Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

PHOTOMETRIC RESPONSE FUNCTIONS OF THE SLOAN DIGITAL SKY SURVEY IMAGER

The monochromatic illumination system is constructed to carry out in situ measurements of the response function of the mosaicked CCD imager used in the Sloan Digital Sky Survey (SDSS). The system is outlined and the results of the measurements, mostly during the first six years of the SDSS, are described. We present the reference response functions for the five color passbands derived from these measurements, and discuss column-to-column variations and variations in time, and also their effects on photometry. We also discuss the effect arising from various, slightly different response functions of the associated detector systems that were used to give SDSS photometry. We show that the calibration procedures of SDSS remove these variations reasonably well with the resulting final errors from variant response functions being unlikely to be larger than 0.01 mag for g, r, i, and z bands over the entire duration of the survey. The considerable aging effect is uncovered in the u band, the response function showing a 30% decrease in the throughput in the short wavelength side during the survey years, which potentially causes a systematic error in photometry. The aging effect is consistent with variation of the instrumental sensitivity in the u band, which is calibrated out. The expected color variation is consistent with measured color variation in the catalog of repeated photometry. The color variation is {delta}(u - g) {approx} 0.01 for most stars, and at most {delta}(u - g) {approx} 0.02 mag for those with extreme colors. We verified in the final catalog that no systematic variations in excess of 0.01 mag are detected in the photometry which can be ascribed to aging and/or seasonal effects except for the secular u - g color variation for stars with extreme colors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and correction of errors in nanoscale particle tracking using the Single-pixel interior filling function (SPIFF) algorithm

Particle tracking, which is an essential tool in many fields of scientific research, uses algorithms that retrieve the centroid of tracked particles with sub-pixel accuracy. However, images in which the particles occupy a small number of pixels on the detector, are in close proximity to other particles or suffer from background noise, show a systematic error in which the particle sub-pixel positions are biased towards the center of the pixel. This “pixel locking” effect greatly reduces particle tracking accuracy. In this report, we demonstrate the severity of these errors by tracking experimental (and simulated) imaging data of optically trapped silver nanoparticles and single fluorescent proteins. We show that errors in interparticle separation, angle and mean square displacement are significantly reduced by applying the corrective Single-Pixel Interior Filling Function (SPIFF) algorithm. Our work demonstrates the potential ubiquity of such errors and the general applicability of SPIFF correction to many experimental fields.

Science & Technology - Other Topics↗

The Stability of Fiber Spectrographs in the Faint-source Regime

The use of optical fibers in astronomical instrumentation offers high-multiplex and light-gathering flexibility. However, with most previous fiber spectrographs optimized for large fields of view on modest-aperture telescopes, the performance of fibers in the context of faint targets on large telescopes remains largely untested. In this paper, we evaluate aspects of fiber stability, especially as they apply in the context of precision sky subtraction of faint sources at modest spectral resolution ($R$ ~ 3000). After introducing a framework for describing potential systematic errors, we use publicly available data from existing instruments, including instrumentation used by the fourth-generation Sloan Digital Sky Survey’s MaNGA project (MaNGA: Mapping Nearby Galaxies at Apache Point Observatory) and the Very Large Telescope’s FLAMES: Fiber Large Array Multi Element Spectrograph. We isolate sources of fiber systematics and estimate the observed amplitude of persistent residuals as well as stochastic noise contributions resulting from changing fiber stresses. Comparing these levels against their impact on various sky subtraction schemes demonstrates that 0.1% precision sky subtraction with fiber instruments is possible. As a demonstration, we show that the MaNGA instrument can deliver 0.2% residuals on bright near-IR sky lines with nonlocal sky subtraction, if pseudo-slit limitations are addressed by allocating 50% of its fibers to sky. We further highlight recently published deep exposures that achieved a 1$σ$ background level of 27.6 AB per square arc second, equivalent to a precision of 0.2% of the sky background continuum.

79 ASTRONOMY AND ASTROPHYSICS↗

Image-Guided Radiotherapy for Breast Cancer Patients: Surgical Clips as Surrogate for Breast Excision Cavity

Purpose: To determine the use of surgical clips as a surrogate for localization of the excision cavity and to quantify the stability of the clips' positions during the course of external beam radiotherapy for breast cancer patients, using cone beam computed tomography (CBCT) scans. Methods and Materials: Twenty-one breast cancer patients with surgical clips placed in the breast excision cavity were treated in a supine position with 28 daily fractions. CBCT scans were regularly acquired for a setup correction protocol. Retrospectively, the CBCT scans were registered to the planning CT scans, using gray-value registration of the excision cavity region and chamfer matching of the clips. Subsequently, residual setup errors (systematic [{Sigma}] and random [{sigma}]) of the excision cavity were estimated relative to the clips' registration. Finally, the stability of the clips' positions were quantified as the movement of each separate clip according to the center of gravity of the excision cavity. Results: When clips were used for online setup corrections, the residual errors of the excision cavity were {Sigma}{sub left-right} = 1.2, {sigma}{sub left-right} = 1.0; {Sigma}{sub cranial-caudal} = 1.3, {sigma}{sub cranial-caudal} = 1.2; and {Sigma}{sub anterior-posterior} = 0.7, {sigma}{sub anterior-posterior} = 0.9 mm. Furthermore, the average distance (over all patients) between the clips and centers of gravity of the excision cavities was 18.8 mm (on the planning CT) and was reduced to 17.4 mm (measured on the last CBCT scan). Conclusion: Clips move in the direction of the center of gravity of the excision cavity, on average, 1.4 mm. The clips are good surrogates for locating the excision cavity and providing small residual errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A global potential energy surface and dipole moment surface for silane

A new nine-dimensional potential energy surface (PES) and dipole moment surface (DMS) for silane have been generated using high-level ab initio theory. The PES, CBS-F12{sup HL}, reproduces all four fundamental term values for {sup 28}SiH{sub 4} with sub-wavenumber accuracy, resulting in an overall root-mean-square error of 0.63 cm{sup −1}. The PES is based on explicitly correlated coupled cluster calculations with extrapolation to the complete basis set limit, and incorporates a range of higher-level additive energy corrections to account for core-valence electron correlation, higher-order coupled cluster terms, and scalar relativistic effects. Systematic errors in computed intra-band rotational energy levels are reduced by empirically refining the equilibrium geometry. The resultant Si–H bond length is in excellent agreement with previous experimental and theoretical values. Vibrational transition moments, absolute line intensities of the ν{sub 3} band, and the infrared spectrum for {sup 28}SiH{sub 4} including states up to J = 20 and vibrational band origins up to 5000 cm{sup −1} are calculated and compared with available experimental results. The DMS tends to marginally overestimate the strength of line intensities. Despite this, band shape and structure across the spectrum are well reproduced and show good agreement with experiment. We thus recommend the PES and DMS for future use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of eta_c(1S) and eta_c(2S) decays to K K-pi pi-pi0 in two-photon interactions

We study the processes {gamma}{gamma} {yields} K{sub S}{sup 0}K{sup {+-}}{pi}{sup {-+}} and {gamma}{gamma} {yields} K{sup +}K{sup -}{pi}{sup +}{pi}{sup -}{pi}{sup 0} using a data sample of 519.2 fb{sup -1} recorded by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at center-of-mass energies near the {Upsilon}(nS) (n = 2, 3, 4) resonances. We observe the {eta}{sub c}(1S), {chi}{sub c0}(1P), {chi}{sub c2}(1P), and {eta}{sub c}(2S) resonances produced in two-photon interactions and decaying to K{sup +}K{sup -}{pi}{sup +}{pi}{sup -}{pi}{sup 0}, with significances of 18.1, 5.7, 5.2, and 5.3 standard deviations (including systematic errors), respectively. We measure the {eta}{sub c}(2S) mass and width in K{sub S}{sup 0}K{sup {+-}}{pi}{sup {-+}} decays, m({eta}{sub c}(2S)) = 3638.5 {+-} 1.5 {+-} 0.8 MeV/c{sup 2} and {Lambda}({eta}{sub c}(2S)) = 13.4 {+-} 4.6 {+-} 3.2 MeV, where the first uncertainty is statistical and the second is systematic. We search for the Z(3930) resonance and find no significant signal. We also provide the two-photon width times branching fraction values for the observed resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-13: Six Degree of Freedom Image Fusion Accuracy for Cranial Target Localization On the Varian Edge Stereotactic Radiosurgery System: Comparison Between 2D/3D and KV CBCT Image Registration

Purpose: To determine the 6 degree of freedom systematic deviations between 2D/3D and CBCT image registration with various imaging setups and fusion algorithms on the Varian Edge Linac. Methods: An anthropomorphic head phantom with radio opaque targets embedded was scanned with CT slice thicknesses of 0.8, 1, 2, and 3mm. The 6 DOF systematic errors were assessed by comparing 2D/3D (kV/MV with CT) with 3D/3D (CBCT with CT) image registrations with different offset positions, similarity measures, image filters, and CBCT slice thicknesses (1 and 2 mm). The 2D/3D registration accuracy of 51 fractions for 26 cranial SRS patients was also evaluated by analyzing 2D/3D pre-treatment verification taken after 3D/3D image registrations. Results: The systematic deviations of 2D/3D image registration using kV- kV, MV-kV and MV-MV image pairs were within ±0.3mm and ±0.3° for translations and rotations with 95% confidence interval (CI) for a reference CT with 0.8 mm slice thickness. No significant difference (P>0.05) on target localization was observed between 0.8mm, 1mm, and 2mm CT slice thicknesses with CBCT slice thicknesses of 1mm and 2mm. With 3mm CT slice thickness, both 2D/3D and 3D/3D registrations performed less accurately in longitudinal direction than thinner CT slice thickness (0.60±0.12mm and 0.63±0.07mm off, respectively). Using content filter and using similarity measure of pattern intensity instead of mutual information, improved the 2D/3D registration accuracy significantly (P=0.02 and P=0.01, respectively). For the patient study, means and standard deviations of residual errors were 0.09±0.32mm, −0.22±0.51mm and −0.07±0.32mm in VRT, LNG and LAT directions, respectively, and 0.12°±0.46°, −0.12°±0.39° and 0.06°±0.28° in RTN, PITCH, and ROLL directions, respectively. 95% CI of translational and rotational deviations were comparable to those in phantom study. Conclusion: 2D/3D image registration provided on the Varian Edge radiosurgery, 6 DOF-based system provides accurate target positioning for frameless image-guided cranial stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

Measuring Interfractional and Intrafractional Motion With Cone Beam Computed Tomography and an Optical Localization System for Lower Extremity Soft Tissue Sarcoma Patients Treated With Preoperative Intensity-Modulated Radiation Therapy

Purpose: To evaluate inter- and intrafractional motion and rotational error for lower extremity soft tissue sarcoma patients by using cone beam computed tomography (CBCT) and an optical localization system. Methods and Materials: Thirty-one immobilized patients received CBCT image-guided intensity-modulated radiation therapy. Setup deviations of >3 mm from the planned isocenter were corrected. A second CBCT acquired before treatment delivery was registered to the planning CT to estimate interfractional setup error retrospectively. Interfractional error and rotational error were calculated in the left-right (LR), superoinferior (SI), and anteroposterior (AP) dimensions. Intrafractional motion was assessed by calculating the maximum relative displacement of optical localization system reflective markers placed on the patient's surface, combined with pre- and postfraction CBCT performed for 17 of the 31 patients once per week. The overall systematic error (SE) and random error (RE) were calculated for the interfractional and intrafractional motion for planning target volume margin calculation. Results: The standard deviation (SD) of the interfractional RE was 1.9 mm LR, 2.1 mm SI, and 1.8 mm AP, and the SE SD was 0.6 mm, 1.2 mm, and 0.7 mm in each dimension, respectively. The overall rotation (inter- and intrafractional) had an RE SD of 0.8{sup o} LR, 1.7{sup o} SI, and 0.7{sup o} AP and an SE SD of 1.1{sup o} LR, 1.3{sup o} SI, and 0.3{sup o} AP. The SD of the overall intrafractional RE was 1.6 mm LR, 1.6 mm SI, and 1.4 mm AP, and the SE SD was 0.7 mm AP, 0.6 mm SI, and 0.6 mm AP. Conclusions: A uniform 5-mm planning target volume margin was quantified for lower extremity soft tissue sarcoma patients and has been implemented clinically for image-guided intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 3% SOLUTION: DETERMINATION OF THE HUBBLE CONSTANT WITH THE HUBBLE SPACE TELESCOPE AND WIDE FIELD CAMERA 3

We use the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST) to determine the Hubble constant from optical and infrared observations of over 600 Cepheid variables in the host galaxies of eight recent Type Ia supernovae (SNe Ia), providing the calibration for a magnitude-redshift relation based on 253 SNe Ia. Increased precision over past measurements of the Hubble constant comes from five improvements: (1) more than doubling the number of infrared observations of Cepheids in the nearby SN hosts; (2) increasing the sample size of ideal SN Ia calibrators from six to eight; (3) increasing by 20% the number of Cepheids with infrared observations in the megamaser host NGC 4258; (4) reducing the difference in the mean metallicity of the Cepheid comparison samples between NGC 4258 and the SN hosts from {Delta}log [O/H] = 0.08 to 0.05; and (5) calibrating all optical Cepheid colors with a single camera, WFC3, to remove cross-instrument zero-point errors. The result is a reduction in the uncertainty in H{sub 0} due to steps beyond the first rung of the distance ladder from 3.5% to 2.3%. The measurement of H{sub 0} via the geometric distance to NGC 4258 is 74.8 {+-} 3.1 km s{sup -1} Mpc{sup -1}, a 4.1% measurement including systematic uncertainties. Better precision independent of the distance to NGC 4258 comes from the use of two alternative Cepheid absolute calibrations: (1) 13 Milky Way Cepheids with trigonometric parallaxes measured with HST/fine guidance sensor and Hipparcos and (2) 92 Cepheids in the Large Magellanic Cloud for which multiple accurate and precise eclipsing binary distances are available, yielding 74.4 {+-} 2.5 km s{sup -1} Mpc{sup -1}, a 3.4% uncertainty including systematics. Our best estimate uses all three calibrations but a larger uncertainty afforded from any two: H{sub 0} = 73.8 {+-} 2.4 km s{sup -1} Mpc{sup -1} including systematic errors, corresponding to a 3.3% uncertainty. The improved measurement of H{sub 0}, when combined with the Wilkinson Microwave Anisotropy Probe (WMAP) 7 year data, results in a tighter constraint on the equation-of-state parameter of dark energy of w = -1.08 {+-} 0.10. It also rules out the best-fitting gigaparsec-scale void models, posited as an alternative to dark energy. The combined H{sub 0} + WMAP results yield N{sub eff} = 4.2 {+-} 0.7 for the number of relativistic particle species in the early universe, a low-significance excess for the value expected from the three known neutrino flavors.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing Impacts of Waves on Hub-Height Winds off the U.S. West Coast Using Lidar Buoys and Coupled Modeling Approaches

Given the importance of offshore wind energy development to the U.S. clean energy targets, it is vital to be able to characterize the wind resource in that environment accurately. Toward that end, two Bureau of Ocean Energy Management buoys equipped with Doppler lidar are being maintained by Pacific Northwest National Laboratory on behalf of the Department of Energy and deployed to regions of potential offshore wind development. In addition to standard meteorological and oceanographic measurements, the buoys document the wind profile between about 40 m and 250 m above the sea surface through Doppler lidar retrievals. After a multiyear deployment of two buoys along the U.S. East Coast, the buoys were redeployed to the U.S. West coast from 2020 – 2022 to locations near the Humboldt and Morro Bay lease areas. The buoys provide nearly continuous, multiyear datasets that can be used to evaluate predictions of hub-height (~100 m) wind speed for standard atmospheric models in the region. In the absence of measurements at the study site, offshore wind developers rely on model-based data to assess site conditions. Potential sources of model error in this environment include under-resolution or misrepresentation of coastal topographically forced flows, marine boundary layer dynamics and the evolution of their associated cloud and turbulence fields, the role of upwelling and other currents on surface heat fluxes into the boundary layer, and the impact of wave fields on surface momentum fluxes and thus the wind speed profile. In particular, most predictive models of wind speed do not predict wave fields at all, relying on parameterizations to represent their effects. In thus study, we focus on evaluating the role of wind / wave interactions on modeled hub-height wind speed and error by using the Coupled Ocean–Atmosphere–Wave–Sediment–Transport Modeling System to capture two-way interactions between an atmospheric model (Weather Research and Forecasting (WRF)) and a wave model (WAVEWATCHIII (WW3)) and compare to both stand-alone WRF and one-way coupled WRF / WW3 configurations. Our approach is similar to that used in Gaudet et al. (2022) to evaluate wind / wave coupling over the U.S. East Coast, but applied to the very different environment of the U.S. West Coast. We show examples for two cases, a cold-season frontal case and a warm-season low-level jet case. We find that wind / wave coupling makes little impact on model error for these cases at the location of the lidar buoys, for which other misrepresentations of model physics seems to be responsible for model-observation discrepancies. However, domain-wide evaluations, which also make use of the National Buoy Data Center network, show that a two-way coupling approach is less prone to systematic errors in the hub-height wind field than the one-way coupled approach. WRF resolution of kilometer-scale or less is needed to properly capture the sharp wind speed gradients that can be found along the coastline, and WW3 simulations driven by the downscaled WRF produce better bulk and spectral wave fields when compared to observations. Implications of the results for wind resource characterization are then discussed.

17 WIND ENERGY↗

A Device and Procedure for Immobilization of Patients Receiving Limb-Preserving Radiotherapy for Soft Tissue Sarcoma

The purpose of this study was to determine the accuracy and efficiency of a custom-designed immobilization device for patients with extremity soft-tissue sarcoma. The custom device consisted of a thermoplastic shell, vacuum pillow, and adaptable baseplate. The study included patients treated from January 2005 to March 2007, with 92 patients immobilized with the custom device and 98 with an established standard. Setup times for these cohorts were analyzed retrospectively for conformal and intensity modulated radiotherapy techniques (IMRT). Thigh tumor setup times were analyzed independently. A subset of patients treated with IMRT was analyzed for setup error using the radiographically verified isocenter position measured daily with electronic portal imaging and cone-beam computed tomography. Mean setup time was reduced by 2.2 minutes when using the custom device for conformal treatment (p = 0.03) and by 5.8 min for IMRT of thigh tumors (p = 0.009). All other setup time comparisons were not significant. A significant systematic error reduction was seen in all directions using the custom device. Random error standard deviations favored the custom device. The custom device offers immobilization advantages. Patient setup time was reduced for conformal techniques and IMRT of thigh tumors. Positioning uncertainty was improved, permitting a reduction of the planning target volume margin by 2 to 4 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Acoustic time-of-flight for proton range verification in water

Purpose: Measurement of the arrival times of thermoacoustic waves induced by pulsed proton dose depositions (protoacoustics) may provide a proton range verification method. The goal of this study is to characterize the required dose and protoacoustic proton range (distance) verification accuracy in a homogeneous water medium at a hospital-based clinical cyclotron. Methods: Gaussian-like proton pulses with 17 μs widths and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 3.4 cGy/pulse at the Bragg peak) were generated by modulating the cyclotron proton source with a function generator. After energy degradation, the 190 MeV proton pulses irradiated a water phantom, and the generated protoacoustic emissions were measured by a hydrophone. The detector position and proton pulse characteristics were varied. The experimental results were compared to simulations. Different arrival time metrics derived from acoustic waveforms were compared, and the accuracy of protoacoustic time-of-flight distance calculations was assessed. Results: A 27 mPa noise level was observed in the treatment room during irradiation. At 5 cm from the proton beam, an average maximum pressure of 5.2 mPa/1 × 10{sup 7} protons (6.1 mGy at the Bragg peak) was measured after irradiation with a proton pulse with 10%–90% rise time of 11 μs. Simulation and experiment arrival times agreed well, and the observed 2.4 μs delay between simulation and experiment is attributed to the difference between the hydrophone’s acoustic and geometric centers. Based on protoacoustic arrival times, the beam axis position was measured to within (x, y) = (−2.0, 0.5) ± 1 mm. After deconvolution of the exciting proton pulse, the protoacoustic compression peak provided the most consistent measure of the distance to the Bragg peak, with an error distribution with mean = − 4.5 mm and standard deviation = 2.0 mm. Conclusions: Based on water tank measurements at a clinical hospital-based cyclotron, protoacoustics is a potential method for measuring the beam’s position (x and y within 2.0 mm) and Bragg peak range (2.0 mm standard deviation), although range verification will require simulation or experimental calibration to remove systematic error. Based on extrapolation, a protoacoustic arrival time reproducibility of 1.5 μs (2.2 mm) is achievable with 2 Gy of total deposited dose. Of the compared methods, deconvolution of the excitation proton pulse is the best technique for extracting protoacoustic arrival times, particularly if there is variation in the proton pulse shape.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement Uncertainty of Highly Asymmetrically Curved Elliptical Mirrors Using Multi-Pitch Slope Stitching Technique

Soft X-ray off-axis elliptical mirrors bring new challenges for X-ray mirror metrology. These highly asymmetrically curved elliptical cylindrical mirrors with a total slope range >10 mrad are extremely challenging to measure. Their total slope range exceeds the measuring range of most angular sensors used for X-ray mirror inspection. To overcome this problem, it is possible to stitch partial slope data by measuring the mirror at different pitch angles (multi-pitch angles). By revisiting the theory of the multi-pitch Nano-accuracy Surface Profiler (NSP), we derive the sampling position error on the mirror surface as a function of the mirror height profile and the measurement error of the pitch rotation center. When measuring “extreme”, highly asymmetrically curved, elliptical mirrors, the calculation of the mirror height profile with iterative reconstruction outperforms the classical “flat assumption” (i.e., assuming that the mirror sag is negligible). As demonstrated by our simulations, a proper tolerance evaluation on the measurement of pitch rotation center is needed to assess the measurement accuracy (systematic error) for these strongly aspherical mirrors using the multi-pitch NSP technique. Taking a real design of an “extreme” elliptical mirror as a case study, we conduct a Monte Carlo simulation to mimic the measurement and characterization process to analyze the impact of several error sources. With the measurement uncertainty of the pitch rotation center, the multi-pitch NSP measurement can estimate the grazing angle θ and the chief ray location x o with their uncertainties, as well as the slope residuals.

36 MATERIALS SCIENCE↗

Magnitude of speed of sound aberration corrections for ultrasound image guided radiotherapy for prostate and other anatomical sites

Purpose: The purpose of this work is to assess the magnitude of speed of sound (SOS) aberrations in three-dimensional ultrasound (US) imaging systems in image guided radiotherapy. The discrepancy between the fixed SOS value of 1540 m/s assumed by US systems in human soft tissues and its actual nonhomogeneous distribution in patients produces small but systematic errors of up to a few millimeters in the positions of scanned structures. Methods: A correction, provided by a previously published density-based algorithm, was applied to a set of five prostate, five liver, and five breast cancer patients. The shifts of the centroids of target structures and the change in shape were evaluated. Results: After the correction the prostate cases showed shifts up to 3.6 mm toward the US probe, which may explain largely the reported positioning discrepancies in the literature on US systems versus other imaging modalities. Liver cases showed the largest changes in volume of the organ, up to almost 9%, and shifts of the centroids up to more than 6 mm either away or toward the US probe. Breast images showed systematic small shifts of the centroids toward the US probe with a maximum magnitude of 1.3 mm. Conclusions: The applied correction in prostate and liver cancer patients shows positioning errors of several mm due to SOS aberration; the errors are smaller in breast cancer cases, but possibly becoming more important when breast tissue thickness increases.

60 APPLIED LIFE SCIENCES↗

Measuring neutrino oscillation parameters using $\nu_\mu$ disappearance in MINOS

MINOS is a long-baseline neutrino oscillation experiment. It consists of two large steel-scintillator tracking calorimeters. The near detector is situated at Fermilab, close to the production point of the NuMI muon-neutrino beam. The far detector is 735 km away, 716m underground in the Soudan mine, Northern Minnesota. The primary purpose of the MINOS experiment is to make precise measurements of the 'atmospheric' neutrino oscillation parameters (Δm atm 2 and sin 2 2θ atm ). The oscillation signal consists of an energy-dependent deficit of v μ interactions in the far detector. The near detector is used to characterize the properties of the beam before oscillations develop. The two-detector design allows many potential sources of systematic error in the far detector to be mitigated by the near detector observations. This thesis describes the details of the v μ -disappearance analysis, and presents a new technique to estimate the hadronic energy of neutrino interactions. This estimator achieves a significant improvement in the energy resolution of the neutrino spectrum, and in the sensitivity of the neutrino oscillation fit. The systematic uncertainty on the hadronic energy scale was re-evaluated and found to be comparable to that of the energy estimator previously in use. The best-fit oscillation parameters of the v μ -disappearance analysis, incorporating this new estimator were: Δm 2 = 2.32 -0.08 +0.12 x 10 -3 eV 2 , sin 2 2θ > 0.90 (90% C.L.). A similar analysis, using data from a period of running where the NuMI beam was operated in a configuration producing a predominantly $\bar{v}$ μ beam, yielded somewhat different best-fit parameters Δ$\bar{m}${sup 2} = (3.36 -0.40 +0.46 (stat.) ± 0.06(syst.)) x 10 -3 eV 2 , sin 2 2$\bar{θ}$ = 0.86 -0.12 _0.11 (stat.) ± 0.01(syst.). The tension between these results is intriguing, and additional antineutrino data is currently being taken in order to further investigate this apparent discrepancy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-H-BRC-08: Examining Credentialing Criteria and Poor Performance Indicators for IROC Houston’s Anthropomorphic Head and Neck Phantom

Purpose: To analyze the most recent results of IROC Houston’s anthropomorphic H&N phantom to determine the nature of failing irradiations and the feasibility of altering pass/fail credentialing criteria. Methods: IROC Houston’s H&N phantom, used for IMRT credentialing for NCI-sponsored clinical trials, requires that an institution’s treatment plan must agree with measurement within 7% (TLD doses) and ≥85% pixels must pass 7%/4 mm gamma analysis. 156 phantom irradiations (November 2014 – October 2015) were re-evaluated using tighter criteria: 1) 5% TLD and 5%/4 mm, 2) 5% TLD and 5%/3 mm, 3) 4% TLD and 4%/4 mm, and 4) 3% TLD and 3%/3 mm. Failure/poor performance rates were evaluated with respect to individual film and TLD performance by location in the phantom. Overall poor phantom results were characterized qualitatively as systematic (dosimetric) errors, setup errors/positional shifts, global but non-systematic errors, and errors affecting only a local region. Results: The pass rate for these phantoms using current criteria is 90%. Substituting criteria 1-4 reduces the overall pass rate to 77%, 70%, 63%, and 37%, respectively. Statistical analyses indicated the probability of noise-induced TLD failure at the 5% criterion was <0.5%. Using criteria 1, TLD results were most often the cause of failure (86% failed TLD while 61% failed film), with most failures identified in the primary PTV (77% cases). Other criteria posed similar results. Irradiations that failed from film only were overwhelmingly associated with phantom shifts/setup errors (≥80% cases). Results failing criteria 1 were primarily diagnosed as systematic: 58% of cases. 11% were setup/positioning errors, 8% were global non-systematic errors, and 22% were local errors. Conclusion: This study demonstrates that 5% TLD and 5%/4 mm gamma criteria may be both practically and theoretically achievable. Further work is necessary to diagnose and resolve dosimetric inaccuracy in these trials, particularly for systematic dose errors. This work is funded by NCI Grant CA180803.

60 APPLIED LIFE SCIENCES↗

Minimizing Grating Slope Errors in the IEX Monochromato at the Advanced Photon Source

The IEX beamline at the APS is currently in the commissioning phase. The energy resolution of the beamline was not meeting original specifications by several orders of magnitude. The monochromator, an in-focus VLS-PGM, is currently configured with a high and a medium-line-density grating. Experimental results indicated that both gratings were contributing to the poor energy resolution and this led to venting the monochromator to investigate. The initial suspicion was that a systematic error had occurred in the ruling process on the VLS gratings, but that proved to not be the case. Instead the problem was isolated to mechanical constraints used to mount the gratings into their respective side-cooled holders. Modifications were made to the holders to eliminate problematic constraints without compromising the rest of the design. Metrology performed on the gratings in the original and modified holders demonstrated a 20-fold improvement in the surface profile error which was consistent with finite element analysis performed in support of the modifications. Two gratings were successfully reinstalled and subsequent measurements with beam show a dramatic improvement in energy resolution.

Fisher, M. V.↗

A 5 per cent measurement of the Hubble–Lemaître constant from Type II supernovae

ABSTRACT The most stringent local measurement of the Hubble–Lemaître constant from Cepheid-calibrated Type Ia supernovae (SNe Ia) differs from the value inferred via the cosmic microwave background radiation (Planck+ΛCDM) by ∼5σ. This so-called Hubble tension has been confirmed by other independent methods, and thus does not appear to be a possible consequence of systematic errors. Here, we continue upon our prior work of using Type II supernovae to provide another, largely independent method to measure the Hubble–Lemaître constant. From 13 SNe II with geometric, Cepheid, or tip of the red giant branch (TRGB) host-galaxy distance measurements, we derive H$_0= 75.4^{+3.8}_{-3.7}$ km s−1 Mpc−1 (statistical errors only), consistent with the local measurement but in disagreement by ∼2.0σ with the Planck+ΛCDM value. Using only Cepheids (N = 7), we find H$_0 = 77.6^{+5.2}_{-4.8}$ km s−1 Mpc−1, while using only TRGB (N = 5), we derive H$_0 = 73.1^{+5.7}_{-5.3}$ km s−1 Mpc−1. Via 13 variants of our data set, we derive a systematic uncertainty estimate of 1.5 km s−1 Mpc−1. The median value derived from these variants differs by just 0.3 km s−1 Mpc−1 from that produced by our fiducial model. Because we only replace SNe Ia with SNe II – and we do not find statistically significant difference between the Cepheid and TRGB H0 measurements – our work reveals no indication that SNe Ia or Cepheids could be the sources of the ‘H0 tension.’ We caution, however, that our conclusions rest upon a modest calibrator sample; as this sample grows in the future, our results should be verified.

79 ASTRONOMY AND ASTROPHYSICS↗