Search NASA⌕ Search

SEARCH · Search NASA

Results for “WALLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A wall interference assessment/correction system

A Wall Signature method originally developed by Hackett has been selected to be adapted for the Ames 12-ft Wind Tunnel WIAC system in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interference at the model location. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method--Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. The following two additional tasks are included: (1) On-line wall interference calculation: The developed wall signature method (modified Hackett's method) for Ames 12-ft Tunnel will be the pre-computed coefficients which facilitate the on-line calculation of wall interference, and (2) Support system effects estimation: The effects on the wall pressure measurements due to the presence of the model support systems will be evaluated.

Lo, C. F.↗

A Generalized Wall Function

The asymptotic solutions, described by Tennekes and Lumley (1972), for surface flows in a channel, pipe or boundary layer at large Reynolds numbers are revisited. These solutions can be extended to more complex flows such as the flows with various pressure gradients, zero wall stress and rough surfaces, etc. In computational fluid dynamics (CFD), these solutions can be used as the boundary conditions to bridge the near-wall region of turbulent flows so that there is no need to have the fine grids near the wall unless the near-wall flow structures are required to resolve. These solutions are referred to as the wall functions. Furthermore, a generalized and unified law of the wall which is valid for whole surface layer (including viscous sublayer, buffer layer and inertial sublayer) is analytically constructed. The generalized law of the wall shows that the effect of both adverse and favorable pressure gradients on the surface flow is very significant. Such as unified wall function will be useful not only in deriving analytic expressions for surface flow properties but also bringing a great convenience for CFD methods to place accurate boundary conditions at any location away from the wall. The extended wall functions introduced in this paper can be used for complex flows with acceleration, deceleration, separation, recirculation and rough surfaces.

Shih, Tsan-Hsing↗

Thermocapillary Flow and Aggregation of Bubbles on a Solid Wall

During the electrolytic evolution of oxygen bubbles forming on a vertically oriented transparent tin oxide electrode, bubbles were found to be mutually attractive. The mechanism of the aggregation had never been explained satisfactorily until Guelcher et al. attributed it to thermocapillary flow. The gradient of surface tension of the liquid at the bubble's surface, which was established because of reaction heat and ohmic heat loss at the electrode wall, drives flow of the liquid adjacent to each bubble; the bubble "pumps" fluid along its surface away from the wall. Fluid flows toward the bubble to conserve mass and entrains nearby bubbles in the flow pattern. The same logic would apply when two bubbles of equal size are adjacent to each other on a warm wall. Each bubble drives thermocapillary flow and hence entrains the other in its flow pattern, which drives the aggregation. Our objective here is to perform experiments where the temperature gradient at the wall is well known and controlled. The theory can be quantitatively tested by studying aggregation of bubble pairs of equal size, and by varying system parameters such as temperature gradient, bubble size and fluid viscosity. The results are then compared with the theory in a quantitatively rigorous manner. We demonstrate that the theory without adjustable parameters is capable of quantitatively modeling the rate of aggregation of two bubbles. The equations governing the thermocapillary flow around a single stationary bubble on a heated or cooled wall in a semi-infinite domain were solved. Both Reynolds number and Marangoni number were much less than unity. The critical result is that liquid in the vicinity of a warm wall flows toward a stationary collector bubble. Consequently the thermocapillary flow around the stationary bubble entrains another bubble toward itself. The bubbles undergo hindered translation parallel to the wall with velocity U while the fluid flow field is described with u. Two velocities were equated by using a wall hindrance parameter q: U = qu [1] which shows the velocity of bubble is proportional to the entraining velocity. The hindrance parameter q can experimentally be measured independently. q can also be calculated by solving the equations of motion for a bubble translating parallel to a solid wall. The experimental cell is cylindrical with an ID of 10 cm and consists of a 1 cm deep main cell filled with silicone oil and flanked by two thermal reservoirs. The upper thermal reservoir was heated and the lower thermal reservoir was cooled so that the bubbles aggregate. Two types of silicone oil (eta = 0.02 and 0.50 Pa s) were used. Two equal sized air bubbles were injected into the cell with a syringe. The center-to-center distance of bubbles was observed through a microscope. Bubble radius ranged from 0.40 mm to 0.65 mm and the temperature gradients along with the cell ranged from 1400 to 5000 K/m. The bubbles aggregated when heat flows from the wall to the fluid. The velocities of bubbles were in the range of 1 - 10 microns/s. The separation r decreased more quickly when the temperature gradient was higher, bubble size was larger, and the oil viscosity was lower. r decreased more rapidly as the bubbles approached each other. Dimensionless time was arbitrarily set to be zero when the dimensionless center-to-center distance between the bubbles was 4. All the bubble trajectories fall onto one line, especially in the range of dimensionless distance from 4 to 3. This means the relative movement of the bubble pair is proportional to the temperature gradient and bubble size and it is inversely proportional to the viscosity of the oil. This result strongly suggests that the thermocapillary flow-based aggregation mechanism is correct. A value of q can be estimated by fitting the scaled data to Eq. [1]. A best fit value of q was obtained as q = 0.26 with a standard deviation of 0.03. Independent experimental results for q for a 0.5 mm radius bubble, give values of q in the range 0.11 to 0.23. The value of q obtained from solving the equations of motion reveals q has values in the range 0.23 - 0.30. Since the full scale of possible values of q is zero to one, the maximum deviation of independently determined values of q from the best fit value was 15% of this full scale. Thus reasonable quantitative agreement between theory and experiment has been obtained.

Kasumi, Hiroki↗

Temperature modulates the cell wall mechanical properties of rice coleoptiles by altering the molecular mass of hemicellulosic polysaccharides

The present study was conducted to investigate the mechanism inducing the difference in the cell wall extensibility of rice (Oryza sativa L. cv. Koshihikari) coleoptiles grown under various temperature (10-50 degrees C) conditions. The growth rate and the cell wall extensibility of rice coleoptiles exhibited the maximum value at 30-40 degrees C, and became smaller as the growth temperature rose or dropped from this temperature range. The amounts of cell wall polysaccharides per unit length of coleoptile increased in coleoptiles grown at 40 degrees C, but not at other temperature conditions. On the other hand, the molecular size of hemicellulosic polysaccharides was small at temperatures where the cell wall extensibility was high (30-40 degrees C). The autolytic activities of cell walls obtained from coleoptiles grown at 30 and 40 degrees C were substantially higher than those grown at 10, 20 and 50 degrees C. Furthermore, the activities of (1-->3),(1-->4)-beta-glucanases extracted from coleoptile cell walls showed a similar tendency. When oat (1-->3),(1-->4)-beta-glucans with high molecular mass were incubated with the cell wall enzyme preparations from coleoptiles grown at various temperature conditions, the extensive molecular mass downshifts were brought about only by the cell wall enzymes obtained from coleoptiles grown at 30-40 degrees C. There were close correlations between the cell wall extensibility and the molecular mass of hemicellulosic polysaccharides or the activity of beta -glucanases. These results suggest that the environmental temperature regulates the cell wall extensibility of rice coleoptiles by modifying mainly the molecular mass of hemicellulosic polysaccharides. Modulation of the activity of beta-glucanases under various temperature conditions may be involved in the alteration of the molecular size of hemicellulosic polysaccharides.

Cellulose/chemistry/metabolism↗

CFD Code Validation of Wall Heat Fluxes for a G02/GH2 Single Element Combustor

This paper puts forth the case for the need for improved injector design tools to meet NASA s Vision for Space Exploration goals. Requirements for this improved tool are outlined and discussed. The potential for Computational Fluid Dynamics (CFD) to meet these requirements is noted along with its current shortcomings, especially relative to demonstrated solution accuracy. The concept of verification and validation is introduced as the primary process for building and quantifying the confidence necessary for CFD to be useful as an injector design tool. The verification and validation process is considered in the context of the Marshall Space Flight Center (MSFC) Combustion Devices CFD Simulation Capability Roadmap via the Simulation Readiness Level (SRL) concept. The portion of the validation process which demonstrates the ability of a CFD code to simulate heat fluxes to a rocket engine combustor wall is the focus of the current effort. The FDNS and Loci-CHEM codes are used to simulate a shear coaxial single element G02/GH2 injector experiment. The experiment was conducted a t a chamber pressure of 750 psia using hot propellants from preburners. A measured wall temperature profile is used as a boundary condition to facilitate the calculations. Converged solutions, obtained from both codes by using wall functions with the K-E turbulence model and integrating to the wall using Mentor s baseline turbulence model, are compared to the experimental data. The initial solutions from both codes revealed significant issues with the wall function implementation associated with the recirculation zone between the shear coaxial jet and the chamber wall. The FDNS solution with a corrected implementation shows marked improvement in overall character and level of comparison to the data. With the FDNS code, integrating to the wall with Mentor s baseline turbulence model actually produce a degraded solution when compared to the wall function solution with the K--E model. The Loci-CHEM solution, produced by integrating to the wall with Mentor s baseline turbulence model, matches both the heat flux rise rate in the near injector region and the peak heat flux level very well. However, it moderately over predicts the heat fluxes downstream of the reattachment point. The Loci-CHEM solution achieved by integrating to the wall with Mentor s baseline turbulence model was clearly superior to the other solutions produced in this effort.

Lin, Jeff↗

Navier-Stokes Computations With One-Equation Turbulence Model for Flows Along Concave Wall Surfaces

This report presents the use of a time-marching three-dimensional compressible Navier-Stokes equation numerical solver with a one-equation turbulence model to simulate the flow fields developed along concave wall surfaces without and with a downstream extension flat wall surface. The 3-D Navier- Stokes numerical solver came from the NASA Glenn-HT code. The one-equation turbulence model was derived from the Spalart and Allmaras model. The computational approach was first calibrated with the computations of the velocity and Reynolds shear stress profiles of a steady flat plate boundary layer flow. The computational approach was then used to simulate developing boundary layer flows along concave wall surfaces without and with a downstream extension wall. The author investigated the computational results of surface friction factors, near surface velocity components, near wall temperatures, and a turbulent shear stress component in terms of turbulence modeling, computational mesh configurations, inlet turbulence level, and time iteration step. The computational results were compared with existing measurements of skin friction factors, velocity components, and shear stresses of the developing boundary layer flows. With a fine computational mesh and a one-equation model, the computational approach could predict accurately the skin friction factors, near surface velocity and temperature, and shear stress within the flows. The computed velocity components and shear stresses also showed the vortices effect on the velocity variations over a concave wall. The computed eddy viscosities at the near wall locations were also compared with the results from a two equation turbulence modeling technique. The inlet turbulence length scale was found to have little effect on the eddy viscosities at locations near the concave wall surface. The eddy viscosities, from the one-equation and two-equation modeling, were comparable at most stream-wise stations. The present one-equation turbulence model is an effective approach for turbulence modeling in the near solid wall surface region of flow over a concave wall.

Wang, Chi R.↗

Validation of a Node-Centered Wall Function Model for the Unstructured Flow Code FUN3D

In this paper, the implementation of two wall function models in the Reynolds averaged Navier-Stokes (RANS) computational uid dynamics (CFD) code FUN3D is described. FUN3D is a node centered method for solving the three-dimensional Navier-Stokes equations on unstructured computational grids. The first wall function model, based on the work of Knopp et al., is used in conjunction with the one-equation turbulence model of Spalart-Allmaras. The second wall function model, also based on the work of Knopp, is used in conjunction with the two-equation k-! turbulence model of Menter. The wall function models compute the wall momentum and energy flux, which are used to weakly enforce the wall velocity and pressure flux boundary conditions in the mean flow momentum and energy equations. These wall conditions are implemented in an implicit form where the contribution of the wall function model to the Jacobian are also included. The boundary conditions of the turbulence transport equations are enforced explicitly (strongly) on all solid boundaries. The use of the wall function models is demonstrated on four test cases: a at plate boundary layer, a subsonic di user, a 2D airfoil, and a 3D semi-span wing. Where possible, different near-wall viscous spacing tactics are examined. Iterative residual convergence was obtained in most cases. Solution results are compared with theoretical and experimental data for several variations of grid spacing. In general, very good comparisons with data were achieved.

Carlson, Jan-Renee↗

Evaluation of Wall-Modeled Les for Flow Over A Multi-Element Airfoil

We perform wall-modeled large-eddy simulations (WMLES) of turbulent flow over a 30P30N multielement airfoil at various angles of attack to assess its ability to accurately predict lift using an unstructured node-based finite-volume methodology. The flow conditions are based on the experiments reported in Klausmeyer & Lin [NASA /TM-112858]. The oncoming flow Mach number is 0.2, and the stowed chord-based Reynolds number (𝑅𝑒𝑐) is 9 million. The angle of attack (𝛼) is varied between 8◦ and 23◦ with the expected stall angle of around 21◦. The simulated geometry is periodic in the span, thus any three-dimensional effects present in the experiment are ignored. We first analyze the predictions with baseline isotropic and anisotropic grids containing over 16 grid points per boundary-layer thickness. The near-wall streamwise/nominal spacing ratio is 0.4 at the leading/trailing edges of the slat, main element and flap, and 1 elsewhere, and the first wall-normal/nominal spacing ratio is 0.375 over most of the airfoil for the anisotropic grid, while these are unity for the isotropic grid. It is found that the predicted lift and wall pressures, near-wall velocity profiles, and the location of onset of resolved turbulence are sensitive to the near-wall grid anisotropy. Further sensitivities were explored at lower angles of attack by independently varying the streamwise and wall-normal grid anisotropies. The effects of both off-wall and near-wall grid refinement were also quantified. For the grid resolutions used here, our results suggest that the first wall-normal spacing, which coincides with the WMLES exchange location, has a dominant effect on the predictions for this flow configuration.

Computational Fluid Dynamics↗

Use of Phase Change Material in a Building Wall Assembly: A Case Study of Technical Potential in Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

36 MATERIALS SCIENCE↗

Wall Upgrades for Deep Energy Savings in Residential Buildings: Interim Results from a Multi-Year Study

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory and the University of Minnesota are conducting a three-year, multipart study on residential retrofit wall assemblies. The project is funded by the U.S. Department of Energy’s Building Technology Office and will identify, test and verify wall assemblies for hygrothermal performance in retrofit applications. The study includes a comprehensive literature review and expert advisory group, which inform wall selection. Selected wall assemblies are then thermally simulated using EnergyPlus and THERM, and hygrothermally simulated using WUFI, to model both thermal and moisture performance of the wall assembly. Eight wall assemblies are then experimentally tested in an in-situ laboratory environment at the University of Minnesota, with a typical residential wall used as a baseline. The in-situ experiment looks at the physical hygrothermal performance of each assembly. The simulation and experimental results will be combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits. This paper presents progress after year one of the study. Wall system modeling and laboratory testing is scheduled to begin in November, 2019. We will discuss the parameters for wall selection and experimental design, which includes approaches to modeling and simulation, along with the physical experiment design. This paper will also outline the parameters for the techno-economic analysis, and criteria used to inform model development.

Antonopoulos, Chrissi A.↗

Cost-Benefit Analysis of High-Strength Materials for Safety-Related Nuclear Reinforced Concrete Shear Walls

A numerical parametric investigation was conducted to determine the economic benefits of utilizing high-strength concrete and high-strength steel reinforcing bar (rebar) in reinforced concrete (RC) shear walls for nuclear power plant structures. Thick RC shear walls with low height-to-length aspect ratios (i.e., aspect ratios, h{sub w}/l{sub w}≤2.0, where h{sub w} is the wall height and l{sub w} is the wall length) are the most common lateral load resisting members in non-containment, safety-related nuclear structures. Typically, the walls are reinforced with multiple layers of overlapping, large-diameter vertical and horizontal rebar on each face. These heavily-reinforced walls provide large lateral stiffness and strength to prevent significant deformations and/or cracking that could compromise the integrity of the nuclear facility. However, this design adversely affects constructability as the rebar cages become highly congested. The time, labor, and materials required for this construction lead to high overall project costs. There has been a recent research thrust in the U.S. to allow high-strength rebar in non-nuclear building structures. While some of this research (e.g., steel properties, bond, anchorage) is applicable to RC structures in general, there are important differences specific to nuclear structures, such as much thicker walls (often controlled by radiation and thermal cycling), larger reinforcement ratios, and increased susceptibility to shear-controlled behavior (due to low aspect ratios). An important limiting factor for non-nuclear structures in seismic regions is the reduced deformation capacity of high-strength rebar as compared with normal-strength rebar used in current practice. Differences in seismic design philosophy lessen this limitation for nuclear structures (i.e., nuclear structures are designed more conservatively and allowed to undergo significantly smaller nonlinear displacements), making high-strength rebar a promising alternative to reinforcement currently permissible in the ACI 349-13 code requirements, which govern the design of nuclear safety-related concrete structures. To improve constructability and economy, this study investigates the benefits of using high-strength rebar [i.e., ASTM A615 Grade 550 (U.S. Grade 80); ASTM A1035 Grades 690 and 830 (U.S. Grades 100 and 120), where the grade indicates the specified yield strength of the steel in MPa (ksi)] together with high-strength concrete [compression strengths up to 138 MPa (20.0 ksi)] in RC nuclear shear walls. These strength ranges represent steel and concrete materials that are commercially available in the U.S. High-strength rebar can significantly reduce the required steel areas, thereby reducing material/fabrication costs, reducing rebar congestion (fewer/smaller bars and bar layers), and facilitating concrete consolidation and placement. Previous research on the use of high-strength rebar and/or high-strength concrete in nuclear RC structures does not exist in North America. A recent study assessed the potential of high-strength steel to reduce the rebar volume in non-nuclear building construction. In Japan, researchers investigated the use of high-strength materials in safety-related nuclear RC structures, but did not explore the economic benefits of these materials. To address this knowledge gap, the current paper describes a numerical parametric investigation on the potential cost savings of nuclear shear walls with high-strength rebar and/or concrete through comparisons against state-of-practice walls with normal-strength materials. Overall, the results demonstrate that significant economic benefits can be realized by implementing high-strength rebar and concrete in these structures. (authors)

36 MATERIALS SCIENCE↗

Cellulose synthase interactive1- and microtubule-dependent cell wall architecture is required for acid growth in Arabidopsis hypocotyls

Auxin-induced cell elongation relies in part on the acidification of the cell wall, a process known as acid growth that presumably triggers expansin-mediated wall loosening via altered interactions between cellulose microfibrils. Cellulose microfibrils are a major determinant for anisotropic growth and they provide the scaffold for cell wall assembly. Little is known about how acid growth depends on cell wall architecture. To explore the relationship between acid growth-mediated cell elongation and plant cell wall architecture, two mutants (jia1-1 and csi1-3) that are defective in cellulose biosynthesis and cellulose microfibril organization were analyzed. The study revealed that cell elongation is dependent on CSI1-mediated cell wall architecture but not on the overall crystalline cellulose content. We observed a correlation between loss of crossed-polylamellate walls and loss of auxin- and fusicoccin-induced cell growth in csi1-3. Furthermore, induced loss of crossed-polylamellate walls via disruption of cortical microtubules mimics the effect of csi1 in acid growth. We hypothesize that CSI1- and microtubule-dependent crossed-polylamellate walls are required for acid growth in Arabidopsis hypocotyls.

59 BASIC BIOLOGICAL SCIENCES↗

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High R-value wall assemblies (R-40 and above) are gaining popularity in the market due to programs such as the U.S. Department of Energy Zero Energy Ready Home program, Passive House, Net Zero Energy Home challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used double-wall systems to achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double-wall systems is that there are very few new exterior details. Exterior sheathings, structural bracings, house wraps or building paper, window and door flashings, and siding attachments are usually identical to good details in conventional framed-wall systems. However, although the details in double-wall systems are very similar to those in conventional stick framing, there is sometimes less room for error. Several studies have confirmed colder temperatures of exterior sheathing in high R-value wall assemblies that do not have exterior rigid foam insulation. These colder temperatures can lead to increased chances for condensation from air exfiltration, and they have the potential to result in moisture-related problems (Straube and Smegal 2009, Arena 2014, Ueno 2015). The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and reduce material brought to landfills due to failures and resulting decay. Although this document focuses on double-wall framing techniques, the majority of the information about how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture-related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super-insulated homes. The information is applicable to both new construction and gut-rehabilitation projects in Climate Zones 5 and higher.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting Cellulase Penetration Into Corn Stover Cell Walls by Immuno-Electron Microscopy

In general, pretreatments are designed to enhance the accessibility of cellulose to enzymes, allowing for more efficient conversion. In this study, we have detected the penetration of major cellulases present in a commercial enzyme preparation (Spezyme CP) into corn stem cell walls following mild-, moderate- and high-severity dilute sulfuric acid pretreatments. The Trichoderma reesei enzymes, Cel7A (CBH I) and Cel7B (EG I), as well as the cell wall matrix components xylan and lignin were visualized within digested corn stover cell walls by immuno transmission electron microscopy (TEM) using enzyme- and polymer-specific antibodies. Low severity dilute-acid pretreatment (20 min at 100 C) enabled <1% of the thickness of secondary cell walls to be penetrated by enzyme, moderate severity pretreatment at (20 min at 120 C) allowed the enzymes to penetrate {approx}20% of the cell wall, and the high severity (20 min pretreatment at 150 C) allowed 100% penetration of even the thickest cell walls. These data allow direct visualization of the dramatic effect dilute-acid pretreatment has on altering the condensed ultrastructure of biomass cell walls. Loosening of plant cell wall structure due to pretreatment and the subsequently improved access by cellulases has been hypothesized by the biomass conversion community for over two decades, and for the first time, this study provides direct visual evidence to verify this hypothesis. Further, the high-resolution enzyme penetration studies presented here provide insight into the mechanisms of cell wall deconstruction by cellulolytic enzymes.

AGRICULTURAL WASTES↗

Theory and Practice in Measuring In-Vitro Extensibility of Growing Plant Cell Walls

This chapter summarizes four extensometer techniques for measuring cell wall extensibility in vitro and discusses how the results of these methods relate to the concept and ideal measurement of cell wall extensibility in the context of plant cell growth. These in-vitro techniques are particularly useful for studies of the molecular basis of cell wall extension. Measurements of breaking strength, elastic compliance and plastic compliance may be informative about changes in cell wall structure, whereas measurements of wall stress relaxation and creep are sensitive to both changes in wall structure and wall-loosening processes, such as those mediated by expansins and some lytic enzymes. As a result, a combination of methods is needed to obtain a broader view of cell wall behavior and properties connected with the concept of cell wall extensibility.

36 MATERIALS SCIENCE↗

Burst pressure models and validations for thick-walled pipelines containing corrosion defects

Corrosion is one major threat to pipeline integrity. Over the past decades, many corrosion models have been developed for determining the remaining strength of corroded pipelines, including ASME B31.G, Modified B31.G, LPC, PCORRC and their modified models. All these corrosion models are applicable only to large diameter, thin-walled pipelines with a diameter to wall thickness ratio D/t ≥ 20. In practice, many pipelines have a small diameter and thick wall with a D/t ratio < 20, and thus an adequate corrosion model is needed for assessing remaining strength for corroded thick-walled pipelines. This paper briefly reviews the theoretical burst pressure models for defect-free thin and thick-walled pipelines and four representative corrosion assessment models for thin-walled corroded pipelines. On this basis, two modified corrosion models are proposed to thick-walled pipelines in terms of the average shear stress yield theory. To verify the proposed corrosion models, comprehensive validations are performed. Numerical validations include the elastic-plastic finite element analysis to determine burst pressure for pipelines without and with corrosion defects and the model evaluation using a large dataset of available FEA results of burst pressure for machined defects. Experimental validations include a set of burst pressure tests for defect-free thick-walled pipes with different thicknesses and the model evaluation using one large burst dataset for machined defects with flat bottoms and another large dataset for real corrosion defects with curved river bottom profiles. Both numerical and experimental validations show that the proposed corrosion models can more accurately predict the remaining strength for corroded thin and thick-walled pipelines.

Pipeline↗

Structure and growth of plant cell walls

Plant cells build nanofibrillar walls that are central to plant growth, morphogenesis and mechanics. Starting from simple sugars, three groups of polysaccharides, namely, cellulose, hemicelluloses and pectins, with very different physical properties are assembled by the cell to make a strong yet extensible wall. Here, this Review describes the physics of wall growth and its regulation by cellular processes such as cellulose production by cellulose synthase, modulation of wall pH by plasma membrane H + -ATPase, wall loosening by expansin and signalling by plant hormones such as auxin and brassinosteroid. In addition, this Review discusses the nuanced roles, properties and interactions of cellulose, matrix polysaccharides and cell wall proteins and describes how wall stress and wall loosening cooperatively result in cell wall growth.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of a Conducting Wall on Z-Pinch Stability

Here, the stabilizing effect of a conducting wall on Z-pinch stability has been investigated through a systematic experimental and numerical study. Numerical simulations of a Z-pinch with a cylindrical conducting wall are compared with a case that modeled perforations in the conducting wall. The conducting wall also acts as the return current path for these investigations. Plasma conditions with various pinch sizes were studied numerically to better understand the effect of wall stabilization in Z-pinches. A study using the ZaP Flow Z-Pinch was performed by inserting a 0.35-m perforated section of electrode that has eight longitudinal slots cut from the outer electrode, reducing the conducting wall material by ≈70% .This modification prevents currents from flowing freely along the azimuthal distance of the outer electrode required to stabilize the m = 1, 2, 3 modes, which are experimentally monitored. Operating with identical experimental parameters with and without the perforated electrode was assumed to produce similar equilibrium and flow shear conditions in the pinch. Comparing the stability characteristics isolated the potential effects of the conducting wall. Magnetic data, interferometry, and optical images indicate that the conducting wall does not have a discernible effect on stability in the ZaP experiment. This result agrees with simulations with similar ratios of conducting wall radius to pinch radius.

42 ENGINEERING↗