Additive Manufacturing of Thermal Protection Systems (AMTPS)

Heat shield manufacturing has changed little in the last 60 years. State of the art designs utilize tiled, or block, configurations fabricated in segments and individually bonded to the vehicle structure. Gaps between blocks are then filled. These processes are hands on, labor intensive, and involve long lead times.

Thermal protection systems↗

Conformal Ablative Thermal Protection Systems (CA-TPS) for Venus and Saturn Backshells

This poster provides an overview of the work performed to date on the Conformal Ablative TPS (CA-TPS) element of the TPSM project out of GCDP. Under this element, NASA is developing improved ablative TPS materials based on flexible felt for reinforcement rather than rigid reinforcements. By replacing the reinforcements with felt, the resulting materials have much higher strain-to-failure and are much lower in thermal conductivity than their rigid counterparts. These characteristics should allow for larger tile sizes, direct bonding to aeroshells and even lower weight TPS. The conformal phenolic impregnated carbon felt (C-PICA) is a candidate for backshell TPS for both Venus and Saturn entry vehicles.

Saturn↗

Thermal protection systems for equipment pallets to be launched in Shuttle Orbiter

The thermal insulation for the OSS-1 Orbiter pallet is described and a design concept for future pallets is presented consisting of two independent thermal zones and new thermal insulation approaches. The application of these concepts is expected to reduce the effort required to integrate the payloads to their pallets and thereby reduce dollar costs and shorten time schedules. A stand-off insulation also is described for certain pallet areas to enclose the cabling and fluid lines in a controlled temperature environment. Methods for interfacing the payload and pallet insulations are presented and a number of areas are identified where the introduction of standards in the fabrication of thermal insulation can yield further savings.

Ruccia, F. E.↗

Conformal Ablative Thermal Protection Systems (CA-TPS) for Venus and Saturn Backshells

The new conformal ablator C-PICA, which was developed under STMD GCD, is an optimal candidate for use on the backshells for high velocity entry vehicles at both Venus and Saturn. The material has been tested at heat fluxes up to 400 Wcm2 in shear and over 1800 Wcm2 and 1.5 atm in stagnation with good results. C-PICA has similar density to PICA, but shows half the thermal penetration and similar recession at the same conditions, allowing for a lighter weight TPS to be flown. This poster for VEXAG will show the progress made in the development of the material and why it should be considered for use.

Conformal Ablative↗

High temperature insulation materials for reradiative thermal protection systems

Results are presented of a two year program to evaluate packaged thermal insulations for use under a metallic radiative TPS of a shuttle orbiter vehicle. Evaluations demonstrated their survival for up to 100 mission reuse cycles under shuttle acoustic and thermal loads with peak temperatures of 1000 F, 1800 F, 2000 F, 2200 F and 2500 F. The specimens were composed of low density refractory fiber felts, packaged in thin gage metal foils. In addition, studies were conducted on the venting requirements of the packages, salt spray resistance of the metal foils, and the thermal conductivity of many of the insulations as a function of temperature and ambient air pressure. Data is also presented on the radiant energy transport through insulations, and back-scattering coefficients were experimentally determined as a function of source temperature.

Hughes, T. A.↗

An Update to a Conformal Ablative Thermal Protection System for Planetary and Human Exploration Missions

As described at IPPW-10, in FY12, the CA-TPS element focused on establishing materials requirements based on MSL-type and COTS Low Earth orbit (LEO) conditions (q 250 Wcm2) to develop and deliver a conformal ablative TPS. This involved down selecting, manufacturing and testing two of the best candidate materials, demonstrating uniform infiltration of resins into baseline 2-cm thick carbon felt, selecting a primary conformal material formulation based on novel arc jet and basic material properties testing, developing and demonstrating instrumentation for felt-based materials and, based on the data, developing a low fidelity material response model so that the conformal ablator TPS thickness for missions could be established. In addition, the project began to develop Industry Partnerships. Since the nominal thickness of baseline carbon felts was only 2-cm, a partnership with a rayon felt developer was made in order to upgrade equipment, establish the processes required and attempt to manufacture 10-cm thick white goods. A partnership with a processing house was made to develop the methodology to carbonize large pieces of the white goods into 7.5-cm thick carbon felt. In FY13, more advanced testing and modeling of the down selected conformal material was performed. Material thermal properties tests and structural properties tests were performed. The first 3 and 4-point bend tests were performed on the conformal ablator as well as PICA for comparison and the conformal ablator had outstanding behavior compared to PICA. Arc jet testing was performed with instrumented samples of both the conformal ablator and standard PICA at heating rates ranging from 40 to 400 Wcm2 and shear as high as 600 Pa. The results from these tests showed a remarkable improvement in the thermal penetration through the conformal ablator when compared to PICAs response. The data from these tests were used to develop a mid-fidelity thermal response model. Additional arc jet testing in the same conditions on various seam designs were very successful in showing that the material could be joined with a minimum of adhesive and required no complicated gap and gap filler design for installation. In addition, the partnership with industry to manufacture thicker rayon felt was very successful. The vendor made a 2-m wide by 30-m long sample of 10-cm thick rayon felt. When carbonized, the resulting thickness was over 7.5-cm thick, nearly 4 times the thickest off-the-shelf carbon felt. In FY14, the project has initiated a partnership with another vendor to begin the scale-up manufacturing effort. This year, the vendor will duplicate the process and manufacture at the current scale for comparison with NASA-processed materials. Properties testing and arc jet testing will be performed on the vendor-processed materials. Planning for manufacturing large, 1-m x 1-m, panels will begin as well. In FY15, the vendor will then manufacture large panels and the project will build a 2-m x 2-m Manufacturing Demonstration Unit (MDU).

Ablative materials↗

Conformal Ablative Thermal Protection System for Planetary and Human Exploration Missions: An Update of the Technology Maturation Effort

This presentation will update the community on the development of conformal ablative TPS. As described at IPPW-10, in FY12, the CA-TPS element focused on establishing materials requirements based on MSL-type and COTS Low Earth orbit (LEO) conditions (q 250 Wcm2) to develop and deliver a conformal ablative TPS. This involved downselecting, manufacturing and testing two of the best candidate materials, demonstrating uniform infiltration of resins into baseline 2-cm thick carbon felt, selecting a primary conformal material formulation based on novel arc jet and basic material properties testing, developing and demonstrating instrumentation for felt-based materials and, based on the data, developing a low fidelity material response model so that the conformal ablator TPS thickness for missions could be established. In addition, the project began to develop Industry Partnerships. Since the nominal thickness of baseline carbon felts was only 2-cm, a partnership with a rayon felt developer was made in order to upgrade equipment, establish the processes required and attempt to manufacture 10-cm thick white goods. A partnership with a processing house was made to develop the methodology to carbonize large pieces of the white goods into 7.5-cm thick carbon felt.In FY13, more advanced testing and modeling of the downselected conformal material was performed. Material thermal properties tests and structural properties tests were performed. The first 3 and 4-point bend tests were performed on the conformal ablator as well as PICA for comparison and the conformal ablator had outstanding behavior compared to PICA. Arc jet testing was performed with instrumented samples of both the conformal ablator and standard PICA at heating rates ranging from 40 to 400 Wcm2 and shear as high as 600 Pa. The results from these tests showed a remarkable improvement in the thermal penetration through the conformal ablator when compared to PICAs response. The data from these tests were used to develop a mid-fidelity thermal response model. Additional arc jet testing in the same conditions on various seam designs were very successful in showing that the material could be joined with a minimum of adhesive and required no complicated gap and gap filler design for installation. In addition, the partnership with industry to manufacture thicker rayon felt was very successful. The vendor made a 2-m wide by 30-m long sample of 10-cm thick rayon felt. When carbonized, the resulting thickness was over 7.5-cm thick, nearly 4 times the thickest off-the-shelf carbon felt. In FY14, the project has initiated a partnership with another vendor to begin the scale-up manufacturing effort. This year, the vendor will duplicate the process and manufacture at the current scale for comparison with NASA-processed materials. Properties testing and arc jet testing will be performed on the vendor-processed materials. Planning for manufacturing large, 1-m x 1-m, panels will begin as well. In FY15, the vendor will then manufacture large panels and the project will build a 2-m x 2-m Manufacturing Demonstration Unit (MDU).

thermal protection systems↗

Flexure support system protects thermally and dynamically loaded models

The design of an eight legged flexure support system which permits differential thermal expansion of thin skinned models subjected to high temperatures is done by setting the lengthwise axes of the supporting legs approximately normal to the line of absolute motion of the model supported.

Crumpler, W. B.↗

Error Sources and Mitigation Strategies for Thermocouples Integrated in Flexible Thermal Protection System Materials

Brief Presenter Biography:Ruth Miller is an aer-ospace systems engineer in the Entry Systems and Ve-hicle Development Branch at NASA Ames Research Center.Introduction:The flexible thermal protection sys-tem (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle will be in-strumented with thermocouples (TCs) to measure the in-depth thermal response during entry into Earth’s atmos-phere[1, 2]. Accurate flight temperature measurements are critical for verifying vehicle performance during the flight test and reducing uncertainties in the thermal models.However,the deployable nature of inflatable decelerator technology presents challengesfor integrat-ing TCs, specifically the TCsneed to be compactableand cannot damage the FTPSnor the inflatable structure(IS).Unlike traditional rigid aeroshells, routing TCsthrough the thickness of the FTPS could cause signifi-cant damage during packing of the deployable aeroshellbecause the different layers may shift small amounts in relation to each other imparting strain on the TCsand FTPS materials. The LOFTID TCleads are routed from the measurement location back to the data acquisition system in the vehicle centerbody within the same FTPS layer that they are monitoring the temperature. This ap-proach eliminates the need to put holes in the FTPS lay-ers,butas a consequence,the insulated TCleads travel for an appreciable distance through a region that will expose them to high temperaturesand large thermal gra-dients.LOFTID’s TCswere baselined to be commercially available Type K TCswith a binder impregnated glass braid insulation. These TCswere chosen because they had been used successfully on IRVE-3 and in ground-based arc jet testing. Additionally, these TCsdid notdamage the FTPS nor IS during packing and deploy-ment testing. However, the glass braid insulation is only rated to a maximum continuous use temperature of 482ºC. For reference, the duration of the heat pulse on the LOFTID vehicle is on the order of minutes and themaximum predicted temperaturebeneaththe outermost FTPS layersis 1350ºC.Ground-based testing in a tube furnace at NASA Ames Research Centerwas conducted to determine if the baseline TCsrouted through FTPS samples would survive and provide accurate temperature measure-mentsat LOFTID flight-relevant temperatures[3].The test results showed large measurement errors occurred beginning at approximately 400°C due to conductive deposits on the TCinsulation electrically shorting the TCleads.The conductive deposits and thus electrical shorting weredetermined to be caused by twoerror sources:1.The organic binder on the TCinsulation carbon-izingin a high temperature, low oxygen envi-ronment2.Decomposition products from the FTPSperme-atingthe braided TC insulationFurther testing in the tube furnace demonstrated that heat cleaning the TCinsulation effectivelyremovedthe organic binder andeliminatedthe first error source.The second error sourcewas shown to be mitigated by the addition of amica wraparound each individual TCleadtoact as an impermeable barrier.To understand the applicability of theground-based tube furnace test results to flight,anarc jet testseriesat Boeing’s Large Core Arc Tunnel (LCAT) facilitywas conducted[4].The error sourcesand mitigation strate-giesidentified in the tube furnace testing were substan-tiatedin the arc jet testing.However, the arc jet testing also revealed three new error sources:1.Glass TCinsulation meltingwhich resultsin electrical shorting of the TCeither through di-rect contact between the two leads or through the electrically conductive FTPS materials2.TCwire meltingwhich results in a noisy and/or open-loop TCresponse3.Type K TCwire green-rotwhich results in large calibration errors Scope of the Presentation:This presentation will include a brief discussion onthe effect of electrical shorting on the output of a TC(i.e. how to identify elec-trical shorting in TCdataand what the associated erroris).The tube furnace and arc jet test resultswill be dis-cussedand the solutions LOFTID is implementing to mitigate the error sourcesidentified in the tube furnace and arc jet testingwill be presented.Additionally, futureresearch and development work to eliminateTCerror sourcesfor future missionswill be recommended.

R A Miller↗

Mars transit vehicle thermal protection system: Issues, options, and trades

A Mars mission is characterized by different mission phases. The thermal control of cryogenic propellant in a propulsive vehicle must withstand the different mission environments. Long term cryogenic storage may be achieved by passive or active systems. Passive cryo boiloff management features will include multilayer insulation, vapor cooled shield, and low conductance structural supports and penetrations. Active boiloff management incorporates the use of a refrigeration system. Key system trade areas include active verses passive system boiloff management (with respect to safety, reliability, and cost) and propellant tank insulation optimizations. Technology requirements include refrigeration technology advancements, insulation performance during long exposure, and cryogenic fluid transfer system for mission vehicle propellant tanking during vehicle buildip in LEO.

Brown, Norman↗

Investigation of Post-Flight Solid Rocket Booster Thermal Protection System

After every Shuttle mission, the Solid Rocket Boosters (SRBs) are recovered and observed for missing material. Most of the SRB is covered with a cork-based thermal protection material (MCC-l). After the most recent shuttle mission, STS-114, the forward section of the booster appeared to have been impacted during flight. The darkened fracture surfaces indicated that this might have occurred early in flight. The scope of the analysis included microscopic observations to assess the degree of heat effects and locate evidence of the impact source as well as chemical analysis of the fracture surfaces and recovered foreign material using Fourier Transform Infrared Spectroscopy and Scanning Electron Microscopy/Energy Dispersive Spectroscopy. The amount of heat effects and presence of soot products on the fracture surface indicated that the material was impacted prior to SRB re-entry into the atmosphere. Fragments of graphite fibers found on these fracture surfaces were traced to slag inside the Solid Rocket Motor (SRM) that forms during flight as the propellant is spent and is ejected throughout the descent of the SRB after separation. The direction of the impact mark matches with the likely trajectory of SRBs tumbling prior to re-entry.