Performance Assessment of Different Pulse Reconstruction Algorithms for the ATHENA X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.

microcalorimeters↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

PIPER Continuous Adiabatic Demagnetization Refrigerator

We report upon the development and testing of a 4-stage adiabatic demagnetization refrigerator (ADR) capable of continuous cooling at 0.100 Kelvin. This cooler is being built to cool the detector array aboard NASA's Primordial Inflation Polarization Explorer (PIPER) observatory. The goal of this balloon mission is to measure the primordial gravitational waves that should exist if the theory of cosmological inflation is correct. At altitude, the ADR will hold the array of transition-edge sensors at 100 mK continuously while periodically rejecting heat to a 1.2 K pumped helium bath. During testing on ground, the array is held at the same temperature but heat is rejected to a 4.2 K helium bath indicating the flexibility in this coolers design.

Magnetic Cooling Sub-Kelvin ADR↗

Design of Magnetic Shielding and Field Coils for a TES X-Ray Microcalorimeter Test Platform

The performance of Transition-Edge Sensors (TES) and their SQUID multiplexed read-outs are very sensitive to the ambient magnetic field from Earth and fluctuations that can arise due to fluctuating magnetic fields outside of the focal plane assembly from the Adiabatic Demagnetization Refrigerator (ADR).Thus, the experimental platform we are building to test the FPA of the X-ray Integral Field Unit (X-IFU) of the Athena mission needs to include a series of shields and a coil in order to meet the following requirement of magnetic field density and uniformity.

Miniussi, Antoine R.↗

Performance of an X-ray Microcalorimeter with a 240 μm Absorber and a 50 μm TES Bilayer

Superconducting transition-edge sensor (TES) microcalorimeters are being developed for a variety of potential astrophysics missions, including Athena. The X-ray integral field unit instrument on this mission requires close-packed pixels on a 0.25 mm pitch, and high quantum efficiency between 0.2 and 12 keV. In this work, we describe a new approach with 50 μm square TESs consisting of a Mo/Au bilayer, deposited on silicon nitride membranes to provide a weak thermal conductance to a ~50 mK heat bath. Larger TESs usually have additional normal metal stripes on top of the bilayer to reduce the noise. However, we have found that excellent spectral performance can be achieved without the need for any normal metal stripes on top of the TES. A spectral performance of 1.58+/-0.12 eV at 5.9 keV has been achieved, the best resolution seen in any of our devices with this pixel size.

Miniussi, Antoine R.↗

Characterization of Si-Membrane TES Bolometer Arrays for the HIRMES Instrument

The High Resolution Mid-Infrared Spectrometer (HIRMES) instrument will fly onboard NASA's airborne Stratospheric Observatory for Infrared Astronomy (SOFIA) in 2019. HIRMES will provide astronomers with a unique observing window (25 122 µm) for exploring the evolution of protoplanetary disks into young solar systems, and the composition of our Solar System. There are two focal plane detector arrays for the instrument: a high-resolution (/ = 100,000) 8x16 detector array with a target noise-equivalent power, NEP 3x10-18 W/Hz; and a low-resolution (/ = 2,000 19,000) 16x64 detector array with a target NEP 2x10-17 W/Hz. The detectors for both of these arrays are superconducting Mo/Au bilayer transition edge sensor (TES) bolometers on thin suspended single-crystal silicon membranes. Here we present our characterization results for the detectors in both arrays, including measurements of thermal conductance with comparison to phonon transport models, saturation power, noise, and array uniformity.

Instrumentation and Photography↗

The Primordial Inflation Polarization Explorer (PIPER): Current Status and Performance of the First Flight

The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne instrument optimized to measure the polarization of the CMB at large angular scales. It will map 85% of the sky over a series of conventional balloon flights from the Northern and Southern hemispheres, measuring the B-mode polarization power spectrumover a range of multipoles from 2-300 covering both the reionization bump and the recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007. PIPER will observe in four frequency bands centered at 200, 270, 350, and 600 GHz to characterize dust foregrounds. The instrument has background-limited sensitivity provided by fully cryogenic (1.7 K) optics focusing the sky signal onto kilo-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 100 mK. Polarization sensitivity and systematiccontrol are provided by front-end Variable-delay Polarization Modulators (VPMs). PIPER had its engineering flight in October 2017 from Fort Sumner, New Mexico. This papers outlines the major components in the PIPER system discussing the conceptual design as well as specific choices made for PIPER. We also report on the results of the engineering flight, looking at the functionality of the payload systems, particularly VPM, as well as pointing out areas of improvement.

Pawlyk, Samuel↗

Extended Line Spread Function of TES Microcalorimeters with Au/Bi Absorbers

Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, low-level non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the x-ray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several x-ray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.

Superconducting devices↗

Design of Magnetic Shielding and Field Coils for a TES X-Ray Microcalorimeter Test Platform

The performance of transition-edge sensors (TES) and their SQUID multiplexed readouts is very sensitive to ambient magnetic field and its fluctuations. In order to run ground experiments on thousands of X-ray TES microcalorimeters with a small uniform ambient magnetic field (< 1 μT, with a uniformity < 0.1 μT), we need a very low ambient field to be trapped into the superconducting magnetic shields. We have designed a sub-Kelvin test platform to reach these specifications. For this purpose, we modeled a new design for the shielding consisting of a series of different mu-metal and superconducting shields, including a niobium shield at 50 mK, a cryoperm (A4K) shield at 3 K, and a mu-metal shield at 300 K. A magnetic field coil is used to vary the local perpendicular magnetic field over the TES array. To optimize this field, we have studied a number of different field-coil designs and the impact of the different shield geometries, in order to reach the required field uniformity.

Miniussi, Antoine R.↗

Sub-Kelvin Cooling for Two Kilopixel Bolometer Arrays in the PIPER Receiver

The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne telescope mission to search for inflationary gravitational waves from the early universe. PIPER employs two 32 × 40 arrays of superconducting transition-edge sensors, which operate at 100 mK. An open bucket Dewar of liquid helium maintains the receiver and telescope optics at 1.7 K. We describe the thermal design of the receiver and sub-Kelvin cooling with a continuous adiabatic demagnetization refrigerator (CADR). The CADR operates between 70 and 130 mK and provides ≈10 μW cooling power at 100 mK, nearly five times the loading of the two detector assemblies. We describe electronics and software to robustly control the CADR, overall CADR performance in flightlike integrated receiver testing, and practical considerations for implementation in the balloon float environment.

Switzer, E. R.↗

First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket

Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.

TES↗

Overview of the Medium and High Frequency Telescopes of the LiteBIRD Satellite Mission

LiteBIRD is a JAXA-led Strategic Large-Class mission designed to search for the existence of the primordial gravitational waves produced during the inflationary phase of the Universe, through the measurements of their imprint onto the polarization of the cosmic microwave background (CMB). These measurements, requiring unprecedented sensitivity, will be performed over the full sky, at large angular scales, and over 15 frequency bands from 34 GHz to 448 GHz. The LiteBIRD instruments consist of three telescopes, namely the Low-, Medium- and High-Frequency Telescope (respectively LFT, MFT and HFT). We present in this paper an overview of the design of the Medium-Frequency Telescope (89–224 GHz) and the High-Frequency Telescope (166–448 GHz), the so-called MHFT, under European responsibility, which are two cryogenic refractive telescopes cooled down to 5 K. They include a continuous rotating half-wave plate as the first optical element, two high-density polyethylene (HDPE) lenses and more than three thousand transition-edge sensor (TES) detectors cooled to 100 mK. We provide an overview of the concept design and the remaining specific challenges that we have to face in order to achieve the scientific goals of LiteBIRD.

LiteBIRD↗

Design and Fabrication of Metamaterial Anti-reflection Coatings for the Simons Observatory

The Simons Observatory (SO) will be a cosmic microwave background (CMB) survey experiment with three small-aperture telescopes and one large-aperture telescope, which will observe from the Atacama Desert in Chile. In total, SO will field over 60,000 transition-edge sensor (TES) bolometers in six spectral bands centered between 27 and 280 GHz in order to achieve the sensitivity necessary to measure or constrain numerous cosmological quantities, as outlined in The Simons Observatory Collaboration et al. (2019). These telescopes require 33 highly transparent, large aperture, refracting optics. To this end, we developed mechanically robust, highly efficient, metamaterial anti-reflection (AR) coatings with octave bandwidth coverage for silicon optics up to 46 cm in diameter for the 22-55, 75-165, and 190-310 GHz bands. We detail the design, the manufacturing approach to fabricate the SO lenses, their performance, and possible extensions of metamaterial AR coatings to optical elements made of harder materials such as alumina.

Joseph E. Golec↗

Assembly Development for the Simons Observatory Focal Plane Readout Module

The Simons Observatory (SO) is a suite of instruments sensitive to temperature and polarization of the cosmic microwave background (CMB) to be located at Cerro Toco in the Atacama Desert in Chile. Five telescopes, one large aperture telescope and four small aperture telescopes, will host roughly 70,000 highly multiplexed transition edge sensor (TES) detectors operated at 100 mK. Each SO focal plane module (UFM) couples 1,764 TESes to microwave resonators in a microwave multiplexing (μMux) readout circuit. Before detector integration, the100 mKμMux components are packaged into multiplexing modules (UMMs), which are independently validated to ensure they meet SO performance specifications. Here we present the assembly developments of these UMM readout packages for mid frequency (90/150 GHz) and ultra high frequency (220/280 GHz) UFMs.

Aamir M. Ali↗

Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration

The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.

J. S. Adams↗

SIRENA Software for Athena X-IFU Event Reconstruction

The X-ray Observatory Athena was proposed in April 2014 as the mission to implement the science theme "The Hot and Energetic Universe" selected by ESA for L2 (the second Large-class mission in ESAs Cosmic Vision science programme). One of the two X-ray detectors designed to be onboard Athena is X-IFU, a cryogenic microcalorimeter based on Transition Edge Sensor (TES) technology that will provide spatially resolved high-resolution spectroscopy. X-IFU will be developed by an international consortium led by IRAP (PI), SRON (co-PI) and IAPS/INAF (co-PI) and involving ESA Member States, Japan and the United States. In Spain, IFCA (CSIC-UC) has an anticipated contribution to X-IFU through the Digital Readout Electronics (DRE) unit, in particular in the Event Processor Subsytem. For this purpose and in collaboration with the Athena end-to-end simulations team, we are currently developing the SIRENA package as part of the publicly available SIXTE end-to-end simulator. SIRENA comprises a set of processing algorithms aimed at recognizing, from a noisy signal, the intensity pulses generated by the absorption of the X-ray photons, to lately reconstruct their energy, position and arrival time. This poster describes the structure of the package and the different algorithms currently implemented as well as their comparative performance in the energy resolution achieved in the reconstruction of the instrument events.

M T Ceballos↗

Far-infrared Imager and Polarimeter for the Origins Space Telescope

The far-infrared imager and polarimeter (FIP) for the Origins Space Telescope (Origins) is a basic far-infrared imager and polarimeter. The camera will deliver continuum images and polarization measurements at 50 and 250μm. Currently available detector technologies provide sufficient sensitivity for background limited observations from space, at least on a single pixel basis. FIP incorporates large next-generation superconducting detector arrays and our technology development plan will push the pixel numbers for the arrays to the required size of 8000. Two superconducting detector technologies are currently candidates for the instrument: transition edge sensors or microwave kinetic inductance devices. Using these detectors and taking advantage of the cryogenic telescope that is provided by Origins, FIP will achieve mapping speeds of up to eight orders of magnitude faster than what has been achieved by existing observatories. The science drivers for FIP include observations of solar system objects, dust properties, and magnetic field studies of the nearby interstellar medium, and large scale galaxy surveys to better constrain the star formation history of the universe to address one of the main themes of Origins: “How does the Universe work?” In addition to the science, the FIP instrument plays a critical functional role in aligning the mirrors during on orbit observatory commissioning.

Astronomy↗

Assembly and Integration Process of the High-Density Detector Array Readout Modules for the Simons Observatory

The Simons Observatory will measure the cosmic microwave background tempera-ture and polarization using a suite of new telescopes in the Atacama Desert in Chile. The Simons Observatory will use dichroic transition edge sensor (TES) bolometer arrays spanning six frequency bands from 27 to 280 GHz. The Simons Observa-tory will pioneer the use of a densely packed multiplexing architecture based on the microwave SQUID multiplexer ( 𝜇mux), housing ∼2000 microwave resonators, each coupled to a TES. The Simons Observatory aims to multiplex each array of ∼2000 detectors with a single pair of coaxial cables and requires a multiplexing factor of ∼1000 . The Simons Observatory cryogenic readout system is called the universal microwave multiplexing module (UMM). The UMM couples to both horn and lenslet-coupled detector arrays and is integrated into the universal focal-plane module (UFM) after being independently characterized. We present processes we have developed for highly repeatable and automated integration methods of UMMs, which will be needed for the production of the 49 UFMs required for the first stage of the Simons Observatory.