Search NASA⌕ Search

SEARCH · Search NASA

Results for “System specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Multi-Harmonic System Identification Method for Internal Circuit Element Monitoring

Many critical infrastructures depend on the reliability of electronic circuits, whose health depends on the values of internal circuit elements that degrade over time. It is therefore important to estimate the values of internal circuit elements from external measurements and monitor them for changes. The challenge to doing so is that, typically, the internal voltages and currents are not accessible for measurement. Prior work on internal circuit element monitoring uses data obtained from sensors placed inside the circuit or requires additional circuitry to be added to the given system, both of which are undesirable. We propose a new multi-harmonic frequency-domain based system identification method that is non-intrusive. It exploits the latent non-idealities already present in the system, specifically harmonics in the measured input and output signals. We show how sensitivity analysis can be used to both assess the accuracy of the method as well as to optimize the choice of harmonics to use. We use as a motivation and illustrative example the problem of determining the equivalent series resistance and capacitance in a class of dc-link capacitance circuits in Adjustable Speed Drives. We assess the performance of this method using simulations, and establish its validity by experimental results.

Deshpande, Ankit Vivek↗

Role of the Reference Bus in Three-Phase State Estimation

As more and more renewable energy sources are being connected to the power grid at lower voltage levels, closer monitoring of distribution networks is becoming a necessity. This is accomplished by state estimation and deployment of Distribution Management Systems (DMS). Distribution feeders are typically untransposed with unbalance loads. Thus, their modeling and analysis show significant differences compared to those for transmission networks. This paper focuses on the state estimation problem and its formulation for unbalanced distribution systems. Specifically, it is concerned about the modeling and solution of three-phase networks without a fully balanced bus to be selected as the angle reference. It is shown that best results will be obtained via the use of a virtual symmetrical bus. Validation of the proposed formulation is carried out by simulations.

Langner, A. L.↗

Cybersecurity Value-at-Risk Framework

As more variable renewable energy sources are added to the grid, the role of hydropower as a reliable baseline and firming resource is growing more critical. However, the U.S hydropower fleet is not fully prepared to face modern issues such as cybersecurity threats. Hydropower accounts for 37% of U.S. utility-scale renewable electricity but is challenged by diverse infrastructure and legacy devices that predate modern security practices. While new cybersecurity solutions cannot simply be added to current hydropower generation and operation technologies, custom cybersecurity assessments can reveal system-specific threats and risk probabilities and identify mitigating enhancements.

cybersecurity valuation methodology↗

Scalable Triadic Analysis of Large-Scale Graphs: Multi-Core vs. Multi-Processor vs. Multi-Threaded Shared Memory Architectures

Triadic analysis encompasses a useful set of graph mining methods that is centered on the concept of a triad, which is a subgraph of three nodes and the configuration of directed edges across the nodes. Such methods are often applied in the social sciences as well as many other diverse fields. Triadic methods commonly operate on a triad census that counts the number of triads of every possible edge configuration in a graph. Like other graph algorithms, triadic census algorithms do not scale well when graphs reach tens of millions to billions of nodes. To enable the triadic analysis of large-scale graphs, we developed and optimized a triad census algorithm to efficiently execute on shared memory architectures. We will retrace the development and evolution of a parallel triad census algorithm. Over the course of several versions, we continually adapted the code’s data structures and program logic to expose more opportunities to exploit parallelism on shared memory that would translate into improved computational performance. We will recall the critical steps and modifications that occurred during code development and optimization. Furthermore, we will compare the performances of triad census algorithm versions on three specific systems: Cray XMT, HP Superdome, and AMD multi-core NUMA machine. These three systems have shared memory architectures but with markedly different hardware capabilities to manage parallelism.

Triadic analysis, triads, triad census, large-scal↗

The Anatomy of Mr. Scan: A Dissection of Performance of an Extreme Scale GPU-Based Clustering Algorithm, In: 2014 5th Workshop on Latest Advances in Scalable Algorithms for Large-Scale Systems

The emergence of leadership class systems with GPU-equipped nodes has the potential to vastly increase the performance of existing distributed applications. However, the inclusion of GPU computation into existing extreme scale distributed applications can reveal scalability issues that were absent in the CPU version. The issues exposed in scaling by a GPU can become limiting factors to overall application performance. We developed an extreme scale GPU-based application to perform data clustering on multi-billion point datasets. In this application, called Mr. Scan, we ran into several of these performance limiting issues. Through the use of complete end-to-end benchmarking of Mr. Scan (measuring time from reading and distribution to final output), we were able to identify three major sources of real world performance issues: data distribution, GPU load balancing, and system specific issues such as start-up time. These issues comprised a vast majority of the run time of Mr. Scan. Data distribution alone accounted for 68% of the total run time of Mr. Scan when processing 6.5 billion points on Cray Titan at 8192 nodes. With improvements in these areas, we have been able able to cut total run time of Mr. Scan from 17.5 minutes to 8.3 minutes when clustering 6.5 billion points.

Computer Science↗

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Behavior of Distribution System Discrete Control Devices for Cyber-Physical Security

Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of reactively sputtered oxygenated cadmium sulfide (CdS:O) and their impact on CdTe solar cell performance

Oxygenated cadmium sulfide (CdS:O) is commonly used as the n-type window layer in high-performance CdTe heterojunction solar cells. This layer is deposited by reactive sputtering, but the optimal amount of oxygen in the sputtering ambient is highly dependent on the specific system and process employed. In this work, the intrinsic properties of CdS:O were measured as a function of the oxygen content (0%–10%) in the sputtering ambient and correlated to device performance with the goal of better defining optimal CdS:O properties for CdTe solar cells. Optimal performance was found using CdS:O films that contained ∼40 at. % oxygen as measured by Rutherford backscattering spectrometry. X-ray photoelectron spectroscopy confirmed these results and showed that oxygen is incorporated primarily as oxygenated sulfur compounds (SO{sub x}). Device efficiency improved from 10.5% using CdS to >14% with CdS:O due largely to increases in short-circuit current density as well as a modest improvement in open-circuit voltage. The transparency of the CdS:O films was well correlated with observed improvements in blue quantum efficiency with increasing oxygen content. The optical bandgap of as-deposited CdS:O was identified as a simple metric for process optimization and transfer, with 2.8 eV being ideal for the device architecture employed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dosimetric characterization of a multileaf collimator for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000

Purpose: To present the dosimetric characterization of a multileaf collimator (MLC) for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000. Methods: MHI-TM2000 has an x-ray head composed of an ultrasmall linear accelerator guide and a system-specific MLC. The x-ray head can rotate along the two orthogonal gimbals (pan and tilt rotations) up to {+-}2.5 deg., which swings the beam up to {+-}41.9 mm in each direction from the isocenter on the isocenter plane perpendicular to the beam. The MLC design is a single-focus type, has 30 pairs of 5 mm thick leaves at the isocenter, and produces a maximum field size of 150x150 mm{sup 2}. Leaf height and length are 110 and 260 mm, respectively. Each leaf end is circular, with a radius of curvature of 370 mm. The distance that each leaf passes over the isocenter is 77.5 mm. Radiation leakage between adjacent leaves is minimized by an interlocking tongue-and-groove (T and G) arrangement with the height of the groove part 55 mm. The dosimetric characterizations including field characteristics, leaf position accuracy, leakage, and T and G effect were evaluated using a well-commissioned 6 MV photon beam, EDR2 films (Kodak, Rochester, NY), and water-equivalent phantoms. Furthermore, the field characteristics and leaf position accuracy were evaluated under conditions of pan or tilt rotation. Results: The differences between nominal and measured field sizes were within {+-}0.5 mm. Although the penumbra widths were greater with wider field size, the maximum width was <5.5 mm even for the fully opened field. Compared to the results of field characteristics without pan or tilt rotation, the variation in field size, penumbra width, flatness, and symmetry was within {+-}1 mm/1% at the maximum pan or tilt rotational angle. The leaf position accuracy was 0.0{+-}0.1 mm, ranging from -0.3 to 0.2 mm at four gantry angles of 0 deg., 90 deg., 180 deg., and 270 deg. with and without pan or tilt rotation. The interleaf leakage was up to 0.21%, whereas the intraleaf leakage was <0.12%. T and G decreased the doses by 10.7%, on average. Conclusions: This study demonstrated that MHI-TM2000 has the capability for high leaf position accuracy and low leakage, leading to highly accurate intensity-modulated radiotherapy delivery. Furthermore, substantial changes in the dosimetric data on field characteristics and leaf position accuracy were not observed even at the maximum pan or tilt rotation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric evaluation of photon dose calculation under jaw and MLC shielding

Purpose: The accuracy of photon dose calculation algorithms in out-of-field regions is often neglected, despite its importance for organs at risk and peripheral dose evaluation. The present work has assessed this for the anisotropic analytical algorithm (AAA) and the Acuros-XB algorithms implemented in the Eclipse treatment planning system. Specifically, the regions shielded by the jaw, or the MLC, or both MLC and jaw for flattened and unflattened beams have been studied.Methods: The accuracy in out-of-field dose under different conditions was studied for two different algorithms. Measured depth doses out of the field, for different field sizes and various distances from the beam edge were compared with the corresponding AAA and Acuros-XB calculations in water. Four volumetric modulated arc therapy plans (in the RapidArc form) were optimized in a water equivalent phantom, PTW Octavius, to obtain a region always shielded by the MLC (or MLC and jaw) during the delivery. Doses to different points located in the shielded region and in a target-like structure were measured with an ion chamber, and results were compared with the AAA and Acuros-XB calculations. Photon beams of 6 and 10 MV, flattened and unflattened were used for the tests.Results: Good agreement between calculated and measured depth doses was found using both algorithms for all points measured at depth greater than 3 cm. The mean dose differences (±1SD) were −8%± 16%, −3%± 15%, −16%± 18%, and −9%± 16% for measurements vs AAA calculations and −10%± 14%, −5%± 12%, −19%± 17%, and −13%± 14% for Acuros-XB, for 6X, 6 flattening-filter free (FFF), 10X, and 10FFF beams, respectively. The same figures for dose differences relative to the open beam central axis dose were: −0.1%± 0.3%, 0.0%± 0.4%, −0.3%± 0.3%, and −0.1%± 0.3% for AAA and −0.2%± 0.4%, −0.1%± 0.4%, −0.5%± 0.5%, and −0.3%± 0.4% for Acuros-XB. Buildup dose was overestimated with AAA, while Acuros-XB gave results more consistent with measurements. From RapidArc plan analysis the average difference between calculation and measurement in the shielded region was −0.3%± 0.4% and −2.5%± 1.2% for AAA and Acuros-XB, respectively, relative to the mean target dose value (1.6%± 2.3%, −12.7%± 4.0% if relative to each local value). These values were compared with the corresponding differences in the target structure: −0.7%± 2.3% for AAA, and −0.5%± 2.3% for Acuros-XB.Conclusions: The two algorithms analyzed showed encouraging results in predicting out-of-field region dose for clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-PIS-Exhibit Hall-01: CT Dose Optimization Technologies II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Siemens‘ Commitment to the Right Dose in Computed Tomography Presentation Time: 11:15 - 11:45 AM Providing sustainable clinical results at highest patient safety: This is the challenge in medical imaging. Especially for Computed Tomography this means applying not simply the lowest, but the right dose for sound diagnostic imaging. Consequently, Siemens is committed to deliver the right dose in CT. In order to reduce radiation to the right dose, the first step is to provide the right dose technology. Through decades of research and development in CT imaging, Siemens CT has constantly introduced new ideas leading to a comprehensive portfolio of unique CARE technologies to deliver the right dose. For example automated kV adjustment based on patient size and the clinical question with CARE kV and three generations of iterative reconstruction. Based on the right dose technology, the next step is to actually scan at the right dose. For this, it is key to know the right dose targets for every examination. Siemens continuously involves CT experts to push developments further and outline how users can best adapt their procedures to the right dose. For users to know whether they met the right dose targets, it is therefore important to understand and monitor the actual absolute dose values. All scanners are delivered with defined default protocols which automatically use the available right dose technologies. Finally, to deliver the right dose not just in singular cases, but ideally to patients everywhere, organizations need then to manage dose across their institutions. Here Siemens offers the right dose management tools for administrations to analyze and document dose, to train their clinical staff and to continuously optimize the application of the right dose in clinical routine. Siemens CT is not only adhering to the ALARA principle, but is inspired by it. With CARE Right Siemens show their commitment to the right dose in CT. Toshiba Aquilion CT Dose Management Tools Presentation Time: 11:45 - 12:15 PM A practical review of Toshiba’s CT dose management technologies from the physicist’s perspective. This presentation will include an overview of Toshiba’s CT dose reduction technologies and dose safeguards. Content will include answers to frequently asked questions relating to dose management, dose tracking, CTDI measurement, ACR accreditation, ACR QC, and protocol review on Toshiba CT systems. Specific topics will include the following: Toshiba’s mechanism of tube current modulation; Exposure record format and interpretation of the values; Dose reporting and dose safeguard tools; Use of AIDR 3D iterative reconstruction; The configuration of task specific image quality target and its integration with AIDR 3D; Tips for scanning the ACR phantom with wide beam geometry; Measuring CTDI for wide beam geometry; Discussion of daily QC procedures and specifications; Tips for annual QC evaluation; Protocol management tools.

60 APPLIED LIFE SCIENCES↗

SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

Machine learning in a data-limited regime: Augmenting experiments with synthetic data uncovers order in crumpled sheets

Machine learning has gained widespread attention as a powerful tool to identify structure in complex, high-dimensional data. However, these techniques are ostensibly inapplicable for experimental systems where data are scarce or expensive to obtain. Here, we introduce a strategy to resolve this impasse by augmenting the experimental dataset with synthetically generated data of a much simpler sister system. Specifically, we study spontaneously emerging local order in crease networks of crumpled thin sheets, a paradigmatic example of spatial complexity, and show that machine learning techniques can be effective even in a data-limited regime. This is achieved by augmenting the scarce experimental dataset with inexhaustible amounts of simulated data of rigid flat-folded sheets, which are simple to simulate and share common statistical properties. This considerably improves the predictive power in a test problem of pattern completion and demonstrates the usefulness of machine learning in bench-top experiments where data are good but scarce.

97 MATHEMATICS AND COMPUTING↗

Methods for Probing Magnetic Films with Neutrons

We review various methods in the investigation of magnetic films with neutrons, including those based on the effects of Larmor precession, Zeeman spatial splitting of the beam, neutron spin resonance, and polarized neutron channeling. The underlying principles, examples of the investigated systems, specific features, applications, and perspectives of these methods are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of intercalated hydrogen on the electron state of quasi-free graphene on a SiC substrate

To judge the role of intercalated hydrogen in the doping of quasi-free epitaxial graphene, two systems, specifically, (i) the graphene–NH-SiC{0001} and (ii) graphene–hydrogen single layer–NH-SiC{0001} structures (N = 4, 6) are considered. In case (i), the shift of the Dirac point of epitaxial graphene is induced by the electrostatic potential of spontaneous polarization of the substrate; in case (ii), the shift is due to the field of a double electrical layer formed because of the absorption of hydrogen atoms. It is shown that, in case (ii) compared to case (i), the concentration of holes in graphene is higher and the concentration of electrons is lower. This result is consistent with the currently available experimental data.

36 MATERIALS SCIENCE↗

Design and analysis of CXL performance models for tightly-coupled heterogeneous computing

Truly heterogeneous systems enable partitioned workloads to be mapped to the hardware that nets the best performance. However, current practice requires that inter-device communication between different vendors' hardware use host memory as an intermediary step. To date, there are no widely adopted solutions that allow accelerators to directly transfer data. A new cache-coherent protocol, CXL, aims to facilitate easier, fine-grained sharing between accelerators. In this work we analyze existing methods for designing heterogeneous applications that target GPUs and FPGAs working collaboratively, followed by an exploration to show the benefits of a CXL-enabled system. Specifically, we develop a test application that utilizes both an NVIDIA P100 GPU and a Xilinx U250 FPGA to show current communication limitations. From this application, we capture overall execution time and throughput measurements on the FPGA and GPU. We use these measurements as inputs to novel CXL performance models to show that using CXL caching instead of host memory results in a 1.31X speedup, while a more tightly-coupled pipelined implementation using CXL-enabled hardware would result in a speedup of 1.45X.

Cabrera, Anthony↗

Optimized Data Transfers Based on the OpenCL Event Management Mechanism

In standard OpenCL programming, hosts are supposed to control their compute devices. Since compute devices are dedicated to kernel computation, only hosts can execute several kinds of data transfers such as internode communication and file access. These data transfers require one host to simultaneously play two or more roles due to the need for collaboration between the host and devices. The codes for such data transfers are likely to be system-specific, resulting in low portability. Here, this article proposes an OpenCL extension that incorporates such data transfers into the OpenCL event management mechanism. Unlike the current OpenCL standard, the main thread running on the host is not blocked to serialize dependent operations. Hence, an application can easily use the opportunities to overlap parallel activities of hosts and compute devices. In addition, the implementation details of data transfers are hidden behind the extension, and application programmers can use the optimized data transfers without any tricky programming techniques. The evaluation results show that the proposed extension can use the optimized data transfer implementation and thereby increase the sustained data transfer performance by about 18% for a real application accessing a big data file.

97 MATHEMATICS AND COMPUTING↗