Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Vacuum Testing Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Vibration Isolation System for Use in a Large Thermal Vacuum Test Facility

A thermal vacuum payload platform that is isolated from background vibration is required to support the development of future instruments for Hubble Space Telescope (HST) and the Next Generation Space Telescope (NGST) at the Goddard Space Flight Center (GSFC). Because of the size and weight of the thermal/vacuum facility in which the instruments are tested, it is not practical to isolate the entire facility externally. Therefore, a vibration isolation system has been designed and fabricated to be installed inside the chamber. The isolation system provides a payload interface of 3.05 m (10 feet) in diameter and is capable of supporting a maximum payload weight of 4536 kg (10,000 Lbs). A counterweight system has been included to insure stability of payloads having high centers of gravity. The vibration isolation system poses a potential problem in that leakage into the chamber could compromise the ability to maintain vacuum. Strict specifications were imposed on the isolation system design to minimize leakage. Vibration measurements, obtained inside the chamber, prior to installing the vibration isolation system, indicated levels in all axes of approximately 1 milli-g at about 20 Hz. The vibration isolation system was designed to provide a minimum attenuation of 40 dB to these levels. This paper describes the design and testing of this unique vibration isolation system. Problems with leakage and corrective methods are presented. Isolation performance results are also presented.

Hershfeld, Donald↗

Testing of an Amine-Based Pressure-Swing System for Carbon Dioxide and Humidity Control

In a crewed spacecraft environment, atmospheric carbon dioxide (CO2) and moisture control is crucial. Hamilton Sundstrand has developed a stable and efficient amine-based CO2 and water vapor sorbent, SA9T, that is well-suited for use in a spacecraft environment. The sorbent is efficiently packaged in pressure-swing regenerable beds that are thermally linked to improve removal efficiency and minimize vehicle thermal loads. Flows are all controlled with a single spool valve. This technology has been baselined for the new Orion spacecraft. However, more data was needed on the operational characteristics of the package in a simulated spacecraft environment. A unit was therefore tested with simulated metabolic loads in a closed chamber at Johnson Space Center during the last third of 2006. Tests were run at a variety of cabin temperatures and with a range of operating conditions varying cycle time, vacuum pressure, air flow rate, and crew activity levels. Results of this testing are presented and potential flight operational strategies discussed.

Lin, Amy↗

Laser Beam Welding Benchmark Experiments Performed in Reduced Gravity and Vacuum

Laser beam welding (LBW) is affected by the extreme temperatures, reduced pressure, and reduced gravity present in space environments. Gravity and pressure especially influence its melt pool and solidification dynamics. A compact, modular vacuum chamber adaptable to flight platforms from parabolic to orbital currently hosts an experiment to investigate the combined influence of reduced gravity and pressure on LBW. A swappable cartridge contains a rotating platen on which customizable workpieces can be welded under vacuum, greatly increasing experimental throughput. Instrumentation includes weld and thermal cameras observing the process, thermocouples placed on workpieces, accelerometers, and vacuum sensors. Experimental data gathered during the welding process will be combined with post-flight nondestructive evaluation, metallography, and mechanical testing to provide validation datasets for computational modeling. Phase I of this effort involves a parabolic flight campaign in low gravity while an anticipated Phase II would proceed to in-space demonstration to access extended duration microgravity.

in-space welding↗

Simulated Space Environmental Testing on Thin Films

An exploratory program has been conducted, to irradiate some mature commercial and some experimental polymer films with radiation simulating certain Earth orbits, and to obtain data about the response of each test film's reflective and tensile properties. Protocols to conduct optimized tests were considered and developed to a "prototype" level during this program. Fifteen polymer film specimens were arranged on a specially designed test fixture. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture containing the films was installed in a clean vacuum chamber where protons, electrons and solar ultraviolet (UV) radiation could simultaneously irradiate the specimens. Near realtime UV rates were used, whereas proton and electron rates were accelerated appreciably to simulate 5 years in orbit during a two month test. Periodically, the spectral reflectance of each film was measured in situ. After the end of the irradiation, final reflectance measurements were made in situ, and solar absorptance values were derived for each specimen. These samples were then measured in air for thermal emittance and for tensile strength. Most specimens withstood the irradiation intact, but with reduced reflectance (increased solar absorptance). Thermal emittance changed slightly in several materials, as did their tensile strength and elongation at break. Conclusions are drawn about the performance of the films. Simulated testing to an expected 5 year dose of electrons and protons consistent with those expected at L2 and 0.98 AU orbits and 100 equivalent solar hours exposure.

Russell, Dennis A.↗

Advances in Current Rating Techniques for Flexible Printed Circuits

Twist Capsule Assemblies are power transfer devices commonly used in spacecraft mechanisms that require electrical signals to be passed across a rotating interface. Flexible printed circuits (flex tapes, see Figure 2) are used to carry the electrical signals in these devices. Determining the current rating for a given trace (conductor) size can be challenging. Because of the thermal conditions present in this environment the most appropriate approach is to assume that the only means by which heat is removed from the trace is thru the conductor itself, so that when the flex tape is long the temperature rise in the trace can be extreme. While this technique represents a worst-case thermal situation that yields conservative current ratings, this conservatism may lead to overly cautious designs when not all traces are used at their full rated capacity. A better understanding of how individual traces behave when they are not all in use is the goal of this research. In the testing done in support of this paper, a representative flex tape used for a flight Solar Array Drive Assembly (SADA) application was tested by energizing individual traces (conductors in the tape) in a vacuum chamber and the temperatures of the tape measured using both fine-gauge thermocouples and infrared thermographic imaging. We find that traditional derating schemes used for bundles of wires do not apply for the configuration tested. We also determine that single active traces located in the center of a flex tape operate at lower temperatures than those on the outside edges.

Hayes, Ron↗

Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA Subassembly (MTSAS) was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort was testing in a simulated lunar environment. This environment was simulated in Paragon's EHF vacuum chamber. The objective of the testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. Lunar environment testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 Nomenclature loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This exceeded any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.

Padilla, Sebastian A.↗

On Possible Arc Inception on Low Voltage Solar Array

Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 of all registered failures and anomalies, and comprised the most costly losses (25) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over coverglass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in coverglass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent sustained discharges between adjacent strings, and many ground tests were performed to determine threshold parameters (voltage and current) for sustained arcs. And again, manufacturing defects and aging in space environments may result in considerable decrease of critical threshold parameters. This paper is devoted to the analysis of possible reasons behind arcing on spacecraft with low bus voltages.

plasma interaction↗

On Possible Arc Inception on Low Voltage Solar Array

Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 percent of all registered failures and anomalies, and comprised the most costly losses (25 percent) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over cover-glass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in cover-glass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent sustained discharges between adjacent strings, and many ground tests were performed to determine threshold parameters (voltage and current) for sustained arcs. And again, manufacturing defects and aging in space environments may result in considerable decrease of critical threshold parameters. This paper is devoted to the analysis of possible reasons behind arcing on spacecraft with low bus voltages.

low voltage solar array↗

An endurance test of a 900 series 30-cm engineering model ion thruster

The 10,000 hour endurance test of the first engineering model 30-cm thruster (S/N 701) identified discharge chamber erosion as a life limiting problem. Modifications to minimize this problem have been implemented in the 900 series thrusters. This paper describes a test conducted to evaluate the success of these modifications. The post-test analysis results of thruster 701 are summarized and the erosion reducing modifications described. Test results for thruster 901 up to 4165 hours, when the test was interrupted by a shorted wire, are described. The conclusions of a post-test examination of thruster 901 are included. Also being evaluated was a thermal vacuum breadboard SCR series inverter power processor which is described.

Collett, C. R.↗

Analysis of particulates of comet nucleus samples: Possible use of olivine as indicator phase

The electron microprobe is a proven instrument for particulate analysis and modifications are possible for in situ analysis of particulates in ice at temperatures near that of liquid nitrogen. Present sample requirements allow for polished samples with 0.25 x 0.25 dimensions to be maintained in the sample chamber of a modern electron probe (CAMECA SX-50) at a temperature of -150 C; larger samples are possible but at higher temperatures as determined by thermal conductivity. The major problem is transport and insertion of samples into the instrument through vacuum interlocks. The manufacturer of the above microprobe has designed an exchange mechanism to allow storage and transport of samples previously prepared for their sample holder which attaches to their instrument allowing extraction and insertion of samples while maintaining -150 C temperature. An important test will be the capability of preparing polished surfaces of an ice-particulate sample without loss of particles and at low temperatures. While thin sections of water ice are routine, these are not examined for particulate material and are prepared at temperatures easily obtained in room-size volumes. Anticipated problems include rounding of small grains in the relatively soft ice matrix and the technical problem of dry polishing.

Steele, I. M.↗

The NIRCam Optical Telescope Simulator (NOTES)

The Near Infra-Red Camera (NIRCam), the 0.6-5.0 micron imager and wavefront sensing instrument for the James Webb Space Telescope (JWST), will be used on orbit both as a science instrument, and to tune the alignment of the telescope. The NIRCam Optical Telescope Element Simulator (NOTES) will be used during ground testing to provide an external stimulus to verify wavefront error, imaging characteristics, and wavefront sensing performance of this crucial instrument. NOTES is being designed and built by NASA Goddard Space Flight Center with the help of Swales Aerospace and Orbital Sciences Corporation. It is a single-point imaging system that uses an elliptical mirror to form an U20 image of a point source. The point source will be fed via optical fibers from outside the vacuum chamber. A tip/tilt mirror is used to change the chief ray angle of the beam as it passes through the aperture stop and thus steer the image over NIRCam's field of view without moving the pupil or introducing field aberrations. Interchangeable aperture stop elements allow us to simulate perfect JWST wavefronts for wavefront error testing, or introduce transmissive phase plates to simulate a misaligned JWST segmented mirror for wavefront sensing verification. NOTES will be maintained at an operating temperature of 80K during testing using thermal switches, allowing it to operate within the same test chamber as the NIRCam instrument. We discuss NOTES' current design status and on-going development activities.

Kubalak, David↗

Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption Technology

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA subassembly was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort is operations and testing in a simulated lunar environment. This environment was simulated in Paragon s EHF vacuum chamber. The objective of this testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. The lunar testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This had not been achieved in any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.

Padilla, Sebastian A.↗

James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

JWST Integrated Science Instruments Module (ISIM) completed its system-level space simulation testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered to the next level of integration with the Optical Telescope Element (OTE), to form OTIS (OTE + ISIM), after concluding a series of three cryo-vacuum (CV) tests. During these tests, the complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration following mechanical environmental tests (vibration and acoustics). From one test to the next, shortcomings of the facility were uncovered and associated improvements in operational capabilities and reliability of the facility were required to enable the project to verify system-level requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

Yew, Calinda↗

Solar Absorptivity Degradation of Spacecraft Materials Due to UV and Charged Particles in the Gateway Environment

The Gateway Passive Thermal Control System (PTCS) Group has identified charged particle and UV degradation of Gateway materials as a knowledge gap for the Near Rectilinear Halo Orbit (NRHO) and transit environment. Candidate materials and coatings were subjected to expected mission UV and charged particle environments at NASA Goddard Space Flight Center (GSFC). In situ change in reflectivity was observed at specified intervals during testing such that change in solar absorptivity could be plotted as a function of time of solar exposure. Gateway will be an outpost in cislunar space designed to survive a 15-year mission to support human moon landings and future deep space exploration. The Gateway Passive Thermal Control System (PTCS) Group has identified charged particle and UV degradation of potential Gateway materials as a knowledge gap for the Near Rectilinear Halo Orbit (NRHO) and transit environment, especially the slow spiral transit planned for the first two modules. Solar absorptivity degradation is important to quantify because the end-of-life absorptivity impacts thermal performance of the system. To address this, ground testing is being completed at NASA Goddard Space Flight Center in which potential Gateway materials, including radiators, multi-layer insulation (MLI), and structural materials are subjected to the expected transit plus 15-year on-orbit charged particle fluence (9.86x1015 protons/cm2 at 2.5 keV and 3.1x1016 electrons/cm2 at 10 keV) and up to 5000 Equivalent Solar Hours (ESH). Reflectivity of a single sample of each material was measured in atmosphere and in vacuum inside the chamber after exposure to incremental levels of ESH and charged particle fluence. Increase in absorptivity of most samples were seen throughout the test including large differences in absorptivity of materials of the same category. Future testing will validate these results and include additional materials of interest.

materials in the space environment↗

Ultrastable environment control for the NEID spectrometer: design and performance demonstration

Two key areas of emphasis in contemporary experimental exoplanet science are the detailed characterization of transiting terrestrial planets and the search for Earth analog planets to be targeted by future imaging missions. Both of these pursuits are dependent on an order-of-magnitude improvement in the measurement of stellar radial velocities (RV), setting a requirement on single-measurement instrumental uncertainty of order 10 cm∕s. Achieving such extraordinary precision on a high-resolution spectrometer requires thermomechanically stabilizing the instrument to unprecedented levels. We describe the environment control system (ECS) of the NEID spectrometer, which will be commissioned on the 3.5-m WIYN Telescope at Kitt Peak National Observatory in 2019, and has a performance specification of on-sky RV precision <50 cm/s. Because NEID’s optical table and mounts are made from aluminum, which has a high coefficient of thermal expansion, sub-milliKelvin temperature control is especially critical. NEID inherits its ECS from that of the Habitable-Zone Planet Finder (HPF), but with modifications for improved performance and operation near room temperature. Our full-system stability test shows the NEID system exceeds the already impressive performance of HPF, maintaining vacuum pressures below 10(exp −6) Torr and a root mean square (RMS) temperature stability better than 0.4 mK over 30 days. Our ECS design is fully open-source; the design of our temperature-controlled vacuum chamber has already been made public, and here we release the electrical schematics for our custom temperature monitoring and control system.

Paul Robertson↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Bismuth Propellant Feed System Development at NASA-MSFC

NASA-MSFC has been developing liquid metal propellant feed systems capable of delivering molten bismuth at a prescribed mass flow rate to the vaporizer of an electric thruster. The first such system was delivered to NASA-JPL as part of the Very High Isp Thruster with Anode Layer (VHITAL) program. In this system, the components pictured were placed in a vacuum chamber and heated while the control electronics were located outside the chamber. The system was successfully operated at JPL in conjunction with a propellant vaporizer, and data was obtained demonstrating a new liquid bismuth flow sensing technique developed at MSFC. The present effort is aimed at producing a feed-system for use in conjunction with a bismuth-fed Hall thruster developed by Busek Co. Developing this system is more ambitious, however, in that it is designed to self-contain all the control electronics inside the same vacuum chamber as an operating bismuth-fed thruster. Consequently, the entire system, including an on-board computer, DC-output power supplies, and a gas-pressurization electro-pneumatic regulator, must be designed to survive a vacuum environment and shielded to keep bismuth plasma from intruding on the electronics and causing a shortcircuit. In addition, the hot portions of the feed system must be thermally isolated from the electronics to avoid failure due to high heat loads. This is accomplished using a thermal protection system (TPS) consisting of multiple layers of aluminum foil. The only penetrations into the vacuum chamber are an electrically isolated (floating) 48 VDC line and a fiberoptic line. The 48 VDC provides power for operation of the power supplies and electronics co-located with the system in the vacuum chamber. The fiberoptic Ethernet connection is used to communicate user-input control commands to the on-board computer and transmit real-time data back to the external computer. The partially assembled second-generation system is shown. Before testing at Busek, a more detailed flow sensor calibration will be performed to accurately quantify the flow monitoring capabilities. This effort is funded under a Technology Innovation Program (TIP) award from NASA-MSFC's Technology Transfer office and performed under SAA8-061060.

Polzin, Kurt A.↗

Evaluation of GLAS Demonstration Model Loop Heat Pipe Thermal Vacuum Performance with Various Fluid Charges

Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser a radiator, the other will transport 190 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. This along with some non-ideal flight design compromises, such as a less than ideal charge level for this design concept with a symmetrical secondary wick, lead to inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. This presentation focuses on identifying; the sources of the flight test difficulties by modifying the charge and test setup of the successfully tested Development Model Loop Heat Pipe (DM LHP). While very similar to the flight design, the DM L14P did have several significant difference in design and method of testing. These differences were evaluated for affect on performance by conforming the DM LHP to look more like the flight units. The major difference that was evaluated was the relative fill level of the working fluid within the concentrically design LHP compensation chamber. Other differences were also assessed through performance testing including starter heater size and "hot biasing" of major interior components. Performance was assessed with respect to startup, low power operation, conductance, and control heater power. The results of the testing showed that performance improves as initial charge increases, and when the starter heater is made smaller. The "hot biasing" of the major components did not appear to have a detrimental effect. As a result of test results of the DM LHP, modifications are being made to the flight units to increase the fluid charge and increase the watt-density of the starter heater.

Baker, Charles↗