Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waste Packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. Erratum

Please insert erratum page in report PNNL-14805. This erratum serves to correct the K g (Glass apparent equilibrium constant based on the SiO 2 (aq) activity) values affected by a calculation error for glasses LAWA44, LAWB45 and LAWC22. The error was first identified by Papathanassiu et al. (2011). The K g values were corrected by Freedman et al. (2015) by multiplying the erroneous K g values by approx. 3.4. As indicated in Freedman et al. (2015), this 3.4 factor originates from the erroneous use of the molecular weight of H 4 SiO 4 (96.114 g·mol –1 ) instead of the molecular weight for Si (28.086 g·mol –1 ).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experience by BAM in the Transport Package Safety Assessment of German Waste Containers - 18469

Transport and storage containers for low and mid-level radioactive waste are getting more and more of relevance due to the nuclear phase out decision in 2011. For higher activities Type B(U) approved waste containers will be needed for the shut down and dismantling phases of NPPs. It is expected that large quantities are required in the near future. German waste containers are generally approved for transport and interim storage and are also intended for the final disposal in the Konrad repository. BAM is involved in the authority licensing of transport package designs in Germany. In this context, BAM is responsible for the assessment of safe containment, mechanical, thermal and quality management issues. BAM also operates test facilities and performs drop as well as thermal tests during package licensing procedures. This paper summarizes our experience in the transport package design assessment of Type B(U) waste containers. A general overview of the approval process, the requirements and approaches BAM applies are described. Some examples are used to illustrate different aspects and technical issues we are addressing during the package assessment. In the first part of the paper the specific design aspects of German waste containers are described. Here, a general overview is given e.g. about closure systems, impact limiter designs, and the handling concepts. Furthermore, the wide range of radioactive content and their physical behavior including the impact on the packages assessment are described. The second part is focused on questions about the licensing and assessment process of German waste containers from the BAM authority point of view. The general approaches for the strategy of demonstration are outlined on the basis of the test conditions according to IAEA Regulations SSR-6. Furthermore, particular issues of the mechanical and thermal assessment with respect to the specific test conditions are discussed. For accident conditions of transport, aspects to be mentioned are e.g. the assessment of the lid bolts, the axial gap applied between content and lid, and the thermal behavior of the wood filled impact limiter after the fire test. However, issues of the assessment for routine and normal conditions of transport are addressed in this paper, too. The intention of this paper is introduce recent approval procedure experience in Germany, describing technical evaluation issues and so reduce rounds of questions during applications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stockham Waste Management Contract SOW

Sandia National Laboratories, New Mexico (SNL/NM) is a multi-program Research and Development Facility, owned by the Department of Energy (DOE) and operated by Sandia Corporation, a Lockheed Martin Company (LMC). Sandia waste management operations include radioactive and mixed waste and hazardous waste (including classified and explosive). Waste management activities include managing and characterizing the waste, completing waste disposal requests, and providing guidance on sorting, packaging, & storing wastes, preparing all necessary disposal request documents, and/or recycling, maintaining accurate records, help the line organizations in assuring the compliance of all waste management activities, and preparing compliance-related documentation. Additional contaminants may include polychlorinated biphenyls (PCBs), asbestos, and beryllium. Some radioactive and hazardous waste may also be managed as classified waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation of Spent Nuclear Fuel loading into a Final Waste Repository

Previous work towards studying repository loading have used: - spent nuclear fuel (SNF) with an average burnup composition; - a lumped capacitance thermal model for calculating temperature in a Cyclus repository model. The goal of this work is to improve on the repository models and use U.S. historical SNF inventory data in simulations to more accurately study the loading of a waste repository. These goals will be achieved by: - using UNF-ST-and-DARDS Unified Database (UDB) that has historic assembly-specific data (e.g, isotopic composition, heat) in Cyclus simulations; - implementing a more accurate thermal model within a Cyclus repository model. Objectives: - Create a Cyclus spent fuel conditioning model that packages spent fuel bundles into packages which have user-defined properties. - Create a Cyclus medium-fidelity repository model that gives accurate time and spatial dependent temperature values and loads the repository based on a user-selected loading strategy. Cyclus is an agent-based extensible framework for modeling flow of material through user-defined nuclear fuel cycles. In Cyclus, each facility in the fuel cycle is modeled individually and the facilities interact with one another as independent agents. The spent fuel conditioning model accepts spent fuel bundles and puts them into a cylindrical waste package. In the spent fuel conditioning model, the user can define variables: For each layer, radius, thermal conductivity, thermal diffusivity; For each package, Number of spent fuel bundles, Radius and height. The waste repository model accepts waste packages and emplaces them into available positions within the waste repository based on a thermal criteria. The thermal criteria is a temperature limit at the interface between the waste package surface and the host geology, that is set based on the repository's host geology. In the waste repository model, the user can define the variables: Capacity, Distance between waste packages, Distance between drifts, Repository host geology, Loading Strategy. After the addition of new waste packages at each time step, the waste repository model recalculates the temperature at each location in the repository. If the addition of this new package causes its temperature to exceed the thermal limit, it will be placed back into the buffer. A thermal model that relies on a transient 'outside' model and quasi-steady-state 'inside' model is used to accurately determine the temperature in the repository. The 'outside' model assumes a homogenous medium with the Engineered Barrier System (EBS) replaced by the geologic medium. Temperature solutions for the central waste package, adjacent point and line sources are superimposed to calculate the temperature at specific points in the repository. The central drift consists of one finite line source which represents the central waste package. The central drift also consists of point sources that represent neighboring waste packages in the central drift. The neighboring drifts are represented by infinite line sources. The 'inside' model is considered to be at a quasi-steady-state condition because EBS has a relatively low thermal mass compared to the infinite geologic medium. The steady state calculation is performed at each time step with the heat source and interface temperature as boundary conditions. Future Work: Run Cyclus simulations with U.S. historical SNF inventory data, the spent fuel conditioning and repository models to study how waste package acceptance strategies impact repository loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deep Borehole Field Test Specifications

This report documents conceptual design development for the Deep Borehole Field Test (DBFT), mainly the test packages (not containing waste) and the system for demonstrating emplacement and retrieval of those packages in the Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system for specific waste forms. This document therefore describes a current reference DBD concept, and analyzes key design options for disposal, to guide selection of options for the DBFT. The most important of these options is the emplacement mode, i.e. whether packages are emplaced using a wireline or a string of drill pipe (with a drill rig). This choice is analyzed using cost and risk models, in Sections 5 and 6. Other emplacement mode options are also identified and discussed. The reference DBD concept and the analysis of waste packaging and emplacement options, are used to develop requirements and assumptions for the DBFT and to recommend DBFT specifications. Design issues are identified, and priorities are developed for further conceptual design development and additional engineering analysis, anticipating future design activities. Conceptual design development is part of a process that proceeds in three stages: 1) conceptual design including feasibility studies; 2) preliminary design that includes technical and cost information necessary for final design; and 3) final design sufficient for fabrication or construction. The DBFT engineering demonstration will follow such an evolution. Whereas design evolution typically begins with bench-scale and pilot-scale investigations proceeding to conceptual, preliminary, and final designs, the DBFT can proceed directly to design because of extensive previous work and published literature on scientific drilling, characterization methods, waste packaging and handling, industrial deep-hole drilling and construction, and downhole operations. Hence it is anticipated that this report will lead to completion of conceptual design, then preliminary and final design, fabrication and testing, and demonstration of waste emplacement in a deep borehole.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EPRI Research Results: The EPRI Implementation Guide for the NRC BTP on Concentration Averaging and Encapsulation - 17488

The Nuclear Regulatory Commission published Revision 1 of the Branch Technical Position (BTP) on 'Concentration Averaging and Encapsulation' (BTP 2015.) PRI developed an Implementation Guide for applying BTP 2015 to nuclear power plant specific waste streams. This Implementation Guide has been vetted and supported by an EPRI organized working group consisting of industry participants (including utilities subject matter experts, disposal sites, NRC and Agreement State representatives and industry experts) will ensure compliant and consistent application during waste generation, packaging, processing and disposal activities. The Implementation Guide provides for a comparison to previous BTP guidance and provides clarification and common understanding of the key concepts contained within the revised BTP. These include averaging constraints, hot spots, waste streams, waste types, discrete items, blending, solidification, encapsulation and alternative approaches. EPRI published the Implementation Guidance for the Nuclear Regulatory Commission Branch Technical Position on 'Concentration Averaging and Encapsulation, Revision 1' (EPRI Report 3002008189) in the September 2016 and it was made available to the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Packaging, Transportation and Recycling of NPP Condenser Modules - 12262

Perma-Fix was awarded contract from Energy Northwest for the packaging, transportation and disposition of the condenser modules, water boxes and miscellaneous metal, combustibles and water generated during the 2011 condenser replacement outage at the Columbia Generating Station. The work scope was to package the water boxes and condenser modules as they were removed from the facility and transfer them to the Perma-Fix Northwest facility for processing, recycle of metals and disposition. The condenser components were oversized and overweight (the condenser modules weighed ∼102,058 kg [225,000 lb]) which required special equipment for loading and transport. Additional debris waste was packaged in inter-modals and IP-1 boxes for transport. A waste management plan was developed to minimize the generation of virtually any waste requiring landfill disposal. The Perma-Fix Northwest facility was modified to accommodate the ∼15 m [50-ft] long condenser modules and equipment was designed and manufactured to complete the disassembly, decontamination and release survey. The condenser modules are currently undergoing processing for free release to a local metal recycler. Over three millions pounds of metal will be recycled and over 95% of the waste generated during this outage will not require land disposal. There were several elements of this project that needed to be addressed during the preparation for this outage and the subsequent packaging, transportation and processing. - Staffing the project to support 24/7 generation of large components and other wastes. - The design and manufacture of the soft-sided shipping containers for the condenser modules that measured ∼15 m X 4 m X 3 m [50 ft X 13 ft X 10 ft] and weighed ∼102,058 kg [225,000 lbs] - Developing a methodology for loading the modules into the shipping containers. - Obtaining a transport vehicle for the modules. - Designing and modifying the processing facility. - Movement of the modules at the processing facility. If any of these issues were not adequately resolved prior to the start of the outage, costly delays would result and the re-start of the power plant could be impacted. The main focus of this project was to find successful methods for keeping this material out of the landfills and preserving the natural resources. In addition, this operation provided a significant cost savings to the public utility by minimizing landfill disposal. The onsite portion of the project has been completed without impact to the overall outage schedule. By the date of presentation, the majority of the waste from the condenser replacement project will have been processed and recycled. The goals for this project included helping Energy Northwest maintain the outage schedule, package and characterize waste compliantly, perform transportation activities in compliance with 49CFR (Ref-1), and minimize the waste disposal volume. During this condenser replacement project, over three millions pounds of waste was generated, packaged, characterized and transported without injury or incident. It is anticipated that 95% of the waste generated during this project will not require landfill disposal. All of the waste is scheduled to be processed, decontaminated and recycled by June of 2012. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation Guide for the Revised Branch Technical Position on Concentration Averaging and Encapsulation - 16021

As a result of the research begun in 2007 to better understand the bases of the Branch Technical Position (BTP) on 'Concentration Averaging and Encapsulation' and 10 CFR 61 'Licensing Requirements for Land Disposal of Radioactive Waste', EPRI identified three regulatory initiatives that could be pursued to enhance disposal options for the industry. These initiatives directly follow the NRC strategic assessment. The first was to revise the BTP to allow broader blending of compatible waste types. The second was to examine how 10 CFR 61.58 'Alternative requirements for waste classification and characteristics' could be used to allow for an alternative disposal criterion based on site-specific hydro-geological characteristics and end land use scenarios. And, the third is to develop a technical basis for risk informed disposal regulations in anticipation of a 10CFR 61 rulemaking. By the summer of 2015 these initiatives had been broadly addressed and resulted in the NRC issuing Revision 1 to the BTP in February of 2015. Revision 1 of the BTP (BTP 2015) is a significant re-write of the draft issued in May 2012 and a significant improvement over the 1995 BTP (BTP 1995). The NRC has altered many of the positions in the interest of clarification. The development of an Implementation Guide for applying BTP 2015 to industry-specific waste streams that is vetted and supported by a EPRI sponsored working group consisting of industry participants (including utilities, disposal sites, NRC and Agreement State representatives and industry experts) will ensure compliant and consistent application during waste generation, packaging, processing and disposal activities. The Implementation Guide will provide for a comparison to previous BTP guidance and provide clarification and common understanding of the key concepts contained within the revised BTP. These include averaging constraints, hot spots, waste streams, waste types, discrete items, blending, solidification, encapsulation and alternative approaches. EPRI plans to publish the BTP Implementation Guide in the second quarter of 2016 and it will be available to the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive Waste Management in a Treatability and Optimisation Perspective - 17527

In order to meet recycling criteria or to fulfil Waste Acceptance Criteria (WAC) for disposal there are many different management concepts for radioactive waste that can be applied. Which concept or set of concepts to use to optimize waste management depends on several factors, among them, the regulatory framework for recycling, the availability of a disposal facility and the acceptance criteria for disposal. The required pre-treatment and other pre-disposal activities should be carefully analyzed for each of the disposal options, as they are significant contributors to the total cost for managing the waste. Waste Acceptance Criteria are living documents that should be updated when regulatory framework changes as well as when new treatment methods and new packaging and barrier systems develop. Each waste treatment facility, has its own specific limitations and therefore its own WAC/CFA (conditions for acceptance), which depends both on the plant design and national legislation. Many waste owners, countries or licensees, have their preferred, and in some cases well established, waste routes for certain waste streams. In some countries, the full chain from waste treatment through to disposal of radioactive waste is in place, whilst other countries still are in the process of establishing their repository program. The worst case scenario for any licensee or waste owner is waste which is not possible to qualify for disposal. This can be due to poor or degraded waste containers, unspecified content in waste packages, or wastes that are not suitable for disposal in their current form. Such deficiencies result in expensive actions related to waste retrieval, new characterisation and/or costly investigations. The EDF Group has a fleet of waste treatment facilities and has, for decades, provided waste treatment services to domestic and international customers. This paper will discuss important waste owner considerations and EDF experiences related to the optimization of the waste management process. This will be from both a treatment and an end-state perspective. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EDF industrial strategy for the management of radioactive waste - 15204

In France, EDF is in charge of electronuclear power operation since the sixties and consequently has to manage radioactive waste. Radioactive waste management is based on the control of each industrial step, taking into account the classification by activity level and radioactive half life. The main steps are to limit waste quantities at the generation stage, sort out non-rad and recoverable items from the waste, recycle, treat and package the radioactive waste as soon as it is generated, limit the use of interim storage, prepare and achieve as soon as reasonably practicable conditioning and disposal. EDF aims to empower operators in charge of NPP operating and of decommissioning and to centralize interfaces with the stakeholders in order to pool management routes and to guarantee the consistency of our industrial policy. The French regulatory framework for the management of radioactive waste and material is set by the French 2006 planning Act, in line with the European Directive. The legal framework structures interactions between EDF and the regulatory bodies (Nuclear Safety Authority, General Directorate for Energy and Climate), the French National Radioactive Waste Management Agency (ANDRA) and other waste producer (mainly AREVA Company and CEA). Regarding short lived waste, management routes are in current operation for the large majority of this waste generated both by power plants in service and during decommissioning. EDF is working on new management route for metallic materials knowing the future evolution of deposits is the field of large refit and decommissioning activities. Regarding long lived waste, disposal development represents a major stake for EDF. EDF contributes to design studies of the geological disposal center and collaborates with ANDRA for the acceptance of future national waste disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Operations Manual (Rev. 4)

This procedure provides operating instructions for the remote-handled transuranic (RH-TRU) 72-B Waste Shipping Package (hereinafter referred to as "RH-TRU 72-B"). In this document, "Packaging" refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). "Package" refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Before RH-TRU 72-B loading operations begin, loading procedures and revisions must be sent to the DOE Carlsbad Field Office (CBFO) at site.documents@wipp.ws for approval. Loading of the RH-TRU 72-B can be done one of two ways: on the cask trailer in the vertical position or by removing the cask from the trailer and loading it in an area designated for remote-handling. Two types of trailers were specially designed to transport the RH-TRU 72-B: a spread-axle trailer requiring a crane to rotate the cask and a cask uprighting trailer designed with built-in hydraulics to rotate the RH-TRU 72-B into the vertical position while on the trailer. The hydraulic power unit is a separate piece of equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Operations Manual (Rev. 5)

This procedure provides operating instructions for the remote-handled transuranic (RH-TRU) 72-B Waste Shipping Package (hereinafter referred to as "RH-TRU 72-B"). In this document, "Packaging" refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). "Package" refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Before RH-TRU 72-B loading operations begin, loading procedures and revisions must be sent to the DOE Carlsbad Field Office (CBFO) at site.documents@wipp.ws for approval. Loading of the RH-TRU 72-B can be done one of two ways: on the cask trailer in the vertical position or by removing the cask from the trailer and loading it in an area designated for remote-handling. Two types of trailers were specially designed to transport the RH-TRU 72-B: a spread-axle trailer requiring a crane to rotate the cask and a cask uprighting trailer designed with built-in hydraulics to rotate the RH-TRU 72-B into the vertical position while on the trailer. The hydraulic power unit is a separate piece of equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Operations Manual (Rev. 6)

This procedure provides operating instructions for the remote-handled transuranic (RH-TRU) 72-B Waste Shipping Package (hereinafter referred to as "RH-TRU 72-B"). In this document, "Packaging" refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). "Package" refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Before RH-TRU 72-B loading operations begin, loading procedures and revisions must be sent to the DOE Carlsbad Field Office (CBFO) at site.documents@wipp.ws for approval. Loading of the RH-TRU 72-B can be done one of two ways: on the cask trailer in the vertical position or by removing the cask from the trailer and loading it in an area designated for remote-handling. Two types of trailers were specially designed to transport the RH-TRU 72-B: a spread-axle trailer requiring a crane to rotate the cask and a cask uprighting trailer designed with built-in hydraulics to rotate the RH-TRU 72-B into the vertical position while on the trailer. The hydraulic power unit is a separate piece of equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Operations Manual (Rev. 7)

This manual provides basic operating instructions for the remote-handled transuranic (RH-TRU) 72-B Cask Waste Shipping Package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Operations Manual (Rev. 3)

This procedure provides operating instructions for the remote-handled transuranic (RH-TRU) 72-B Cask Waste Shipping Package (hereinafter referred to as "72-B cask"). In this document, "Packaging" refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). "Package" refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Before 72-B cask loading operations begin, loading procedures and revisions must be sent to the DOE Carlsbad Field Office (CBFO) at site.documents@wipp.ws for approval. Loading of the 72-B cask can be done one of two ways: on the cask trailer in the vertical position or by removing the cask from the trailer and loading it in an area designated for remote-handling. Two types of trailers were specially designed to transport the 72-B cask: a spread axle trailer requiring a crane to rotate the cask and a cask uprighting trailer designed with built-in hydraulics to rotate the 72-B cask into the vertical position while on the trailer. The hydraulic power unit is a separate piece of equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Program Guidance (Rev. 3)

The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the Remote Handled-Transuranic (RH-TRU) 72-B Waste Shipping Package (also known as the "RH-TRU 72-B") and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions or equivalent approved instructions. Following these instructions assures that operations meet the requirements of the SARP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Program Guidance (Rev. 3.1)

The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the Remote-Handled Transuranic (RH-TRU) 72-B Waste Shipping Package (also known as the "RH-TRU 72-B") and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states, "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "…each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Department of Energy Carlsbad Field Office or the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliances," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions or equivalent approved instructions. Following these instructions assures that operations meet the requirements of the SARP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗