The Micro-Isolation Valve Concept: Initial Results of a Feasibility Study
A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated.
Manually operated liquid fuel control valve for Advanced Liquid Propulsion System /ALPS/
Inspection, proof pressure, and functional testing of check valve used in tank vent line of liquid hydrogen fuel system
Reliable anomaly detection and diagnosis are critical for the safe operation of complex engineered systems. This study presents a unified framework that integrates statistical, model-based, and data-driven techniques for anomaly detection and investigation, demonstrated on SMART valve systems in hybrid energy applications. Four detection methods—mean deviation, seasonal extreme studentized deviate, ARIMA forecasting, and matrix profiling—were implemented and compared. Matrix profiling was particularly effective in revealing subtle deviations and hidden relationships among variables. Anomaly investigation was performed by analyzing variable-level and grouped signal profiles, with system topology incorporated to distinguish primary faults from propagated effects. Grouping signals by type enhanced interpretability, enabling accurate localization of anomalies across multi-dimensional datasets. Experimental results confirmed the framework's capability to consistently detect and isolate anomalies while providing actionable insights into system interdependencies. The proposed methodology offers a robust, interpretable, and scalable solution for condition monitoring, with potential applications in safety-critical domains such as nuclear energy, aerospace, and process industries.
Semi-insulating manganese-doped gallium nitride (GaN:Mn) layers epitaxially grown on unintentionally doped GaN substrates were used as photoconductors in optically addressable light valves (OALVs) to withstand higher operational laser fluences compared to current state-of-the-art OALVs where bismuth silicon oxide (BSO; Bi 12 SiO 20 ) layers are used as photoconductors. GaN:Mn promises to be an exciting material for optoelectronic operations due to its large laser fluence handling capability and photoresponsivity near the band edge. The laser damage thresholds for the semi-insulating epitaxial GaN:Mn layer and the n-type substrate layer were measured to be 2.4 and 4.2 J/cm 2 , respectively. These are 6–10 times higher than that of BSO (0.4 J/cm 2 ). These measurements were performed by exposing ~200 sites on the samples to increasing fluence levels from a Gaussian pulsed Nd:YAG laser system (1064 nm) operating at a 5 Hz repetition rate with a 3 ns pulse width. Photoresponsivity of the GaN:Mn material was investigated at discrete wavelengths of 447, 405, and 380 nm. Further, the peak photoresponsivity was observed under an illumination wavelength of 380 nm and is attributed to stronger absorption. The OALV was fabricated by attaching a 110-μm-thick GaN:Mn layer grown on a 280-μm-thick n-GaN layer to a 3-mm-thick BK7 optical window. A twisted nematic E7 liquid crystal was introduced to the 5 μm gap between the two components. Transmission levels of >90% were achieved for the fabricated OALVs for a peak voltage of 40 V, constrained by transmission “bleed-through”.
This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • High-demand MOV SO failure rate • Low-demand MOV frequency of FTOC events (failures per reactor year) • High-demand MOV frequency of SO events (failures per reactor year).
Diverting valves for directing water flow in cooling system for burners in high temperature test tunnel
Transient pressure response in fluid system as vibrating valve closes
Antiflutter baffle plate and star spring combination for preventing squeal and impact damage in ball check valve used for high speed flow conditions
Propellant valve leakage and propellant flow system freezing and blockage when exposed to vacuum environment in Apollo service module engine
Fluid state control system with vortex valves for solid propellant gas generator flow throttling
Two way, latching, dc solenoid valve to isolate reaction control engine clusters from main hypergolic propellant supply system
Adverse effects of aerozine-50 leakage through propellant valves into injector manifolds exposed to vacuum environment
Proportional two-stage valve with closed loop pressure feedback logic for high temperature solid propellant pneumatic system
Proof pressure, functional, dielectric, humidity, temperature, vibration, life cycle, and impact tests for qualifying Saturn S-IB stage LOX REPLENISHING ball valve
Rapid opening mechanical gate valve consisting of blade assembly, blade catcher and primer holder used in conjunction with hypervelocity free flight range experiments