Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Operating Klystrons at the Spallation Neutron Source – Two Decades of Perspective

Klystron amplifiers have been operated at the Spallation Neutron Source (SNS) in support of the user program since 2006. SNS tubes have amassed over 100,000 hours of high-voltage and filament-on time providing a significant source of operational statistics for high power, high-duty klystrons. Additionally, the SNS Radiofrequency (RF) Systems Group has developed operational methods to mitigate specific reliability challenges, such as cathode arcing and output power instability. Despite much progress, many of these challenges persist, prompting the SNS to update the procedures used for klystron processing as well as develop a higher throughput test stand.

Moss, John [ORNL] (ORCID:0009000085988916)↗

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Axis-encircling electron beam generation using a smooth magnetic cusp for gyrodevices

The generation of an annular-shaped axis-encircling electron beam using a smooth magnetic cusp was studied through numerical simulations and experiments for harmonic operation of a gyrodevice. Two magnetic coils were used to form a magnetic cusp located just downstream from the velvet cathode of an accelerator diode. An electron beam of current 34 A and voltage 130 kV with an adjustable velocity ratio {alpha} up to 1.2 was fully transported to the downstream uniform magnetic field region and used to drive a gyrotron traveling wave amplifier into saturation.

43 PARTICLE ACCELERATORS↗

Solid state circuit switches ac load

Differential amplifier circuit switches ac signals with peak amplitudes greater than 5 volts. This solid state circuit biases a switching transistor on and off by a 0.1 to 5.0 dc control voltage.

Chapman, C. P.↗

Electronics for a focal plane crystal spectrometer

The HEAO-B program forced the usual constraints upon the spacecraft experiment electronics: high reliability, low power consumption, and tight packaging at reasonable cost. The programmable high voltage power supplies were unique in both application and simplicity of manufacture. The hybridized measurement chain is a modification of that used on the SAS-C program; the charge amplifier design in particular shows definite improvement in performance over previous work.

Goeke, R. F.↗

Efficient Power Amplifier for Motor Control

Pulse-width-modulated amplifier supplies high current as efficiently as low current needed for starting and running motor. Key to efficiency of motor-control amplifier is V-channel metal-oxide/semiconductor transistor Q1. Device has low saturation resistance. However, has large gate input capacitance and small margin between its turn-on voltage and maximum allowable gate-to-source voltage. Circuits for output stages overcome limitations of VMOS device.

Brown, R. J.↗

AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers

SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.

Gottardi, L.↗

500 MW X-Band RF System of a 0.25 GeV Electron LINAC for Advanced Compton Scattering Source Application

A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with the SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

43 PARTICLE ACCELERATORS↗

500 MW X-BAND RF SYSTEM OF A 0.25 GEV ELECTRON LINAC FOR ADVANCED COMPTON SCATTERING SOURCE APPLICATION

A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

42 ENGINEERING↗

Design and test of a 2.25-MW transformer rectifier assembly

A new 2.25-MW transformer rectifier assembly was fabricated for DSS-13 at Goldstone, California. The transformer rectifier will provide constant output power of 2.25 MW at any voltage from 31 kV to 125 kV. This will give a new capability of 1 MW of RF power at X-band, provided appropriate microwave tubes are in the power amplifier. A description of the design and test results is presented.

Cormier, R.↗

Dual physiological rate measurement instrument

The object of the invention is to provide an instrument for converting a physiological pulse rate into a corresponding linear output voltage. The instrument which accurately measures the rate of an unknown rectangular pulse wave over an extended range of values comprises a phase-locked loop including a phase comparator, a filtering network, and a voltage-controlled oscillator, arranged in cascade. The phase comparator has a first input responsive to the pulse wave and a second input responsive to the output signal of the voltage-controlled oscillator. The comparator provides a signal dependent on the difference in phase and frequency between the signals appearing on the first and second inputs. A high-input impedance amplifier accepts an output from the filtering network and provides an amplified output DC signal to a utilization device for providing a measurement of the rate of the pulse wave.

Cooper, Tommy G.↗

Magnetically Controlled Variable Transformer

Improved variable-transformer circuit, output voltage and current of which controlled by use of relatively small current supplied at relatively low power to control windings on its magnetic cores. Transformer circuits of this type called "magnetic amplifiers" because ratio between controlled output power and power driving control current of such circuit large. This ratio - power gain - can be as large as 100 in present circuit. Variable-transformer circuit offers advantages of efficiency, safety, and controllability over some prior variable-transformer circuits.

Kleiner, Charles T.↗

Optoelectronic associative memory

An associative optical memory including an input spatial light modulator (SLM) in the form of an edge enhanced liquid crystal light valve (LCLV) and a pair of memory SLM's in the form of liquid crystal televisions (LCTV's) forms a matrix array of an input image which is cross correlated with a matrix array of stored images. The correlation product is detected and nonlinearly amplified to illuminate a replica of the stored image array to select the stored image correlating with the input image. The LCLV is edge enhanced by reducing the bias frequency and voltage and rotating its orientation. The edge enhancement and nonlinearity of the photodetection improves the orthogonality of the stored image. The illumination of the replicate stored image provides a clean stored image, uncontaminated by the image comparison process.

Chao, Tien-Hsin↗

Single-Event Effect Testing of the Analog Devices AD8041ARZ Operational Amplifier

This study was undertaken to determine the single event transient distribution of a transimpedance amplifier configuration of the AD8041 Operational Amplifier. The AD8041 is made in a bipolar technology and the application of interest has a bipolar supply of ±5 V. The device was monitored for transient events on the output voltage during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory’s (LBNL) 88-inch Cyclotron.

Matthew B. Joplin↗

Surface Charge Distribution Mapping Using an Electrostatic Probe

Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.

36 MATERIALS SCIENCE↗

Design of spherical electron gun for ultra high frequency, CW power inductive output tube

Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gun has been carried out in CST and TRAK codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Xenon Gamma Detector Project Support

This project provided funding of $48,500 for part of one year to support the development of compressed xenon spectrometers at BNL. This report describes upgrades that were made to the existing detector system electronics during that period, as well as subsequent testing with check sources and Special Nuclear Materials. Previous testing of the equipment extended only up to the energy of 1.3 MeV, and did not include a spectrum of Pu-239. The new electronics allowed one-button activation of the high voltage ramp that was previously controlled by manual adjustments. Mechanical relays of the charging circuit were replaced by a tera-ohm resistor chain and an optical switch. The preamplifier and shaping amplifier were replaced by more modern custom designs. We found that the xenon purity had not been degraded since the chamber was filled 10 years earlier. The resulting spectra showed significantly better resolution than sodium iodide spectra, and could be analyzed quite effectively by methods using peak area templates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗