Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Integration of Thermoelectric Generator and Wireless Sensor Node Simulators

This report focuses on integrating TEG and WSN simulators with DC-DC converter as an interface. Here DC stands for direct current. DC-DC converter is essential to balance a wide range of analog, digital, and radio loads acting on the energy source. Also, the voltage level generated by TEGs under varying temperature conditions could be low, irregular, and insufficient to operate WSN, therefore DC-DC is required to boost up the voltage to a desired level. Most of the main problems of DC-DC converters used in TEG system are related to impedance matching between the internal resistance of TEG and the input resistance of DC-DC converter. This report would address the issue associated with dynamic impedance matching under varying temperature conditions in the effort to integrate TEG and WSN. In this effort, dynamic impedance matching algorithms like perturb and observe (P&O) and extremum seeking control (ESC) algorithms will de implemented and compared to achieve maximum peak power tracking (MPPT). In addition, the report will summarize the experimental study performed at BSU on profiling behavior of WSN prototype.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEMS Applications in Aerodynamic Measurement Technology

Microelectromechanical systems (MEMS) embodies the integration of sensors, actuators, and electronics on a single substrate using integrated circuit fabrication techniques and compatible bulk and surface micromachining processes. Silicon and its derivatives form the material base for the MEMS technology. MEMS devices, including microsensors and microactuators, are attractive because they can be made small (characteristic dimension about 100 microns), be produced in large numbers with uniform performance, include electronics for high performance and sophisticated functionality, and be inexpensive. For aerodynamic measurements, it is preferred that sensors be small so as to approximate measurement at a point, and in fact, MEMS pressure sensors, wall shear-stress sensors, heat flux sensors and micromachined hot wires are nearing application. For the envisioned application to wind tunnel models, MEMS sensors can be placed on the surface or in very shallow grooves. MEMS devices have often been fabricated on stiff, flat silicon substrates, about 0.5 mm thick, and therefore were not easily mounted on curved surfaces. However, flexible substrates are now available and heat-flux sensor arrays have been wrapped around a curved turbine blade. Electrical leads can also be built into the flexible substrate. Thus MEMS instrumented wind tunnel models do not require deep spanwise grooves for tubes and leads that compromise the strength of conventionally instrumented models. With MEMS, even the electrical leads can potentially be eliminated if telemetry of the signals to an appropriate receiver can be implemented. While semiconductor silicon is well known for its electronic properties, it is also an excellent mechanical material for MEMS applications. However, silicon electronics are limited to operations below about 200 C, and silicon's mechanical properties start to diminish above 400 C. In recent years, silicon carbide (SiC) has emerged as the leading material candidate for applications in high temperature environments and can be used for high-temperature MEMS applications. With SiC, diodes and more complex electronics have been shown to operate to about 600 C, while the mechanical properties of SiC are maintained to much higher temperatures. Even when MEMS devices show benefits in the laboratory, there are many packaging challenges for any aeronautics application. Incorporating MEMS into these applications requires new approaches to packaging that goes beyond traditional integrated circuit (IC) packaging technologies. MEMS must interact mechanically, as well as electrically with their environment, making most traditional chip packaging and mounting techniques inadequate. Wind tunnels operate over wide temperature ranges in an environment that is far from being a 'clean-room.' In flight, aircraft are exposed to natural elements (e.g. rain, sun, ice, insects and dirt) and operational interferences(e.g. cleaning and deicing fluids, and maintenance crews). In propulsion systems applications, MEMS devices will have to operate in environments containing gases with very high temperatures, abrasive particles and combustion products. Hence deployment and packaging that maintains the integrity of the MEMS system is crucial. This paper presents an overview of MEMS fabrication and materials, descriptions of available sensors with more details on those being developed in our laboratories, and a discussion of sensor deployment options for wind tunnel and flight applications.

Reshotko, E.↗

A Prototype Wire Position Monitoring System

The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1{micro}m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1{micro}m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

43 PARTICLE ACCELERATORS↗

Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

Bekdash, Omar↗

1st Order Modeling of a SAW Delay Line using MathCAD(Registered)

To aid in the development of SAW sensors for Integrated Vehicle Health Monitoring applications, a first order model of a SAW Delay line has been created using MathCadA. The model implements the Impulse Response method to calculate the frequency response, impedance, and insertion loss. This paper presents the model and the results from the model for a SAW delay line design. Integrated Vehicle Health Monitoring (IVHM) of aerospace vehicles requires rugged sensors having reduced volume, mass, and power that can be used to measure a variety of phenomena. Wireless systems are preferred when retro-fitting sensors onto existing vehicles [1]. Surface Acoustic Wave (SAW) devices are capable of sensing: temperature, pressure, strain, chemical species, mass loading, acceleration, and shear stress. SAW technology is low cost, rugged, lightweight, and extremely low power. Passive wireless sensors have been developed using SAW technology. For these reasons new SAW sensors are being investigated for aerospace applications.

Wilson, William C.↗

Integrated Communication and Control Systems. III - Nonidentical sensor and controller sampling

Networking in Integrated Communication and Control Systems (ICCS) introduces randomly varying delays which degrade the system dynamic performance and are a source of potential instability. In Part I of this sequence of papers, a discrete-time, finite-dimensional model of the delayed control system for analysis and design of ICCS was developed where the sensor and controller have identical sampling rates. In Part II, two alternate approaches for ICCS design, namely, identical and nonidentical sampling rates for sensor and controller were proposed. This Part III presents extended modeling of ICCS for nonidentical sensor and controller sampling rates. This model is also suitable for analyzing tracking problems, i.e., control systems with time-dependent reference inputs.

Liou, Luen-Woei↗

Multi-Parameter Nonlinear Gain Correction of X-Ray Transition Edge Sensors for the X-Ray Integral Field Unit

With its array of 3840 Transition Edge Sensors (TESs), the Athena X-ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV up to 7 keV) from 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in systematic errors in the absolute energy scale. We plan to monitor such changes at pixel level via onboard X-ray calibration sources and correct the energy scale accordingly using a linear or quadratic interpolation of gain curves obtained during ground calibration. However, this may not be sufficient to meet the 0.4 eV accuracy required for the XIFU. In this contribution, we introduce a newtwo-parameter gain correction technique, based on both the pulse-height estimate of a fiducial line and the baseline value of the pixels. Using gain functions that simulate ground calibration data, we show that this technique can accurately correct deviations in detector gain due to changes in TES operating conditions such as heat sink temperature, bias voltage, thermal radiation loading and linear amplifier gain. We also address potential optimisations of the onboard calibration source and compare the performance of this new technique with those previously used.

Cucchetti, E.↗

Spatial Grid-Based Object Localization from A Single Passive Sensor: A Deep Learning-Integrated Approach

Ongoing efforts at NASA’s Langley Research Center have produced a single passive sensor system for detecting ground objects and pinpointing their real-world location to a desired level of precision. The Langley center serves as a test range for unmanned aerial systems (UAS) and real-time knowledge about the location of people on campus is needed to inform least-risk UAS flight operations. The proposed system provides this knowledge through a camera combined with a convolutional neural network and an algorithm that projects an imaginary grid of square cells from the ground plane onto the perspective view of the camera. The position of detected objects on the camera’s projected grid determines their location in the real-world. The imaginary grid is easily mapped to a universal coordinate system, such as longitude and latitude, to provide both relative and absolute positional information of the detected objects. This simple system is shown to be accurate and effective, with decisive advantages over alternative multi-sensor and active sensor approaches. Extensions to the system are described to allow adaptation to a variety of other use cases.

object localization↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High quality single crystal Ge nano-membranes for opto-electronic integrated circuitry

A thin, flat, and single crystal germanium membrane would be an ideal platform on which to mount sensors or integrate photonic and electronic devices, using standard silicon processing technology. We present a fabrication technique compatible with integrated-circuit wafer scale processing to produce membranes of thickness between 60 nm and 800 nm, with large areas of up to 3.5 mm{sup 2}. We show how the optical properties change with thickness, including appearance of Fabry-Pérot type interference in thin membranes. The membranes have low Q-factors, which allow the platforms to counteract distortion during agitation and movement. Finally, we report on the physical characteristics showing sub-nm roughness and a homogenous strain profile throughout the freestanding layer, making the single crystal Ge membrane an excellent platform for further epitaxial growth or deposition of materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carbon nanotube based pressure sensor for flexible electronics

Highlights: • The electromechanical change of vertically aligned carbon nanotubes. • Fabrication of CNT field-effect transistor on flexible substrate. • CNT based FET integrated active pressure sensor. • The integrated device yields an increase in the source-drain current under pressure. - Abstract: A pressure sensor was developed based on an arrangement of vertically aligned carbon nanotubes (VACNTs) supported by a polydimethylsiloxane (PDMS) matrix. The VACNTs embedded in the PDMS matrix were structurally flexible and provided repeated sensing operation due to the high elasticities of both the polymer and the carbon nanotubes (CNTs). The conductance increased in the presence of a loading pressure, which compressed the material and induced contact between neighboring CNTs, thereby producing a dense current path and better CNT/metal contacts. To achieve flexible functional electronics, VACNTs based pressure sensor was integrated with field-effect transistor, which is fabricated using sprayed semiconducting carbon nanotubes on plastic substrate.

36 MATERIALS SCIENCE↗

Low Noise Frequency-Domain Multiplexing of TES Bolometers Using SQUIDs at Sub-Kelvin Temperature

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of transition edge sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3 G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single-carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz1 1/2 , which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.

47 OTHER INSTRUMENTATION↗

Software Considerations for Subscale Flight Testing of Experimental Control Laws

The NASA AirSTAR system has been designed to address the challenges associated with safe and efficient subscale flight testing of research control laws in adverse flight conditions. In this paper, software elements of this system are described, with an emphasis on components which allow for rapid prototyping and deployment of aircraft control laws. Through model-based design and automatic coding a common code-base is used for desktop analysis, piloted simulation and real-time flight control. The flight control system provides the ability to rapidly integrate and test multiple research control laws and to emulate component or sensor failures. Integrated integrity monitoring systems provide aircraft structural load protection, isolate the system from control algorithm failures, and monitor the health of telemetry streams. Finally, issues associated with software configuration management and code modularity are briefly discussed.

Murch, Austin M.↗