding textures signifies that this sample underwent a broad spectrum of pressure and temperature conditions during the impact event. For example, zircons surrounded by a vermicular baddeleyite and SiO2 intergrowth (i.e., Fig. 2a) have been shown to preserve evidence of the extremely high temperatures of impact melt, upwards of 2370 °C [2, 6]. Similarly, reidite and granular zircon (i.e., Fig. 2b) have been shown to preserve evidence of high pressure, as the transition to reidite occurs >30 GPa [3, 6]. Future Work: Next, we will process the EBSD and EDS data for these Zr-rich grains, specifically looking for indicators of cubic- or tetragonal-ZrO2 in the baddeleyite remnants and of shock-precursors to the reidite. To further inform our work, we will also obtain BSE images of these grains using a Hitachi S-4800 SEM in KMICF at the University of Arizona, as well as geochemical spot analyses via EPMA. The data collected will be used to constrain the formation conditions of the Ries Crater outer suevite. Acknowledgments: We thank Ken Domanik and Jerry Chang for their support with data collection. This work was supported by a University of Arizona RII Core Facilities Pilot Program grant and start-up funds to JJB. TME thanks A. Cavosie and N. Timms for assistance during field sampling. We acknowledge support from NASA’s Planetary Science Research program for analysis performed at JSC. References: [1] Melosh H. J. (1989) Oxf. U. Press. [2] Timms et al. (2017) EPSL 477, 52–58. [3] Cavosie et al. (2016) Geology 44:9, 703–706. [4] White et al. (2020) Nature Astr. 4, 974–978. [5] Crow C. A. et al. (2017) GCA 202, 264–284. [6] Timms et al. (2017) Earth-Sci. Rev. 165, 185–202. [7] Schmieder M. et al. (2018) GCA 220, 146–157. [8] Schwarz W. H. et al. (2020) M&PS 55:2, 312–325. [9] Stöffler et al. (2013) M&PS 43:4, 515–589.

Zircon↗

WE-E-BRE-05: Ensemble of Graphical Models for Predicting Radiation Pneumontis Risk

Purpose: We propose a prior knowledge-based approach to construct an interaction graph of biological and dosimetric radiation pneumontis (RP) covariates for the purpose of developing a RP risk classifier. Methods: We recruited 59 NSCLC patients who received curative radiotherapy with minimum 6 month follow-up. 16 RP events was observed (CTCAE grade ≥2). Blood serum was collected from every patient before (pre-RT) and during RT (mid-RT). From each sample the concentration of the following five candidate biomarkers were taken as covariates: alpha-2-macroglobulin (α2M), angiotensin converting enzyme (ACE), transforming growth factor β (TGF-β), interleukin-6 (IL-6), and osteopontin (OPN). Dose-volumetric parameters were also included as covariates. The number of biological and dosimetric covariates was reduced by a variable selection scheme implemented by L1-regularized logistic regression (LASSO). Posterior probability distribution of interaction graphs between the selected variables was estimated from the data under the literature-based prior knowledge to weight more heavily the graphs that contain the expected associations. A graph ensemble was formed by averaging the most probable graphs weighted by their posterior, creating a Bayesian Network (BN)-based RP risk classifier. Results: The LASSO selected the following 7 RP covariates: (1) pre-RT concentration level of α2M, (2) α2M level mid- RT/pre-RT, (3) pre-RT IL6 level, (4) IL6 level mid-RT/pre-RT, (5) ACE mid-RT/pre-RT, (6) PTV volume, and (7) mean lung dose (MLD). The ensemble BN model achieved the maximum sensitivity/specificity of 81%/84% and outperformed univariate dosimetric predictors as shown by larger AUC values (0.78∼0.81) compared with MLD (0.61), V20 (0.65) and V30 (0.70). The ensembles obtained by incorporating the prior knowledge improved classification performance for the ensemble size 5∼50. Conclusion: We demonstrated a probabilistic ensemble method to detect robust associations between RP covariates and its potential to improve RP prediction accuracy. Our Bayesian approach to incorporate prior knowledge can enhance efficiency in searching of such associations from data. The authors acknowledge partial support by: 1) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290) and 2) The Terry Fox Foundation Strategic Training Initiative for Excellence in Radiation Research for the 21st Century (EIRR21)

60 APPLIED LIFE SCIENCES↗

WE-H-207A-03: The Universality of the Lognormal Behavior of [F-18]FLT PET SUV Measurements

Purpose: Log transforming [F-18]FDG PET standardized uptake values (SUVs) has been shown to lead to normal SUV distributions, which allows utilization of powerful parametric statistical models. This study identified the optimal transformation leading to normally distributed [F-18]FLT PET SUVs from solid tumors and offers an example of how normal distributions permits analysis of non-independent/correlated measurements. Methods: Forty patients with various metastatic diseases underwent up to six FLT PET/CT scans during treatment. Tumors were identified by nuclear medicine physician and manually segmented. Average uptake was extracted for each patient giving a global SUVmean (gSUVmean) for each scan. The Shapiro-Wilk test was used to test distribution normality. One parameter Box-Cox transformations were applied to each of the six gSUVmean distributions and the optimal transformation was found by selecting the parameter that maximized the Shapiro-Wilk test statistic. The relationship between gSUVmean and a serum biomarker (VEGF) collected at imaging timepoints was determined using a linear mixed effects model (LMEM), which accounted for correlated/non-independent measurements from the same individual. Results: Untransformed gSUVmean distributions were found to be significantly non-normal (p<0.05). The optimal transformation parameter had a value of 0.3 (95%CI: −0.4 to 1.6). Given the optimal parameter was close to zero (which corresponds to log transformation), the data were subsequently log transformed. All log transformed gSUVmean distributions were normally distributed (p>0.10 for all timepoints). Log transformed data were incorporated into the LMEM. VEGF serum levels significantly correlated with gSUVmean (p<0.001), revealing log-linear relationship between SUVs and underlying biology. Conclusion: Failure to account for correlated/non-independent measurements can lead to invalid conclusions and motivated transformation to normally distributed SUVs. The log transformation was found to be close to optimal and sufficient for obtaining normally distributed FLT PET SUVs. These transformations allow utilization of powerful LMEMs when analyzing quantitative imaging metrics.

60 APPLIED LIFE SCIENCES↗