Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Single crystal growth in spin-coated films of polymorphic phthalocyanine derivative under solvent vapor

The effects of solvent vapor on spin-coated films of a polymorphic phthalocyanine derivative were investigated. Growth of single crystal films via redissolving organic films under solvent vapor was revealed by in situ microscopic observations of the films. X-ray diffraction measurement of the films after exposing to solvent vapor revealed the phase transition of polymorphs under solvent vapor. The direction of crystal growth was clarified by measuring the crystal orientation in a grown monodomain film. The mechanism of crystal growth based on redissolving organic films under solvent vapor was discussed in terms of the different solubilities of the polymorphs.

36 MATERIALS SCIENCE↗

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this work, we report a very slow electric-field-screening phenomenon with a timescale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Furthermore, using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm 3 and delivers a spectral noise floor of around 0.34 mV/m √Hz and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-basedatomic electrometry that was seldom studied before, which may enable more applications that use atomicelectric-field-sensing technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

MoSi 2 Oxidation in 670-1498 K Water Vapor

Molybdenum disilicide (MoSi 2 ) has well documented oxidation resistance at high temperature (T > 1273 K) in dry O 2 containing atmospheres due to the formation of a passive SiO 2 surface layer. But, its behavior under atmospheres where water vapor is the dominant species has received far less attention. Oxidation testing of MoSi 2 was performed at temperatures ranging from 670–1498 K in both 75% water vapor and synthetic air (Ar-O2, 80%–20%) containing atmospheres. Here the thermogravimetric and microscopy data describing these phenomena are presented. Over the temperature range investigated, MoSi 2 displays more mass gain in water vapor than in air. The oxidation kinetics observed in water vapor differ from that of the air samples. Two volatile oxides, MoO 2 (OH) 2 and Si(OH) 4 , are thought to be the species responsible for the varied kinetics, at 670–877 K and at 1498 K, respectively. Finally, we observed an increase in oxidation (140–300 mg/cm 2 ) from 980–1084 K in water vapor, where passivation is observed in air.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance and Durability of Proton Exchange Membrane Vapor-Fed Unitized Regenerative Fuel Cells

With a growing demand for electricity, clean hydrogen production and usage can be an asset not only to mitigate emissions but for long-term energy storage as well. Hydrogen gas, a high-density energy carrier, can be made through electrolysis in charging mode and generate electricity via a fuel cell in discharging mode in a unitized regenerative fuel cell (URFC). While URFCs reduce cost by combining the charging and discharging modes into a singular device, switching between modes becomes burdensome, and water management is a major challenge. One way to mitigate these issues is to operate the entire system in the vapor phase. Vapor-phase operation simplifies the physics of the system but will introduce losses within the system, primarily ohmic and mass transport during the charging mode. In this study, we explore the performance of a Proton-Exchange-Membrane (PEM)-URFC under vapor-phase conditions and the impact of different PEMs, feed gases, and relative humidity on the performance and durability. By tailoring operating conditions and membrane, the vapor-URFC achieves a roundtrip efficiency of 42% and a lifetime of 50,000 accelerated stress test cycles for fully humidified feeds. Discussion of vapor-URFC for energy storage and extensions to look at various applications shows the promise of this technology.

25 ENERGY STORAGE↗

An Investigation of Plume Response to Soil Vapor Extraction and Hypothetical Drum Failure

Core Ideas Soil vapor extraction (SVE) wells are an effective interim remediation technique. Flow and transport modeling assists in evaluation of vapor plume behavior. Plume simulations assuming drum failure and SVE provide a framework for remediation planning. A small borehole subset could be monitored for detection of VOC releases due to drum failure. Soil vapor extraction (SVE) has been used at sites across the Department of Energy complex, including sites where legacy subsurface wastes represent a potential source of groundwater contamination. At Los Alamos National Laboratory (LANL), leakage from waste drums buried at an inactive chemical waste site has created a subsurface vapor plume of volatile organic compounds (VOCs). Soil vapor extraction operation in 2015 and rebound testing through 2017 were successful in reducing the plume's mass and mitigating VOC migration toward the water table. However, the possibility that waste drums could fail and release VOCs could pose a challenge in the future. To explore the impacts of drum failure, as well as the capabilities of SVE remediation, we simulated hypothetical contaminant release scenarios and subsequent SVE remediation. Three‐dimensional subsurface VOC behavior, including advection, diffusion, and plume interactions with topography, were simulated using the porous flow simulator Finite Element Heat and Mass Transfer. Simulations of future site conditions have allowed identification of “sentry” boreholes that can be monitored for early detection in case of drum failure. Sentry boreholes can also be used to set concentration thresholds above which SVE should be initiated. For the LANL site, simulations show that SVE can be started 3 yr following drum failure and remain a viable remediation tool. More broadly, the principles outlined in this work can be used to support remediation planning at other subsurface waste sites. Predictive models of future releases can be analyzed to set concentration threshold values, guide selection of sentry boreholes, and increase operational efficiency.

54 ENVIRONMENTAL SCIENCES↗

Vapor Space Corrosion Testing Simulating The Environment Of Hanford Double Shell Tanks

As part of an integrated program to better understand corrosion in the high level waste tanks, Hanford has been investigating corrosion at the liquid/air interface (LAI) and at higher areas in the tank vapor space. This current research evaluated localized corrosion in the vapor space over Hanford double shell tank simulants to assess the impact of ammonia and new minimum nitrite concentration limits, which are part of the broader corrosion chemistry limits. The findings from this study showed that the presence of ammonia gas (550 ppm) in the vapor space is sufficient to reduce corrosion over the short-term (i.e. four months) for a Hanford waste chemistry (SY102 High Nitrate). These findings are in agreement with previous studies at both Hanford and SRS which showed ammonia gas in the vapor space to be inhibitive. The presence of ammonia in electrochemical test solution, however, was insufficient to inhibit against pitting corrosion. The effect of the ammonia appears to be a function of the waste chemistry and may have more significant effects in waste with low nitrite concentrations. Since high levels of ammonia were found beneficial in previous studies, additional testing is recommended to assess the necessary minimum concentration for protection of carbon steel. The new minimum R value of 0.15 was found to be insufficient to prevent pitting corrosion in the vapor space. The pitting that occurred, however, did not progress over the four-month test. Pits appeared to stop growing, which would indicate that pitting might not progress through wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NUCON Vapor Abatement Unit Performance on Hanford Tank Farm Chemicals of Potential Concern

This report provided the results and methods used in the NUCON Vapor Abatement Unit performance testing. The purpose of the Pacific Northwest National Laboratory (PNNL) testing was to assess the performance of the NUCON International, Inc., Vapor Abatement Unit (VAU) prototype for the reduction of Hanford Tank Farm vapors associated chemicals of potential concern (COPC). The testing was conducted in compliance with the PNNL Assessment of NUCON Vapor Abatement Unit for Single-Shell Tank (SST) Farm Off-Gas Chemicals of Potential Concern (COPCs) test plan. Performance testing started on May 4, 2018 and continued through June 13, 2018. Eleven (11) COPCs were chosen for testing out of the 61 identified COPCs. The COPCs were chosen either due to the importance of that COPC measured in Hanford high-level waste single-shell tank (SST) vapor emissions, as a surrogate to represent a class of COPC compounds, or both. Results of the performance tests are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Infrared Spectroscopy of Equilibrium Mixtures of Vapor-Phase Water and Hydrogen Fluoride

Hydrogen fluoride readily associates with water vapor in the air to form the H 2 O-HF complex, which has optical absorption properties that are different from those of unassociated hydrogen fluoride. Consequently, to accurately quantify the total amount of hydrogen fluoride coming from an industrial stack or vent, for example, requires that the complexed amount of hydrogen fluoride be accounted for. To do this, the equilibrium constant for the association reaction is needed. Using statistical mechanical methods, Adebayo and coworkers [Adebayo SLA, AC Legon and DJ Millen. 1991. J. Chem. Soc. Faraday Trans. 87:443-447.] made an estimate of this equilibrium constant based on measured and estimated spectroscopic values for the complex. This value is K eq = 84(18) but has never been confirmed experimentally. In the research described herein, we have measured the equilibrium constant for the formation of H 2 O-HF by monitoring the decrease in the infrared absorption features of water vapor and hydrogen fluoride in mixtures of these two vapors in a temperature-regulated cell. Our experimental values for K eq at 25 °C, based on the diminution of the water vapor and HF transitions, are 77(46) and 51(24), respectively. The decay of the spectral features continues long after (hours) the two vapors are mixed in the gas cell. This suggests that other reactions (the growth of a film of hydrofluoric acid, perhaps) are taking place. While the experimental results agree reasonably well with the calculated equilibrium value of Adebayo et al., further improvements in experimental and analysis techniques are needed to reduce the uncertainties in the experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polar Bear™ – Innovative Capture of Storage Tank Vapors

Polar Bear™ is a patented technology developed by the Energy & Environmental Research Center (EERC) to capture storage tank vapors and eliminate methane emissions from upstream oil- and gas-producing facilities. Sparked by early commercial investment, the EERC licensed the technology and extended the intellectual property to storage tanks. Polar Bear™ is uniquely engineered and adapted to individual lower-producing facilities where there is otherwise no economic alternative for capturing tank vapors. A high number of small producing oil and gas wells are distributed across the country. The aggregate contributes to a significant volume of emissions. Because of the lack of economy of scale, gas volumes from these facilities are typically not recovered and contribute to methane emissions. Polar Bear™ provides a fit-for-purpose compression solution that addresses cost by reducing complexity with respect to conventional vapor recovery units and eliminating oil changes. Unique to Polar Bear™ is the capability to separate oxygenated gas from storage tank vapors. Storage tanks are designed to “breathe,” allowing gas to enter and escape during internal level and temperature changes. This infiltration of air into the tank headspace imparts undesirable oxygen content with respect to pipeline gathering. Polar Bear™ separates the vapor stream, allowing oxygen-rich gas to be used as fuel on-site while recovering the liquids-rich portion of the gas where oxygen content is minimized. A prototype system was tested to verify process models, evaluate operational performance, and advance the technology readiness level from 5 to 6. Results provide a good match between experimental measurements and process models, indicating the models are useful for future scale-up and field design. Various mixtures of nitrogen and liquefied petroleum gas were tested to understand the mass balance of nitrogen and how it relates to the potential control of oxygen content. Findings indicate that less than 2000 ppm of oxygen is likely to remain in the liquid portion of the gas in field applications. The research and development prepare the technology for field implementation to eliminate routine and fugitive methane emissions from storage tanks.

02 PETROLEUM↗

Surface-Engineered Inorganic Nanoporous Membranes for Vapor and Pervaporative Separations of Water–Ethanol Mixtures

Surface wettability-tailored porous ceramic/metallic membranes (in the tubular and planar disc form) were prepared and studied for both vapor-phase separation and liquid pervaporative separations of water-ethanol mixtures. Superhydrophobic nanoceramic membranes demonstrated more selective permeation of ethanol (relative to water) by cross-flow pervaporation of liquid ethanol–water mixture (10 wt % ethanol feed at 80 °C). In addition, both superhydrophilic and superhydrophobic membranes were tested for the vapor-phase separations of water–ethanol mixtures. Porous inorganic membranes having relatively large nanopores (up to 8-nm) demonstrated good separation selectivity with higher permeation flux through a non-molecular-sieving mechanism. Due to surface-enhanced separation selectivity, larger nanopore-sized membranes (~5–100 nm) can be employed for both pervaporation and vapor phase separations to obtain higher selectivity (e.g., permselectivity for ethanol of 13.9 during pervaporation and a vapor phase separation factor of 1.6), with higher flux due to larger nanopores than the traditional size-exclusion membranes (e.g., inorganic zeolite-based membranes having sub-nanometer pores). The prepared superhydrophobic porous inorganic membranes in this work showed good thermal stability (i.e., the large contact angle remains the same after 300 °C for 4 h) and chemical stability to ethanol, while the silica-textured superhydrophilic surfaced membranes can tolerate even higher temperatures. These surface-engineered metallic/ceramic nanoporous membranes should have better high-temperature tolerance for hot vapor processing than those reported for polymeric membranes.

09 BIOMASS FUELS↗

The annual cycle and sources of relevant aerosol precursor vapors in the central Arctic during the MOSAiC expedition

Abstract. In this study, we present and analyze the first continuous time series of relevant aerosol precursor vapors from the central Arctic (north of 80° N) during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition. These precursor vapors include sulfuric acid (SA), methanesulfonic acid (MSA), and iodic acid (IA). We use FLEXPART simulations, inverse modeling, sulfur dioxide (SO2) mixing ratios, and chlorophyll a (chl a) observations to interpret the seasonal variability in the vapor concentrations and identify dominant sources. Our results show that both natural and anthropogenic sources are relevant for the concentrations of SA in the Arctic, but anthropogenic sources associated with Arctic haze are the most prevalent. MSA concentrations are an order of magnitude higher during polar day than during polar night due to seasonal changes in biological activity. Peak MSA concentrations were observed in May, which corresponds with the timing of the annual peak in chl a concentrations north of 75° N. IA concentrations exhibit two distinct peaks during the year, namely a dominant peak in spring and a secondary peak in autumn, suggesting that seasonal IA concentrations depend on both solar radiation and sea ice conditions. In general, the seasonal cycles of SA, MSA, and IA in the central Arctic Ocean are related to sea ice conditions, and we expect that changes in the Arctic environment will affect the concentrations of these vapors in the future. The magnitude of these changes and the subsequent influence on aerosol processes remains uncertain, highlighting the need for continued observations of these precursor vapors in the Arctic.

Boyer, Matthew↗

Potassium Rankine cycle vapor chamber (heat pipe) radiator study

A structurally integrated vapor chamber fin (heat pipe) radiator is defined and evaluated as a potential candidate for rejecting waste heat from the potassium Rankine cycle powerplant. Several vapor chamber fin geometries, using stainless steel construction, are evaluated and an optimum is selected. A comparison is made with an operationally equivalent conduction fin radiator. Both radiators employ NaK-78 in the primary coolant loop. In addition, the Vapor Chamber Fin (VCF) radiator utilizes sodium in the vapor chambers. Preliminary designs are developed for the conduction fin and VCF concepts. Performance tests on a single vapor chamber were conducted to verify the VCF design. A comparison shows the conduction fin radiator easier to fabricate, but heavier in weight, particularly as meteoroid protection requirements become more stringent. While the analysis was performed assuming the potassium Rankine cycle powerplant, the results are equally applicable to any system radiating heat to space in the 900 to 1400 F temperature range.

Gerrels, E. E.↗

Vaporization characteristics of carbon heat shields under radiative heating.

Study of the vaporization characteristics of samples of ATJ graphite, a material that has been considered for use on a Jovian probe. These samples were subjected to radiative heating loads of approximately 2 kW/sq cm in argon atmospheres of pressures from 0.00046 to 1 atm. Surface temperatures, mass loss rates, and spatially resolved emission spectral data were recorded. These data are analyzed to determine carbon vapor pressure as a function of temperature and are compared with current models for the vapor pressure of carbon. The effects of finite vaporization (i.e., nonequilibrium) rates are considered and compared with experiment. Estimates of the heat of vaporization from an energy balance are also presented.

Davy, W. C.↗

Vapor chamber fin radiator study for the potassium Rankine cycle.

A structurally integrated vapor chamber fin (heat pipe) radiator is defined and evaluated as a potential candidate for rejecting waste heat from the potassium Rankine cycle powerplant. Several vapor chamber fin geometries, using stainless steel construction, are evaluated and an optimum is selected. A comparison is made with an operationally equivalent conduction fin radiator. Both radiators employ NaK-78 in the primary coolant loop. In addition, the Vapor Chamber Fin (VCF) radiator utilizes sodium in the vapor chambers. Preliminary designs are developed for the conduction fin and VCF concepts. Performance tests on a single vapor chamber were conducted to verify the VCF design.

Gerrels, E. E.↗

Vaporization of graphite in the temperature range of 4000 to 4500 K

The vaporization of graphite under intense laser radiation is considered both theoretically and experimentally. Under intense radiation, the mass-loss rate can be high enough to cause the flow in the laser plume to be supersonic. It is shown that under these conditions the vaporization process is coupled to the plume gasdynamics and the mass-loss rate for graphite is 62% of the free vaporization rate. Experimental results are presented for surface temperatures from 3985 to 4555 K and mass-loss rates from 0.56 to 27.0 g per sq cm sec. The results are used to determine the vapor pressure of graphite in a pressure range of 2 to 11 atm, and the values are shown to be in agreement with the JANAF vapor pressure curve.

Lundell, J. H.↗

Effect of degree of fuel vaporization upon emissions for a premixed prevaporized combustion system

An experimental and analytical study of the combustion of partially vaporized fuelair mixtures was performed to assess the impact of the degree of fuel vaporization upon emissions for a premixing-prevaporizing flametube combustor. Data collected show near linear increases in nitrogen oxide emissions with decreasing vaporization at equivalence ratios of 0.6. For equivalence ratio of 0.72, the degree of vaporization had very little impact on nitrogen oxide emissions. A simple mechanism which accounts for the combustion of liquid droplets in partially vaporized mixtures was found to agree with the measured results with fair accuracy with respect to both trends and magnitudes.

Cooper, L. P.↗

Global exchange of water vapor on Mars

Observations of the global distribution and seasonal variation of the Martian atmospheric water vapor have been made from the Viking orbiters for a continuous period covering more than half of a Martian year. The seasonal dependence of the latitude distribution of the column abundance of vapor is consistent with a model in which the vapor is in equilibrium with the regolith at polar and middle latitudes. The results indicate the existence of a permanent reservoir of water ice buried at a depth of 10 cm to 1 meter at all latitudes poleward of 40 deg. The behavior of the vapor in the summer hemisphere suggests an annual net transport of the vapor phase from the southern to the northern hemisphere, with deposition of ice of thickness on the order of a few milligrams per sq cm at northern polar latitudes. The hemispheric asymmetry is the result of the propagation of global dust storms originating in the south.

Farmer, C. B.↗